MAURY USCG vessel records
← All vessels

CAPT MARK SUMMERS

Built
1989
Last inspected
29 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 July 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC2283
341211
Flag
UNITED STATES
Maury page id
psix-341211

Documentation record

Registered dimensions (L × B × D)62.0 ft × 20.0 ft × 9.5 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC · PATTERSON, LA, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OPPORTUNITY Passenger (Inspected) · MISLE 1407706 · 15 April 2025 · activity 8113817

Inspection history · 21

29 July 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8197370
4 June 2025 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8151724
16 April 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8112503
15 April 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113817
4 June 2024 Deficiency Check · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7912269
25 January 2024 In-Service Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7855772
14 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7714725
9 November 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592030
25 May 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7464413
19 January 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7382293
12 August 2021 Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7283919
10 June 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6972150
10 February 2020 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6905947
23 November 2019 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6873416
3 June 2019 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6703383
4 June 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6433579
8 January 2018 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6333920
30 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297828
19 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180577
31 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5892308
26 January 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5803351

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 July 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of propulsion to Sector New York. Must complete repairs, provide casual analysis, and conduct sea trial prior to the carriage of passengers. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2025
Resolution: Attended vsl in person for sea trials and examined repairs
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2024 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operatior, person-in-charge, or a designated memeber of the crew. Vessel was not signing Extinguisher tags. 46 CFR 176.810(b)(1)(ii) - 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2024
Resolution: Operatior provided detailed report(attached) attesting to the rectification and service of the required extinguishers and pre-engineered fixed firefighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 November 2019 Resolved
Lazarette bilge suction missing basket/strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 20 December 2019
Resolution: Strainer was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 November 2019 Resolved
Bilge float switch electrical connections are not made within an enclosure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 20 December 2019
Resolution: Wires were in watertight enclosure
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 November 2019 Resolved
Life ring on bow has deteriorated grab lines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 20 December 2019
Resolution: Replaced with new life ring
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 November 2019 Resolved
Life ring float light has expired battery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 20 December 2019
Resolution: New battery installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019 Resolved
Bulkhead penetrations in halon space missing fire protection compound.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 20 December 2019
Resolution: Fire stops were installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019 Resolved
Prove proper operation of fixed fire extinguishing system shutdowns. Pressure switches do not shut down all generators. Vessel is restricted to operating #1 generator until shutdowns are repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 20 June 2019
Resolution: Observed satisfactory shutdown of the main engine and all generators upon testing of the vessel's fixed fire extinguishing system.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 June 2019 Resolved
Current COI requires vessel to have a life raft. Replace missing life raft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 20 June 2019
Resolution: Vessel not required to have life raft for Rivers route. Operator requested update of COI to reflect 00 IBA and opted to remove life raft.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019 Resolved
Controls must be installed in accessible location outside the space. Pressure switches for fixed fire extinguishing system are located in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 20 June 2019
Resolution: Relocated pressure switch outside the engine room.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 June 2017 Resolved
The shutdown device on the Halon system is onoperable. This device must shutdown ventilation and engines upon actuation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2017
Resolved 20 June 2017
Resolution: Viewed proper engine shutdown of halon system.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 31 May 2016 Resolved
kk01 - Install hydrostatic release for life raft.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 15 June 2016
Resolution: Vessel is on a rivers route with not rquirement to cary liferaft. Operator removed liferaft from vsl.
Construction/Loadline › Hull › Weld
Issued 31 May 2016 Resolved
kk02 - repair port quarter cleat. weld to deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 15 June 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.