MAURY USCG vessel records Sign in
← All vessels

VIEJO SAN JUAN

VIEJO SAN JUAN is a 1990 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1990, most recently in June 2016, along with 142 deficiencies, 3 operational controls and 14 casualty investigations between 2005 and 2010.

Records from 1990 to 2016. Most recent: inspection, 1 June 2016.

Built
1990
Last inspected
1 June 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7396
343706
Flag
UNITED STATES
367070750 (licence lapsed)
Maury page id
psix-343706

Inspections, by type

…with no type recorded13
Years with a record 23 calendar years (1990–2016)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it87 - Simplified, Gross Ton
69 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7396MMSI 367070750 · expired · compulsorily equipped · granted 7 October 2005, cancelled 12 December 2015
WAN8093MMSI not assigned · expired · compulsorily equipped · granted 26 April 1995, cancelled 25 February 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CULEBRA II Passenger (Inspected) · MISLE 439445 · 19 May 2000 · activity 55288

Inspection history · 82

1 June 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5894022
12 December 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4206579
5 August 2011 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4106027
23 March 2010 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3701461
22 March 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3775088
19 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3671263
19 January 2010 Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3672702
15 January 2010 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3664584
13 January 2010 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3663094
13 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3663171
13 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3680886
10 December 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3648032
1 July 2009 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3521240
26 November 2008 In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3369780
9 October 2008 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3345750
9 October 2008 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3345924
2 November 2007 Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3091815
5 October 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3073721
1 June 2007 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2948395
1 June 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2948833
21 May 2007 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2936018
20 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2937339
24 April 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2914654
27 February 2007 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2878738
6 February 2007 Examination of Repairs · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2867893
4 August 2006 Examination of Repairs · Administrative Inspection · Damage Survey · Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2750072
10 March 2006 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2602120
9 December 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2548630
3 November 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2528215
21 June 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2397921
2 February 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2285641
1 February 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2285226
16 January 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2275718
13 January 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2274457
4 January 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2268954
14 August 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2165741
17 June 2004 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2107864
25 June 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1827468
7 May 2003 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1788146
30 April 2003 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1783399
12 March 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1751722
3 May 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1621992
7 May 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691593
23 April 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1428015
16 February 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1369983
19 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 55288
24 March 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410264
23 June 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1090937
12 April 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378635
13 July 1998 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406347
17 March 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394912
5 March 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1108811
3 March 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1402399
1 August 1996 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360602
31 July 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 76213
1 March 1996 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355484
11 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880644
27 February 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 853587
16 May 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 860424
8 March 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 855288
15 February 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1163672
7 February 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 852852
14 December 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 851636
26 November 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1426848
20 October 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1446022
20 September 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1403686
1 April 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1148199
29 January 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 960375
25 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 962794
25 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1132492
31 December 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1140370
29 December 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 830144
16 November 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 962232
23 July 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436697
17 January 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 961179
16 January 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1270310
24 October 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 933834
10 September 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1250826
23 July 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 936586
22 July 1991 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 935685
19 July 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1246125
27 March 1990 Plan Review "T" Boat · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 923938

Deficiency record · 142

Engineering › Diesel Engine (propulsion-reduction gear) › Charge Air Cooling
Issued 19 January 2010 Resolved
Prove proper operation of the port engine to the satisfaction of the attending mearine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2010
Engineering › Steering Gear System › Linkage
Issued 15 January 2010 Resolved
Replace SSTL Steering cables.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Steering cables replaced.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 15 January 2010 Resolved
Replace jacket water hoses on generator "soft".
Due 15 January 2010
Resolved 16 January 2010
Resolution: Jacket water hoses on generator have been replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 January 2010 Resolved
Replace flexible fuel hose stbd eng room IWO fuel shut off valve "cracked"
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified flexible fuel hose has been replaced.
Fire Fighting › Fire Pumps › Pressure
Issued 15 January 2010 Resolved
Replace faulty fire pump pressure gauge stbd eng room.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Fire pump pressure gauge replaced.
