ISLAND TIME is a 1993 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in May 2026, along with 37 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 13 May 2026.

Built
1993
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

388684
Flag
UNITED STATES
Maury page id
psix-388684

Documentation record

Registered dimensions (L × B × D)64.8 ft × 17.0 ft × 4.0 ft
Registered tonnagegross 94 / net 88
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER/MID-CITY STL · LA CROSSE, WI, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Simplified, Gross Ton
88 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

13 May 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8372868
11 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8370723
10 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8267844
20 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8139562
18 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8036353
7 August 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7976427
25 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7941892
3 June 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7926263
21 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7915766
15 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7714768
24 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7485951
2 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7442586
19 April 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425668
22 September 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7318357
17 May 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7199504
16 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7178365
29 June 2020 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6990885
18 July 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6755477
5 June 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6706021
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512713
10 May 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6414718
8 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6368560
20 April 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6131133
15 March 2017 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6101088
15 March 2017 DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6107950
5 December 2016 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6052434
13 October 2016 Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6025067
12 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5970734
11 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5973179
22 July 2016 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5949254
23 June 2016 Re-Inspection · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5916202
5 February 2016 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5808288

Deficiency record · 37

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2026 Resolved
All electrical installations shall be to the satisfaction of the OCMI. 1. There are two surge traps beneath the operating station that are not secure. 2. Secure the battery box lid beneath the operating station. 3. Secure loose terminal boards in the engine compartment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 22 May 2026
Resolution: all items repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 May 2026 Resolved
All pyrotechnic distress signals shall be stored in a watertight container. The distress signal container is not watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 22 May 2026
Resolution: replaced with proper box.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 May 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must be approved by the Commandant. The "charged" or "normal" light at the operating station is extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 13 May 2026
Resolution: POC provided photographic and video evidence of proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2026 Resolved
A vessel owner, charterer, operator or agent shall immediateley notify the nearest Coast Guard offic whenever an occurence materially and adversely affecting the vessel's seaworthiness occurs. On May 9, 2026 at 2130 the vessel suffered a failure of the gasket in way of the sea strainer inspection lid causing flooding in the #3 port void. Report the same to MSU Chicago Investigations Division.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 May 2026
Resolved 12 May 2026
Resolution: Received notification from SIO MSU Chicago of report of potential marine casualty.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2026 Resolved
Auxiliary machinery shall be suitable for the purpose intended. The gasket for the AC cooling water sea suction sea strainer inspection port is damaged. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 12 May 2026
Resolution: Received photographic and video evidence of completion.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 21 May 2024 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Port main deck salon access area is leaking water into the engine room. Investigate cause of leak and provide repair proposal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 7 August 2024
Resolution: Witnessed satisfactory repair and hose testing of steel deck replacement.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2024 Resolved
(a) A pre-engineered fixed gas fire extinguishing system must: (1) Be approved by the Commandant; (2) Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector; (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and (4) Be installed in accordance with the manufacturer's instructions. The Fireboy cable pull is installed with parts not approved by the manufacturer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
Resolution: Attended vessel and witnessed proper installation of Fireboy system and conducted operational test of alarms and shutdowns.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022 Resolved
Starboard main engine muffler was missing double hose clamps. Provide double hose clamps on muffler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 2 May 2022
Resolution: New clamp installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2022 Resolved
Prove proper operation of audible alarm for high bilge level in the rudder room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 2 May 2022
Resolution: New alarm panel installed, all alarms tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2022 Resolved
Carry no more than 93 total persons until 5 adult type I PFD's are provided onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2022
Resolved 24 June 2022
Resolution: Proof of 5 PFD's provided by photo cleared 835
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 May 2021 Resolved
COD mounted is expired, Provide new/ valid COD to attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: COD was renewed in May 21
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2021 Resolved
Install proper fuel filters on PORT main diesel engine and install metal bowl on genset fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: Metal bowl added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021 Resolved
Install proper ring connectors on battery under bridge console.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: Proper connection added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2021 Resolved
Double clamp all R/W connections on the STBD MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: Clamps added to hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020 Resolved
Wires hanging into bilge in fwd storage area. Remove/mount wires out of bilge area to satisfaction of Marine Inspector. "Old T" 46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 June 2020
Resolution: Wires mounted to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 June 2020 Resolved
Remove/replace oily diapers from underneath propulsion engines and generator prior to carrying passengers. "Old T" 46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2020 Resolved
Plastic expansion tanks for starboard engines are currently mounted with lines hanging off of cables. Mount tank to vessel metal structures with hardware to satisfaction of Marine Inspector. "Old T" 46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 24 July 2020
Resolution: Expansion tank has been mounted to the satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2019 Resolved
Only 1 smoke and 5 flares sidtress signals were valid. Rest were expired, must have 6 each. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Provided 3 smoke and 8 day/night flares
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 June 2019 Resolved
Electronic tablet was not charged and would not load light list or river current publication. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Provided 2 means of electronic copies of all nav pub's
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 June 2019 Resolved
Aft main deck emergency light not working. 46 CFR 183.432
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Replaced bulb tested sat
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 5 June 2019 Resolved
Missing DAPI annual MIS report. 46 CFR 16.500(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Provide doc that showed they had submitted results
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2019 Resolved
Crew not familiar with installed bilge system. Conducted training on the spot. 46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Conducted training on the spot
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting: Invalid MMSI, Invalid Call Sign, no static draft information, and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 10 November 2021
Resolution: Rcvd prrof that AIS info has been added.
Engineering › Bilge Water Management System › Piping
Issued 15 March 2017 Resolved
Fore and aft compartment suction is too slow and loses suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2017
Resolved 20 April 2017
Resolution: Re- Labled upper deck
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2017 Resolved
Install proper cable supports every 23 inches in engine roomWires need to be properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 20 April 2017
Resolution: Installed new metal holders
Stability › Incline Test › General
Issued 15 March 2017 Resolved
Incorrect number of passengers for upper deck listed on placard.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 20 April 2017
Resolution: Re-Label upper deck
Stability › Incline Test › General
Issued 12 August 2016 Resolved
Passenger count has been reduced to 80 pass until new SST is conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 11 October 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 22 July 2016 Resolved
16 adult and 06 children life vests need retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 11 August 2016
Resolution: 16 adult and 06 child lifejackets have had the retro reflective tape renewed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 July 2016 Resolved
Must have B-II fire extinguisher in engine room serviced.
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 11 August 2016
Resolution: B-II fire estinguisher in the engine room had the annaual service completed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 July 2016 Resolved
COD needs to be posted
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 11 August 2016
Resolution: New COD has been posted on board vessel.
Construction/Loadline › Hull › Stiffener
Issued 5 February 2016 Resolved
Rebuild flat bars behind rudder posts for structural stiffness IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 February 2016 Resolved
Renew insert on stbd longitudinal at transom in hull plate IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Stiffener
Issued 5 February 2016 Resolved
Crop and renew wasted flat bars at transom in hull plate in lazarette IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Stability › Watertight Integrity › General
Issued 5 February 2016 Resolved
Renew AC condensation drain in thru hull connection outboard port side transom IAW 46 CFR 176.610.
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Bracket
Issued 5 February 2016 Resolved
Repair wasted tripping brackets port and stbd side of lazarette IAW 46 CFR 176.610.
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Stability › Watertight Integrity › General
Issued 5 February 2016 Resolved
Repair wasted areas of transom on stern/lazarette IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 5 February 2016 Resolved
Gauge areas of concern including stbd side of hull, fwd most compartment, and bar hold IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.

Ownership record