Inspection record

Last inspected 7 October 2025
…with no type recorded28
Operational controls None recorded without a removal date
Years with a record 26 calendar years (2000–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
1167 - Simplified, Net Ton 1167 - Simplified, Gross Ton
Maury page id
psix-851
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

DOCTOR D Towing Vessel · MISLE 341354 · 26 September 2014 · activity 4992507DOCTOR D Towing Vessel · MISLE 341354 · 19 September 2014 · activity 4989081ENTERPRISE Tank Barge · MISLE 810645 · 17 April 2007 · activity 2911476

Inspection history · 77

7 October 2025 Cargo Tank Internal · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8244048
9 July 2025 Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8185424
12 July 2024 MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7956585
26 July 2023 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7752882
12 July 2023 MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7741551
7 December 2022 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7605431
28 June 2022 Annual Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7489463
12 April 2021 COI Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7173747
25 January 2021 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7130065
25 November 2020 Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7102055
21 July 2020 Administrative Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7011930
16 August 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6788781
3 February 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6619255
5 December 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6592726
5 December 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6593061
29 November 2018 In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6589695
20 August 2018 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6548393
18 May 2018 COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6412053
12 July 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6206301
1 November 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033328
28 September 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6040352
12 July 2016 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5936996
23 July 2015 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5193478
7 May 2015 Drydock Exam · Cargo Tank Internal · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5119541
26 September 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4992507
19 September 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4989081
3 July 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4909423
4 June 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4879429
13 May 2014 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4857361
12 December 2013 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4768329
20 September 2013 Periodic Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4719535
1 July 2013 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4641022
20 August 2012 MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4416539
6 January 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4219550
19 December 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4210593
8 December 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4204076
5 December 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4201558
5 December 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4201985
3 November 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4181607
7 September 2011 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4139410
9 August 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4110124
26 July 2011 Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4094604
1 July 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4064526
18 October 2010 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3871973
2 October 2010 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3861611
18 June 2010 COI Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3769765
19 April 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3719811
6 April 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3710481
20 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3666876
18 September 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3597520
13 August 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3564926
21 July 2009 MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3592763
23 June 2008 Internal Structural Exam · MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3260426
7 June 2007 Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2953961
18 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2947392
17 April 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2911476
9 March 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2884775
13 June 2006 Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2734589
13 September 2005 MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2490203
13 September 2005 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2524927
9 August 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2467176
27 June 2005 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2382869
23 June 2005 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2400556
15 April 2005 MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2334689
23 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2297882
12 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2245380
3 September 2004 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2185245
20 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2010076
8 July 2003 Periodic Inspection · Internal Structural Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1839751
27 June 2002 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1642624
31 October 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 464266
5 October 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 637604
29 August 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 189204
12 August 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 442938
22 May 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1065954
5 March 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 498225
5 June 2000 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417080

Deficiency record · 69

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 July 2023 Resolved
No extensive repairs to the hull or machinery which affect the safety of a vessel shall be made without the knowledge of the Officer in Charge, Marine Inspection. In #1 port void between bay 6-7, crop and renew transverse frame at longitudinal #3. 46 CFR 31.10-25
Action required: 705 - Other - as specified
Resolved 22 October 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 July 2023 Resolved
No extensive repairs to the hull or machinery which affect the safety of a vessel shall be made without the knowledge of the Officer in Charge, Marine Inspection. Between #4 and #5 port void in bay 1, there are 3 holes in the upper bulkhead. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 31.10-25
Action required: 705 - Other - as specified
Resolved 22 October 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2023 Resolved
Each battery deck box must be weather tight. The cover for the prime mover battery box has a hole on the lid that allows water intruseion. 46 CFR111.15-10 (f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2023
Resolved 26 July 2023
Resolution: Verified cover for battery box was fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 Deg F, shall be suitably insulated where necessary to preclude injury to personnel. The generator on vessels port side is missing lagging on the exhaust pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2023
Resolved 26 July 2023
Resolution: Verified lagging was replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 July 2023 Resolved
After an inspection under 35.35-20, but before a transfer of cargo, fuel oil, or bunkers may commence as descrived in this section and 33 CFR 156.120 and 156.150, the person in charge of the transfer shall prepare, in duplicate, a declaration of inspection. The original must be kept aboard the vessel, and the duplicate provided to the terminal supervisor or that person's representative. The supervisor or the representative may, upon demand, inspect the vessel to determine whether its condition is as stated on the Declaration of Inspection. The declaration of Inspection for bunkering operations was not signed by the facility.
