Records from 1993 to 2007. Most recent: operational control imposed, 23 November 2007.
Inspection history · 21
23 November 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3100082
23 November 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3103193
21 November 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3104388
28 March 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2033203
31 January 2004
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1998128
19 August 2003
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1880857
5 August 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1861491
28 January 2002
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1480229
28 January 2002
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1485700
23 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 286399
5 October 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 433326
2 March 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 425940
8 September 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 420095
12 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412652
6 December 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 410702
18 November 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 397482
5 March 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 401205
6 February 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 387676
17 January 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 374097
15 December 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 362976
27 August 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 360422
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 23 November 2007
Resolved
The ship's gyrocompass repeaters are not in sync, specifically the steering gear room, port bridge wing, and helm repeaters which are reading approximately 180 degrees differently from the correct digital readout on the bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2007
Resolution: The ship''s gyrocompass repeaters were fixed by a technician and repairs verified by CG inspectors.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 31 January 2004
Resolved
Master and 4/E do not hold proper flag state endorsements. Provide proof of flag state endorsement to US Coast Guard prior to 1000 01FEB04.
Action required: 705 - Other - as specified
Due 1 February 2004
Resolved 31 January 2004
Resolution: NEWMS received a faxed copy of requested flag state endorsements.
Electrical › Lighting (service)
Issued 5 August 2003
Resolved
Renew intrinsicaly safe lichts in the battery/pyro room. To the sat of class. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2003
Deck/Cargo › Mooring/Anchoring
Issued 5 August 2003
Resolved
Make repairs to port anchor link studs where fractured. (studs 2&3 as counted from swivel) LEGACY COMPONENT DESC: Anchor Chain (general)
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 19 August 2003
Resolution: RECEIVED CLASS SURVEY VIA FAX FROM VESSELS AGENT (T.P HOST) STATING "PORT CHAIN CABLE LEADER NOW REPAIRED"
LR SURVEYOR: P.J. BEARD
Fire Fighting › Ventilation Systems
Issued 5 August 2003
Resolved
Renew as original emergency fire pump room vent.
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 19 August 2003
Resolution: RECEIVED CLASS SURVEY VIA FAX FROM VESSELS AGENT (T.P. HOST) STATING DUCTS NOW PERMANENTLY REPAIRED.
LR SURVEYOR: P.J. BEARD
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 5 August 2003
Resolved
Make repairs to to echo dept sounder recorder- corrected on the spot.
Due 5 August 2003
Resolved 5 August 2003
Resolution: Made repairs to dept sounder recorder.
Fire Fighting › Fixed Fire Detection System
Issued 5 August 2003
Resolved
Make repairs to fire detection system. To the sat of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2003
Documentation › Certificates/Documents
Issued 28 January 2002
Resolved
provide Fixed-Gas fire extinguishing system or an Exemption Certificate from the flag administration for the cargo holds. LEGACY COMPONENT DESC: Exemption Certificate (SOLAS)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2002
Resolved 3 February 2002
Fire Fighting › Miscellaneous Items
Issued 28 January 2002
Resolved
Remove excess oil from bilges , buckets and other sources in the engine room that create an elevated fire safety hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2002
Resolved 3 February 2002
Deck/Cargo
Issued 6 February 1996
Resolved
LUBE OIL CONTAINMENT FOR VENTS ON AFT DECKS NOT PRESENT.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Navigation
Issued 6 February 1996
Resolved
CHART 11370 HAD NO CORRECTIONS. THE LATEST CORRECTION TO CHART 11370 FOR THE AREA TRANSITED IS 52/95.
Condition: Unknown
Due 6 February 1996
Resolved 9 February 1996
Engineering
Issued 27 August 1993
Resolved
Vessel did not have flame screens installed in the fuel oil, lube oil or diesel oil tank vents.
Condition: Unknown
Due 14 February 1996
Resolved 14 February 1996
Documentation
Issued 27 August 1993
Resolved
Vessel did not have a waste management plan on board.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993