MAURY USCG vessel records Sign in
← All vessels

CULEBRA II

CULEBRA II is a 1996 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1996, most recently in June 2023, along with 242 deficiencies, 2 operational controls and 6 casualty investigations between 2004 and 2010.

Records from 1996 to 2023. Most recent: inspection, 12 June 2023.

Built
1996
Last inspected
12 June 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9068914 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD3930
439445
Flag
UNITED STATES
367138210 (licence lapsed)
Maury page id
psix-439445

Inspections, by type

…with no type recorded11
Years with a record 19 calendar years (1996–2023)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)126.9 ft × 29.5 ft × 12.0 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)126.9 ft × 29.5 ft × 12.0 ft
ITC tonnagegross 493 / net 203
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1996
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
493 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
203 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD3930MMSI 367138210 · expired · compulsorily equipped · granted 6 September 2006, cancelled 12 November 2016
WCW8264MMSI not assigned · expired · compulsorily equipped · granted 22 August 1996, cancelled 29 October 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

VIEJO SAN JUAN Passenger (Inspected) · MISLE 343706 · 19 May 2000 · activity 55288

Inspection history · 75

12 June 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7713466
22 June 2017 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6100472
12 February 2016 Examination of Repairs · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5827567
8 December 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4204320
4 March 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3781467
19 February 2010 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3686256
5 February 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3676784
5 February 2010 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3689730
29 January 2010 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3672594
23 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3669241
28 December 2009 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3656462
17 December 2009 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3652413
9 December 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3647272
3 December 2009 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3644268
22 January 2009 In-Service Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3400290
3 April 2008 Plan Review (Other than "T")
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3176913
31 January 2008 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3139435
19 July 2007 Deficiency Check · Load Line/Change of Employment
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3000146
22 March 2007 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2892594
31 January 2007 Deficiency Check · MTSA Verification · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2864572
25 October 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2783522
5 September 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2771675
22 June 2006 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2724065
10 April 2006 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2621682
10 February 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2583056
2 February 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2578049
17 January 2006 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2568327
6 December 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2546715
2 November 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2530703
9 October 2005 In-Service Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2508936
26 August 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2475629
11 August 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2468081
11 August 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2468105
15 July 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2427576
18 March 2005 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2314609
10 December 2004 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2290529
19 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2199293
8 July 2004 MTSA Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2126507
5 July 2004 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2122098
3 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2140149
17 June 2004 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2101094
27 May 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2079824
24 May 2004 In-Service Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2076568
10 October 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1925796
14 September 2003 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1913515
14 September 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1927887
31 July 2003 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1864529
17 June 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1849197
23 April 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1779642
9 February 2003 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1742183
20 March 2002 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1494818
8 February 2002 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1487444
29 December 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1474455
3 December 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1076771
15 August 2001 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1077162
7 August 2001 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1069881
30 May 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 219375
18 May 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1428027
5 April 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1408682
19 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 55288
19 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 174612
30 March 2000 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1450443
22 July 1999 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 773424
23 June 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1090712
4 May 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1128487
31 March 1999 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404701
24 December 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 807412
5 November 1998 Drydock Extension · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 811008
18 August 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 796367
1 December 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 775109
20 November 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368489
8 November 1997 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372027
19 June 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 776091
7 November 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1357778
23 October 1996 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427274

Deficiency record · 242

Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 March 2010 Resolved
Prove proper operation of #2 Generator.
Action required: 705 - Other - as specified
Due 10 March 2010
Resolved 10 March 2010
Resolution: Verified proper operation of #2 generator.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 5 February 2010 Resolved
Make proper repairs to secondary sprinkler pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2010
Construction/Loadline › Structures › Deck Plating
Issued 5 February 2010 Resolved
Provide repair proposal for cracked main deck in way of aft stbd center stantion/
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 January 2010 Resolved
Vessel is restriced to 500 total persons on board vessel until proper 527 lifejackets are provided to the satisfaction of attending Marine inspector.
Due 28 February 2010
Resolved 18 May 2010
Resolution: Proper life jackets were provided.
Engineering › Lubricating Oil Service System › Inlet
Issued 29 January 2010 Resolved
Adress oil leak on #1 MDE air box from turbo.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 18 May 2010
Resolution: Oil leaks rectified.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2009 Resolved
Repair raw water flex hose fitting for starboard outboard engine prior to carrying passengers.
Action required: 705 - Other - as specified
Due 28 December 2009
Resolved 28 December 2009
Resolution: Verified fitting repaired.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 December 2009 Resolved
Repair exhaust leaks in rudder room on both port and starboard side prior to carrying passengers.
Action required: 705 - Other - as specified
Due 28 December 2009
Resolved 28 December 2009
Resolution: Exhaust leaks repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2009 Resolved
The two port engines need bracket supports for the raw water piping within 30 days.
Action required: 705 - Other - as specified
Due 27 January 2010
Resolved 29 January 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 May 2009 Resolved
Prove proper operation of bilge system and properly repair bilge manifold system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Resolution: Bilge system operational.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 May 2009 Resolved
Properly repair all exhaust leaks for all four engine exhaust piping and properly clean the aft three compartments of dirt and exhaust deterioration prior to getting underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Resolution: Exhaust leaks repaired.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 1 May 2009 Resolved
Provide new drip shield for sprinkler system distribution panel.
Action required: 705 - Other - as specified
Due 30 December 2009
Resolved 30 December 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 1 May 2009 Resolved
Properly address AC filter leak stbd side sprinkler tank room.
Action required: 705 - Other - as specified
Resolved 30 December 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 May 2009 Resolved
Conduct Annual inspection that was required in accordance with current COI that has surpassed it's 90 day window prior to re-issuance of the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Resolution: COI exam completed.