Fire Fighting › Fire Main › Condition
Issued 15 January 2010 Resolved
Make proper repairs to pin hole leak on stbd fire main IWO guage.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified proper repairs have been made to pin hole leak on stbd fire main IWO gauge.
Engineering › Reduction Gearing/Clutches › Bearing
Issued 15 January 2010 Resolved
Make proper repairs to oil leak on stbd MDE turbos bearing.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified proper repairs have been made to oil leak on stbd MDE turbos bearing.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 15 January 2010 Resolved
Tighten stbd shaft packing "excessive leakage"
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified shaft packing was tightened.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 January 2010 Resolved
Replace 27 Adult type I lifejackets.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified 27 adult type I lifejackets were replaced.
Engineering › Lubricating Oil Service System › Gauge
Issued 15 January 2010 Resolved
Make proper repairs/replace port MDE oil pressure gauge.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified proper repairs on gauge.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 January 2010 Resolved
Make proper repairs to leaking overhead IWO stbd fwd passenger compartment lighting.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified proper repairs made.
Engineering › Bilge Water Management System › Not Operational
Issued 15 January 2010 Resolved
Prove proper operation of installed bilge system.
Due 15 January 2010
Resolved 16 January 2010
Resolution: Verified proper operation of installed bilge system.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 January 2010 Resolved
Vessel was not made available to conduct its 1st annual exam within 90 days before or after the anniversary of the issuance of the COI. Vessel COI is invalid.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2010
Resolution: Vessel completed satisfactory COI inspection on 16Jan2010.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 June 2009 Resolved
Vessel's Shaft fractured and upon close-up inspection revealed pre-existing cracks which lead to eventual catastrophic failure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 1 July 2009
Resolution: Vessel''s shaft was replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 26 November 2008 Resolved
Generator is inoperable, Troubleshoot and repair and test.
Action required: 705 - Other - as specified
Due 3 December 2008
Resolved 3 December 2008
Resolution: Tested generator.SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 1 June 2007 Resolved
Repair or replace port side red gear, conduct sea trial with marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 2 June 2007
Resolution: Vessel repaired Port side Red gear, Marine Inspector conducted sea trials all found sat
Construction/Loadline › Hull › Hull Plating
Issued 21 May 2007 Resolved
Vessel had collision with pier port side bow area damage Vessel rep to submit repair proposal NLT 28 May 2007
Due 28 May 2007
Resolved 9 October 2008
Resolution: Repaired damage to port side bow area with an insert plate.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 24 April 2007 Resolved
Stop all leaks in passenger area overhead. (Currently leaking water out of ceiling in to electrical light fixtures)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2007
Resolution: Hose test sat repairs nad to the satisfaction of Marine Inspector.
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 February 2007 Resolved
Over board discharge pipe for main diesel generating cooling system is broke. Replace prior to taking on passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 February 2007
Resolved 27 March 2007
Resolution: Pipe has been replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 February 2007 Resolved
Instal/Replace machinery(engine) guards of port/starboard engines.
Due 24 March 2007
Resolved 9 October 2008
Resolution: Installed machinery guards on rotating machinery on main engines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 August 2006 Resolved
Replace fuel shutoff cable stbd side engine.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 22 August 2006
Resolution: Cable was replaced
Communications › Radio Communications › VHF Radiotelephone
Issued 22 August 2006 Resolved
Missing radiotelephony certificate.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 27 February 2007
Resolution: Certificate on board
Communications › Radio Communications › VHF Radiotelephone
Issued 22 August 2006 Resolved
Missing bridge to bridge certificate
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 27 February 2007
Resolution: Certificate on board
Construction/Loadline › Penetrations › Pipe Flange
Issued 4 October 2005 Resolved
Renew stern tubes and align shafts.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 4 August 2006
Resolution: Owner replaced stern tubes in kind.
