Records from 1993 to 2026. Most recent: inspection, 13 May 2026.
Inspection history · 77
13 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8372868
11 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8370723
10 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8267844
20 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8139562
18 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8036353
7 August 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7976427
25 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7941892
3 June 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7926263
21 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7915766
15 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7714768
24 June 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7485951
2 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7442586
19 April 2022
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425668
22 September 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7318357
17 May 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7199504
16 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7178365
29 June 2020
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6990885
18 July 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6755477
5 June 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6706021
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512713
10 May 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6414718
8 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6368560
20 April 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6131133
15 March 2017
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6101088
15 March 2017
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6107950
5 December 2016
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6052434
13 October 2016
Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6025067
12 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5970734
11 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5973179
22 July 2016
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5949254
23 June 2016
Re-Inspection · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5916202
5 February 2016
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5808288
20 June 2014
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4894329
31 January 2012
Administrative Inspection · COI Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235022
11 January 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4222789
4 March 2010
Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3689929
27 April 2009
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3462947
14 April 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3183600
28 January 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3137751
2 January 2008
Drydock Extension · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3123785
5 February 2007
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2866980
2 May 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2637916
6 January 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2557164
2 May 2005
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2348001
26 February 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2012982
4 February 2004
Examination of Repairs · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1970848
10 July 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1847511
27 June 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1832717
16 April 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1605661
4 February 2002
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1482547
17 July 2001
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1068062
31 January 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395622
12 September 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446980
16 August 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 821168
28 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 121467
13 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 65923
13 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 222444
13 July 2000
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1051381
7 July 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 820342
25 May 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1470557
22 July 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 44845
16 April 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469285
25 February 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 800431
30 September 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399132
27 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 787424
21 August 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1383650
11 December 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1110176
8 October 1996
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435818
25 June 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1396541
29 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 877373
22 November 1995
Inclining Experiment
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1425656
16 June 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1430056
12 August 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1416011
27 October 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 833014
29 June 1993
Plan Review "T" Boat · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 845698
27 June 1993
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 674589
7 June 1993
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 115493
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2026
Resolved
All electrical installations shall be to the satisfaction of the OCMI.
1. There are two surge traps beneath the operating station that are not secure.
2. Secure the battery box lid beneath the operating station.
3. Secure loose terminal boards in the engine compartment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 22 May 2026
Resolution: all items repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 May 2026
Resolved
All pyrotechnic distress signals shall be stored in a watertight container. The distress signal container is not watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 22 May 2026
Resolution: replaced with proper box.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 May 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must be approved by the Commandant. The "charged" or "normal" light at the operating station is extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 13 May 2026
Resolution: POC provided photographic and video evidence of proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2026
Resolved
A vessel owner, charterer, operator or agent shall immediateley notify the nearest Coast Guard offic whenever an occurence materially and adversely affecting the vessel's seaworthiness occurs. On May 9, 2026 at 2130 the vessel suffered a failure of the gasket in way of the sea strainer inspection lid causing flooding in the #3 port void. Report the same to MSU Chicago Investigations Division.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 May 2026
Resolved 12 May 2026
Resolution: Received notification from SIO MSU Chicago of report of potential marine casualty.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2026
Resolved
Auxiliary machinery shall be suitable for the purpose intended. The gasket for the AC cooling water sea suction sea strainer inspection port is damaged. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 12 May 2026
Resolution: Received photographic and video evidence of completion.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 21 May 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel.
Port main deck salon access area is leaking water into the engine room. Investigate cause of leak and provide repair proposal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 7 August 2024
Resolution: Witnessed satisfactory repair and hose testing of steel deck replacement.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2024
Resolved
(a) A pre-engineered fixed gas fire extinguishing system must:
(1) Be approved by the Commandant;
(2) Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector;
(3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and
(4) Be installed in accordance with the manufacturer's instructions.
