MAURY USCG vessel records Sign in
← All vessels

SUFFOLK

SUFFOLK is a 1989 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1989, most recently in October 2022, along with 35 deficiencies.

Records from 1989 to 2022. Most recent: inspection, 17 October 2022.

Built
1989
Last inspected
17 October 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9668
335712
Flag
UNITED STATES
—
Maury page id
psix-335712

Inspections, by type

…with no type recorded4
Years with a record 33 calendar years (1989–2022)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NORFOLK Passenger (Inspected) · MISLE 362072 · 2 December 2016 · activity 6060395SEAPEAK CATALUNYA Tank Ship · MISLE 651580 · 2 November 2005 · activity 2526870

Inspection history · 54

17 October 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7578677
22 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7482644
13 December 2021 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7366885
29 March 2021 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7163236
19 June 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6980818
22 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6839529
6 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6703612
14 June 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6444313
8 November 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6303410
22 March 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6109382
2 December 2016 Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6051446
2 December 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6060395
25 March 2016 COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5840615
23 December 2015 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5786380
19 June 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4893244
21 May 2014 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4864187
21 March 2014 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4820304
19 June 2012 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4348917
6 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4202871
23 September 2011 Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4152687
26 March 2010 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3703184
6 April 2009 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3447308
19 May 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3211049
11 March 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3162012
29 June 2007 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2977392
11 April 2006 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2621909
2 November 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2526870
8 June 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2383456
29 March 2004 Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2034900
17 March 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1869078
29 May 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1622548
15 March 2002 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1494022
20 March 2001 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1426551
24 April 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1415348
27 March 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1389036
29 March 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1115707
26 March 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123139
19 March 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1111370
27 March 1997 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099273
19 March 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1104686
18 March 1996 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886310
4 March 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 884500
20 March 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1179477
4 October 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 869714
16 March 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1165064
15 March 1994 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 854273
27 July 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 656126
4 May 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1134655
2 December 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 962826
1 May 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1256696
10 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1263301
24 April 1991 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1246195
8 May 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 917170
10 July 1989 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 898075