Construction/Loadline › Hull › Bottom Plating
Issued 21 June 2005 Resolved
Forward port and Starboard, inner and outer shell plating of the bow turn needs to be cropped and renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 August 2005
Resolution: Completed and water pressure tested at 60 psi.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 21 June 2005 Resolved
Starboard 2nd watertight compartment inside, repair cracked welds of top 3 outboard side longitudal frames attached to forward watertight bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 July 2005
Resolution: New welds have been performed.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 June 2005 Resolved
Starboard forward 1st watertight compartment (aft of collision bulkhead), submitt repair proposal to secure through hull electriacl wiring leading outboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 July 2005
Resolution: Welded a patch to cover through hull. This spot is high above the waterline.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 21 June 2005 Resolved
Starboard aft 3rd watertight compartment (fuel tank compartment) repair cracked 3 welds on top 3 longitudal frames attached to froward watertight bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 July 2005
Resolution: New welds have been performed.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 June 2005 Resolved
Starboard and port fuel tank pipings, re-seal through hull fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 July 2005
Resolution: Through hull fittings have been renewed.
Engineering › Fuel Oil Service System › Piping
Issued 21 June 2005 Resolved
Starboard fuel tank, properly cap off old reserve tank piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 July 2005
Resolution: New caps have been installed.
Engineering › Fuel Oil Service System › Piping
Issued 21 June 2005 Resolved
Starboard and port fuel tank piping, renew pipe fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 July 2005
Resolution: New piping and fittings have been properly installed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 June 2005 Resolved
Submitt reapir proposal to replace severly corroded stern tubes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2005
Resolved 4 September 2005
Resolution: Vsl has submitted repair proposal.
Engineering › Reduction Gearing/Clutches › Gear
Issued 2 February 2005 Resolved
Port main propulsion unit not operational. Trouble shoot repair and prove proper operation of the port propulsion unit (apparent transmission failure)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2005
Resolved 1 April 2005
Fire Fighting › Combustible Materials › Insulation
Issued 2 February 2005 Resolved
Determine source of oil leak, repair and renew turbo charger blanket.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2005
Resolved 1 April 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 January 2005 Resolved
Fixed seating in passenger accommodation area in disrepair. Seats broken, not properly secured, not in accordance with approved plan. Properly secure existing seats and seating units. Loose and damaged units not to be used by passengers. Vessel limited to not more than 89 passengers
Action required: 705 - Other - as specified
Due 13 January 2005
Resolved 1 April 2005
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 13 January 2005 Resolved
Vessel name not properly marked on starboard bow. Properly mark vessel name on bow in accordance with 46CFR 67.123.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2005
Resolved 1 April 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 January 2005 Resolved
Restore all fixed seating as original in accordance with approved plan. In lieu of restoration submit plan approved by professional engineer for modified seating arrangement. Plan to include all material specs, attachments, and approvals. (seating should be constructed to withstand actual loading conditions expected)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 1 April 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 4 January 2005 Resolved
Label on/off engine alarm switch.
Due 11 January 2005
Resolved 5 January 2005
Resolution: Verified label
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 January 2005 Resolved
Fix Port side Engine Water Temperature gauge
Due 17 January 2005
Resolved 1 April 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 4 January 2005 Resolved
Fix wiper motor and prove proper operation
Due 17 January 2005
Resolved 5 January 2005
Resolution: Witnessed operational test of motor
Fire Fighting › Fire Main › Condition
Issued 4 January 2005 Resolved
Fire/Bilge pump discharge line leaking (spraying water) in starboard engine room. Repair discharge line and prove prove proper operation of pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2005
Construction/Loadline › Structures › Door
Issued 4 January 2005 Resolved
Fix emergency exit port side. Ensure that the door is permanently attached to door frame and replace dock.
Due 17 January 2005
Resolved 5 January 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2005 Resolved
Raplace forward port side engine compartment light cover
Due 17 January 2005
Resolved 5 January 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 17 June 2004 Resolved
Repair/ Replace emergency lights in Port Engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 13 August 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 June 2004 Resolved
Provide blanks breakers on the port engine room breaker panel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 17 June 2004
Communications › Radio Communications › EPIRB
Issued 17 June 2004 Resolved
Provide proof of Epirb registration
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2004
Resolved 17 June 2004
Resolution: owner rep provided proof of epirb registration.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 June 2003 Resolved
While the vessel is operating on a route other than protected waters the vessel must have an operable RADAR installed as required by 46 CFR 184.404.