The Fireboy cable pull is installed with parts not approved by the manufacturer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
Resolution: Attended vessel and witnessed proper installation of Fireboy system and conducted operational test of alarms and shutdowns.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022
Resolved
Starboard main engine muffler was missing double hose clamps. Provide double hose clamps on muffler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 2 May 2022
Resolution: New clamp installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2022
Resolved
Prove proper operation of audible alarm for high bilge level in the rudder room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 2 May 2022
Resolution: New alarm panel installed, all alarms tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2022
Resolved
Carry no more than 93 total persons until 5 adult type I PFD's are provided onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2022
Resolved 24 June 2022
Resolution: Proof of 5 PFD's provided by photo cleared 835
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 May 2021
Resolved
COD mounted is expired, Provide new/ valid COD to attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: COD was renewed in May 21
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2021
Resolved
Install proper fuel filters on PORT main diesel engine and install metal bowl on genset fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: Metal bowl added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Install proper ring connectors on battery under bridge console.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: Proper connection added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2021
Resolved
Double clamp all R/W connections on the STBD MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2021
Resolution: Clamps added to hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020
Resolved
Wires hanging into bilge in fwd storage area. Remove/mount wires out of bilge area to satisfaction of Marine Inspector.
"Old T"
46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 June 2020
Resolution: Wires mounted to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 June 2020
Resolved
Remove/replace oily diapers from underneath propulsion engines and generator prior to carrying passengers.
"Old T"
46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2020
Resolved
Plastic expansion tanks for starboard engines are currently mounted with lines hanging off of cables. Mount tank to vessel metal structures with hardware to satisfaction of Marine Inspector.
"Old T"
46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 24 July 2020
Resolution: Expansion tank has been mounted to the satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2019
Resolved
Only 1 smoke and 5 flares sidtress signals were valid. Rest were expired, must have 6 each. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Provided 3 smoke and 8 day/night flares
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 June 2019
Resolved
Electronic tablet was not charged and would not load light list or river current publication. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Provided 2 means of electronic copies of all nav pub's
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 June 2019
Resolved
Aft main deck emergency light not working. 46 CFR 183.432
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Replaced bulb tested sat
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 5 June 2019
Resolved
Missing DAPI annual MIS report. 46 CFR 16.500(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 18 July 2019
Resolution: Provide doc that showed they had submitted results
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2019
Resolved
Crew not familiar with installed bilge system. Conducted training on the spot. 46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Conducted training on the spot
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Invalid MMSI, Invalid Call Sign, no static draft information, and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 10 November 2021
Resolution: Rcvd prrof that AIS info has been added.
Engineering › Bilge Water Management System › Piping
Issued 15 March 2017
Resolved
Fore and aft compartment suction is too slow and loses suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2017
Resolved 20 April 2017
Resolution: Re- Labled upper deck
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2017
Resolved
Install proper cable supports every 23 inches in engine roomWires need to be properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 20 April 2017
Resolution: Installed new metal holders
Stability › Incline Test › General
Issued 15 March 2017
Resolved
Incorrect number of passengers for upper deck listed on placard.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 20 April 2017
Resolution: Re-Label upper deck
Stability › Incline Test › General
Issued 12 August 2016
Resolved
Passenger count has been reduced to 80 pass until new SST is conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 11 October 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 22 July 2016
Resolved
16 adult and 06 children life vests need retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 11 August 2016
Resolution: 16 adult and 06 child lifejackets have had the retro reflective tape renewed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 July 2016
Resolved
Must have B-II fire extinguisher in engine room serviced.
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 11 August 2016
Resolution: B-II fire estinguisher in the engine room had the annaual service completed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 July 2016
Resolved
COD needs to be posted
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 11 August 2016
Resolution: New COD has been posted on board vessel.
Construction/Loadline › Hull › Stiffener
Issued 5 February 2016
Resolved
Rebuild flat bars behind rudder posts for structural stiffness IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 February 2016
Resolved
Renew insert on stbd longitudinal at transom in hull plate IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Stiffener
Issued 5 February 2016
Resolved
Crop and renew wasted flat bars at transom in hull plate in lazarette IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Stability › Watertight Integrity › General
Issued 5 February 2016
Resolved
Renew AC condensation drain in thru hull connection outboard port side transom IAW 46 CFR 176.610.
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Bracket
Issued 5 February 2016
Resolved
Repair wasted tripping brackets port and stbd side of lazarette IAW 46 CFR 176.610.
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Stability › Watertight Integrity › General
Issued 5 February 2016
Resolved
Repair wasted areas of transom on stern/lazarette IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 5 February 2016
Resolved
Gauge areas of concern including stbd side of hull, fwd most compartment, and bar hold IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 26 February 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Engineering › Steering Gear System › Rudder
Issued 27 April 2009
Resolved
Install port and stbd. rudder stops.
Due 11 May 2009
Resolved 19 May 2009
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 February 2007
Resolved
Provide current Navigation Rules and Charts specific route IAW 46CFR184.420.
