MAURY USCG vessel records Sign in
← All vessels

ZENITH

ZENITH is a 1990 passenger vessel (inspected). The Coast Guard has recorded 119 inspections since 1992, most recently in April 2024, along with 51 deficiencies and 2 operational controls.

Records from 1992 to 2024. Most recent: inspection, 4 April 2024.

Built
1990
Last inspected
4 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8918136 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
372158
Flag
MALTA
—
Maury page id
psix-372158

Inspections, by type

…with no type recorded36
Years with a record 17 calendar years (1992–2024)
The 119 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it47255 - Convention (Subpart B), Gross Ton
47255 - Simplified, Gross Ton
24560 - Convention (Subpart B), Net Ton
26505 - Displacement, Ton
6313 - Dead Weight, Ton
24560 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUN STATE 1102 Tank Barge · MISLE 468251 · 27 February 2005 · activity 2300648MILLENNIUM Tank Barge · MISLE 851 · 31 October 2001 · activity 464266HACKENSACK Unclassified · MISLE 44931 · 7 October 2000 · activity 473505VICTORIA 1227 Tank Barge · MISLE 44487 · 9 March 1998 · activity 436948

Inspection history · 119

4 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7889928
2 March 2007 COC-CVE Annual
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2880849
19 January 2007 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 2859243
9 September 2006 ISPS III Exam · COC-CVE Quarterly · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2773563
9 March 2006 COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2599131
31 January 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2577095
27 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2574604
8 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563397
28 November 2005 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2541943
15 October 2005 COC-CVE Quarterly · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2514955
23 August 2005 MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2471954
25 May 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2368007
23 April 2005 MARPOL Annex V Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2341074
27 February 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2300648
20 January 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2277720
16 January 2005 MARPOL Annex I Examination · Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2275848
16 January 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2277829
6 December 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2254039
3 November 2004 Administrative Inspection
Administrative · Maritime Safety & Security Team New York (91106) · Activity 2233945
1 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2232151
23 October 2004 COC-CVE Quarterly
Type not classified · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2226636
24 April 2004 Control Verification · MTSA/ISPS Verification · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2051625
24 April 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2051768
24 April 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2052145
9 November 2003 Quarterly Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1943315
11 October 2003 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1961150
26 April 2003 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1780773
26 April 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1781876
11 October 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1688276
28 September 2002 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1681351
27 September 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1687107
3 July 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1640573
22 June 2002 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1635362
14 April 2002 Deficiency Check · Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1605688
7 April 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1601950
17 March 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1495188
10 March 2002 Ballast Water Examination · MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination · Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492644
6 March 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1609675
24 February 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1488732
13 February 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1493102
10 February 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1485315
4 February 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1483599
3 February 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1483973
27 January 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1481657
18 January 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1479790
13 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1478484
6 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1476964
4 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1475542
23 November 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 103692
31 October 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 464266
1 September 2001 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071640
28 June 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1067381
9 June 2001 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1065577
12 March 2001 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1379331
7 October 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 473505
2 September 2000 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1437784
3 June 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278469
3 April 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1047576
5 March 2000 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404923
28 November 1999 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 809887
28 August 1999 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 781521
19 June 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 429755
19 June 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190218
18 June 1999 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1190385
29 May 1999 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430697
17 April 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1416866
25 March 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 778842
2 March 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 486566
1 March 1999 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388749
18 February 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1128282
5 February 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1128937
16 November 1998 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1426152
10 November 1998 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 804955
22 August 1998 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 797021
16 May 1998 MARPOL Annex I Examination · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 798405
9 March 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 436948
16 February 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412564
16 February 1998 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1114803
16 February 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439976
24 November 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410161
24 November 1997 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1121577
24 November 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1400679
23 August 1997 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120865
16 August 1997 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1119713
24 May 1997 Quarterly Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 775269
22 February 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 400307
22 February 1997 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1398624
23 November 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 397750
23 November 1996 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354063
7 September 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1363776
24 August 1996 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1089641
25 May 1996 Quarterly Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083131
24 February 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386795
24 February 1996 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1374506
9 December 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877277
20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 883720
26 August 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1182961
27 May 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187805
25 February 1995 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851039
10 December 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 833816
27 August 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 869049
13 June 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1325888
28 May 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 860498
26 February 1994 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 853257
26 February 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165106
13 November 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1147556
14 August 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 845738
26 May 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1142384
24 April 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 670322
9 March 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 357826
27 February 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 356647
27 February 1993 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1354262
19 December 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1132349
16 October 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 132208
26 September 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1254510
20 June 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952649
30 May 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1256556
25 March 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262791
15 March 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 960159

