Records from 1989 to 2026. Most recent: inspection, 19 February 2026.
Inspection history · 107
19 February 2026
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8312362
8 January 2026
Vessel Attendance · Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8285691
14 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8210309
14 August 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8212476
20 November 2024
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8037684
8 January 2024
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7828273
12 December 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7827989
14 November 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807599
6 October 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7804528
11 August 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7766106
21 November 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7597643
1 November 2022
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7546990
30 October 2022
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7586433
15 September 2022
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7504439
10 May 2022
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7446844
25 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7363810
4 February 2021
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7135912
4 February 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7136343
14 December 2020
Examination of Repairs · DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7111305
30 September 2020
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7041682
7 January 2020
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6866139
22 September 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6835668
20 September 2019
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6816741
20 September 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6835444
8 January 2019
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6592796
10 December 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6595307
8 December 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6597672
7 September 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6534327
13 August 2018
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6512124
9 January 2018
Excursion Permit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6334902
10 October 2017
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6286462
24 January 2017
Excursion Permit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076863
10 January 2017
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6062673
15 September 2016
Examination of Repairs · Welding Related Inspections Qualification Testing · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6001251
2 July 2016
Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 5928001
6 January 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5791284
7 March 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4814058
17 January 2012
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4229696
28 September 2010
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3858302
19 January 2010
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3664704
12 January 2009
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3397136
22 September 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3330379
8 August 2008
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3295147
11 July 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3283072
10 October 2007
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3076698
3 January 2007
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850391
5 October 2006
Hull Examination · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2794274
22 September 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2794578
6 July 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2716841
31 March 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2613547
3 January 2006
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2557146
14 September 2005
Type not recorded
No type recorded · USCGC HAWK (WPB 87355) · USCG Heartland District (CGD-H) · Activity 2573991
31 May 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2375406
7 February 2005
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307304
4 January 2005
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2263605
30 August 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2181535
23 February 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2012154
16 December 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1958298
19 March 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1759931
13 February 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1743550
5 November 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1711382
10 October 2002
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1684454
5 February 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1484581
7 January 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1479203
9 November 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384922
28 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062438
1 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057873
12 October 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1473103
13 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 65923
13 July 2000
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 819761
9 December 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 812312
12 October 1999
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464236
25 May 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1436255
15 January 1999
Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 1508972
29 October 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1402834
28 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 161026
11 December 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390734
25 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1116474
27 May 1997
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447793
21 April 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 753386
16 April 1997
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371757
15 April 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 198173
11 October 1996
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398551
3 June 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1086310
21 November 1995
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879387
4 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 39933
4 August 1995
Examination of Repairs · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461659
11 May 1995
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 871013
6 December 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1148331
29 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 128307
21 January 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 851984
22 November 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1158351
13 July 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 845898
25 May 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150206
25 March 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 833497
5 February 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1136746
24 November 1992
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1141934
9 December 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1265747
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1249270
16 July 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937378
20 May 1991
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227215
27 February 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238360
16 January 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1237726
17 December 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214939
12 July 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899454
5 December 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228654
17 November 1989
Initial Construction-Excluding Oversight · Inclining Experiment · Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240623
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 March 2026
Resolved
46 CFR 185.726 (e)
Each battery without an expiration date indicated on it or for which the owner or managing operator does not have a record of the expiration date, used in an item of lifesaving equipment, must be replaced during the annual inspection. MI observed that all 05 float light batteries didn't have expiration date and had wrong battery as per manufacturer instructions.
CODE 705: Vessel is restricted to daytime operations.
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: Batteries were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2026
Resolved
46 CFR 185.604(h)
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant MI observed multiple adult size life jackets that need new Type I retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2026
Resolved 20 April 2026
Resolution: Type I retroreflective material was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 March 2026
Resolved
46 CFR 182.100
All machinery and equipment must be installed and
maintained in such a manner as to afford adequate
protection from causing fire, explosion, machinery
failure, and personnel injury. MI observed both steering
ram hose connections had small leaks.
Action required: 10 - Deficiency Rectified
Due 16 March 2026
Resolved 16 March 2026
Resolution: Connections were tightened.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 March 2026
Resolved
46CFR176.500(b)
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after the each anniversary date. Vessels anniversary date was 19SEP2024, and vessel is past 3 months from said date.
Vessel shall not operate with passengers until an annual inspection has been complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2026
Resolution: Completed annual inspetion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2026
Resolved
46 CFR 182.200 (a)
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. O/O is replacing both main engines. Engines are being replaced in kind. Vessel must demonstrate operation of new main engines to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2026
Resolution: Witnessed operational test of new engines.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 January 2025
Resolved
46 CFR 181.405(c); 705c
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Inspector observed missing fire detection system on top deck for passenger accommodations. Restricted to no overnight voyages until installed.
Action required: 705 - Other - as specified
Resolved 9 February 2025
Resolution: Reviewed photographs sent by vessel rep [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2025
Resolved
46 CFR 181.120(a); 16c
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Inspector observed 01 extra fire extinguisher not serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2025
Resolution: Reviewed photos sent by vessel rep [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 January 2025
Resolved
46 CFR 185.604(b); 16c
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Inspector observed vessel's name not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2025
Resolution: Reviewed photos sent by vessel rep [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2025
Resolved
46 CFR 182.410 (d)1; 16c
Double hose clamping is required where practicable. Inspector observed fuel service hoses in machinery spaces not attached with double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2025
Resolution: Reviewed photos sent by vessel rep [name withheld]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 January 2025
Resolved
46 CFR 179.320(c); 16c
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Inspector observed 02 penetrations in STBD void and within machinery spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2025
Resolution: Reviewed photos sent by vessel rep [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 January 2025
Resolved
46 CFR 183.200(b); 16c
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Inspector observed exposed wires terminating without connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2025
Resolution: Reviewed photos sent by vessel rep [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2023
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements and capable of operating at constant marine load without exceeding its design limitations.
MI observed a water leak on the port main engine where the exhaust header at turbo charger meets the exhaust piping (wet system).