Action required: 705 - Other - as specified
Due 26 June 2003
Resolved 13 August 2004
Communications › Radio Communications › EPIRB
Issued 7 May 2003 Resolved
Provide evidence of vessel's EPIRB registration w/ NOAA.
Due 7 May 2003
Resolved 13 August 2004
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 7 May 2003 Resolved
Repair Mens bathroom urinal's electric pump.
Due 22 May 2003
Resolved 13 August 2004
Construction/Loadline › Structures › Deck Plating
Issued 30 April 2003 Resolved
Gouge and re-weld fracture in weld on aft bottom support cup for rescue ladder.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Resolution: Fracture gouged and re-welded.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 30 April 2003 Resolved
Modify rescue ladder so that it rest in the supports mounted in deck. The forward bottom leg is cut to short and does not rest in support "cup".
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Resolution: Ladder repaired.
Engineering › Lubricating Oil Service System › Gauge
Issued 30 April 2003 Resolved
Correct problem with port engine oil pressure gauge reading being "pegged" (reading over 80 p.s.i. while the starboard gauge reads 40 p.s.i. while running).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Resolution: Sending unit replaced on engine.
Engineering › Reduction Gearing/Clutches › Gear
Issued 30 April 2003 Resolved
Identify and correct problem with starboard transmission pressure gauge reading being "pegged" at 350 p.s.i. while the port gauge reads 250 p.s.i. while running in gear.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 7 May 2003
Resolution: Clutch pack replaced.
Engineering › Steering Gear System › Rudder Bearing
Issued 30 April 2003 Resolved
Make repairs to steering system/gear to correct excessively stiff steering which result in difficulty maneuvering the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Resolution: Bearing in ruccer tubes "worked" to allow free movement.
Fire Fighting › Fire Main
Issued 12 March 2003 Resolved
SJ1: Renew holed pipe elbow and pitted flange face on the fire main piping in the port engine room. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2003
Resolution: Pipe renewed.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 12 March 2003 Resolved
SJ2: Renew screen on holding tank vent.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 March 2003
Resolution: Screen renewed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 March 2003 Resolved
SJ3: Renew hose clamps and flexible piping leading from head to holding tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2003
Resolution: Hose clamps and piping renewed.
Construction/Loadline › Hull › Hull Plating
Issued 12 March 2003 Resolved
SJ4: Gouge and re-weld fracture located on the upper aft outboard corner on the starboard side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 March 2003
Resolution: Fracture gouged adn re-welded.
Construction/Loadline › Hull › Bottom Plating
Issued 12 March 2003 Resolved
SJ5: Submit repair proposal for pitting in the aft starboard void (Holding tank space) bottom plate and delaminated frameing members and make repairs per proposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 April 2003
Resolution: Plans submitted for clad welding of pits. Pits clad welded and corroded framing renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 12 March 2003 Resolved
SJ6: Crop and renew delaminated/corroded section of outboard side-shell and transverse bilge bracket located in the bilge pocket forward of the sea chest in the port side engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 April 2003
Resolution: Corroded plating and framed renewed.
Engineering › Bilge Water Management System › Strainer
Issued 12 March 2003 Resolved
SJ7: Renew bilge strainer in the #2 port void.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 April 2003
Resolution: Strainer renewed.
Construction/Loadline › Hull › Hull Plating
Issued 12 March 2003 Resolved
SJ8: Crop and renew as original damaged section of side shell located in the port side #2 void just below the rub-rail.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 April 2003
Resolution: Damaged section renewed.
Construction/Loadline › Hull › Hull Plating
Issued 12 March 2003 Resolved
SJ9: Gouge and re-weld fracture located on the aft side of the aft pad eye on the port side propagated from the gunwale into the side plate.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 April 2003
Resolution: Fractures gouged and rewelded.
Electrical › Electrical Distribution System (service)
Issued 3 May 2002 Resolved
Reinstall Generator starting battery back in its original position next to generator. LEGACY COMPONENT DESC: Starting Battery
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 21 May 2002
Resolution: Battery reinstalled in original position next to generator.