Action required: 10 - Deficiency Rectified
Due 12 July 2023
Resolved 12 July 2023
Resolution: DOI provided.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 July 2023 Resolved
A fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two fitted screens, both of corrosion-resistant wire, of at least 20 by 20 mesh, spaced not less than 1/2 inch or more than 1 1/2 inches apart. The 5 starboard cargo tank has a broken flame screen that needs to be replaced.
Action required: 10 - Deficiency Rectified
Resolved 12 July 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 28 June 2022 Resolved
Annual surveys for endorsements. Vessels subject to initial and periodic surveys shall have annual surveys, within 3 months either way of the certificate's anniversary date. The annual surveys shall be made by and prove satisfactory to the assigning and issuing authority prior to executing the required annual endorsements on load line certificates or exemption certificates. The scope shall be as defined in § 42.09-40 and such as to ensure that the applicable load line marks are found to be correct for the condition the vessel is then in. Annual Loadline Survey has not been conducted.
Action required: 705 - Other - as specified
Resolved 7 December 2022
Resolution: Load line survey has been complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2022 Resolved
All cable for electric power and lighting and associated equipment must be checked for proper insulation resistance to ground and between conductors. The insulation resistance must not be less than that in section 34.2.1 of IEEE 45-2002 (incorporated by reference; see 46 CFR 110.10-1). Electrical cable next to 5 port cargo tank insulation was chaffed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 July 2022
Resolution: Vessel rep sent evidence of new electrical cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 April 2021 Resolved
Each prime mover must shut down automatically upon loss of lubricating pressure to the generator bearings if the generator is directly coupled to the engine. Unable to test generator low lube oil shutdown.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2021 Resolved
-Worn down wire on deck. -Gen room lighting wires hanging with broken brackets. -Distribution panel had some brackets missing and wires expose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 4 (port), crop and renew side chord at side long #3.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Replace side chord at frame #5 (port).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Replace side chord at frame #6 (port).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Replace side chord at frame #7 (Port).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 2 (stbd), crop and renew transverse watertight bulkhead at bottom corner at bilge knuckle.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Replace side chord at frame #12 (port).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 23 September 2020
Resolution: Verified replacement of side chords at frames 12 and 13.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 26 (port), repair/replace damaged side chord and side longs 1 & 2.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 23 September 2020
Resolution: Side chords at frames 23-26 have been replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 25 (port), crop & renew or reweld side long #1 to side chord.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 23 September 2020
Resolution: Side chord completely renewed at frame 25.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 24 (port), crop & renew side long #1.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 23 September 2020
Resolution: Side long #1 renewed from frames 23-26.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frames 24 and 25 (port), reweld/repair sheer strake & side shell plating lap joints.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 23 September 2020
Resolution: Angle bar that connects side shell and overhead at gunnel replaced from frames 23-26.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 23 (port), repair broken weld at side long #1.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 23 September 2020
Resolution: Completely renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 26 (stbd), crop & renew tank chord at side long #1.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 14 October 2020
Resolution: Replaced side chord (c channel) and damged side chord.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Clean rusted areas below aft entrance between frames 31 & 32 (port) and repair broken sections of ladder.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 30 (port), crop & renew side chord in-way-of side long #1.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
At frame 28 (port), repair broken weld between side chord & side long #1.
Condition: Damaged By Earlier Event
Action required: 703 - Prior to bunkering operations
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Stern Rake: At frame 33, starboard side, crop & renew side longs 1 & 2 and their tripping brackets.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 14 October 2020
Resolution: Verified satisfactory replacements.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
Stern Rake: At bottom plating in-way-of the entrance ladder, clean rusted areas and take thickness measurements. Also conduct thickness measurements to the surrounding structural members.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 10 December 2020
Resolution: Deficiency was rectified during repairs conducted at VLS shipyard in Port Arthur, TX. ABS and USCG completed joint exam, all SAT. Plate summary is uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 July 2020 Resolved
General Item: Repair damaged void space hatches and coamings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 3 September 2020
Resolution: All void space hatches were renewed.