Repair by next planned drydock on 08JAN23.
46 CFR 182.05-1(a)
Action required: 705 - Other - as specified
Due 8 January 2024
Resolved 1 February 2024
Resolution: MI observed installation of newly fabricated exhaust riser. Turbo charger was replaced with new. Ran port main engine for approximately five minutes and observed proper functioning with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 December 2023
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended.
MI observed damaged and missing exhaust pipe lagging for the port auxiliary generator.
Repair by next planned drydock on 08JAN23.
46 CFR 182.10-1
Action required: 705 - Other - as specified
Due 8 January 2024
Resolved 1 February 2024
Resolution: MI observed new exhaust lagging wrap for port auxiliary generator.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 October 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel shall install system to the satisfaction of attending USCG Marine Inspector.
46 CFR 181.405(c) - 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2023
Resolved 12 December 2023
Resolution: MI verified proper operation of interconnected fire detection system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2023
Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector.
46 CFR 185.364 - 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2023
Resolved 12 December 2023
Resolution: MI verified vessel operators had restriction policy/procedures in place for allowing customers to plug in portable devices.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 October 2023
Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessels with a keel laid date after March 28, 2022, must include plans for the monitoring device(s) within the plan submissions required in 46 CFR 177.202. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. The monitoring device(s) must: (1) Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive; (2) Remain operable during the nighttime watch; and (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards.
46 CFR 185.410(b) - 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2023
Resolved 12 December 2023
Resolution: MI verified proper operation of watchman monitoring system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2023
Resolved
(d) Where rigid nonmetallic material (plastic) is permitted for use in piping systems by this section, the following restrictions apply:
(ii) One or more metallic shutoff valves must be installed adjacent to the fitting in one of the following ways:
(A) Only one metallic shutoff valve must be installed if it is operable from above the bulkhead deck;
(B) If two metallic shutoff valves are installed, one on either side of the bulkhead, they need not be operable from above the bulkhead deck provided immediate access to both is possible; or
(C) Where both plastic and metallic materials are used in piping that penetrates a bulkhead, and the two materials exist entirely on opposite sides of the bulkhead, a metallic shutoff valve must be installed at the bulkhead in the metallic part of the system, with the valve being capable of operation from above the bulkhead deck, or locally if immediate access is possible;MI observed no shutoff valves on either side of the through bulkhead fitting.
46 CFR 182.720 (d)(ii)
Action required: 705 - Other - as specified
Due 19 August 2023
Resolved 24 August 2023
Resolution: Vessel installed metallic shutoff valves on both sides of bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
Vessel notified USCG Sector St. Petersburg that the vessel had a broken waterline in engine room causing flooding while outbound from John's Pass.
The vessel shall make satisfactory repairs and contact USCG MI to attend the vessel.
46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2023
Resolved 12 August 2023
Resolution: Vessel representative made satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square.
During inspection Life jacket storage did not have any labeling.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 10 November 2022
Resolution: Vessel representative [name withheld] contacted SSP Dispatch via email with pictures showing the labeling has been put in place for the life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
First-aid kit on board the vessel did not have a tourniquet.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 10 November 2022
Resolution: Vessel representative [name withheld] contacted SSP Dispatch via email with pictures showing the deficiencies have been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge , Marine Inspection.
During inspection multiple electrical wires had been pulled out of their holders or cable runs and were hanging low enough to become a hazard on the 2nd deck.
46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 10 November 2022
Resolution: Vessel representative [name withheld] contacted SSP Dispatch via email with pictures showing the deficiencies have been rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2022
Resolved
All vessels except non self propelled vessels shall be provided with a suitable steering apparatus.
Helm wheel was not tight and had tape on nut holding it on. Helm was loose and wobbling during operation.
46 CFR 183.30-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 10 November 2022
Resolution: Vessel representative [name withheld] contacted SSP Dispatch via email with pictures showing the deficiencies have been rectified.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 October 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without OCMI approval.
Vessel master notified USCG Sector St. Pete after the vessel allegedly ran aground in the channel at John's Pass, St. Pete, FL on October 30, 2022. The vessel returned to the dock and the master stated that the starboard shaft was vibrating on the return trip. A diver confirmed that the starboard (4 blade) propeller was bent at a 90 degree angle on three of the four blades.
The operator shall make satisfactory repairs or replace the propeller in kind and contact USCG MI to attend for a sea trial after repairs are complete.
46 CFR 176.700
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2022
Resolved 1 November 2022
Resolution: A marine inspector attended the vessel and witnessed main engine operation while underway. An ISE was completed by the MI with no deficiencies noted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 January 2022
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangements of each vessel are such as to provide for the safe operation in accordance with the terms of its Certificate of Inspection. Primary consideration shall be given to the provision of a seaworthy hull.
The 1, 2 and 3 overhead longitudinal main deck support frames located inboard from the hatch in the forward starboard compartment were found fractured at the weld to the collision bulkhead.
46 CFR 177.01-5 (Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: The operator cropped and renewed the weld using like and in kind filler metal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2022
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
The Starboard side generator is missing its belt guard.
46 CFR 177.35-15 (Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: The operator placed an original OEM guard over the generator belt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2022
Resolved
It is intended that all machinery be installed an maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
The wet exhaust on the Starboard side main engine has a leak on the inboard side.
46 CFR 182.01-5 (Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: The operator removed the lagging and tightened the metal clamp holding the rubber gasket in this area. The main engine was tested and is no longer leaking. The lagging was placed back over the area.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 January 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure.
The wiring to the air conditioning unit water pump has twist-on wire nuts to make the connection, and it is not inside of an enclosure.