Deficiency record · 51

Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 2 March 2007 Resolved
Missing insulation in the overhead spaces throughout the vessel. Vessel will be going to dry dock in April 07. Structural fire protection must match the actual structure of the vessel. This is to be completed when the vessel is in drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 4 April 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami's Open Deficiencies List.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 September 2006 Resolved
Sliding fire screen doors #7-514, 6-511, 518, 5-538, and 4-509, 520, 534, 537, 538 are not operating properly (i.e. not closing, or safety closure device inoperative). All sliding fire screen doors must be fixed prior to departure from port, and additionally all sliding FSD doors on vessel must be tested prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2006
Resolution: Received class report from L/R that all items have been corrected.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 March 2006 Resolved
General - ensure that improperly placed combustibles, boxes, tires, garbage are removed from all electrical and storage lockers. This is a general house cleaning item.
Action required: 15 - Rectify deficiencies by next port
Due 1 April 2006
Resolved 4 April 2024
Resolution: 15 March 2006, received e-mail from Zenith Safety Offier (Lefteris Koumasidis) fotos provided; general outstanding housecleaning items have been completed. Improperly placed combustibles, boxes, tires, garbage has been removed. JG
Fire Fighting › Fire Hydrants › Location/Position
Issued 15 October 2005 Resolved
Fire station F.ST3-901 located in the hotel storeroom deck 4 forward blocked by boxes.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 15 October 2005
Resolution: Area has been cleared while onboard.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 15 October 2005 Resolved
Supplies in storeroom forward on deck 4 and 5 are up to the overhead blocking several heads. Clear boxes from 1 foot of the overhead prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2005
Resolved 15 October 2005
Resolution: Class provided a report, #MMI540105, which shows area cleared.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 15 October 2005 Resolved
Hotel staff storing items behind the linings of the storerooms on forward deck 4 and 5. Remove all the items stored behind the linings or have Class approve these spaces as storerooms that meet SOLAS II-2, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2005
Resolved 15 October 2005
Resolution: Class provided a report, #MMI540105, which shows area cleared and vessel to be submitting a proposal for turning this into a storeroom.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 15 October 2005 Resolved
Crew has installed a sprinkler system extension behind the linings of storeroom deck 5 forward, Class to approve this installation.
Action required: 705 - Other - as specified
Due 15 November 2005
Resolved 15 October 2005
Resolution: Class provided a report, #MMI540105, which shows that this will be include in a proposal for a new storeroom.
Lifesaving › Lifeboat › Markings
Issued 23 April 2005 Resolved
Fit retro-reflective tape on the lifeboats in accordance with IMO res A658(16), retro tape missing.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 25 May 2005
Engineering › Fuel Oil Service System › Valve
Issued 23 April 2005 Resolved
Fuel valves for incinerator leaking, valves repaired while onboard.
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 23 April 2005
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 23 April 2005 Resolved
Seating found in stairway outside beauty shops not secured to deck, also found display signs blocking landings. All seats and signs removed while onboard
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 23 April 2005
Construction/Loadline › Hull › Double Hull
Issued 16 January 2005 Resolved
BW DB TK # 7 FOUND FULL OF HFO, THERE ARE TWO HFO TANKS WITH COMMON BULKHEAD, BELIEVE LEAK TO BE IN DEEP TANK (HFO) 7. VESSEL TO CLEAN BALLAST TANK # 7 HFO LOWER & DEEP TANK, GAS FREE & FOR INSPECTION BY LlOYD'S , PROVIDE CLASS REPORT TO COAST GUARD.
