Records from 1992 to 2026. Most recent: inspection, 7 January 2026.
Inspection history · 35
7 January 2026
COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8291388
20 October 2025
COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8255872
25 July 2024
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7966874
13 October 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7808110
21 December 2022
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7611757
24 October 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7581123
28 July 2021
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7264704
20 July 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7262219
27 January 2021
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7131852
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6513619
31 July 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6496386
26 September 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4992507
19 September 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4989081
11 June 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4886629
7 April 2011
Deficiency Check · Industry Initiated Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3981738
5 May 2010
Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3731547
22 November 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3367573
6 March 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2882604
22 November 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2539298
7 November 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2530241
4 November 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2528514
12 September 2005
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2490198
9 September 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2487969
12 August 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2460339
25 March 2005
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2334664
23 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2297871
28 October 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2230108
1 December 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1959316
31 January 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1738285
10 July 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1643902
15 April 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1604923
6 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 482403
27 March 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 74849
16 May 1994
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 649347
6 August 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 39154
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 November 2025
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. Bracket for portable fire extinguisher not attached to the bulkhead in the galley. Properly attach bracket to the bulkhead. 46 CFR 140.505(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2025
Resolution: Installed an approved bracket.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2025
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers. Certificates detailing service on all fire extinguishers need to be provided to inspectors for both portable and semiportable extinguishers.
46 CFR 142.240(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Proper documentation provided to detail the testing on all fire extinguishing systems on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Port and Stbd engines leak excessive amounts of oil. Repair to the satisfaction of attending Marine Inspector.
46 CFR 143.205(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Oil leaks on both Port and Stbd engines resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F) must be insulated. Insulation on Port Side Engine was torn and worn. Replace to the satisfaction of the Attending Marine Inspector.
46 CFR 143.220(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: Insulation replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2025
Resolved
5. Connections and terminations must be suitable for the installed conductors, and must retain the original electrical, mechanical, flame-retarding, and where necessary, fire-resisting properties of the conductor. Dead end wires found:
a. Starboard side generator
b. Behind ECDIS
c. Beneath operating station
d. Port and Stbd engine
Repair to the satisfaction of the attending Marine Inspector
46 CFR 143.575
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: Dead end wires were properly capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port and Stbd generator leaking under oil reservoir. Repair to the satisfaction of the attending Marine Inspector.
46 CFR 143.205(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Leaks were resolved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2025
Resolved
All fire hoses must be inspected for excessive wear, and subjected to a test pressure equivalent to the maximum service pressure. All fire hoses which are defective and incapable of repair must be destroyed. Stbd fire hose was leaking. Replaced during inspection.
46 CFR 142.240(a)(7)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 November 2025
Resolved
The name of the towing vessel must be marked or painted in clearly legible letters on each EPIRB, except on an EPIRB in an inflatable liferaft. The owner or managing operator must maintain valid proof of registration. EPIRB not registered. Name not on EPIRB. EPIRB has not been tested. Rectify to the satisfaction of the attending Marine Inspector.
46 CFR 141.380( c)(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Name and registration number written on EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 November 2025
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket for each person on board. 03 lifejackets were no longer serviceable. Replace 03 lifejackets.
46 CFR 141.340
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: 03 life jackets replaced
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 November 2025
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Lifejacket were stowed in a container without required labeling. Label container appropriately.
46 CFR 141.340(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: Container properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 November 2025
Resolved
A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS” Container was not appropriately labeled.
46 CFR 141.375( e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: Container was properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 4 November 2025
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation a Fathometer (except Western Rivers). Fathometer was inoperable. Rectify to the satisfaction of the attending Marine Inspector. 46 CFR 140.725(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: Fathometer properly connected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 November 2025
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation a Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. Search light light bulb was inoperable. Rectified during inspection.
46 CFR 140.725(b)
Action required: 10 - Deficiency Rectified
Resolved 4 November 2025
Resolution: Light bulb replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 November 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2026
Resolved 16 March 2026
Resolution: Mariner submitted application to renew - awaiting renewal due to current MMC office closures
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 November 2025
Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. 46 CFR 140.405( c)
Unless otherwise stated, each crewmember must receive the instruction required by this section annually. 46 CFR 140.420( c)
Captain and crew were unaware of where to find emergency procedures. Provide and post emergency procedures for crew and Captain awareness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Emergency procedures posted
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 November 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol strips were expired. Ensure vessel is equipped with valid alcohol strips for maximum persons onboard (6) at minimum. 46 CFR 4.06-15(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Sufficient alcohol strips replaced and onboard.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 4 November 2025
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass. The compass must be readable from each operating station. Compass was not illuminated and GPS has not been recently calibrated. Provide proof of calibration and ensure illumination.