46 CFR 183.340(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: The operator installed a UL listed enclosure for the conductor connection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without OCMI approval. Vessel master notified USCG Sector St. Pete after vessel allegedly ran aground in the channel at John's Pass, St. Pete, FL on Feb. 4, 2021. The vessel returned to the dock and the master stated that the starboard shaft was vibrating on the return trip. A diver confirmed that the starboard (4 blade) propeller was bent at a 90 degree angle on two of the four blades. The operator shall make satisfactory repairs or replace the propeller in kind and contact USCG MI to attend for a sea trial after repairs are complete.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2021
Resolved 5 February 2021
Resolution: O/O replaced prop and MI verified proper installation and conducted sea trials, all SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 January 2021
Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Identified fractured welds in the overhead stiffners located port side #1 forward space. Overhead stiffners located at the cross deck, stiffners #1, #2, #3; numbering of stiffners from outboard to inboard. Forward welds on stiffners fractured, aft welds appeared satisfactory. Operator to renew in kind. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 28 January 2021
Resolution: The operator cropped and renewed the fractured welds. Operator used 5356 filler metal (MIG) for repair weld. Reviewed photos submitted of the weld with no deficiencies noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 January 2020
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied a any point in and direction. The starboard deck rail, above the engine room is cracked. Repair as original.
46 CFR 177.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 10 January 2020
Resolution: Rail repaired and found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 January 2020
Resolved
Whenever damage or deterioration to hull plating g or structural members that may affect the seaworthiness of a vessel is discovered the cognizant OCMI may require the vessel to effect permanent repairs. The port generator exhaust is cracked where the pipes meets the hull. Repair as original.
46 CFR 176.600(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 10 January 2020
Resolution: Area repaired as original.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2020
Resolved
All cable and wire must: be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner to avoid chafing and other damage. The hot water heater electrical supply wires were supported by other wires and not their own metal supports.
46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 10 January 2020
Resolution: Operator installed supports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2019
Resolved
Propulsion machinery must be suitable in type and design
for propulsion requirements of the hull in which it is
installed and capable of operating at constant marine
load under such requirements without exceeding its
designed limitations.
Vessel's port main engine experienced electric starter
failure. Repair and prove proper operation in the
presence of a USCG Marine Inspector.
IAW: 46 CFR 182.200(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2019
Resolution: Vessel representative replaced port main diesel engine electric starter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2019
Resolved
Distribution panel was not drip proof protected.
46CFR183.10-10
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 10 January 2019
Resolution: Owner provided evidence of covers over distribution panel to ensure it is drip proof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2019
Resolved
Packing sleeve leak on shaft. Raw water pipe leak on starboard engine.
46CFR176.800
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 10 January 2019
Resolution: Owner provided evidence of tightened shaft sleeve packing and raw water pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2018
Resolved
Provide operational test of port main transmission to the satisfaction of the Marine Inspector prior to the carry of passengers.
IAW 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2018
Resolution: O/O installed rebuilt transmission for port engine and conducted satisfactory operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 September 2018
Resolved
Piping used in a vital system must be composed of ferrous metal except when non-metallic piping material is permitted by 46 CFR 185.720(e). Found non metallic materials used in bilge piping system (flex hose). Make repairs to bilge piping as original or as required. 46 CFR 182.710(c)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2018
Resolved 3 October 2018
Resolution: Operator completed bilge piping repairs using 1.5 inch stainless steel in port side tool void. Use of stainless steel was previously accepted for same repair on starboard side.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 August 2018
Resolved
A vessel must be provided with a main steering gear that is
of adequate strength and capable of steering the vessel at all service speeds. Make repairs and prove proper operation of steering gear. 46 CFR §182.610.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2018
Resolution: Replaced steering gear pump; witnessed satisfactory operation.
Lifesaving › Lifefloat › Serviceable
Issued 10 October 2017
Resolved
Replace 02 life floats in kind and reduce manning to 40 pax 4 crew iaw 46CFR180,10-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: New life floats installed to the satisfaction of attending inspectors.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 October 2017
Resolved
Repair/Replace port fuel shutoff iaw 46CFR182.20-4(3) prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2017
Resolution: Repair made to port fuel shut off prior to departure of attending marine inspectors.
Engineering › Bilge Water Management System › Valve
Issued 10 January 2017
Resolved
Provide valve handle for stbd side a/c void through hull fitting. 46 CFR 179.350
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 24 January 2017
Resolution: Handle provided and installed to the Inspector satisfaction.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 January 2017
Resolved
Provide globe for lighting in port side tool room. 46 CFR 183.410
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 24 January 2017
Resolution: Globe provided and installed to the Inspector satisfaction.
Operations/Management › Passenger Operations › Safety Orientation
Issued 10 January 2017
Resolved
Label upper deck capacity (63). 46 CFR 185.602(g)
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 24 January 2017
Resolution: Label placed at stairway going towards upper deck to the Inspector satisfaction.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 January 2017
Resolved
Provide voyage plan for overnight voyages. 46 CFR 185.503
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 24 January 2017
Resolution: Voyage Plan provided to the Inspector satisfaction.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 November 2016
Resolved
Remove temporary repair to cracked weld on starboard MDE exhaust piping. Make permanent repairs to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 December 2016
Resolved 9 December 2016
Resolution: Weld was ground back and area; new weld tested satisfactorily with no leaks.
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 September 2016
Resolved
Crop and renew wasted and holed aft bulkhead at main engine exhaust piping penetration, port and starboard sides.
Action required: 705 - Other - as specified
Resolved 11 October 2016
Resolution: Piping cropped and renewed as original; witnessed satisfactory weld test.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 September 2016
Resolved
Make repairs to cracked cap rail main deck starboard side aft.
Action required: 705 - Other - as specified
Resolved 22 September 2016
Resolution: Crack ground back and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 September 2016
Resolved
Crop and renew wasted and holed starboard side aft engine room bulkhead as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New 5086 aluminum alloy plate inserted and welded using 5356 wire; inspected satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 15 September 2016
Resolved
Prove integrity of starboard side engine room aft bilge pipe at flange.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New pipe, gasket and bolts installed; inspected satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2016
Resolved
Crop and renew wasted side shell plating starboard side engine room as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New 5086 aluminum plate inserted and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Structures › Door
Issued 15 September 2016
Resolved
Make repairs to cracked weld main deck forward door and cracked weld above door frame as identified.