Action required: 705 - Other - as specified
Due 20 January 2005
Resolved 19 January 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 23 October 2004 Resolved
The main laundry exhaust duct from deck 12 to deck 1 was found heavily soiled with accumulation of lint. This is to be professionally cleaned by a commercial contractor prior to Oct. 30, 2004 and prior to vessel shifting to winter port in Florida.
Action required: 705 - Other - as specified
Due 30 October 2004
Resolved 1 November 2004
Resolution: Verified as corrected by commercial contractor this date by Marine Inspector.
Operations/Management
Issued 11 October 2003 Resolved
Vessel was found knowingly receiving stores and provisions without previous screening as required. The vessel had received aprox.70 pallets none of which had been screened. LEGACY COMPONENT DESC: Security
Due 11 October 2003
Resolved 11 October 2003
Resolution: Required the Ship Security Officer to remove provisions/stores from the vessel for required screening.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 26 April 2003 Resolved
During the lowering of the lifeboats, lifeboats #10 and #8 bilge pumps were turned on while in the water and a sheen of oil was discharged. After further investigation it was found that several of the lifeboats had dirty bilges and crew was required to clean prior to the inspectors departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2003
Resolved 26 April 2003
Resolution: Bilges cleaned.
Electrical › Electric Generation Source (emergency)
Issued 26 April 2003 Resolved
Emergency fuel cut off of emergency generator not working properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2003
Resolved 26 April 2003
Resolution: Shut down was repaired and in operation prior to departure.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 28 September 2002 Resolved
Crew is in process of installing a High Fog System in the engineering space. Officers were not able to provide any proof that Class (Lloyd's Register) has any knowledge of this installation. Vessel to have Class approver the ongoing installation.
Action required: 705 - Other - as specified
Due 10 October 2002
Resolved 11 October 2002
Resolution: Class report received. Proposal for installing the high fog has been approved; system will be inspected after completion. See class report MMI0240141.
Fire Fighting › Structural - A Class Divisions
Issued 28 September 2002 Resolved
The Air Conditioning (A/C) space, off the starboard steering space, is being used as a storeroom. Crew to remove all stores, or have Class approve this and reclassify the space. LEGACY COMPONENT DESC: Bulkheads - Control Stations
Action required: 705 - Other - as specified
Due 10 October 2002
Resolved 11 October 2002
Resolution: Space has been check by Class and excessive equipment removed or properly stowed. See class report MMI0240141.
Lifesaving › Lifeboat
Issued 28 September 2002 Resolved
On all lifeboat tenders, where the struts attach through the hull, the fiberglass and gel coat appeared to be cracked. Class to examine these areas and make determination as to the water tightness of these boats. LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 10 October 2002
Resolved 11 October 2002
Resolution: Gel coat is just surfaced cracked over the strut support. See class report MMI0240141.
Lifesaving › Lifeboat
Issued 28 September 2002 Resolved
The #7 boat's bow was worn down through the gel-coat, past a few layers of fiberglass. Class to examine this area of the boat. LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 10 October 2002
Resolved 11 October 2002
Resolution: Bow examined by Class only surfaced layers cracked. See class report MMI0240141.
Pollution Prevention/Response › Prevention Equipment
Issued 22 June 2002 Resolved
Unavailable for inspection. Make availiable at next port visit to New York City on 29 June 2002. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 29 June 2002
Resolved 29 June 2002