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 26 January 2009 Resolved
Low / high level high alarm on sprinkler tank is inoperable.Repair/replace,test.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 22 May 2009
Resolution: Alarm tested, all sat.
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 26 January 2009 Resolved
Battery charger for alarm panel is in operable. Repair/replace/test.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 22 May 2009
Resolution: Battery charger replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 26 January 2009 Resolved
Port engineroom fan is inoperable.Repair/replace/test
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 22 May 2009
Resolution: Fan repaired.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 January 2009 Resolved
Remove all loose parts and debri from vessel.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 22 May 2009
Resolution: Gear adrift secured.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 January 2009 Resolved
Oil leaks from all 4 engines drain pans. Repair/Replace gaskets.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 22 May 2009
Resolution: Leaks secured.
Fire Fighting › Ventilation Systems › Ducts
Issued 31 January 2008 Resolved
1. Repair manual closure of fire dampers (inoperable).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: CORRECTED.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 January 2008 Resolved
2. Label stbd fuel cutoff .
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Stability › Intact Stability (when using lifting gear) › General
Issued 31 January 2008 Resolved
3. [name withheld] deck for max passenger capacity allowed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 January 2008 Resolved
4. Remove wing nuts and clean corrosion from battery terminals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 31 January 2008 Resolved
5. Reinstall missing electrical mat in front of electrical panel by generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 January 2008 Resolved
6. Repair inoperable remote fuel cuttoff valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Conductor
Issued 31 January 2008 Resolved
7. Reroute wiring feeding #1 alternator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Conductor
Issued 31 January 2008 Resolved
8. Remobe excess wiring laying in engineroom bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 31 January 2008 Resolved
9. Mark lifesaving equipment on Bow. (lifejackets)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 January 2008 Resolved
10. Separate and label child lifejackets thruout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 January 2008 Resolved
11. Install protective machinery guards on engineroom blowers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 January 2008 Resolved
12. Repair leaking no# 4 exhaust in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 31 January 2008 Resolved
13. Label electrical panel on bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Lighting (service) › Conductor
Issued 31 January 2008 Resolved
14. Replace speaker wiring under bridge.
Action required: 705 - Other - as specified
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Conductor
Issued 31 January 2008 Resolved
15. Remove all dead end wiring under bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2008
Resolution: Corrected.
Engineering › Bilge Water Management System › Interface Detector
Issued 31 January 2008 Resolved
16. Repair inoperative fore peak bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 January 2008 Resolved
17. Remove excess batteries adrift in engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Supply System (service) › Cable
Issued 31 January 2008 Resolved
18. Remove dead end wiring in pilothouse
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 31 January 2008 Resolved
19. Reinstall 113 missing adult lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corected.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 31 January 2008 Resolved
20. Remove excess trash and tools from engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 19 July 2007 Resolved
Provide missing EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Lifesaving › Hand Flares › Expired
Issued 19 July 2007 Resolved
Provide 6 missing orange smoke signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 19 July 2007 Resolved
Provide operational engine control back up system for engine control back up system on engines #4 and 1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 July 2007 Resolved
Renew all passenger seat covers.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: All seat covers were renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 July 2007 Resolved
Renew all oil soaked & deteriorated insulation in engineroom exhaust piping once piping renewed.
Action required: 705 - Other - as specified
Resolved 1 February 2008
Resolution: Corrected.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 19 July 2007 Resolved
Rebuild or renew both ship service generators at next drydock.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Both ship service generators were replaced with new generators.
Engineering › Bilge Water Management System › Piping
Issued 19 July 2007 Resolved
Renew all corroded bilge piping and valves thruout vessel at next drydock.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Bilge piping was renewed.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 19 July 2007 Resolved
Secure extrra adrift batteries in engineroom.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Construction/Loadline › Penetrations › Gasket
Issued 19 July 2007 Resolved
Repair hydraulic leak on WTD in engineroom at next drydock.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Ram on sliding WTD was sent out and renewed. Hydraulic leak was repaired.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 July 2007 Resolved
Repair inoperational bow thruster at next drydock
Action required: 705 - Other - as specified
Resolved 1 February 2008
Resolution: Corrected.
Construction/Loadline › Penetrations › Gasket
Issued 19 July 2007 Resolved
Remove and reseal all leaking windows.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: All leaking windows were repaired.
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 July 2007 Resolved
Provide publications required for navigation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Stability › Unintentional Flooding › General
Issued 19 July 2007 Resolved
Provide repair proposal to correct leak in STBD fin stabilizer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 22 March 2007 Resolved
Repaired cracked muffler on engine #1.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2008
Resolution: Muffler was repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 March 2007 Resolved
Rebuild all A/C strainers during next drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2008
Resolution: A/C strainers were rebuilt.
Fire Fighting › Fire Pumps › Pressure
Issued 22 March 2007 Resolved
Renew firepump gauge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2007 Resolved
Repair 2 inoperative lights on liferings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2007
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 22 March 2007 Resolved
Repair a/c ventilation on lower bathrooms.
Action required: 705 - Other - as specified
Resolved 1 February 2008
Resolution: Corrected.
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 March 2007 Resolved
Service 2 expired 50 person liferafts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2007
Construction/Loadline › Penetrations › Gasket
Issued 22 March 2007 Resolved
Repair inoperative engineroom water tight door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 31 January 2007 Resolved
Repair and realign #1 and #2 engines and engine mounts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2007
Engineering › Bilge Water Management System › Pump
Issued 31 January 2007 Resolved
Repair inoperative bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 31 January 2007 Resolved
Reinstall #2 generator governor emergency shutdown. (current ones disconnected).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 31 January 2007 Resolved
Repair rubber exhaust coupling on engine #4 (current one leaking exhaust and water).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 31 January 2007 Resolved
Repair A/C Ventilation system in fwd passenger room. Meanwhile passenger count lowered to -147 passengers due to area not having windows that can open.