Action required: 705 - Other - as specified
Resolved 31 October 2016
Resolution: Crack ground back and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2016
Resolved
Crop and renew wasted and holed main deck plating forward in way of anchor.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New aluminum plate inserted using aluminum backing plates for 100% penetration; inspected satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 September 2016
Resolved
Crop and renew port engine room aft bulkhead in area of excessive pitting as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New 5086 aluminum alloy plate inserted and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Hull › Stringer
Issued 15 September 2016
Resolved
Make repiars to cracked internal side shell weld, port side engine room as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Ground back and welded using 5356 wire; inspected satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 15 September 2016
Resolved
Make repairs to cracked welds on framing under port MDE.
Action required: 705 - Other - as specified
Resolved 11 October 2016
Resolution: Ground back and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2016
Resolved
Crop and renew wasted and pitted side shell in port side engine room as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New 5086 aluminum alloy plate inserted and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2016
Resolved
Crop and renew wasted and pitted side shell long frames in port engine room as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New aluminum frames alloy plate inserted and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 September 2016
Resolved
Crop and renew wasted and pitted port side forward engine room bulkhead as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New 5086 aluminum plate inserted and welded using 5356 wire; inspected satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2016
Resolved
Crop and renew wasted and pitted side shell in port side fuel tank compartment as identified.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New 5086 aluminum plate inserted and welded using 5356 wire; inspected satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 January 2016
Resolved
Properly place belt guards on generators IAW 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 17 February 2016
Documentation › Markings/Placards › Capacity Marking
Issued 6 January 2016
Resolved
Re-stencil marking for top deck passenger capacity.
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 17 February 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 6 January 2016
Resolved
Ensure new blank is properly installed in stbd electrical panel IAW 46 CFR 183.200.
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 17 February 2016
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 6 January 2016
Resolved
Ensure hole in port side engine exhaust is welded properly IAW 46 CFR 182.220.
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 17 February 2016
Lifesaving › Lifefloat › Markings
Issued 19 January 2010
Resolved
Renew name on lifefloats (4).
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Lifesaving › Lifefloat › Paddle
Issued 19 January 2010
Resolved
Renew name on paddles and replace (1) paddle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2010
Lifesaving › Lifefloat › Lifeline
Issued 19 January 2010
Resolved
Replace tie-wraps on lifefloat grab lines w/ suitable releasable material. No electrical ties.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 January 2010
Resolved
Replace batteries in all waterlights. (4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2010
Lifesaving › Lifefloat › Lifeline
Issued 19 January 2010
Resolved
Replace nylon line as needed on all lifefloats.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 January 2010
Resolved
Replace missing covers on juction boxes in stbd and port engine rooms.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 January 2010
Resolved
Cover hole on juction box in stbd engine room.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 January 2010
Resolved
Properly secure battery box covers.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 January 2010
Resolved
Replace eye wash in first aid kit.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Navigation › Piloting/Steering › Marine Charts
Issued 19 January 2010
Resolved
Provide updated charts for area navigated.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 January 2010
Resolved
Replace fuel cap on fill tube.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Engineering › Fuel Oil Service System › Filter
Issued 19 January 2010
Resolved
Replace fuel bowl on port side maine engine fuel filter housing.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 4 February 2010
Engineering › Bilge Water Management System › Pump
Issued 12 January 2009
Resolved
Renew/repair inoperable Port bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2008
Resolved
Make permanent repairs to stbd exhaust pipe.
Due 15 August 2008
Resolved 15 August 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 August 2008
Resolved
The vsl is limited to no more than 20 miles from shore until proper operation of the MF radio can be proven.
Action required: 705 - Other - as specified
Resolved 8 August 2008
Resolution: Antenna wire was reconnected.
Engineering › Steering Gear System › Rudder Stock
Issued 8 August 2008
Resolved
Tighten port rudder post packing.
Due 15 August 2008
Resolved 15 August 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 August 2008
Resolved
Make permanent repairs to MSD/LIVEWELL through hull connection.
Due 15 August 2008
Resolved 15 August 2008
Stability › Watertight Integrity › General
Issued 8 August 2008
Resolved
Make hatch IWO port engineroom watertight.
Due 15 August 2008
Resolved 15 August 2008
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2008
Resolved
Make permanent electrical connection on P/W pump.
Due 15 August 2008
Resolved 15 August 2008
Electrical › Electric Generation Source (service) › Generator
Issued 8 August 2008
Resolved
Install belt guard on port generator.
Due 15 August 2008
Resolved 15 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2008
Resolved
Install double hose clamps on exhaust hose IWO stbd lazaret.
Due 15 August 2008
Resolved 15 August 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 8 August 2008
Resolved
Remove extension cords from bridge.
Due 15 August 2008
Resolved 15 August 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 October 2007
Resolved
Provide ammonia capsule and aluminum splint in first aid kit.
Condition: Improper/Lack of Maintenance
Due 24 October 2007
Resolved 6 November 2007
Lifesaving › Lifefloat › Serviceable
Issued 10 October 2007
Resolved
Repair crack//tear in lifefloat, replace retro tape as needed, stencil full vessel name on raft, provide 100 feet of painter lne for each lifefloat.
Condition: Improper/Lack of Maintenance
Due 17 October 2007
Resolved 22 October 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 10 October 2007
Resolved
Replace fuel hose on port generator with SAE J-1942 fuel hose.
Condition: Improper/Lack of Maintenance
Due 24 October 2007
Resolved 6 November 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 October 2007
Resolved
Provide lock nuts on all battery connections.
Condition: Improper/Lack of Maintenance
Due 17 October 2007
Resolved 6 November 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 10 October 2007
Resolved
Label engine room hatches with "Emergency Exit, Keep Clear."
Condition: Improper/Lack of Maintenance
Due 24 October 2007
Resolved 6 November 2007
Engineering › Bilge Water Management System › Pump
Issued 10 October 2007
Resolved
Provide hand pump in accordance with 46CFR183.2510(a)
Condition: Improper/Lack of Maintenance
Due 24 October 2007
Resolved 22 October 2007
Resolution: Vessel representative faxed in a copy of a purchase receipt for a hand bilge pump.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 October 2007
Resolved
Repair emergency lighting in engine room.
