MAURY USCG vessel records Sign in
← All vessels

TG PROVIDER

TG PROVIDER is a 1989 offshore supply vessel. The Coast Guard has recorded 36 inspections since 1989, most recently in May 2022, along with 26 deficiencies.

Records from 1989 to 2022. Most recent: inspection, 18 May 2022.

Built
1989
Last inspected
18 May 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8977182 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF6486
332268
Flag
BAHAMAS, THE
338025000, 367474760 (licence lapsed)
Maury page id
psix-332268

Inspections, by type

…with no type recorded3
Years with a record 25 calendar years (1989–2022)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
390 - Convention (Subpart B), Gross Ton
287 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF6486MMSI 367474760 · expired · compulsorily equipped · granted 23 December 2010, cancelled 27 February 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDB7806MMSI 338025000 · cancelled · compulsorily equipped · granted 15 May 2004, cancelled 4 March 2010 · licensed under a name not among this hull’s recorded names (not shown)
WAF3933MMSI 338025000 · cancelled · compulsorily equipped · granted 29 April 1998, cancelled 25 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

INT'L DEFENDER Offshore Supply Vessel · MISLE 52967 · 19 June 2002 · activity 1633987GLOBAL LIFT 2 Offshore Supply Vessel · MISLE 168507 · 19 June 2002 · activity 1633987CECELIA Passenger (Inspected) · MISLE 263213 · 19 June 2002 · activity 1633987

Inspection history · 36

18 May 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7453591
28 February 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4252772
6 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202717
24 February 2011 DAPI Audit
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3953989
21 December 2010 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914976
7 December 2010 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3906648
19 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3421099
13 February 2008 Hull Examination · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3146878
16 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2932088
1 May 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2920039
23 October 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806447
23 October 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806456
14 March 2006 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2602424
24 February 2005 COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2298397
20 February 2004 Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2009789
22 January 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1733606
19 June 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1633987
19 June 2002 Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1634393
14 February 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1486409
22 May 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426613
25 February 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369531
28 January 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390926
28 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411650
4 March 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1409673
8 March 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387940
24 October 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 52863
15 May 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472213
3 May 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450844
24 May 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 28841
22 April 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 835703
24 April 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457047
20 June 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207091
3 May 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226953
8 January 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912194
28 June 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920754
29 July 1989 Hull Examination · Plan Review "T" Boat · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205595