Due 17 February 2007
Resolved 12 February 2007
Engineering › Bilge Water Management System › Valve
Issued 31 January 2007 Resolved
Repair broken handle on bilge system priming valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 31 January 2007 Resolved
Repack all excessive leaking shaft packings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 October 2006 Resolved
Repair #1 MDE muffler and #2 SSG muffler leak
Due 27 October 2006
Resolved 26 November 2006
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 7 September 2006 Resolved
Repair a/c system in second floor meanwhile COI Passenger count lowered to - 67 passengers
Due 20 September 2006
Resolved 26 October 2006
Documentation › Certificates/Documents › FCC SSL
Issued 7 September 2006 Resolved
Renew expired FCC Station License.
Due 26 October 2006
Resolved 26 October 2006
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 7 September 2006 Resolved
Repair inoperative #2 main diesel engine.
Due 20 September 2006
Resolved 22 September 2006
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 5 September 2006 Resolved
Repair #1 MDE muffler and #2 SSG muffler water leak.
Due 27 October 2006
Resolved 26 November 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 June 2006 Resolved
Provide evidence of random drug testing for all crew.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 22 June 2006 Resolved
Repair windshield wiper.
Due 22 July 2006
Resolved 26 November 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 June 2006 Resolved
Post new lifejacket donning placard in 3rd level.
Due 22 July 2006
Resolved 26 November 2006
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 22 June 2006 Resolved
Service #2 engine checkengine light.
Due 22 July 2006
Resolved 26 November 2006
Communications › Radio Communications › EPIRB
Issued 22 June 2006 Resolved
Renew hydrostatic release on EPIRB.
Due 22 June 2006
Resolved 22 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 June 2006 Resolved
Correct raw water leak on muffler piping for engine #4.
Due 22 July 2006
Resolved 26 November 2006
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 22 June 2006 Resolved
Provide servicing report attesting to good condition of sprinkler system tank and relief valves.
Due 22 July 2006
Resolved 26 November 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankcase
Issued 10 April 2006 Resolved
Repair # 2 ship service generator rear main oil seal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 April 2006 Resolved
Repair all exhaust leaks and crop and renew corroded areas in exhaust piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2006
Construction/Loadline › Penetrations › Gasket
Issued 10 April 2006 Resolved
Repair inoperative engineroom water tight door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2006
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 10 April 2006 Resolved
Repair all engines starting system as to be able to start from bridge as designed.
Action required: 705 - Other - as specified
Resolved 11 April 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 2 February 2006 Resolved
Make permanent repairs to stbd exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2006
Resolution: Exhaust has been repaired
Construction/Loadline › Structures › Door
Issued 2 February 2006 Resolved
Prove proper operation to eng room watertight door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2006
Resolution: WTD operates properly.
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 17 January 2006 Resolved
Repair exhaust leak in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, Positive Displacement
Issued 17 January 2006 Resolved
Correct major lube oil leak on #1 ship service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2006
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 17 January 2006 Resolved
Renew all leaking lube oil hoses on oil filter housing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2006
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 17 January 2006 Resolved
Repair inoperative windshield wipers.
Action required: 705 - Other - as specified
Due 23 January 2006
Resolved 18 January 2006
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 17 January 2006 Resolved
Provide operational GPS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2006
Engineering › Bilge Water Management System › Pump
Issued 17 January 2006 Resolved
Remove all oily water from bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2006
Engineering › Diesel Engine (auxiliary) › Governor
Issued 2 November 2005 Resolved
Repair all alarms and emergency shutdowns as per original design on both generators. And renew all inoperative gauges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 2 November 2005 Resolved
Repair fire alarm panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2005
Engineering › Diesel Engine (auxiliary) › Block
Issued 2 November 2005 Resolved
Repair ship service generator mixing oil and cooling water (Genset has cracked piston liner due to overheating casualty)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 9 October 2005 Resolved
Remove and renew #1 broken shaft. Provide repair proposal for #1 broken shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 August 2005 Resolved
Engine room water tight door hydraulic ram leaking excessive, repair replace ram
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2005
Resolved 27 August 2005
Stability › Incline Test › General
Issued 26 August 2005 Resolved
COI passenger count lowered due to fixed seating arrangement. Total passengers loaded are 564 if 3rd deck space along rail is used. If vessel use 1st & 2nd floor only max passengers is 535.
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 31 October 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 11 August 2005 Resolved
Repair A/C in pilothouse.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 August 2005 Resolved
Renew broken muffler on #3 MDE leaking in to passenger area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Engineering › Steering Gear System › Piping
Issued 11 August 2005 Resolved
Repair hydraulic steering leak in pilothouse.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 11 August 2005 Resolved
Renew stbd light fixture on fwd section of vessel.
Action required: 705 - Other - as specified
Due 18 August 2005
Resolved 27 August 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 11 August 2005 Resolved
Renew all 3 shorted a/c pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 August 2005 Resolved
Renew missing cover on A/C controller in space.
Due 7 December 2005
Resolved 18 January 2006
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 11 August 2005 Resolved
Repair water leak in #2 aft muffler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Engineering › Bilge Water Management System › Not Installed
Issued 11 August 2005 Resolved
Provide operational bilge alarm system for a/c pumps bilge space.
Action required: 705 - Other - as specified
Due 24 September 2005
Resolved 31 October 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 15 July 2005 Resolved
Renew broken port pilothouse windows.