Condition: Improper/Lack of Maintenance
Due 24 October 2007
Resolved 6 November 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 October 2007
Resolved
Provide 01 B-II portable dry chemical fire extinguisher to engine room.
Condition: Improper/Lack of Maintenance
Due 17 October 2007
Resolved 6 November 2007
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 3 January 2007
Resolved
Provide the vessel with an updated Navigation Rules publication.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Communications › Audible Communications › Bell
Issued 3 January 2007
Resolved
Provide the vessel with a ship's bell of appropriate size.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 January 2007
Resolved
Provide (5) additional adult life jackets, vessel is restricted to 142 total persons until additional life jackets are provided.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 January 2007
Resolved
Provide a water light for the life float prior to conducting night time operations.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Lifesaving › Lifefloat › Markings
Issued 3 January 2007
Resolved
Properly stencil life floats as needed due to fading.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 3 January 2007
Resolved
Renew the reflective tape on the life floats as needed.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Fire Fighting › Fire Pumps › Pressure
Issued 3 January 2007
Resolved
Replace the pressure gauge on the port fire pump.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Engineering › Fuel Oil Service System › Hose
Issued 3 January 2007
Resolved
Replace one fuel hose on the stbd generator.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 24 January 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 January 2007
Resolved
Prior to getting underway repair the leak in the sea suction piping on the stbd main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 4 January 2007
Communications › Radio Communications › EPIRB
Issued 3 January 2007
Resolved
Replace the expired battery in the EPIRB, the vessel is restricted to within 3 miles from shore until the battery has been renewed.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 5 January 2007
Engineering › Bilge Water Management System › Pump
Issued 5 October 2006
Resolved
Remove 12 volt sump pumps in the port and stbd engine room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2006
Resolved 23 October 2006
Resolution: REMOVED
Engineering › Bilge Water Management System › Piping
Issued 5 October 2006
Resolved
Make repairs and prove proper operation of the bilge piping system, it has numerous fittings that are leaking and the system is unable to take suction.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2006
Resolved 23 October 2006
Resolution: CORRECTED AND TESTED SAT
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 October 2006
Resolved
Make repairs to (4) pipe penetrations for the bait tank supply lines leading forward IWO the forward and aft BHD's in the #2 STBD void as they failed a hose test.
Action required: 705 - Other - as specified
Due 20 November 2006
Resolved 23 October 2006
Resolution: ALL SEALED AND TESTED SAT
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 January 2006
Resolved
Replace fire extinguisher on upper passenger deck.
Due 10 January 2006
Resolved 13 January 2006
Resolution: Completed.
Lifesaving › Lifefloat › Paddle
Issued 3 January 2006
Resolved
Provide 2 four foot paddles for each lifefloat.
Due 10 January 2006
Resolved 13 January 2006
Resolution: All ne paddels have been installed and labeled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 January 2006
Resolved
Replace two of four floatng electric waterlights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2006
Resolution: Ne lights were purchased.
Lifesaving › Lifefloat › Serviceable
Issued 3 January 2006
Resolved
Repair crack in body of lifefloat. Lifefloat lot # 113.
Condition: Unknown
Due 10 January 2006
Resolved 13 January 2006
Resolution: Reapairs were made IAW [name withheld].
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 January 2006
Resolved
Post lifejacket donning instructions on upper passenger deck.
Due 10 January 2006
Resolved 13 January 2006
Resolution: Donning plackard was posted on top deck.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 3 January 2006
Resolved
Provide updated compass deviation table.
Due 10 January 2006
Resolved 10 March 2006
Resolution: RECEIVED A FAX ATTESTING TO THE COMPASS CORRECTION INSPECTION.
Documentation › Certificates/Documents › FCC SSL
Issued 3 January 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 31 January 2006
Resolved 21 February 2006
Resolution: VIEWED LICENSE, WDC8614, UPDATED RECORD
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 January 2006
Resolved
Make permanent repairs to starboard navigation light power supply cable prior to operating at night or at times of reduced visibility. A jumper cable was installed leading from the mast power distribution box across the exterior of the top of the pilot house leading to the navigation light.
Action required: 705 - Other - as specified
Resolved 13 January 2006
Resolution: Re-wired, SAT.
Engineering › Steering Gear System › Rudder Stock
Issued 3 January 2006
Resolved
Make permanent repairs to holed/leaking starboard rudder post
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2006
Resolution: Completed. See file for pictures.
Stability › Watertight Integrity › General
Issued 3 January 2006
Resolved
Provide valves for non-metallic piping penetrating watertight bulkheads.
Action required: 705 - Other - as specified
Due 17 January 2006
Resolved 21 February 2006
Resolution: PIPING WAS REMOVED AND CAPPED OFF.
Engineering › Bilge Water Management System › Valve
Issued 3 January 2006
Resolved
Provide check valves for each bilge suction line or replace existing manifold valves w/ stop-check valves.
Action required: 705 - Other - as specified
Due 17 January 2006
Resolved 13 January 2006
Resolution: New check valve have been installed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 3 January 2006
Resolved
Immediately tighten packing gland. Replace packing gland.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 13 January 2006
Resolution: Completed.
Fire Fighting › Fire Pumps › Capacity
Issued 3 January 2006
Resolved
Provide pump pressure not less than 60psi prior to the carriage of more than 49 passengers.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Resolution: WITNESSED A SATISFACTORY STREAM IAW 46CFR181.10-1(b).
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 4 January 2005
Resolved
Provide a horn IAW 33CFR Part 86.
Condition: Placed in Improper Service
Due 4 February 2005
Resolved 1 March 2005
Lifesaving › Hand Flares › Storage
Issued 4 January 2005
Resolved
Relabel flare box.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 January 2005
Resolved
Update first aid kit.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Lifesaving › Lifefloat › Serviceable
Issued 4 January 2005
Resolved
Replace bottom two life floats.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 January 2005
Resolved
Repair float light for PORT bottom LF.