Deficiency record · 26

Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 February 2011 Resolved
Vessel owner/operator failed to submit MIS report for 2009 by the required deadline of 15MAR10. The MIS report was not submitted until 21DEC10.
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Submitted MIS report.
Fire Fighting › Means of Escape › Doorways
Issued 1 May 2007 Resolved
The forward emergency exit was properly marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 May 2007 Resolved
The EPIRB lanyard was tied off to the housing assembly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2007
Fire Fighting › Means of Escape › Doorways
Issued 1 May 2007 Resolved
The engine room door handle was reversed and did not open in the correct position.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 February 2005 Resolved
Renew distribution panel covers on the two panels located next to the hatch in the aft E/R bulkhead. If covers cannot be renewed, renew entire boxes.
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: New panels installed.
Deck/Cargo › Vapor Control Systems
Issued 26 February 2004 Resolved
Provide proper flame screen on sewage vent. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2004
Resolution: Installed proper flame screen.
Fire Fighting › Means of Escape
Issued 26 February 2004 Resolved
Properly label emergency escape from the engine room. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2004
Resolution: Properly labelled E/R emergency escape.
Operations/Management › Drills/Instruction
Issued 26 February 2004 Resolved
Provide emergency broadcast placard in pilot house. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2004
Resolution: Emergency broadcast placard provided.
Fire Fighting › Combustible Materials
Issued 26 February 2004 Resolved
Remove all paint from the vessel as no suitable paint locker is on board vessel. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2004
Resolution: All paint and combustible liquids were removed from the vessel.
Electrical › Electrical Distribution System (service)
Issued 21 February 2002 Resolved
REMOVE ALL PLASTIC WIRE TIES IN ENGINE ROOM AND GEN ROOM OVERHEAD, AND REPLACE WITH PROPER METALLIC TIES. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 21 February 2002
Resolved 21 February 2002
Fire Fighting › Nozzles
Issued 21 February 2002 Resolved
PRIOR TO CARRYING COMBUSTIBLE OR FLAMMABLE PRODUCTS IN MPT'S IAW COI ENDORSEMENT, SUPPLY AN APPROVED FOAM NOZZLE. LEGACY COMPONENT DESC: Type
Due 21 February 2002
Resolved 21 February 2002
Communications › Radio Communications
Issued 21 February 2002 Resolved
PRIOR TO PROCEEDING MORE THAN 100NM OFSHORE REPAIR EMERGENCY POWER SUPPLY FOR SSB RADIO. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Condition: Improper Installation
Due 21 February 2002
Resolved 21 February 2002
Construction/Loadline › Penetrations › Pipe Flange
Issued 21 February 2002 Resolved
INSTALL METALLIC VALVE ON PVS PIPE PENETRATION IN CREW VOID WATERTIGHT BULKHEAD
Condition: Improper Installation
Due 21 February 2002
Resolved 21 February 2002
Electrical › Electrical Distribution System (service)
Issued 21 February 2002 Resolved
PROVIDE AND INSTALL BATTERY BOX FOR PORT CENTER ENGINE LEGACY COMPONENT DESC: BATTERY
Due 21 February 2002
Resolved 21 February 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 February 2002 Resolved
PROVIDE AND INSTALL DISTRIBUTION PANEL DOOR LOCKING DEVICE.
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 21 February 2002
Fire Fighting › Miscellaneous Items
Issued 21 February 2002 Resolved
PROVIDE AND INSTALL INTAKE/EXHAUST LOUVER COVER RETAINING CLIP ON PORT FWD VENT. LEGACY COMPONENT DESC: INTAKE LOUVERS
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 21 February 2002
Electrical
Issued 22 May 2001 Resolved
Missing air gaps or back flow preventers to head tanks for both generators.
Condition: Unknown
Due 22 May 2001
Resolved 15 June 2001
Unknown
Issued 22 May 2001 Resolved
Loose wire under bridge console.
Condition: Unknown
Due 22 May 2001
Resolved 15 June 2001
Unknown
Issued 22 May 2001 Resolved
Missing chart for the entrance into Cameron, La.
Condition: Unknown
Due 22 May 2001
Resolved 15 June 2001
Electrical
Issued 28 January 1999 Resolved
Install machinery guard over port generator's front pully.
Condition: Unknown
Due 7 February 1999
Resolved 7 February 1999
Accommodation/Occupational Safety
Issued 28 January 1999 Resolved
Provide markings for generator room and fwd passenger's lounge emmergency exits per 46CFR 185.606.
Condition: Unknown
Due 7 February 1999
Resolved 7 February 1999
Accommodation/Occupational Safety
Issued 4 March 1997 Resolved
GOUGE AND REWELD CRACKED WELD ON RAIL, STBD SIDE AT BACK OF HOUSE. ITEM MTO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO04APR97.
Condition: Unknown
Due 6 March 1997
Resolved 1 May 1997
Electrical
Issued 4 March 1997 Resolved
REPAIR DAMAGED ELECTRICAL WIRE TO FWD MSD HOLDING TANK. ITEM TO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO 04APR97.
Condition: Unknown
Due 6 March 1997
Resolved 1 May 1997
Lifesaving
Issued 4 March 1997 Resolved
ATTACH EACH LIFEFLOAT TO THE PAINTER AT SUFFICIENT INTERVALS AS TO NOT IMPEDE DEPLOYMENT. ITEM TO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO 04APR97.
Condition: Unknown
Due 6 March 1997
Resolved 1 May 1997
Fire Fighting
Issued 4 March 1997 Resolved
CROP AND RENEW HOLED ELBOW ON SUCTION SIDE OF MAIN FIRE PUMP. ITEM TO BE COMPLETED PRIOR TO DEPARTURE._x001C_
Condition: Unknown
Due 6 March 1997
Resolved 1 May 1997
Fire Fighting
Issued 4 March 1997 Resolved
RENEW BROKEN BRACKET SUPPORTING FIRE MONITOR. ITEM TO BE COMPLETED PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 March 1997
Resolved 1 May 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.