Action required: 705 - Other - as specified
Due 23 July 2005
Resolved 31 October 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 15 July 2005 Resolved
Repair a/c system in pilothouse.
Action required: 705 - Other - as specified
Resolved 12 August 2005
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 15 July 2005 Resolved
Repair all vessel spotlights.
Action required: 705 - Other - as specified
Due 23 July 2005
Resolved 31 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 15 July 2005 Resolved
repair all 4 overheating engines.
Action required: 705 - Other - as specified
Due 23 July 2005
Resolved 27 August 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 July 2005 Resolved
install missing door lock in passenger cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 March 2005 Resolved
Post all Certificate of Inspection pages.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 18 March 2005 Resolved
Renew battery for fixed fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Communications › Audible Communications › Horn/Whistle
Issued 18 March 2005 Resolved
Repair inoperative ships horn.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 18 March 2005 Resolved
Repair portside wiper breaquer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 18 March 2005 Resolved
Repair all security / Fire detecting cameras.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Fire Fighting › Fire Hoses › Location
Issued 18 March 2005 Resolved
Install missing fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 March 2005 Resolved
Repair all inoperational toilets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 18 March 2005 Resolved
Repair anchor winch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 18 March 2005 Resolved
Double clamp all exhaust pipes in engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2005 Resolved
Repair compass light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 18 March 2005 Resolved
Repair A/C system in all inop areas thru vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 March 2005 Resolved
Conduct man overboard and fire drill to satisfaction of CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2005
Resolved 20 March 2005
Engineering › Thrusters › Motor
Issued 18 March 2005 Resolved
Test Bowthruster in presence of CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2005
Construction/Loadline › Hull › Hull Plating
Issued 11 February 2005 Resolved
Renew all hull zinc anodes.
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Construction/Loadline › Penetrations › Weld
Issued 11 February 2005 Resolved
Submit repair proposal for both cracks above fwd doors.
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Construction/Loadline › Structures › Door
Issued 11 February 2005 Resolved
Renew cracked port fwd door window.
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 11 February 2005 Resolved
Renew corroded port engineroom vent housing.
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 February 2005 Resolved
Remove both fire pump valves and strainer housing for inspection.
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Construction/Loadline › Hull › Hull Plating
Issued 11 February 2005 Resolved
Submit repair proposal for hole in bulkhead from a/c to bathroom space due to corrsion
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 February 2005 Resolved
provide liferaft servicing sticker on all liferafts.
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Engineering › Reduction Gearing/Clutches › Casing
Issued 5 July 2004 Resolved
Provide underwater survey to cg inspector prior to transit to drydock.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2004
Resolved 3 August 2004
Engineering › Reduction Gearing/Clutches › Casing
Issued 5 July 2004 Resolved
Place vessel in drydock to perform repairs to the satisfaction of cg inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 18 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 June 2004 Resolved
Replace retroreflective material on 54 adult and 18 children lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2004
Resolved 18 June 2004
Construction/Loadline › Structures › Door
Issued 17 June 2004 Resolved
Reweld broken watertight door frame on STBD 2 nd deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 18 March 2005
Lifesaving › Lifejacket/PFD (General)
Issued 24 May 2004 Resolved
REPAIR SEIZED PORT AFT LIFEJACKET LOCKER DOOR LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 May 2004 Resolved
REPAIR PORT AFT SEIZED PASSENGER DOOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Engineering › Steering Gear System
Issued 24 May 2004 Resolved
REPAIR PACKING GLAND ON #2 RUDDER LEGACY COMPONENT DESC: Rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Fire Fighting › Automatic Sprinkler System
Issued 24 May 2004 Resolved
PROVIDE PROOF OF PROPER OPERATION ON AIR REGULATING VALVE FOR SPRINKLER SYSTEM LEGACY COMPONENT DESC: Pressure Tank
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 May 2004 Resolved
REPAIR ALL INOPERATIVE WINDSHIELD WIPERS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 18 June 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 May 2004 Resolved
REPAIR ALL EXHAUST SYSTEM LEAKSAND REPLACE MISSING INSULATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 18 June 2004
Electrical › Electric Supply System (service)
Issued 24 May 2004 Resolved
CLEAN ALL BATTERYS AND STORAGE BOXES OF TRASH AND DEBRIS. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Electrical › Electrical Distribution System (service)
Issued 10 October 2003 Resolved
Install new electric cables to the starter of #3 main propulsion engine prior to placing into service. LEGACY COMPONENT DESC: Electric Starter Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 May 2004
Engineering › Diesel Engine (auxiliary)
Issued 10 October 2003 Resolved
Repair fuel leaks on starboard ship service generator located on fuel rack. LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Received fax from Raymon Eugene Thomas (master) that item was corrected.
Engineering › Diesel Engine (auxiliary)
Issued 10 October 2003 Resolved
Repair oil and temperture gauges for both ship service generators. LEGACY COMPONENT DESC: Gages
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Received fax form Ramond Eugene Thomas that items was repaired.
Engineering › Fuel Oil Service System
Issued 10 October 2003 Resolved
Prior to carrying passengers aline the racor fuel filters so half are open and half are closed. Provide and post diagram to show correct alinement. LEGACY COMPONENT DESC: Proper setup
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Received fax form Ramond Eugene Thomas that items was repaired.
Fire Fighting › Ventilation Systems
Issued 10 October 2003 Resolved
Provide open/close indicators for the engine room fire dampners. LEGACY COMPONENT DESC: Indicator
Condition: Design Flaw
Due 30 October 2003
Resolved 26 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 October 2003 Resolved
Repair exhaust leak on he port main propulsion engine. LEGACY COMPONENT DESC: Exhaust system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Received fax form Ramond Eugene Thomas that items was repaired.