Lifesaving › Embarkation Appliances/Stations
Issued 3 May 2002 Resolved
Modify rescue ladder so that it rest in the supports mounted in deck to prevent side to side movement. LEGACY COMPONENT DESC: Rescue Platform
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 21 May 2002
Resolution: Mounts modified to secure ladder.
Fire Fighting
Issued 23 April 2001 Resolved
During the annual inspection discovered that the aluminum firemain piping in the starboard engine room had a hole that was covered with a thin layer of epoxy, sanded, and painted over with aluminum spray paint in an attemp to hide the unauthorized repair._x001C_
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Fire Fighting
Issued 23 April 2001 Resolved
Repair/renew both fire pump relief valves (60 p.s.i.).
Condition: Unknown
Due 23 May 2001
Resolved 3 May 2002
Resolution: Relief valves tested sat during inspection.
Electrical
Issued 16 February 2001 Resolved
Repair losse light explosion proof fixture in starboard aft space (sewage tank space).
Condition: Unknown
Due 16 February 2001
Resolved 19 April 2001
Construction/Loadline
Issued 16 February 2001 Resolved
Crop and renew hull side plating at port and starboard tail shaft alley.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Navigation
Issued 16 February 2001 Resolved
Replace bearing on rudders (port/starboard).
Condition: Unknown
Due 16 February 2001
Resolved 19 April 2001
Construction/Loadline
Issued 16 February 2001 Resolved
In way of previously installed AC system plug/blank piping/cable through hull/stuffing tube holes for throughout vessel.
Condition: Unknown
Due 16 February 2001
Resolved 19 April 2001
Documentation
Issued 24 March 2000 Resolved
Produce Training Log book to record required training for crewmembers. 46 CFR 185.420
Condition: Unknown
Due 24 March 2000
Resolved 27 March 2000
Accommodation/Occupational Safety
Issued 24 March 2000 Resolved
Noted that several passenger windows had been replaced without providing passengers a means of opening or closing the windows. Also noted one windoww / excessive cantenary due to oversized plexiglass. 46 CFR 177.1010/177.800
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Electrical
Issued 24 March 2000 Resolved
Replace portside engine room light cover. 46 CFR 183.410
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Construction/Loadline
Issued 24 March 2000 Resolved
Noted that port & starboard bilge pumps could not take suction without manual priming by engineer. 46 CFR 176.804/182.520
Condition: Unknown
Due 24 March 2000
Resolved 27 March 2000
Accommodation/Occupational Safety
Issued 24 March 2000 Resolved
Replace piping for wet-cooling system. If system is removed and dry system is installed, ensure generator and all associated electrical systems are rated for new system. Submit proposal before work is conducted. 46 CFR 182.720
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Documentation
Issued 24 March 2000 Resolved
Produce Bridge log to record required drills and testing of alarms. 46 CFR 185.702
Condition: Unknown
Due 24 March 2000
Resolved 27 March 2000
Accommodation/Occupational Safety
Issued 24 March 2000 Resolved
Noted portside outboard hand rail to have broken weldment, 2nd from stern._x001C_46 CFR 177.900
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Engineering
Issued 24 March 2000 Resolved
Make permanent repair to portside fuel vent piping that is temporarily repaired w/ rubber hosing and clamps. 46 CFR 182
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Accommodation/Occupational Safety
Issued 24 March 2000 Resolved
Noted that front row of seats had been removed from passenger accomadation area reducing seating capacity by 10. Vsl to reinstall seating or COI to be ammended to reduce passenger seating capacity. 46 CFR 177.820
Condition: Unknown
Due 24 March 2000
Resolved 27 March 2000
Lifesaving
Issued 24 March 2000 Resolved
Noted that first aid kit was not fully stocked. 46 CFR 184.710
Condition: Unknown
Due 24 March 2000
Resolved 27 March 2000