Condition: Improper/Lack of Maintenance
Due 4 January 2005
Resolved 4 January 2005
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 4 January 2005
Resolved
Provide a panel plug in missing breaker hole IAW STBD engine room electrical panel, outboard.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2005
Resolved
Mount hanging light IWO STBD engine room by genset.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Engineering › Fuel Oil Service System › Valve
Issued 4 January 2005
Resolved
Relocate all fuel oil stop valves from under engines to a location that is close to the engine and accessable.
Condition: Placed in Improper Service
Due 4 February 2005
Resolved 1 March 2005
Lifesaving › Lifebuoys › Approval
Issued 4 January 2005
Resolved
Replace ring life buoy and stow IAW 46CFR180.70.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Fire Fighting › Fire Main › Condition
Issued 4 January 2005
Resolved
Locate and repair water leak coming from fire main piping in the PORT engine room OVHD.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Engineering › Fuel Oil Service System › Piping
Issued 4 January 2005
Resolved
Repair fuel leak in flame bowl on the STBD genset racor filter.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2005
Resolved
Remove all unused wires in both engine rooms.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2005
Resolved
Re-wire or properly wire all wires to batteries. (Found a few main leads spliced together. Wires going through deck holes with no chaffing. No inline fuses from batteries)
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Engineering › Fuel Oil Service System › Piping
Issued 4 January 2005
Resolved
Replace racor filter plastic plug with metallic plug and repair leak on PORT genset.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 4 January 2005
Resolved
Attach all deck hatch lanyards.
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 1 March 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2005
Resolved
Provide a grab rail for deck hands to hold onto while walking along the outside of the second deck to get to the life floats.
Condition: Placed in Improper Service
Due 4 February 2005
Resolved 1 March 2005
Navigation › Piloting/Steering
Issued 16 December 2003
Resolved
Rebuild or replace STBD steering ram. LEGACY COMPONENT DESC: Steering Ram
Condition: Improper/Lack of Maintenance
Due 30 January 2004
Resolved 23 February 2004
Navigation › Piloting/Steering
Issued 16 December 2003
Resolved
Replace all wasted hydraulic fittings on both PORT and STBD steering rams/system as discussed. LEGACY COMPONENT DESC: Hydraulic fittings
Condition: Improper/Lack of Maintenance
Due 30 January 2004
Resolved 23 February 2004
Electrical › Electric Generation Source (service)
Issued 16 December 2003
Resolved
Replace all worn/wasted fuel, water, and oil fittings on PORT genset. LEGACY COMPONENT DESC: Number of Sources
Condition: Improper/Lack of Maintenance
Due 16 February 2004
Resolved 23 February 2004
Electrical › Electric Generation Source (service)
Issued 16 December 2003
Resolved
Replace PORT genset exhaust manifold. LEGACY COMPONENT DESC: Exhaust manifold
Condition: Improper/Lack of Maintenance
Due 16 February 2004
Resolved 23 February 2004
Navigation › Piloting/Steering
Issued 16 December 2003
Resolved
Replace PORT steering ram-to-tiller pin. LEGACY COMPONENT DESC: Ram pin
Condition: Improper/Lack of Maintenance
Due 30 January 2004
Resolved 23 February 2004
Engineering › Bilge Water Management System
Issued 16 December 2003
Resolved
Replace STBD collision BLKHD bilge valve IWO FWD void. LEGACY COMPONENT DESC: Collision BLKHD valve
Condition: Improper/Lack of Maintenance
Due 30 January 2004
Resolved 23 February 2004
Fire Fighting › Fire Hoses
Issued 16 December 2003
Resolved
Prior to the carriage of passengers, provide two nozzles for hoses. LEGACY COMPONENT DESC: Nozzles
Condition: Improper/Lack of Maintenance
Due 16 December 2003
Resolved 16 December 2003
Navigation › Piloting/Steering
Issued 16 December 2003
Resolved
Prior to the carriage of passengers, replace stern light. LEGACY COMPONENT DESC: Nav lights
Condition: Improper/Lack of Maintenance
Due 16 December 2003
Resolved 16 December 2003
Lifesaving › Lifejacket/PFD (General)
Issued 16 December 2003
Resolved
Properly label lifejacket stowage areas (Type and # of lifejackets). LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 23 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2003
Resolved
Secure deck plates throughout bilge areas as discussed. LEGACY COMPONENT DESC: Deck plates
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 23 February 2004
Engineering › Bilge Water Management System
Issued 13 February 2003
Resolved
INSTALL SAE J-1942 HOSE WITH BARBED FITTINGS ON ALL BILGE PIPE SPLICES OR HARD PIPE AS ORIGINAL. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 24 March 2003
Resolved 16 December 2003
Operations/Management › Drills/Instruction
Issued 10 October 2002
Resolved
CONDUCT U/W MAN OVERBOARD DRILL. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 10 November 2002
Resolved 25 October 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 October 2002
Resolved
PROVIDE 5 CURRENTLY CERTIFIED B-II FIRE EXTINGUISHERS PRIOR TP CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Service
Due 11 October 2002
Resolved 11 October 2002
Resolution: INSTALLED BY RESCUE ONE FIRE SYSTEMS.
Engineering › Bilge Water Management System
Issued 10 October 2002
Resolved
REPAIR PORT TOOL ROOM AND STBD A/C ROOM HIGH LEVEL BILGE ALARMS PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Alarms
Condition: Improper/Lack of Maintenance
Due 11 October 2002
Resolved 11 October 2002
Resolution: REPLACED FLOAT SWITCHES.
Engineering › Bilge Water Management System › Valve
Issued 10 October 2002
Resolved
PROVE PROPER OPERATION OF STBD FOREPEAK BILGE MANIFOLD SYSTEM PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Improper/Lack of Maintenance
Due 11 October 2002
Resolved 11 October 2002
Resolution: CHECK VALVE FROZEN. REMOVED AND REPAIRED.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 October 2002
Resolved
REPAIR CRACKED PORT BRIDGE WINDOW. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Due 10 November 2002
Resolved 5 November 2002
Resolution: WITNESSED INSTALLATION.