Condition: Unknown
Due 12 February 2007
Resolved 17 April 2007
Resolution: Vessel CAPT purchased new USCG NAV Rules and chart appropriate for route.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 5 February 2007
Resolved
Provide SAE J1942 nonmetalic hose for prime mover sea suctions and double clamp IAW 46CFR182.720.
Condition: Improper Installation
Due 12 February 2007
Resolved 15 February 2007
Resolution: Emailed photos of installed SAE J2006 Shieldsflex Ultra 255-1140 hoses and double clamps.
Engineering › Steering Gear System › Pin
Issued 5 February 2007
Resolved
Provide lock nut or cotter pin for each for the nuts on the steering system.
Due 12 February 2007
Resolved 15 February 2007
Resolution: Master of vessel emailed photos of installed lock nuts.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 February 2007
Resolved
Provide lock nut/washers for batteries.
Due 12 February 2007
Resolved 15 February 2007
Resolution: Master of vessel emailed photos of installed lock nut/washers on batteries.
Communications › Alarms/Indicators › Fire Alarm
Issued 5 February 2007
Resolved
Provide UL217 smoke detectors in liquor hold and fuel hold and reduce combustible material in voids and holds.
Due 12 February 2007
Resolved 17 April 2007
Resolution: Vessel rep purchased 02 UL217 smoke detectors.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 February 2007
Resolved
Provide proof of employees covered by consortium, supervisor received 1 hour EAP training, list of personnel in random testing pool, and list of 2006 pre-empolment testing to comply with Chemical Testing Program requirements.
Due 12 February 2007
Resolved 12 February 2007
Resolution: [name withheld] faxed in consortium records to satisfy all outstanding requirements.
Construction/Loadline › Structures › Superstructure
Issued 5 February 2007
Resolved
At next drydock make perminant repairs to wasted areas IWO superstructure/deck house to deck connection; maintain temporary repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 February 2008
Resolution: Repairs complete.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 5 February 2007
Resolved
Provide operable Ground Fault Indicator (GFI) in FWD head.
Due 12 February 2007
Resolved 17 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2007
Resolved
Make wire penitrations of the engine room FWD bulkhead water tight.
Condition: Improper/Lack of Maintenance
Due 12 February 2007
Resolved 15 February 2007
Resolution: Master of vessel emailed photos of engine room FWD bulkhead penitrations filled with foam installation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 May 2005
Resolved
Post COI & Stability letter IAW 46CFR176.107, 302, & 306. POC had all documents inside a folder and this is an enclosed cabin. They have plenty of room to post required documents.
Condition: Improper Installation
Due 7 May 2005
Resolved 10 May 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2005
Resolved
Replace line for float light and tag line. Lines are all wasted.
Condition: Improper/Lack of Maintenance
Due 7 May 2005
Resolved 10 May 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 May 2005
Resolved
Post donning placards through out vessel. No donning placards are posted nor do the explain how to put life jackets on.
Condition: Improper/Lack of Maintenance
Due 7 May 2005
Resolved 10 May 2005
Engineering › Bilge Water Management System › Pump
Issued 2 May 2005
Resolved
Prior to the carriage of passengers, prove proper operation of your installed bilge pump system. Could not get suction from installed bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 3 May 2005
Engineering › Bilge Water Management System › Pump
Issued 2 May 2005
Resolved
Prior to the carriage of passengers, provide a 5 GPM portable hand held bilge pump IAW 46CFR Table 182.25-10(a). POC could not find pump, but believes it's onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 3 May 2005
Lifesaving › Hand Flares
Issued 27 June 2003
Resolved
PROVIDE 3 ADDITIONAL HAND HELD FLARES PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Quantity
Due 11 July 2003
Resolved 10 July 2003
Resolution: SAT
Lifesaving › Lifejacket/PFD (Type IV)
Issued 27 June 2003
Resolved
REPLACE 24" LIFERING PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Lifering
Due 11 July 2003
Resolved 10 July 2003
Resolution: WITNESSED - WHITE RING.
Operations/Management › Drills/Instruction
Issued 4 February 2002
Resolved
CONDUCT MAN OVERBOARD, ABANDON SHIP, AND FIRE DRILLS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 16 April 2002
Resolution: CONDUCTED SATISFACTORY DRILLS.