46 CFR 140.725( c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Compass now illuminated, GPS installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2025
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Guards on both engines are forward of the rotating parts. Move guards to cover rotating parts.
46 CFR 144.820
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2026
Resolution: Guards now cover rotating parts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 November 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Air filters on Port side engine were excessively dirty. Replace air filters on Port side engine.
46 CFR 143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: Air filters replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 November 2025
Resolved
Each towing vessel must be fitted with a general alarm that: Is activated at each operating station and can notify persons onboard in the event of an emergency; General alarm could not be activated. Rectify to the satisfaction of the attending Marine Inspector.
46 CFR 143.235(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2026
Resolution: General alarm fixed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 October 2023
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Engine room starboard heat detector was inoperable during testing.
46 CFR 142.330(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2023
Resolved 17 October 2023
Resolution: Vsl provided technician report and unit visited to conduct operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2023
Resolved
The results of the inspections required by 33 CFR 164.76 must be documented in the TVR, or official logbook. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. The vessel did not have any recordkeeping for towing gear on board.
46 CFR 140.820
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2023
Resolved 17 October 2023
Resolution: VSL implemented VTR, conducted inspection of gear and logged the results.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2023
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants at a pressure of at least 50 psi and a flow rate of at least 80 gallons per minute. Installed fixed fire pump could not reach 50 psi.
46 CFR 142.325(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 1 November 2023
Resolution: Attending MI's witnessed the fire pump delivering water to its two highest hydrants and maintained a pressure of over 60 psi.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 October 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire. There are no dampers or ventilation covers to stop air flow to the engine room.
46 CFR 144.605
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: VSL Rep provided photos of damper they added that can be closed in the event of a fire.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 October 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port and starboard generator windings are coated excess oil and dirt, and require cleaning.
46 CFR 143.400(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 17 October 2023
Resolution: Vessel provided photos of windings.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 October 2023
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Life raft painter line on board was not secured to the weak link and would not release upon hydrostatic release activation.
46 CFR 199.190
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 October 2023
Resolved 13 October 2023
Resolution: Crew properly arranged painter line.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2023
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel. Port and starboard generator fuel filters are not properly secured.
46 CFR 143.205(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 17 October 2023
Resolution: Fuel filters were properly secured to bulkhead.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 October 2022
Resolved
AIS must be maintained in effective operating condition, which includes the accurate input and upkeep of all AIS data fields and system updates. The currently encoded antenna position dimensions and draft are inaccurate and must be encoded in meters, not feet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 12 December 2022
Resolution: The AIS broadcast data for the Doctor D has been updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2022
Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel’s lifesaving is in good working order. The starboard side lifebuoy had a wasted plug in the outer shell. In addition, the port and starboard lifebuoy’s retro reflective tape needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 29 November 2022
Resolution: 02 new lifebuoys were placed on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2022
Resolved
The frame or support of any semiportable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Permanently attach the frame for the semiportable fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 10 November 2022
Resolution: Frame of the semiportable fire extinguisher attached to the deck railing with U bolts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022
Resolved
Electrical conductors passing through watertight bulkheads must be installed so that the bulkhead remains watertight. Several cable penetrations above the pilothouse were not watertight and are required to be sealed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2022
Resolved 29 November 2022
Resolution: The cable penetrations were temporarily repaired to provide a watertight seal.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 October 2022
Resolved
Towing vessels must meet the communication requirements of 33 CFR 26 and 33 CFR 164.72 as applicable. The starboard forward VHF antenna bracket is corroded and is required to be remounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 29 November 2022
Resolution: The VHF antenna bracket was remounted.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 October 2022
Resolved
Each remote fuel shutoff valve control must be marked in clearly legible letters, at least 1 inch high, indicating the purpose of the valve and the way to operate it. Found no labeling of remote valve controls.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 10 November 2022
Resolution: The remote fuel shutoff valves have been labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2022
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. 01 lifejacket in the crew berthing had an expired lifejacket light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 10 November 2022
Resolution: Lifejacket light replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022
Resolved
Electrical systems and equipment must minimize fire and shock hazards. One (01) 120 VAC duplex outlet in the galley near the table was missing its receptacle cover plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 10 November 2022
Resolution: Receptacle cover plate replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2022
Resolved
Piping and machinery components that exceed 220 degrees Celsius, including fittings, flanges, valves, exhaust manifolds, and turbochargers must be insulated. Found the exhaust lagging loose for the port main engine, port/starboard generators, lock wire was missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 29 November 2022
Resolution: Exhaust lagging was secured
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The outer cable insulation running into the bottom of the capstan electrical box was not held in place by the cable clamps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 21 December 2022
Resolution: Cable clamps placed at both ends of cable runs into electrical boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 October 2022
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. The port and starboard generators are missing guards over the rotating pulley on the front of the engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 10 November 2022
Resolution: Guards placed over the rotating pulley
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2022
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitting with a floating electric water light approved under approval series 161.010 or 161.110. The installation of corrosion resistant clip for both the port and starboard water-lights did allow the water-lights to float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 29 November 2022
Resolution: The clip was removed from the light housing and placed around the body of the lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2022
Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel’s lifesaving and fire suppression and detection equipment is in good working order. The portable fire extinguisher near the starboard side engine room door had excessive corrosion around the neck to the cylinder and requires replacement.