Lifesaving › Buoyant Apparatus
Issued 7 January 2002
Resolved
REPAIR FOUR LIFEFLOAT DROP NETS (DRY ROT) .
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 5 February 2002
Resolution: INSTALLED 2 NEW LIFEFLOATS AND 2 NEW DROP NETS.
Navigation › Electronic Positioning
Issued 7 January 2002
Resolved
PROPERLY INSTALL 406 MHZ CAT 1 EPIRB IN FLOAT FREE POSITION PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Radio Direction Finding Device
Condition: Improper Installation
Due 21 January 2002
Resolved 8 January 2002
Resolution: INSTALLED NEW EPIRB.
Fire Fighting › Fire Pumps
Issued 7 January 2002
Resolved
INSTALL PRESSURE GAUGE ON DISCHARGE SIDE OF ELECTRIC FIRE PUMP AND PROVE PROPER DISCHARGE PRESSURE. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Due 21 January 2002
Resolved 5 February 2002
Resolution: GUAGE INSTALLED.
Engineering › Fuel Oil Service System
Issued 7 January 2002
Resolved
INSTALL FLAME BOWL ON FUEL STRAINER. LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 5 February 2002
Documentation
Issued 1 February 2001
Resolved
PROVIDE DOCUMENTATION OF ANNUAL USER FEE PAYMENT.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Lifesaving
Issued 1 February 2001
Resolved
DEMONSTRATE RETRIEVAL OF HELPLESS PERSON FROM THE WATER.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Engineering
Issued 12 October 2000
Resolved
REPLACE PORT/STBD FLAME SCREENS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Lifesaving
Issued 12 October 2000
Resolved
DEMONSTRATE RETRIEVAL OF A HELPLESS PERSON FROM THE WATER.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Lifesaving
Issued 12 October 2000
Resolved
REPLACE TETHER LINE ON STARBOARD LIFEFLOATS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Construction/Loadline
Issued 12 October 2000
Resolved
REPAIR PORT FOREPEAK BILGE REACH ROD.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Navigation
Issued 12 October 2000
Resolved
REPLACE STARBOARD RUNNING LIGHT PRIOR TO OPERATION WITH PASSENGERS AT NIGHT.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Construction/Loadline
Issued 13 July 2000
Resolved
MAKE PERMANENT REPAIRS TO PORT HULL/DECK IN WAY OF BOW PRIOR TO CARRIAGE OFPASSENGERS.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Lifesaving
Issued 12 October 1999
Resolved
REPLACE 06 RED HAND HELD FLARES PRIOR TO SAILING.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 12 October 1999
Resolved
INSTALL HIGH LEVEL BILGE ALARMS IAW 46CFR182.530
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
INSTALL TIP ON O1 FIRE NOZZLE. ENSURE TIP AND NOZZLE ARE TEATHERED TOGETHER PRIOR TO SAILING.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Documentation
Issued 12 October 1999
Resolved
INITIATE EPIRB AND SAFETY EQUIPMENT LOGS.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
INSTALL SPANNER WRENCHES ON FIRE PLUGS PRIOR TO SAILING.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS PRIOR TO SAILING.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 25 May 1999
Resolved
REPAIR CRACKED WELDS IWO: FRAME #2 VERT STIFFENERS TIE-IN TO DECK LONGITUDINAL STIFFENERS 1-7 PORTSIDE; WTB #1 STBD SIDE TIE-IN TO HORIZ STIFFENER. COMPLETE REPAIRS/INSTALL PORT RUDDER HOUSING, ADJUST STBD RUDDER HOUSING.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Electrical
Issued 25 May 1999
Resolved
REMOVE ALL DEAD END WIRING. ENSURE ALL WIRING IS SECURELY FASTENED AT LOAD AND DISTRIBUTION ENDS OF CONDUCTOR. REMOVE ALL DAMAGED WIRING AND REPLACE WITH APPROVED WIRING. REPLACE STBD GENERATOR START MOTOR NEG CONDUCTOR. REPAIR GENERATOR PANEL DOOR.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Construction/Loadline
Issued 25 May 1999
Resolved
REPAIR AFT WTB IN COMPT #2 IWO COPPER PIPING PENETRATION. WELD PITS IN WTB #2 HORIZONTAL STIFFENER (ANY PIT >0.0625").
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Electrical
Issued 25 May 1999
Resolved
REMOVE ALL ELEC CONDUCTORS FROM ENG COMPT RATED AT <105 DEG C. PLACE ALL CONDUCTOR CONNECTIONS AND TERMINALS IN ENCLOSURES AND CONNECT IAW 46 CFR 183.340(g).
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Accommodation/Occupational Safety
Issued 29 October 1998
Resolved
REPLACE CRACKED WINDOWS (6).