Construction/Loadline
Issued 31 January 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, MAKE PERMANENT REPAIRS TO HULL PLATING IN WAY OF IMPROPER REPAIRS MADE DURING LAST DRYDOCKING.
Condition: Unknown
Due 26 July 2001
Resolved 4 February 2002
Resolution: PLATE REMOVED AND SATISFACTORILY REINSTALLED.
Fire Fighting
Issued 31 January 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL FIXED FIREFIGHTING SYSTEM IAW 46CFR181.400-500. SUBMIT PLANS PRIOR TO INSTALLATION.
Condition: Unknown
Due 26 July 2001
Resolved 4 February 2002
Resolution: CONDUCTED SATISFACTORY INSTALLATION CHECK.
Construction/Loadline
Issued 12 September 2000
Resolved
MAKE PERMANENT REPAIRS TO HULL IN WAY OF LOW UT READINGS.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Fire Fighting
Issued 12 September 2000
Resolved
INSTALL FIXED FIREFIGHTING SYSTEM IN ENGINE ROOM IAW 46CFR181.400-500. SUBMIT PLANS OR SYSTEM FOR APPROVAL PRIOR TO INSTALLATION.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Construction/Loadline
Issued 13 July 2000
Resolved
MAKE PERMANENT REPAIRS TO SUNSHIELD AND PORT FORWARD RAIL.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Construction/Loadline
Issued 25 May 2000
Resolved
INSTALL HIGH LEVEL BILGE ALARMS IN RUDDER, ENGINE AND SEWAGE COMPARTMENTS.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Unknown
Issued 25 May 2000
Resolved
INSTALL PLACARD INDICATING MAX PASSENGERS ALLOWED ON UPPER DECK IAW STABILITY LETTER.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Navigation
Issued 16 April 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS ENSURE MASTHEAD AND STERN LIGHTS ARE OPERATING CORRECTLY. REPLACE CRACKED STERNLIGHT HOUSING.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Documentation
Issued 16 April 1999
Resolved
PROVIDE DRUG TESTING CONSORTIUM INFO IAW 46 CFR 16.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Fire Fighting
Issued 16 April 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 16 April 1999
Resolved
PROVIDE NEW WATERLIGHT BATTERY.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Construction/Loadline
Issued 30 September 1998
Resolved
Prior to carriage of passengers for hire, provide guaging report reflectinghull thickness for plating beneath engine compartment. Guagings to be on 6" centers in vicinity of stuffing tubues, 12" centers elsewhere.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Electrical
Issued 30 September 1998
Resolved
Remove electrical heating tape from vessel.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Construction/Loadline
Issued 25 June 1996
Resolved
HAVE THE VESSEL HAULED OUT OF THE WATER AND READY FOR A COAST MARINE INSPECTOR TO CONDUCT A DRYDOCK EXAM, NO LATER THAN OCTOBER 7, 1996.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Electrical
Issued 27 October 1993
Resolved
The 18.5 KW Kohler generator does not meet the requirements of 46 CFR_x001C_ 183.10-5(f) and must be replaced a generator suitable for use in an inspected vessel not later than the compliance date.
Condition: Unknown
Due 27 October 1993
Resolved 27 October 1993
Accommodation/Occupational Safety
Issued 27 October 1993
Resolved
Provide a second means of escape from the upper deck per 46 CFR 177.15-1(a)not later than the compliance date. The second means of escape must not belocated in the same vicinity as the primary means of escape.
Condition: Unknown
Due 27 October 1993
Resolved 27 October 1993
Accommodation/Occupational Safety
Issued 29 June 1993
Resolved
Provide bottom step for the engine room stair to prevent injury not later than the compliance date.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Unknown
Issued 29 June 1993
Resolved
Provide evidence of compliance with DOT drug testing regulations per _x001C_ 46 CFR, Part 16, not later than the compliance date.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Accommodation/Occupational Safety
Issued 29 June 1993
Resolved
Provide a means to prevent children from slipping through the open area between the deck railing and the pilothouse not later than the compliance date.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Lifesaving
Issued 29 June 1993
Resolved
Conduct underway emergency drills with the assigned vessel crew not later than the compliance date.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Construction/Loadline
Issued 29 June 1993
Resolved
Vessel is restricted to the carriage of 49 passengers until resolution of the below deck 12 VDC electrical installation.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Construction/Loadline
Issued 29 June 1993
Resolved
Provide brace for the forward deck hatch cover not later than the compliance date.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993