Resolution: CONDUCTED A DEPICIENCY FOLLOW-UP CLEARED THIS OUSTANDING DEF.
Operations/Management › Drills/Instruction
Issued 22 June 2002 Resolved
Unavailable for exam, ship not aware that Quarterly was scheduled. Passenger ops in progress. Drills (BOTH Fire and Boat) rescheduled for next return to US port on 29 June 2002. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Due 29 June 2002
Resolved 29 June 2002
Resolution: CONDUCTED A DEF FOLLOW-UP AND CLEARED DEF ISSUED ON 22JUN02. NO DEFICIENCIES REMAIN OUTSTANDING.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 March 2002 Resolved
Clear space at deck #3 port side IWO stair way (Rivera deck) LEGACY COMPONENT DESC: Escape Route
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2002
Resolution: Verified cleared space.
Construction/Loadline › Structures
Issued 10 March 2002 Resolved
Provide class report addressing sat repairs for man hole access IWO stbd deck 1 foward of wtd 1-5 LEGACY COMPONENT DESC: Manhole
Condition: Unknown
Due 14 April 2002
Resolved 11 March 2002
Resolution: Cleared.
Electrical › Electric Supply System (service)
Issued 10 March 2002 Resolved
Provide class report addressing sat repairs for cables iwo nav room. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Due 14 April 2002
Resolved 10 March 2002
Resolution: Cable end were taped and secured. Cable is a spare wire.
Operations/Management › FireFighting
Issued 10 March 2002 Resolved
Provide an updated fire plan to satifaction of class. FD3-716 crew galley door not listed. LEGACY COMPONENT DESC: Fire Plan
Condition: Unknown
Due 14 April 2002
Resolved 14 April 2002
Resolution: Fire door incorrectly labeled. Correct label placed on fire door in accordance with fire control plan.
Engineering › Bilge Water Management System
Issued 10 March 2002 Resolved
Make permanent repairs to oily water separator equipment over board line. Soft patch located near aft blkhd space 9 eng. rm. complete at drydock to satisfaction of class. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 14 April 2002
Resolved 14 April 2002
Resolution: Pipe portion renewed and properly installed. Class approved.
Engineering › Fuel Oil Service System
Issued 10 March 2002 Resolved
Make permanent repairs to #2 fuel purifier steam tracing line where soft patched to satisfaction of class at drydock. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 14 April 2002
Resolved 14 April 2002
Resolution: Copper pipe replaced. Class approved.
Construction/Loadline › Hull
Issued 10 March 2002 Resolved
Provide class approval for #9 double bottom fixed ballast modifications. LEGACY COMPONENT DESC: Double Hull
Condition: Unknown
Due 14 April 2002
Resolved 14 April 2002
Resolution: Permanent ballast installed in existing HFO DB Tanks 9 P&S. Class approved.
Lifesaving › Lifeboat
Issued 10 March 2002 Resolved
Provide class report addressing damage to starboard life boats #7 and #9 iwo port quarter fendering system and stud attachments. LEGACY COMPONENT DESC: Fender
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 14 April 2002
Resolution: Damage to lifeboats corrected. Class approved.
Fire Fighting › Firemans Outfit
Issued 10 March 2002 Resolved
Provide class report addressing fire fighting life line meets SOLAS 74. Reg 17.2. LEGACY COMPONENT DESC: Lifeline
Condition: Improper Installation
Due 14 April 2002
Resolved 14 April 2002
Resolution: Vessel replaced fire fighting life lines. Class approved.
Electrical › Electric Supply System (service)
Issued 10 March 2002 Resolved
Provide class report addressing permanent installation of source power for the cellular syatem iwo nav room.
Condition: Improper Installation
Due 14 April 2002
Resolved 14 April 2002
Resolution: Power supply box moved to bulkhead. Class approved.
Lifesaving
Issued 12 March 2001 Resolved
Have Class address expired lifejacket lights on passenger lifejackets in passenger berthings.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 5 March 2000 Resolved
Remove the ATM from the stair tower, starboard side between the Casino and Show Lounge on Deck 8. IAW SOLAS 74 amended II-2, Reg 41-2.4.10._x001C_