Construction/Loadline › Hull
Issued 14 September 2003 Resolved
Submit repair proposal for fractured hull plating and fractured transverse frams IWO frame 22, the repair must be completed prior to the carriage of passengers. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2003
Resolved 20 September 2003
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 July 2003 Resolved
Install missing emergency light on port upper deck underwing and verify proper operation of all emergency lights.
Condition: Improper/Lack of Maintenance
Due 15 August 2003
Resolved 17 June 2004
Engineering › Steering Gear System
Issued 31 July 2003 Resolved
Install nut or nuts on the bolt, outbaord side of the steering ram. LEGACY COMPONENT DESC: Ram
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Cleared
Engineering › Diesel Engine (auxiliary)
Issued 31 July 2003 Resolved
Repair starboard generator exhaust leaks LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Placed in Improper Service
Due 7 August 2003
Resolved 17 October 2003
Resolution: Cleared
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 31 July 2003 Resolved
Repair fuel leaks on starboard ship service generator located on the fuel rack and on the fuel filter. LEGACY COMPONENT DESC: Nozzle, Injection (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2023
Resolution: Vessel sank in Crown Bay, St. Thomas and sustained substantial damage due to Hurricane Irma on 06 September 2017. Insurance deemed the vessel a total loss. Vessel was scrapped.
Engineering › Steering Gear System
Issued 31 July 2003 Resolved
Repair the hydraulic steering oil leak located forward port side of the engine room space. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 7 August 2003
Resolved 10 October 2003
Resolution: Cleared.
Engineering › Shafting/Propeller Arrangements
Issued 31 July 2003 Resolved
Adjust the port outboard engine shaft packing gland. LEGACY COMPONENT DESC: Stern Gland
Condition: Improper/Lack of Maintenance
Due 2 August 2003
Resolved 10 October 2003
Resolution: Cleared.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 31 July 2003 Resolved
Repair portside main diesel engine exhaust leaks LEGACY COMPONENT DESC: Exhaust
Condition: Improper/Lack of Maintenance
Due 7 August 2003
Resolved 12 June 2023
Resolution: Vessel sank in Crown Bay, St. Thomas and sustained substantial damage due to Hurricane Irma on 06 September 2017. Insurance deemed the vessel a total loss. Vessel was scrapped.
Operations/Management › Drills/Instruction
Issued 31 July 2003 Resolved
Install life raft launching instructions on the inboard side of the upper deck bulwark. LEGACY COMPONENT DESC: Launching/Recovery of Survival Craft
Condition: Improper Installation
Due 7 August 2003
Resolved 10 October 2003
Resolution: Installed.
Lifesaving › Lifejacket/PFD (General)
Issued 31 July 2003 Resolved
Post life jacket donning placards on the upper aft exterior deck. LEGACY COMPONENT DESC: Donning Placards
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Installed.
Documentation › Markings/Placards
Issued 31 July 2003 Resolved
Post "No passengers allowed" sign on ladder to upper bridge deck LEGACY COMPONENT DESC: No entry allowed
Condition: Improper/Lack of Maintenance
Due 7 August 2003
Resolved 10 October 2003
Resolution: Installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 31 July 2003 Resolved
Re-install guard on the starboard generator that was found laying on the deck just aft of the generator. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Cleared.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 31 July 2003 Resolved
Secure the forward most seat on the second deck LEGACY COMPONENT DESC: Seating
Condition: Improper/Lack of Maintenance
Due 2 August 2003
Resolved 10 October 2003
Resolution: Cleared.
Fire Fighting › Automatic Sprinkler System
Issued 31 July 2003 Resolved
Remove soft pipe coupling on the raw water intake of the sprinkler system and install hard fixed piping. This may be accomplished at the vessels next drydocking. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Navigation › Collision/Grounding Avoidance › Radar
Issued 31 July 2003 Resolved
Repair or replace the vessels RADAR. Vessel is restircted to daylight operations only while passengers are onboard. The vessel may not operate with passengers onboard between the hours of sunset and sunrise until the RADAR is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 August 2003
Resolution: Received and reviewd technitions report from CRT marine electronics. Requirement cleared and vessel is allowed to resume normal night time operations.
Personnel › Certificates/Documents/Licenses
Issued 31 July 2003 Resolved
Provide CPR/First Aid course completion records for at least 50% of the crew. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Resolution: Training Conducted, company wating for payment prior to issuing cards.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 23 April 2003 Resolved
Repair #3 Main Diesel Engine
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 18 June 2004
Fire Fighting › Ventilation Systems
Issued 23 April 2003 Resolved
Repair engine space power ventilation fans. LEGACY COMPONENT DESC: Fans
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 31 July 2003
Lifesaving › Lifebuoys
Issued 23 April 2003 Resolved
Repalce missing life float light. Prior to the carriage of passengers at night or at times of reduced visibility. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2003
Construction/Loadline › Hull
Issued 9 February 2003 Resolved
Crop and renew as original the fractured section of side shell on the portside 4 feet above the waterline just aft of the Male head compartment. Section measures approximately 30"X30". LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2003
Electrical › Electrical Distribution System (service)
Issued 9 February 2003 Resolved
Make repairs to the starboard inboard main engine starter to ensure no short or sparks occur when starter is energized. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 February 2003 Resolved
Install air filters on both intakes on the port inboard engine and ensure air filters on all engines are properly attached and secured. LEGACY COMPONENT DESC: Air Cleaner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 February 2003 Resolved
Make permanent repairs both port engines leaking exhaust system and replace any damaged exhaust lagging. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 February 2003 Resolved
Make permanent repairs to the electronic control modules on both port engines, prove proper operation of engines and make vessel available for sea trials. LEGACY COMPONENT DESC: Governor
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2003
Engineering › Generator (propulsion-electric)
Issued 9 February 2003 Resolved
Repair starboard generator guage panel and govenor
Due 11 April 2003
Resolved 12 June 2023
Resolution: Vessel sank in Crown Bay, St. Thomas and sustained substantial damage due to Hurricane Irma on 06 September 2017. Insurance deemed the vessel a total loss. Vessel was scrapped.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 February 2003 Resolved
Repair engine #4 EDM to show working pressure and temp of the reduction gear.