Fire Fighting
Issued 24 March 2000 Resolved
Noted that the required Portable fire extinguishers in both engine room to have not been serviced. 46 CFR 176.810
Condition: Unknown
Due 24 March 2000
Resolved 27 March 2000
Accommodation/Occupational Safety
Issued 12 April 1999 Resolved
REPAIR AIR CONDITIONING UNITS.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
PROVIDE CORROSION RESISTANT CLIP FOR LIGHTED RING BUOY AND PROPER DARK LINE.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Construction/Loadline
Issued 12 April 1999 Resolved
INSTALL HIGH BILGE WATER LEVEL ALARMS AS PER 46CFR180.530 MEANWILE CONDUCT HOURLY ROUNDS AND LOG IN SHIPS LOG.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Documentation
Issued 12 April 1999 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 17 March 1998 Resolved
RENEW BOUYANT LINE ON FORWARD LIFE RING
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Engineering
Issued 17 March 1998 Resolved
REPAIR LEAKING OIL DRAIN LINE FROM STBD ENGINE OUTBOARD TURBOCHARGER
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Electrical
Issued 17 March 1998 Resolved
SECURE COVER ON ENGINE START SOLENOID JUNCTION BOX AND ENSURE ALL WIRES PASS THROUGH STUFFING TUBES
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 17 March 1998 Resolved
ENSURE VESSEL NAME IS STENCILED ON ALL LIFE JACKETS
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 17 March 1998 Resolved
PROVIDE CG APPROVED FIRST AID KIT
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Fire Fighting
Issued 3 March 1997 Resolved
REPLACE BRACKET TO FIRE EXTINGUISHER IN STARBOARD ENGING ROOM.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Electrical
Issued 3 March 1997 Resolved
PROVE PROPER OPERATION OF HERTZ AND AMP GAUGES AT GENERATOR.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Electrical
Issued 3 March 1997 Resolved
REPAIR AS ORIGINAL AIR FILTER FOR GENERATOR.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 3 March 1997 Resolved
PROVIDE REFLECTIVE TAPE TO RING BUOY LOCATED ON BOW.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 1 August 1996 Resolved
PROVE PROPER OPERATION OF BOTH MAIN ENGINE TRANSMISSIONS INCLUDING PILOT HOUSE CONTROL. COMPLETE PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 1 August 1996
Resolved 16 October 1996
Electrical
Issued 1 August 1996 Resolved
LABEL PORT AND STBD GAUGE SWITCHES IN PILOT HOUSE, HORN SWITCH AND COMPASS LIGHT SWITCH.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Construction/Loadline
Issued 1 August 1996 Resolved
PLUG THE 2 KICK PIPES UNDER THE CONSOLE IN THE PILOT HOUSE, PORT SIDE, FORWARD.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Construction/Loadline
Issued 1 August 1996 Resolved
CROP AND RENEW DAMAGED BULL NOSE AND DAMAGED AREA OF THE BOW.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 1 March 1996 Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Electrical
Issued 1 March 1996 Resolved
PROPERLY LABEL ALL BREAKER PANEL DOORS WITH BREAKER IDENTIFICATION.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Electrical
Issued 1 March 1996 Resolved
REMOVE ALL UNUSED WIRES UNDER PILOT HOUSE COUNSEL.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Fire Fighting
Issued 1 March 1996 Resolved
REMOVE UNUSED HALON PANEL AT PILOT HOUSE.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Electrical
Issued 1 March 1996 Resolved
PROVE PROPER OPERATION OF ALL GENERATOR GAUGES IN ENGINE ROOM AND PILOT HOUSE.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Construction/Loadline
Issued 1 March 1996 Resolved
REPAIR/ADJUST PORT AND STBD MAIN DECK AFT SLIDING DOORS.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Electrical
Issued 1 March 1996 Resolved
RENEW SWITCH TO SEWAGE (MSD) PUMP.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Electrical
Issued 1 March 1996 Resolved
RENEW SWITCH FOR SALT WATER TO URINAL PUMP.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Accommodation/Occupational Safety
Issued 1 March 1996 Resolved
PROVE PROPER OPERATION OF FEMALE MSD DEVICE.