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 29 October 1998
Resolved
REPAIR BRIDGE DISTRIBUTION PANEL DOOR.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 29 October 1998
Resolved
REMOVE DEAD-END WIRING BENEATH BRIDGE CONSOLE.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 29 October 1998
Resolved
REFURBISH LIFERAFTS SO THAT LIFELINES, PAINTERS, AND COLOR ARE IN COMPLIANCE WITH 46 CFR PART 180.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 11 December 1997
Resolved
SCHEDULE FIRE AND MOB DRILLS, INITIATE THOROUGH LOG KEEPING.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 11 December 1997
Resolved
INSTALL ADEQUATE RETRO-REFLECTIVE MATERIAL ON LIFERING AND LIFERAFTS.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 11 December 1997
Resolved
PROCURE MEANS OF RETREIVING PERSON FROM WATER (LADDER, HOIST, ETC).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 11 December 1997
Resolved
PROVIDE ELECTRICIANS REPORT CONCERNING ADEQUACY OF MODIFIED ELECTRICAL SYSTEM AND WIRING OF GENERATOR TO MAIN SWITCH BOARD.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 11 December 1997
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, POST PFD DONNING INSTRUCTION PLACARD ON MAIN DECK AND IN VICINITY OF PFD STOWAGE ON SECOND DECK.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 11 December 1997
Resolved
ENSURE VSL'S FIRST AID KIT MEETS CONTENTS REQUIREMENTS OF 46 CFR 184.710.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 11 December 1997
Resolved
MARK PFD STOWAGE WITH QUANTITY AND SIZE OF STOWED PFD'S.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 11 December 1997
Resolved
PROCURE ADDITIONAL B-II F/E SO AS TO MEET REQUIRED SEVEN B-II F/E'S, TO BE INSTALLED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Construction/Loadline
Issued 11 December 1997
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, REMOVE OIL FROM E/R BILGES.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 11 December 1997
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, REPLACE BATTERY IN WATERLIGHT.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 27 May 1997
Resolved
PROVIDE DOCUMENTATION DESIGNATING "TC" AND "THHN" CONDUCTORS APPROVED FOR MARINE USE.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Accommodation/Occupational Safety
Issued 27 May 1997
Resolved
INSTALL MACERATOR SYSTEM IN MSD OR PROVIDE LOCKING SYSTEM FOR HEADS.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Construction/Loadline
Issued 27 May 1997
Resolved
REPAIR CRACKED WINDOW IN WTD.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Electrical
Issued 27 May 1997
Resolved
PROVIDE DI-ELECTRIC MAT FOR SWITCH BOARD.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Construction/Loadline
Issued 27 May 1997
Resolved
REPAIR AFT HATCH STBD SIDE.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Electrical
Issued 27 May 1997
Resolved
REMOVE ALL DEAD-END WIRING AND REPLACE ALL DAMAGED WIRING.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Electrical
Issued 27 May 1997
Resolved
PROVIDE TECH REP SERVICING REPORT FOR PORTSIDE GENSET
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Construction/Loadline
Issued 27 May 1997
Resolved
CLOSE ALL WTBHD PENETRATIONS.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Electrical
Issued 27 May 1997
Resolved
REPALCE ALL NYLON WIRING STRAPS WITH ADEQUATE METALLIC STRAPS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Accommodation/Occupational Safety
Issued 27 May 1997
Resolved
CLEAN GALLEY/FOOD SERVICE AREA.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Fire Fighting
Issued 11 October 1996
Resolved
REPLACE MISSING INSULATION ON PORT AND STARBOARD MAIN ENGINE EXHAUSTS AND BOTH ENGINE ROOM OVERHEADS.
Condition: Unknown
Due 11 November 1996
Resolved 20 December 1996
Navigation
Issued 21 November 1995
Resolved
REPLACE EPIRB MOUNTING BRACKET ON TOP OF PILOT HOUSE.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Construction/Loadline
Issued 21 November 1995
Resolved
MAKE PERMANENT REPAIR BY WELDING TO PORT BILGE PUMP AND MSD OVERBOARD DISCHARGE THRU-HULL FITTINGS. MAINTAIN TERMPORARY REPAIRS UNTIL COMPLETE.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Navigation
Issued 21 November 1995
Resolved
REMOVE EXCESSIVE CLEARANCE IN PORT AND STARBOARD RUDDER ARMS TO HYDRAULIC RAM CONNECTION.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Electrical
Issued 21 November 1995
Resolved
STENCIL ALL EMERGENCY LIGHTS WITH A 1" RED 'E'.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Accommodation/Occupational Safety
Issued 21 November 1995
Resolved
CLEAN EXCESSIVE GREASE FROM GALLEY FAN.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Fire Fighting
Issued 4 August 1995
Resolved
Install brackets and mount fire extinguisers at 2 fire stations in the passenger berthing area and 1 in the port engine room.
Condition: Unknown
Due 5 September 1995
Resolved 7 September 1995
Accommodation/Occupational Safety
Issued 22 November 1993
Resolved
Replace broken pilot house window.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Accommodation/Occupational Safety
Issued 25 May 1993
Resolved
Repipe potable water system from pump discharge to flexible hose and provide support for the piping.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Accommodation/Occupational Safety
Issued 25 May 1993
Resolved
Repair leak on raw water pump in stbd lazerette.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993
Resolved
Renew and properly mount moter controller on potable water pump.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Lifesaving
Issued 24 November 1992
Resolved
Seal openings in lifefloats.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Navigation
Issued 24 November 1992
Resolved
Replace key in port rudder quadrant connection to post.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Documentation
Issued 24 November 1992
Resolved
Provide marine document to show coastwise trade.
Condition: Unknown
Due 24 November 1992
Resolved 24 November 1992
Engineering
Issued 24 November 1992
Resolved
Install flame screens on port and starboard fuel vents.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Construction/Loadline
Issued 20 May 1991
Resolved
REPAIR BY WELDING - 6" CRACK IN JOINT BETWEEN TUNNEL AND SIDE SHELL, STBD, 2ND VOID, BETWEEN 2ND AND 3RD FRAMES FROM AFT BHD, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Lifesaving
Issued 17 December 1990
Resolved
PROVIDE ONE ADDITIONAL ADULT PFD WITH LIGHT PRIOR TO CARRYING 145 PASSENGERS.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Navigation
Issued 17 December 1990
Resolved
INSTALL COTTER KEYS ALL STEERING LINKAGE.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Navigation
Issued 17 December 1990
Resolved
CLEAN OIL P&S 2ND COMPARTMENT. FIND LEAK IN STEERING AND REPAIR.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Documentation
Issued 17 December 1990
Resolved
PROVIDE GARBAGE MANAGEMENT PLAN.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Fire Fighting
Issued 5 December 1989
Resolved
PROVIDE A PORTABLE BILGE/FIRE PUMP WITH SUFFICIENT HOSES TO PUMP BILGES OR PUMP WATER TO THE WHEELHOUSE.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Unknown
Issued 17 November 1989
Resolved
PROVIDE PROOF OF STABILITY LETTER FROM MSC.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
PROVIDE PROOF OF RADIO TELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
PROVIDE PROOF OF RADIO STATION LICENSE CERTIFICATE.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989