Records from 2001 to 2012. Most recent: inspection, 24 July 2012.
Inspection history · 8
24 July 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4385678
9 February 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4241150
28 November 2010
Type not recorded
No type recorded · Activities Europe · Activity 3900303
29 March 2010
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3705068
16 January 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3395198
16 January 2009
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3395571
13 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 292968
13 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1071115
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 29 March 2010
Resolved
Cargo System Valving - manifold quick closing valves did on three occasions not close in less than the required 30 seconds; fastest closure time witnessed was 1 min 20 sec. The cite used for this deficiency was GCC Code 1983 5.3.4 b
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2010
Resolution: Received Lloyd''s report & verified onboard.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 29 March 2010
Resolved
Vessel could not demonstrate proper operation of the fixed gas detection system from the motor room. Tested system with span gas (8% butane) from inside cabinet, system alarmed properly at 20 % lel. Unable to successfully test from other space (motor room). The cite used for this deficiency was GCC Code 1983 13.6.6.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2010
Resolution: Received Lloyd''s report & verified corrected onboard.
Fire Fighting › Water Fog Applicators › Condition
Issued 29 March 2010
Resolved
Deck water spray aft of tank dome #2 including superstructure does not provide a uniform distribution of water. Half of the superstructure nozzles are either missing or clogged and several nozzles around tank dome #2 are missing or clogged. The cite used for this deficiency was GCC Code 1983 11.3.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2010
Resolution: Received Lloyd''s report & verified corrected onboard.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 29 March 2010
Resolved
Vessel reported that their Inert Gas System is inoperable prior to arrival. Current Cargo does not require use of IG. Spare part is on order but is delayed in delivery. Vessel must ensure certificate issuing authority is aware of the situation and have an operable inert gas system prior to carriage of cargos requireing IG. GCC 1983 9.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2010
Resolution: Received Lloyd''s report & verified corrected onboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 March 2010
Resolved
Fire extinguishing appliances shall be properly installed and kept in good order and available for immediate use at all times. Two(2) primary distribution valves for the vessel's fixed CO2 system were found to be wired closed, one leading to the engine room and the other to the motor room, preventing the delivery of CO2 to either space in a fire emergency.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2010
Resolution: correct on the spot
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 29 March 2010
Resolved
Inspector could not verify vessels individual MARV settings from the valves or or by matching valve serial numbersto recently issued certificates. MARVs are wire sealed and do not appear tampered with. GCC 1983 8.2.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2010
Resolution: Received Lloyd''s report & verified corrected onboard.