Deficiency record · 35

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 June 2022 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. No visual alarm was shown when bilge pump was used in auto/manual.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 30 June 2022
Resolution: Witnessed operational test of bilge pump alarm.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 June 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have an audible alarm that sounds upon discharge. Alarm did not sound when testing pre-engineered fixed gas fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 30 June 2022
Resolution: Witnessed operational test of fireboy system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019 Resolved
A submersible electric bilge pump may be used provided that the pump is permanently mounted. Pump is not permanently mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 17 June 2019
Resolution: Pump is permanently mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019 Resolved
A submersible electric bilge pump may be used provided a a positive shutoff valve is installed at the hull penetration. No valve is installed at the hull penetration.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 17 June 2019
Resolution: valve is installed at the hull penetration
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 December 2016 Resolved
Prove proper operation of vessel to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2016
Resolution: Completed underway checks. All sat.
Stability › Watertight Integrity › General
Issued 25 March 2016 Resolved
Recoat exposed fiberglass on stem and starboard quarter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 23 May 2016
Resolution: Exposed fiberglass on the stem and starboard quarter was recoated.
Stability › Watertight Integrity › General
Issued 25 March 2016 Resolved
Repair fiberglass damage on port quarter.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 23 May 2016
Electrical › Electric Supply System (service) › Transformer
Issued 23 March 2006 Resolved
Mount electrical inverter properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Engineering › Fuel Oil Service System › Vent Pipe
Issued 23 March 2006 Resolved
Install flame screen.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 11 April 2006
Stability › Weathertight Integrity
Issued 9 April 2004 Resolved
Remove or replace glass on windshields with safety glass.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 16 April 2004
Lifesaving › Lifebuoys
Issued 9 April 2004 Resolved
Install retro tape on ringbuoy.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 16 April 2004
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 9 April 2004 Resolved
Tighten Shaft Packing.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 16 April 2004
Documentation
Issued 19 March 1997 Resolved
ISSUED REQUIREMENT TO PROVE COMPLIANCE WITH DRUG TESTING REGULATIONS AS OUTLINED IN 46 CFR PART 16.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Engineering
Issued 19 March 1997 Resolved
ISSUED REQUIREMENT TO INSTALL SECOND CLAMP AROUND CONNECTION OF MAIN ENGINEEXHAUST LINE WITH MAIN ENGINE.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Lifesaving
Issued 19 March 1997 Resolved
VESSEL'S LIFE RING PRESENTLY SERVICEABLE BUT BADLY WORN IN TWO LOCATIONS. ISSUED REQUIREMENT TO REPLACE WITH NEW RING MEETING REQUIREMENTS OF 46 CFR 180.70.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Fire Fighting
Issued 18 March 1996 Resolved
BRING THE FIXED FIRE EXTINGUISHING SYSTEM IN COMPLIANCE WITH 46 CFR PART 181 SUBPART D (ENGINE COMPARTMENT). UNTIL ITEM CORRECTED VESSEL IS REQUIRED TO CARRY 2 BII PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 March 1996
Resolved 1 April 1996
Lifesaving
Issued 18 March 1996 Resolved
REPAIR OR REPLACE TWO LIFE PRESERVERS (CHILD - MISSING REFLECTIVE, ADULT - SMALL TEAR).
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Navigation
Issued 18 March 1996 Resolved
UPDATE NAVIGATION RULES TO REFLECT CHANGES.
Condition: Unknown
Due 29 March 1996
Resolved 1 April 1996
Documentation
Issued 18 March 1996 Resolved
POST STABILITY LETTER AS REQUIRED BY 46 SUBCHAPTER "T".
Condition: Unknown
Due 29 March 1996
Resolved 1 April 1996
Engineering
Issued 4 March 1996 Resolved
RENEW THE MDE COOLING WATER SUCTION LINE.
Condition: Unknown
Due 5 March 1996
Resolved 4 March 1996
Unknown
Issued 20 March 1995 Resolved
NO LATER THAN 20 APRIL 1995 IF OPERATING IN OTHER THAN TENDER SERVICE, PROVIDE ONE DECK HAND IN ADDITION TO MASTER.
Condition: Unknown
Due 20 April 1995
Resolved 4 April 1995
Fire Fighting
Issued 20 March 1995 Resolved
PROVIDE SERVICING REPORT FOR ENGINE COMPARTMENT HALON EXTINGUISHER.
Condition: Unknown
Due 27 March 1995
Resolved 21 March 1995
Documentation
Issued 15 March 1994 Resolved
PRIOR TO OPERATION AND NO LATER THAN 15 APRIL 94 POST OIL POLLUTION PLACARDAND PROHIBITED DISCHARGE PLACARD.
Condition: Unknown
Due 15 April 1994
Resolved 16 March 1994
Documentation
Issued 15 March 1994 Resolved
NOTIFY COAST GUARD MSO BOSTON UPON RECEIPT OF VALID FCC STATION LICENSE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Lifesaving
Issued 15 March 1994 Resolved
REMOVE OUTDATED DISTRESS FLARES FROM VESSEL PRIOR TO OPERATION.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Documentation
Issued 15 March 1994 Resolved
PROVIDE VALID FCC STATION LICENSE OR PROOF OF APPLICATION NO LATER THAN 22 MARCH 94.
Condition: Unknown
Due 22 March 1994
Resolved 16 March 1994
Engineering
Issued 4 May 1993 Resolved
PROVIDE PROPER BONDING CABLE FOR FUEL TANK PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Unknown
Issued 4 May 1993 Resolved
PRIVIDE SATISFACTORY EVIDENCE THAT CHEMICAL TESTING REQUIRED BY 46 CFR PART16 IS BEING CONDUCTED OF VESSEL'S CREW NO LATER THAN 10 MAY 1993.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 4 May 1993 Resolved
PROPERLY SECURE ELECTRICAL WIRING TO STERN LIGHT PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Unknown
Issued 4 May 1993 Resolved
PROVIDE VALID FCC STATION LICENSE PRIOR TO OPERATING MORE THAN 1000 FEET FROM LAND WITH PASSENGERS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Engineering
Issued 4 May 1993 Resolved
PROVE PROPER OPERATION OF EMERGENCY FUEL SHUT-OFF PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Unknown
Issued 4 May 1993 Resolved
PROVIDE CURRENT VESSEL REGISTRATION PRIOR TO OPERATING.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Navigation
Issued 4 May 1993 Resolved
PROVE PROPER OPERATION OF VESSEL'S NAVIGATION LIGHTS PRIOR TO OPERATING.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Unknown
Issued 4 May 1993 Resolved
PROVIDE SATISFACTORY RING BUOY PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Fire Fighting
Issued 4 May 1993 Resolved
REMOVE INOPERABLE PULL-HANDLE FOR MANUAL HALON SYSTEN DUE TO INSTALLATION OF HEAT ACTIVATED TYPE, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993