Due 11 April 2003
Resolved 31 July 2003
Engineering › Steering Gear System
Issued 9 February 2003 Resolved
Adjust or repack both port and starboard rudder bearings to allow only a proper amount of water. LEGACY COMPONENT DESC: Rudder Stock
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2003
Resolved 10 October 2003
Resolution: Cleared
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 February 2003 Resolved
Repair vessel exhaust alarms and verify proper function of all alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2004
Construction/Loadline › Structures
Issued 9 February 2003 Resolved
All crewmembers are reminded to verify the proper working order and keep closed at all times while underway the aft water tight door allowing acess to the engine space. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2003
Fire Fighting › Ventilation Systems
Issued 20 March 2002 Resolved
The louver closure springs on all E/R vent closures had rusted to a point where they would not close the vents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2002
Resolution: New springs were installed and verified by the attending inspector.
Communications › Internal Communications System
Issued 20 March 2002 Resolved
The vessels main passenger deck internal communications speaker were inoperative.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2002
Construction/Loadline › Hull
Issued 20 March 2002 Resolved
Provide repair proposal for steering compartment. Crop and renew aft STBD side bay approx. 36" X 36" hull plating between frames 1-5. Crop and renew longitudinals 3 & 4. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 21 April 2002
Resolved 18 July 2003
Construction/Loadline › Structures
Issued 20 March 2002 Resolved
Provide repair proposal to crop and renew longitudinal #6 in fin stabalizer compartment 2nd bay aft STBD side.
Due 21 April 2002
Resolved 18 July 2003
Construction/Loadline › Markings
Issued 20 March 2002 Resolved
Paint vessel name and hailing port with contrasting color on the stern. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 22 April 2002
Resolution: Crew painted name and home port on stern
Engineering › Thrusters
Issued 20 March 2002 Resolved
Provide repair proposal for the vessesl bnow thruster. LEGACY COMPONENT DESC: Motor
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 10 October 2003
Resolution: Witness proper operation of newley installed control system.
Construction/Loadline › Hull
Issued 20 March 2002 Resolved
Clean all bilges to reduce the amount of hull corrosion from dissimilar metal contact in saltwater solution. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 22 April 2002
Engineering › Freshwater Generation System
Issued 20 March 2002 Resolved
Isolate all copper piping from aluminum in the fin stabalizer room to prevent corrosion. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 21 April 2002
Resolved 22 April 2002
Construction/Loadline › Structures
Issued 20 March 2002 Resolved
Provide repair proposal including a design change to the cracks in the fwd doors of the main passsenger deck. LEGACY COMPONENT DESC: Superstructure
Condition: Design Flaw
Due 21 April 2002
Resolved 18 July 2003
Engineering › Steering Gear System
Issued 20 March 2002 Resolved
Adjust both rudder post paking glands LEGACY COMPONENT DESC: Rudder Stock
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 22 April 2002
Resolution: Adjusted packing.
Electrical › Electric Supply System (service) › Battery Charger
Issued 19 February 2002 Resolved
VSL MAIN PROPULSION CONTROL SYSTEM BATTERY CHARGER FAILED
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2002
Resolution: VSL OPERATOR INSTALLED NEW BATTERY CHARGERS
Electrical › Electric Generation Source (service) › Generator
Issued 29 December 2001 Resolved
Recieved a report that the vessels number 1 ship service generator was inoperatble.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 29 December 2001
Resolution: Port Authority sent a fax reporting the repair of the generator. Faxed recieved by and defiecency cleared by [name withheld], CID.
Fire Fighting
Issued 15 August 2001 Resolved
Install placarding in accordance with 46 CFR 131.899 no later than 15 SEP 01.
Condition: Unknown
Due 15 September 2001
Resolved 20 March 2002
Fire Fighting
Issued 15 August 2001 Resolved
Install indicators for all 4 dampers which indicate wheterh damper is open or closed no later4 than 15 SEP 01 in accordance with 46 CFR 131.899.
Condition: Unknown
Due 15 September 2001
Resolved 20 March 2002
Fire Fighting
Issued 15 August 2001 Resolved
Install remote manual closure mechanism outside of machinery spaces no later than 15 SEP 01 in accordance with 46 CFR 131.899.
Condition: Unknown
Due 15 September 2001
Resolved 15 August 2001
Fire Fighting
Issued 15 August 2001 Resolved
Install means on all 4 Dampers to isolate dissimilar metals from on anotherno later than 15 SEP 01.
Condition: Unknown
Due 15 September 2001
Resolved 20 March 2002
Documentation
Issued 18 May 2001 Resolved
PROVIDE AND MAINTAIN LIFESAVING MAINTANCE RECORD BOOK IN ACCORDANCE WITH 46CFR 122.702.
Condition: Unknown
Due 18 June 2001
Resolved 9 October 2001
Engineering
Issued 18 May 2001 Resolved
Clear check engine light alarms for the #2 and #4 main propulsion engines (bridge).
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Fire Fighting
Issued 18 May 2001 Resolved
Repair/replace air pressure regulator valve to sprinkler system and set system operating pressure to 50 psi for both holding tanks.
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Resolution: Retested sat
Navigation
Issued 18 May 2001 Resolved
Provide navigation publications IAW 46 CFR 122.520
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Lifesaving
Issued 18 May 2001 Resolved
Repair/replace public address system speaker in lower level mid-ships head area.