01 - Certificates & Documentation › 013 - Documents › STS Operation Plan and Records of STS Operations
Issued 29 November 2018 Resolved
Oil Tankers subject to this subpart, and each U.S. oil tanker, wherever located, subject to this subpart, must carry onboard an STS Operations Plan that prescribes how that vessel will conduct STS operations. For US oil tankers, the STS Operations plan must be approved by the Commandant or an Authorized Classification Society. The vessel does not have a STS operations plan, approved by Commandant or an Authorized Classification society. Prior to conducting STS operations, provide proof of an STS operations plan, approved by Commandant or an Authorized Classification Society.
Action required: 705 - Other - as specified
Resolved 12 December 2018
Resolution: owner supplied ABS approved STS manual.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 18 May 2018 Resolved
Cargo Relief valves shall be tested at least once each year to determine that they function satisfactory at the pressure at which they set to open. Port side cargo relief valve was unable to be tested, due to a low cargo level. Provide documentation of satisfactory test of relief valve or conduct test in the presence of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 30 May 2018
Resolution: Tested sat.
Engineering › Pressure Vessel › Marking and Stamping
Issued 18 May 2018 Resolved
All pressure vessels aboard ships, mobile off shore drilling units, and barges are subject to periodic inspection. Vessel has an air receiver with a volume greater than 5 cubic feet aboard, that is not identified on the barge's COI. Pressure vessel must be removed from the barge or inspected IAW 46 CFR Subchapter F and placed on the vessels COI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 22 May 2018
Resolution: Removed from vessel
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 18 May 2018 Resolved
No cargo tank hatches, ullage holes, or butterworth plates shall be opened or shall remain open without flame screens. Multiple ullage opening flames screens were found bent or damaged unable to fit properly in the ullage opening. Repair or renew all damaged ullage opening flame screens.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 18 May 2018
Resolution: Renewed flame screens
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 July 2016 Resolved
Properly secure bulkhead penetration on PIC office in-way-of the A/C installation. 46 CFR 32.57-10(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 28 September 2016
Resolution: Penetration was properly secured.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 July 2016 Resolved
Properly blank-off (secure) missing breaker switches in PIC office panelboard. 46 CFR 111.01-1(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 15 July 2016
Resolution: Received picture attesting to the proper installation of blank in all panelboard openings.
Engineering › Fuel Oil Service System › Hose
Issued 12 July 2016 Resolved
Replace generator and cargo pump prime mover’s flexible hose with approved type. 46 CFR 56.60-25.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 28 September 2016
Resolution: Fuel hoses replaced with approved type (SAE J1942).
Documentation › Logs/Records › Oil Record Book
Issued 12 July 2016 Resolved
Barge shall maintain an Oil Record Book (ORB), Part II, as required by the applicable regulations. 33 CFR 151.25
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 28 September 2016
Resolution: ORB delivered to vessel operator and appropriate entries being made.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 3 July 2014 Resolved
Hydro test cargo piping.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 28 July 2014
Resolution: Verified proper test and records were available for cargo piping hydro test.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 3 July 2014 Resolved
Repair cargo pump emergency shutdown.
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 29 July 2014
Resolution: Witnessed proper operation of engine''s emergency shutdown.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 July 2014 Resolved
Blank opening in breaker panel.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 28 July 2014
Resolution: Openings in breaker panel were blanked off.
Electrical › Electric Generation Source (service) › Generator
Issued 3 July 2014 Resolved
Prove generator meets proper temperature rating.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 29 October 2014
Resolution: Witnessed test proving actual ambient temperature was not in excess of actual rated temperature.
Engineering › Fuel Oil Service System › Hose
Issued 3 July 2014 Resolved
Prove flexible hose meets SAE J-1942.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 29 October 2014
Resolution: Witnessed new SAE J-1942 listed hose installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2014 Resolved
Prove wiring installed with new air compressor meets cable requirements.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 29 October 2014
Resolution: Wiring was removed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 July 2014 Resolved
Repair stern light.
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 28 July 2014
Resolution: Verified stern light was operational.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 3 July 2014 Resolved
Post oil pollution placard.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 28 July 2014
Resolution: Oil pollution placard properly posted on board the barge.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 3 July 2014 Resolved
Renew cargo hoses ID'd by MI.
Action required: 705 - Other - as specified
Due 2 August 2014
Resolved 28 July 2014
Resolution: New cargo hoses were brought on board to replace worn ones.
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 July 2013 Resolved
Provide repair proposal for damaged chords located at port side void space #1 for frames 1,2, and 3.