Condition: Unknown
Due 5 March 2000
Resolved 5 March 2000
Fire Fighting
Issued 19 June 1999 Resolved
Deck #8 sales shop glass fronts between frames 56-71 port and stbd side arenot fitted with B-15 glass.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 17 April 1999 Resolved
Sales shops on deck #8 have direct access into the stairway enclosure. Make spaces not direct accessible as per MSC letter dated 21 May 1998 item #3.
Condition: Unknown
Due 17 April 1999
Resolved 17 April 1999
Documentation
Issued 1 March 1999 Resolved
ADDRESS RFSA ITEMS ISSUED BY COAST GUARD MARINE SAFETY CENTER LETTER DATED 21 MAY, 1998, NLT 01 APR 99.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999 Resolved
LOWER STBD SIDE LIFEBOATS IN THE PRESENCE OF CLASS SURVEYOR. ALL BOATS ARE TO BE LOWERED TO THE WATER AND DISCONNECTED AND RECONNECTED. TO BE COMPLETED NLT 09 MAR 99.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999 Resolved
REPAIR LIFEBOAT #12 RELEASING HOOK MECHANISMS TO RELEASE PROPERLY. PROVIDE DOCUMENTATION FROM CLASS SURVEYOR WITNESSING SUCCESSFUL TEST OF LIFEBOAT RELEASE. ITEM MUST BE CORRECTED PRIOR TO VESSELS DEPARTURE.
Condition: Unknown
Due 1 March 1999
Resolved 11 March 1999
Lifesaving
Issued 5 February 1999 Resolved
PRIOR TO MAY 15, 1999 PROPERLY REPLACE PORT SIDE LIFEBOAT #8 TO THE SATISFACTION OF CLASS SOCIETY (CONDUCT AN OPERATIONAL TEST OF SUCH). PROVIDE REPORT FROM CLASS ATTESTING CONDITION AND PROPER OPERATION OF SUCH LIFEBOAT.
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Lifesaving
Issued 16 November 1998 Resolved
Prior to next QCVE, properly replace/repair port side lifeboat #8 to the satisfaction of Class Society (conduct an operational test of such). Provide report from class attesting condition and proper operation of such lifeboat.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Unknown
Issued 24 November 1997 Resolved
PROVIDE FROM CLASS OF INTERLOCK SYSTEM OF #4 AND #3 STEERING MOTORS ON STARBOARD SIDE.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Unknown
Issued 24 November 1997 Resolved
CONDUCT ABANDONMENT BOAT DRILLS USING STARBOARD LIFEBOAT AND VIDEO SAME._x001C_ CORRECT NO LATER THAN 15DEC97.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Electrical
Issued 23 November 1996 Resolved
CONDUCT EMERGENCY GENERATOR TEST UNDER LOAD IN THE AUTOMATIC MODE AT NEXT ANNUAL EXAMINATION
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 23 November 1996 Resolved
TEST EMERGENCY GENERATOR IN AUTOMATIC MODE AND PLACE A LOAD ON THE GENERATOR AT ANNUAL CONTROL VERIFICATION EXAMINATION. SOLAS 74 AMENDED, II-1 42.7.
Condition: Unknown
Due 23 November 1996
Resolved 23 November 1996
Fire Fighting
Issued 10 December 1994 Resolved
PROVIDE ADDITIONAL WATER FOG APPLICATOR WHERE MISSING FOR EACH MAIN VERTICAL ZONE. NINE ONBOARD BUT PLAN INDICATES TEN MVZ.
Condition: Unknown
Due 10 December 1994
Resolved 10 December 1994
Fire Fighting
Issued 10 December 1994 Resolved
PROVIDE ONE PORTABLE FOAM APPLICATOR FOR EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 10 December 1994
Resolved 10 December 1994
Fire Fighting
Issued 10 December 1994 Resolved
PROVIDE TWO WATER FOG APPLICATORS FOR EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 10 December 1994
Resolved 10 December 1994
Fire Fighting
Issued 28 May 1994 Resolved
REMOVE PAINT CANS FROM THE STABILIZER/PUMP ROOM.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Lifesaving
Issued 28 May 1994 Resolved
DEMONSTRATE OPERATION OF THE DAVITS AND RELEASING GEAR FOR THE STARBOARD LIFEBOATS.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Navigation
Issued 27 February 1993 Resolved
Vessel operator or p.i.c. failed to ensure that the maneuvering factsheet had the following: 1. Table of shaft revolution or control setting for representative speeds. 2. Table at which speed bow thruster is effective.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Navigation
Issued 27 February 1993 Resolved
Vessel operator or p.i.c. failed to have onboard a current or complete copyof the INLAND NAVIGATION RULES.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993

Ownership record