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Construction/Loadline
Issued 18 May 2001 Resolved
Repair sliding water tight door in steering flat so that it is properly operable from all location in closing. Door must remain closed while underway in accordance with the certificate of inspection.
Condition: Unknown
Due 18 May 2001
Resolved 20 March 2002
Construction/Loadline
Issued 18 May 2001 Resolved
Repair/replace the starboard aft air supply blower in the overhead in way of the starboard ship service generator.
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Construction/Loadline
Issued 18 May 2001 Resolved
Repair/replace the seals on ear and mouth pieces of the engine room sound power phone headset.
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Construction/Loadline
Issued 18 May 2001 Resolved
Install new rubber shock mounts on all main engine electronic control boxeslocated on forward part of engines.
Condition: Unknown
Due 18 June 2001
Resolved 20 March 2002
Engineering
Issued 5 April 2001 Resolved
ALL PROPULSION ENGINES, REPAIR/REPLACE COOLING WATER INJECTIOR LINE WHERE IT CONNECTS WITH THE EXHAUST PIPING, ALL ARE HOLED.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Engineering
Issued 5 April 2001 Resolved
REPLACE RUBBER EXPANSION JOINTS FOR THE TWO-(2) PORTSIDE ENGINE EXHAUST PIPES. JOINTS ARE TORN AND CUT.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Engineering
Issued 5 April 2001 Resolved
GOUGE AND RE-WELD JOINT ON THE PORT GENERATOR-SALTWATER INJECTION LINE TO THE EXHAUST SYSTEM. HOLDED._x001C_
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Engineering
Issued 5 April 2001 Resolved
REPLACE THE SPRINKLER SYSTEM AIR RECEIVER (HOLDED).
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Engineering
Issued 5 April 2001 Resolved
REPLACE MAIN ENGINE EXPANSION JOINT AFT BULKHEAD TO STEERING ROOM ON STARBOARD SIDE, INBOARD JOINT.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Construction/Loadline
Issued 5 April 2001 Resolved
REPAIR WATERTIGHT DOOR SO THAT IT WILL CLOSE. DOOR OFF ITS TRACKS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Fire Fighting
Issued 5 April 2001 Resolved
Proved proposal for installing automatic fire dampers in all supply and exhaust ventilation duct for the engine room. See MINS item #9 issued on 02APR01 for additional details.
Condition: Unknown
Due 15 August 2001
Resolved 3 October 2001
Engineering
Issued 5 April 2001 Resolved
INSTALL DOUBLE CLAMPS ON THE FLEXABLE HOSES FOR THE, PORT AND STARBOARD SIDES, WATER COOLED EXHAUST SYSTEM FOR THE SHIP SERVICE GENERATORS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Electrical
Issued 5 April 2001 Resolved
INSTALL MISSING AMP-METER FOR THE PORT SHIP SERVICE GENERATOR BATTERY CHARGER.
Condition: Unknown
Due 18 June 2001
Resolved 5 April 2001
Lifesaving
Issued 30 March 2000 Resolved
ADDRESS AND PROVIDE FOR PASSENGER EGRESS FROM VESSEL AND PROCEDURE/METHOD FOR EMBARKING LIFE RAFTS. 46 CFR 180.150
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Lifesaving
Issued 30 March 2000 Resolved
ADDRESS STOWAGE AND DISTRIBUTION OF LIFE JACKETS TO PASSENGERS. 46 CFR 180.78 On follow-up noted that life jackets are still stored in machinery passageway, unavailable to pax's and unsecured. PRPA to build suitable storage container for lifejackets nlt 12MAY00.
Condition: Unknown
Due 21 May 2000
Resolved 5 June 2000
Documentation
Issued 30 March 2000 Resolved
PRODUCE BRIDGE LOG TO DOCUMENT REQUIRED DRILLS. - 46 CFR 185.702_x001C_ *NOTE* BRIDGE & TRAINING LOG CAN BE RECORDED IN THE SAME BOOK/LOG/RECORD.
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Lifesaving
Issued 30 March 2000 Resolved
VESSEL PERSONNEL WERE UNABLE TO DEMONSTRATE/EXECUTE DRILLS AT A SATISFACTORY LEVEL. (SEE NARRATIVE FOR DETAILS) 46 CFR 185.520/524.
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Documentation
Issued 30 March 2000 Resolved
PRODUCE A TRAINING LOG BOOK IAW - 46 CFR 185.420
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Lifesaving
Issued 30 March 2000 Resolved
PRODUCE AND DEMONSTRATE "PASSENGER SAFETY ORIENTATIONS". 46 CFR 185.506
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Lifesaving
Issued 30 March 2000 Resolved
PUBLIC ADDRESS SYSTEM NOT AUDIBLE TO PASSENGER'S. 46 CFR 184.610
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Lifesaving
Issued 30 March 2000 Resolved
MAKE DOORS IN PASSENGER ACCOMADATIONS SAFE FOR PASSENGERS. NOTED DOORS TO BE FREE SWINGING WHILE UNDERWAY. 46 177.500.177.800 PROVIDE DAMPNERS OR REPAIR HOLD-BACK HOOKS.
Condition: Unknown
Due 12 April 2000
Resolved 8 May 2000
Navigation
Issued 30 March 2000 Resolved
PROVIDE GLARE SHIELD/HOOD FOR RADAR SO THAT IT IS VISIBLE/READABLE TO MASTER DURING DAYLIGHT HOURS. 46 CFR 184.404
Condition: Unknown
Due 1 April 2000
Resolved 8 May 2000
Accommodation/Occupational Safety
Issued 31 March 1999 Resolved
REPAIR ALL GOOSE NECK VENTS SCREENS AND SPACERS.