Action required: 705 - Other - as specified
Due 12 August 2013
Resolved 10 December 2013
Resolution: Witnessed repair of damaged chord. Added special note to address further during next drydock.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 26 July 2011 Resolved
Hydraulic line outer jacket from the crane to the pump is wasted. replace with new.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 8 September 2011
Resolution: Hydraulic line was replaced pump operated satisfactory.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 26 July 2011 Resolved
Hydraulic line supply valve handles are broken. repair or replace
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 7 September 2011
Resolution: Valve handles were replaced.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 26 July 2011 Resolved
Port Prime mover battery gauge is reading past its normal range of operation.
Condition: Damaged By Earlier Event
Due 26 August 2011
Resolved 7 September 2011
Resolution: Gauge was fixed and is reading at normal operating range.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 July 2011 Resolved
STBD running light is cracked and allowing water to intrude. repair or replace.
Condition: Damaged By Earlier Event
Due 26 August 2011
Resolved 7 September 2011
Resolution: STBD running light was repaired.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 26 July 2011 Resolved
STBD prime mover fuel supply valve handles are broken, repair or replace.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 7 September 2011
Resolution: STBD fuel supply valve handles were replaced.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2011 Resolved
STBD battery cables are corroded, replace with new.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 7 September 2011
Resolution: STBD battery cables were replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Bolts
Issued 26 July 2011 Resolved
#6 supply valves flange is missing one bolt and nut, replace with kind.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 7 September 2011
Resolution: Bolt was replaced on #6 supply valve flange.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 June 2006 Resolved
Show the company's vessel response plan annual approval leter to attending USCG inspector.
Due 13 July 2006
Resolved 16 August 2006
Engineering › Fuel Oil Service System › Filter
Issued 13 June 2006 Resolved
Replace racor filter plastic screw with a metal screw.
Due 13 July 2006
Resolved 16 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 13 June 2006 Resolved
Replace the deck lighting bulb that was blown. (After Most light)
Due 13 July 2006
Resolved 16 August 2006
Construction/Loadline › Hull › Double Hull
Issued 23 June 2005 Resolved
Repair leak in #5 port double bottom 3rd bay inwards from forward access cover iwo forward transverse bulkhead. between 4&5 frame from center line
Due 7 July 2005
Resolved 10 August 2005
Construction/Loadline › Hull › Bracket
Issued 23 June 2005 Resolved
Replace bracket #2 & #3 from top to bottom in starboard corner of afterpeak and fix associated stiffener.
Due 7 July 2005
Resolved 10 August 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 July 2003 Resolved
Replace flame screens on all cargo tanks vents with 30 x 30 mesh per square inch of non-corrosive material. LEGACY COMPONENT DESC: Flame Screens
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2003
Resolved 5 August 2003
Engineering › Fuel Oil Service System
Issued 8 July 2003 Resolved
Replace fuel hoses on both main diesel engine and generator. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 5 August 2003
Electrical › Electric Generation Source (service)
Issued 8 July 2003 Resolved
Demonstrate proper operation of the generator emergency shutdown. LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2003
Resolved 5 August 2003
Construction/Loadline › Markings
Issued 8 July 2003 Resolved
Paint draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 5 August 2003
Construction/Loadline › Markings
Issued 27 June 2002 Resolved
Repaint the draft markings on the starboard aft side. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 July 2002
Resolved 5 September 2002
Resolution: Draft marking repainted.
Operations/Management › Equipment Service/Testing
Issued 27 June 2002 Resolved
Clean all oily residue and standing liquid from the #1 starboard void in the area aft of the fwd bulkhead and make space available for inspection. (Oil appears to be used motro oil that was dumped in void.) Tank next to void containes Diesel. Material does not appear to be any product carried. LEGACY COMPONENT DESC: Engine oil disposal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2002
Resolved 5 September 2002
Resolution: Void cleaned and will monitor.
Documentation › Safety/Response Plans/Programs
Issued 27 June 2002 Resolved
Update the cleanup contractor and contact numbers for MSO San Juan in Vessel Response Plan and vessels transfer and notification procedures. LEGACY COMPONENT DESC: Vessel Response Plan
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2002
Resolved 5 September 2002
Resolution: VRP updated.
Documentation
Issued 5 June 2000 Resolved
PROVIDE VALID COFR PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Documentation
Issued 5 June 2000 Resolved
PROVIDE OIL TRANSFER PROCEDURES PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Documentation
Issued 5 June 2000 Resolved
PROVIDE APPROVED VRP PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Documentation
Issued 5 June 2000 Resolved
PROVIDE APPROVED SOPEP PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.