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Engineering
Issued 7 February 1994 Resolved
MAKE PERMANANT REPAIRS TO PORT ENGINE RAW WATER OVERBOARD LINE.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Electrical
Issued 7 February 1994 Resolved
VERIFY ELECTRICAL INSTALLATION OF GENERATOR WIRING IS IN ACCORDANCE WITH APPROVED ELECTRICAL DRAWINGS. FIND CAUSE OF ELECTRICAL SHORT INTO BRIDGE GAUGE PANEL.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Electrical
Issued 7 February 1994 Resolved
MAKE PROPER CORRECTIONS TO WIRING CONNECTIONS AND SPLICES AS DISCUSSED.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 7 February 1994 Resolved
REMOVE EXCESSIVE OIL FROM PORT AND STARBOARD ENGINE ROOM BILGES.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Electrical
Issued 7 February 1994 Resolved
REPLACE STUFFING ON ELECTRICAL WIREWAYS INTO ENGINE ROOMS.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Engineering
Issued 7 February 1994 Resolved
LOCATE AND FIX OIL LEAK ON STARBOARD ENGINE.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Accommodation/Occupational Safety
Issued 7 February 1994 Resolved
MAKE PERMANANT REPAIRS TO URINAL DRAIN LINE.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 26 November 1993 Resolved
Provide system that lets buoyant apparatus float free. 46CFR180.20
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 20 October 1993 Resolved
CROP AND RENEW THROUGH HULL PENETRATIONS FOR BOTH MAIN PROPULSION ENGINE SALT WATER OVERBOARD DISCHARGES.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Documentation
Issued 20 October 1993 Resolved
DEMONSTRATE A SATISFACTORY CHEMICAL TESTING PROGRAM HAS BEEN ESTABLISHED INACCORDANCE WITH 46 CFR 16.260. (Testing requirements are listed in 46 CFR 16.201)
Condition: Unknown
Due 20 October 1993
Resolved 20 October 1993
Lifesaving
Issued 20 October 1993 Resolved
CLEAN OIL FROM BULKHEADS, EXHAUST VENT FANS AND DUCTS AND BILGES.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Fire Fighting
Issued 20 October 1993 Resolved
CROP AND RENEW 90 DEGREE ELBOWS ON DISCHARGE SIDE OF PORT AND STARBOARD FIREPUMPS.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Fire Fighting
Issued 20 October 1993 Resolved
PROVE PROPER OPERATION OF PORT FIRE PUMP GAUGE.
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Engineering
Issued 20 October 1993 Resolved
RELOCATE THE EMERGENCY FUEL OIL SUPPLY SHUT OFF VALVES SO THAT THEY ARE LOCATED AT THE FUEL TANKS. REMOTE OPERATION FROM OUTSIDE THE SPACE IS STILLREQUIRED.
Condition: Unknown
Due 20 October 1993
Resolved 20 October 1993
Engineering
Issued 20 October 1993 Resolved
REMOVE FUEL OIL TANK DRAIN AND CAP LINE AT TANK. PROPERLY PLUG HOLE AT BULKHEAD IN BOTH PORT AND STARBOARD HULLS.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Engineering
Issued 20 October 1993 Resolved
CROP & RENEW STARBOARD ENGINE SALT WATER COOLING OVERBOARD DISCHARGE THROUGH-HULL FITTING.
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Construction/Loadline
Issued 20 September 1993 Resolved
Port and Starboard engine rooms: Renew through hull fitting fro MDE R/W overboard discharge.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Fire Fighting
Issued 20 September 1993 Resolved
Crop and renew discharge side of fire pump piping in port and starboard engine rooms.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Navigation
Issued 20 September 1993 Resolved
Renew bearings on port and starboard rudders.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Electrical
Issued 29 January 1993 Resolved
REPLACE STUFFING IN PORT & STBD WIREWAYS TO ENGINE ROOMS.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Electrical
Issued 29 January 1993 Resolved
PROVE PROPER OPERATION OF GENERATOR GUAGES ON BRIDGE AND LOCAL CONTROL PANEL.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Engineering
Issued 29 January 1993 Resolved
RE-ROUTE AND SUPPORT NEW TRANSMISSION CABLES TO MAIN ENGINES.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Lifesaving
Issued 29 December 1992 Resolved
Prior to carrying passengers present vessel for inspection of safety equipment and machinery systems.