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 31 March 1999 Resolved
STOP DRILL CRACKS, GOUGE AND WELD AREA LOCATED AT FORWARD PORT AND STBD SIDE DOOR FRAMES.
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Engineering
Issued 31 March 1999 Resolved
REPLACES TWISTED CLAP, AFT END PORT INBOARD MUFFLER
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 31 March 1999 Resolved
A FAX REPORT OF THE PROPER OPERATION OF THE CONTROL AND ALARM PANEL ON THE BRIDGE FOR THE SPRINKLER SYSTEM MUST BE RECEIVED BY THE MSO PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Documentation
Issued 31 March 1999 Resolved
Provide exact language of the safety brief for each Ports Authority Ferriesshall be received by CID, MSO San Juan, not later that COB 8APR 99.
Condition: Unknown
Due 8 April 1999
Resolved 14 May 1999
Documentation
Issued 31 March 1999 Resolved
DRUG PROGRAM DOCUMENTATION FOR ALL FERRY VESSEL EMPLOYES AT FAJARADO & CATANO IS DUE AT INSPECTIONS DEPT MSO SAN JUAN NLT COB 07APR99.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Electrical
Issued 31 March 1999 Resolved
The full load test for the #1 service generator shall be completed to satisfaction of the attending inspector. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Electrical
Issued 31 March 1999 Resolved
The completed repairs of the #2 Service generator shall be demonstrated thesatisfaction the attending inspector.
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 1 December 1997 Resolved
PROVIDE TEST PROCEDURES FOR WATER SPRINKLER SYSTEM FOR REVIEW AND APPROVAL TO MSO SAN JUAN.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 8 November 1997 Resolved
PROVIDE ADDITIONAL MEANS OF CO2 WARNING SYSTEM IN ENGINE ROOM--TWO RED STROBE LIGHTS--ONE MOUNTED OVERHEAD BETWEEN NO.2 AND NO.3 MAIN ENGINES AND ONE MOUNTED OVERHEAD BY SHIP SERVICE GENERATORS WITH WARNING PLACARDS.
Condition: Unknown
Due 8 November 1997
Resolved 8 November 1997
Documentation
Issued 8 November 1997 Resolved
PROVIDE COPY OF FIXED FIRE FIGHTING INSPECTION REPORT.
Condition: Unknown
Due 6 December 1997
Resolved 21 November 1997
Lifesaving
Issued 8 November 1997 Resolved
PROVIDE GUARD TO SIGHTGLASS FOR LUBE OIL TANK IN SHIP SERVICE GENERATOR ROOM.
Condition: Unknown
Due 6 December 1997
Resolved 21 November 1997
Construction/Loadline
Issued 8 November 1997 Resolved
MAKE PERMENANT REPAIRS TO WATER TIGHT DOOR.
Condition: Unknown
Due 20 November 1997
Resolved 21 November 1997
Fire Fighting
Issued 8 November 1997 Resolved
PROVIDE TEST PROCEDURES AND TEST TO THE SATISFACTION OF COAST GUARD INSPECTOR FIXED SPRINKLER SYSTEM.
Condition: Unknown
Due 20 November 1997
Resolved 1 December 1997
Fire Fighting
Issued 8 November 1997 Resolved
ELEVATE CO2 BOTTLES OFF THE DECK.
Condition: Unknown
Due 6 December 1997
Resolved 21 November 1997
Accommodation/Occupational Safety
Issued 8 November 1997 Resolved
PROVIDE MEANS OF OPENING "EMERGENCY ESCAPE EXIT" HATCHES IN STEERING GEAR ROOM AND ENGINE ROOM FORWARD PORT SIDE.
Condition: Unknown
Due 6 December 1997
Resolved 21 November 1997
Documentation
Issued 8 November 1997 Resolved
PROVIDE AND COMMENCE LOG OF ALL SHIPBOARD DRILLS.
Condition: Unknown
Due 6 December 1997
Resolved 21 November 1997
Engineering
Issued 8 November 1997 Resolved
RECLAMP PORT INBOARD EXHAUST MUFFLER.
Condition: Unknown
Due 8 November 1997
Resolved 8 November 1997
Fire Fighting
Issued 8 November 1997 Resolved
REPAIR WATER LEAK TO FIRE PUMP.
Condition: Unknown
Due 6 December 1997
Resolved 21 November 1997
Fire Fighting
Issued 23 October 1996 Resolved
Provide means to remotely operate the fire pump as req'd by 46CFR118.300(e)prior to carrying passengers.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 23 October 1996 Resolved
Provide a rescue boat suitable to the cognizant OCMI as req'd by 46CFR117.210 prior to carrying passengers
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Documentation
Issued 23 October 1996 Resolved
Provide/post an emergency broadcast placard as req'd by 46CFR121.506.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Lifesaving
Issued 23 October 1996 Resolved
Provide/post emergency instructions as req'd by 46CFR122.510 prior to carrying passengers.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Fire Fighting
Issued 23 October 1996 Resolved
Provide/post a fire control plan as required by 46CFR116.530 prior to carrying passengers.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Lifesaving
Issued 23 October 1996 Resolved
Provide/post life jacket placards as req'd by 46CFR122.516 prior to carrying passengers.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997

Casualty record · 6

3 July 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2140149
23 January 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3669241
5 February 2010Routine · role: Involved in a Marine Casualty · activity 3676784
4 March 2010Routine · role: Involved in a Marine Casualty · activity 3781467
25 June 2010Routine · role: Involved in a Marine Casualty · activity 3851105
30 July 2010Routine · role: Involved in a Marine Casualty · activity 3865199
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record