Action required: 10 - Deficiency Rectified
Resolved 24 October 2022
Resolution: Portable fire extinguisher replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 October 2022
Resolved
A vessel of 20 meters or more in length shall be provided with a bell. Replace the bell clapper.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 10 November 2022
Resolution: Bell clapper replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2022
Resolved
Pressure vessel must be equipped with one or more spring-loaded relief valves. Found the both the port and starboard start air receivers relief valves would not reset after being hand relieved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 21 December 2022
Resolution: Relief valves replaced with spring loaded relief valves set at 175psi
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels. Center bilge alarm on engine room was non operational.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 July 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. - Water found dripping on the port side gen set.
- Inspectors found exposed wires above port and starboard MDE.
-Inspectors found exposed wires under operating station.
- Grounding cables on STBD side generator are disconnected from ground.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2021
Resolution: Holes patched to satisfaction of OCMI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 July 2021
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crew members. All safety- sensitive employees must be enrolled in an acceptable drug and alcohol testing program. All individuals serving in a licensed capacity on vessel need enrollment
into company DAPI. Master is required to be added to the drug and alcohol program.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2021
Resolved
A towing vessel that is certified for rivers, lakes, bays, and sounds, less than 3 nautical miles from shore must be equipped with an approved 160-B semi-portable fire-extinguishing system or a fixed fire-extinguishing to protect the engine room.
-Vessel was not equipped with a 160-B semi-portable fire extinguisher or a fixed fire extinguishing system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2021
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light.
-Port side water light attached to life buoy not operable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 3 August 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 July 2021
Resolved
The following list of items must be recorded in the TVR, official logbook: Personnel records, Safety orientation, Record of drills and instruction, Examinations and tests, Operative navigational safety equipment, Navigation assessment, Navigation safety training, Oil residue discharges and disposals, Record of inspection of towing gear, Fire-detection and fixed fire-extinguishing.
- No presence of records on board vessel for Personnel records, safety orientation, navigation safety training, examinations and tests, pre-departure tests and inspections.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 13 August 2021
Resolution: Logs updated.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 July 2021
Resolved
When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks.
-EPIRB hydrostatic release unit unit found expired.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 3 August 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 July 2021
Resolved
(a) All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
-Install gasket on galley port hole cover.
-Make watertight galley door.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 13 August 2021
Resolution: Gasket applied and sealing satisfactory to OCMI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 75% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 October 2021
Resolved 17 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2021
Resolved
Essential systems or equipment must be regularly tested and examined. If a component is found unsatisfactory, it must be repaired or replaced. The bilge manifold showed signs of severe wastage on piping which led to a steady water leak into the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2021
Resolved 17 February 2021
Resolution: wastage on bilge manifold removed and replaced. Before and after photos attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 January 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly. The forepeak hatch gasket was severely wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2021
Resolved 2 February 2021
Resolution: Gasket replaced and hatch sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2021
Resolved
All machinery and equipment that is not in proper working order must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. The PVC piping and pipe thread in the engine room overhead used for sewage is rusted and severely wasted. Piping penetrating the deck into the engine room from the washer was also found rusted and wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2021
Resolved 2 February 2021
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 27 January 2021
Resolved
No person shall conduct an oil or hazardous material transfer operation unless each drain and scupper is closed by mechanical means required by 155.310 for fuel oil containment. Both the port and starboard side fuel oil fill station enclosed coaming had openings at the bottom that would not allow for a plug or other device to contain fuel oil if discharged during transfer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2021
Resolved 2 February 2021
Resolution: Openings closed and plug installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2019
Resolved 23 January 2019
Resolution: Vessel operator acknowledged the AIS discrepancy and provided proof from the AIS website.