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Electrical
Issued 23 July 1992 Resolved
Tighten all stuffing tubes for electrical wiring throughout vessel.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Construction/Loadline
Issued 23 July 1992 Resolved
In #1P tank, crop and insert approx. 4' x 3' section between frames 1 and 4as marked. In same area, replace #3 side long as marked.
Condition: Unknown
Due 1 September 1992
Resolved 16 November 1992
Construction/Loadline
Issued 23 July 1992 Resolved
In #2P tank, crop and insert 18" x 24" on outboard sideshell in way of fwd bulkhead extending into #1P as marked. Crop & insert fwd bulkhead as marked.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Fire Fighting
Issued 24 October 1991 Resolved
MAKE PERMANENT REPAIRS AND PROVE PROPER OPS TO INSTALLED FIREPUMP. FIREPUMPDISCHARGE MUST BE 50 GPM AT 60 PSI IAW 46CFR181.10-1(c) AND WITH ENG RPM NOT EXCEEDING MANUFACTURES RECOMMENDATION. IF SYSTEM CAN'T MEET ABOVE REQ, PUMP MUST BE RENEWED W/A UNIT THAT IS RATED FOR THIS SERVICE.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Fire Fighting
Issued 10 September 1991 Resolved
MAKE PERM REPAIRS AND PROVE PROPER OPS OF INSTALLED FIREPUMP. FIREPUMP DISCHARGE MUST BE 50 GPM AT 60 PSI IAW 46 CFR 181.10-1(C) & AT AN ENG RPM NOT EXCEEDING MANUFACTURES RECOMMENDATION. IN PRESENT INSTALLED SYS CAN'T MEET ABOVE REQ'S, PUMP MUST BE RENEWED W A UNIT THAT IS RATED FOR THIS SVC.
Condition: Unknown
Due 10 September 1991
Resolved 10 September 1991
Fire Fighting
Issued 22 July 1991 Resolved
REPLACE STBD E/R FIRE/BILGE PUMP GAUGE & PROVE PROPER OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Navigation
Issued 22 July 1991 Resolved
PROVIDE THE FOLLOWING PUBLICATIONS: 46 CFR PARTS 166-199 CHART OF AREA OF OPERATION, AND RULES OF THE ROAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Electrical
Issued 22 July 1991 Resolved
PROVIDE DOCUMENTATION SHOWING THAT SEA VALVE FOR S/S GENERATOR COOLING COAST GUARD APPROVED (CATOGORY A)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
PROVIDE STABILITY LETTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 August 1991
Resolved 27 September 1991
Construction/Loadline
Issued 22 July 1991 Resolved
MAKE PERMANENT REPAIRS TO P/S BOW STEMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 August 1991
Resolved 27 September 1991
Fire Fighting
Issued 22 July 1991 Resolved
CONDUCT FIRE/MAN OVERBOARD DRILLS IN PRESENCE OF USCG INSPECTOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991

Casualty record · 14

1 February 2005Routine · role: Involved in a Marine Casualty · activity 2285226
18 November 2006Routine · role: Involved in a Marine Casualty · activity 2826846
4 December 2006Routine · role: Involved in a Marine Casualty · activity 2838637
14 December 2006Routine · role: Involved in a Marine Casualty · activity 2842926
20 May 2007Routine · role: Involved in a Marine Casualty · activity 2937339
1 June 2007Routine · role: Involved in a Marine Casualty · activity 2948833
29 June 2009Routine · role: Involved in a Marine Casualty · activity 3521039
19 January 2010Routine · role: Involved in a Marine Casualty · activity 3671263
22 March 2010Routine · role: Involved in a Marine Casualty · activity 3775088
2 May 2010Routine · role: Involved in a Marine Casualty · activity 3730187
11 June 2010Routine · role: Involved in a Marine Casualty · activity 3763808
4 July 2010Routine · role: Involved in a Marine Casualty · activity 3837904
12 July 2010Routine · role: Involved in a Marine Casualty · activity 3853431
12 July 2010Routine · role: Involved in a Marine Casualty · activity 3853648
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.