MAURY USCG vessel records Sign in
← All vessels

PBL 3027

PBL 3027 is a 2002 tank barge. The Coast Guard has recorded 48 inspections since 2001, most recently in August 2026, along with 13 deficiencies and 2 casualty investigations between 2005 and 2011.

Records from 2001 to 2026. Most recent: inspection, 6 August 2026.

Built
2002
Last inspected
6 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-34744

Inspections, by type

…with no type recorded11
Years with a record 24 calendar years (2001–2026)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2002
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWESTWEGO, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Gross Ton
1619 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 9

Inspection history · 48

6 August 2026 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8457098
14 February 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7865736
5 June 2022 Damage Survey · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7468634
22 August 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7295010
21 August 2021 In-Service Inspection · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Drydock Exam · COI Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7293248
27 April 2020 Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6944488
27 April 2020 Administrative Inspection · SIP Inspection/Audit
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6944536
19 August 2019 SIP Initial Entry · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6788793
21 March 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6642382
15 February 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6355863
3 October 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6281519
16 September 2016 Construction Oversight · MTSA Verification · Drydock Exam · Examination of Repairs · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6004594
21 September 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5724995
20 August 2015 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5221440
20 August 2015 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5238995
14 July 2015 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5184035
29 September 2014 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4991681
10 July 2014 Periodic Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4915284
5 September 2013 MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4713205
30 August 2012 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4425959
11 November 2011 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4212609
4 August 2011 Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4104936
21 May 2010 Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3742979
1 May 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3465214
29 January 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3401906
9 May 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3197071
16 March 2008 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3165480
5 April 2007 Hull Examination · COI Inspection · MTSA Verification · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2902097
20 December 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2843522
2 November 2006 COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2811256
8 September 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2772883
31 January 2006 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2575815
3 June 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2378331
3 June 2005 Administrative Inspection · Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2381484
7 February 2005 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2287960
1 February 2005 Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2284200
29 January 2005 Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2283535
29 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2283625
1 November 2004 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2241462
23 December 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1969121
17 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966804
10 January 2003 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1727704
6 November 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1701786
8 August 2002 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1658918
4 February 2002 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1484199
25 January 2002 Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1481322
24 January 2002 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1483290
29 November 2001 Initial Construction-Excluding Oversight · Damage Survey · Hull Examination · Initial Certification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1370433

Deficiency record · 13

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2026 Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Vessel reported running aground in the Bayou Casotte Turning Basin bound for Chevron, Pascagoula. The vessel shall produce a report to the satisfaction of the OCMI detailing any damages that have occurred or demonstrating that the vessel's structure and hull remains equivalent to recognized standards. 46 CFR 32.60-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2026
Resolution: Recieved report from company confirming no damages to barge.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2024 Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. Barge sustained hull damage during allision with another barge. Vessel restricted from movement pending TPO survey.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2024
Resolved 14 February 2024
Resolution: Received TPO report; all sat
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 August 2021 Resolved
The OCMI will ensure that every tank vessel is of a structure suitable for the carriage of flammable and or combustible liquids in bulk and for the proper grade or grades of cargo the vessel carries while in service. Gauge identified pitted areas in the presence of a Coast Guard Marine Inspector. Provide gauging report once complete. 46 CFR 31.10-15 703 C
Action required: 703 - Prior to bunkering operations
Due 25 August 2021
Resolved 8 September 2021
Resolution: Gauging complete and report submitted to Coast Guard.
Deck/Cargo › Cargo Heating › General
Issued 10 July 2014 Resolved
Prior to carrying Grade "E" cargoes, prove proper operation of Thermal Fluid Heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2014
Resolution: Witnessed proper operation of the thermal fluid heater.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 November 2006 Resolved
Hinges are wasted on the stbd NO#3 and 4 wing void hatch covers and the coaming on the NO#2 is damaged. Issued CG-835 to complete repairs by 17 Mar 06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 March 2007
Resolved 20 December 2006
Resolution: Witnessed the installation of new hinges on the #2 hatch.
Deck/Cargo › Cargo Heating › General
Issued 2 November 2006 Resolved
Operation test and fail-safes for the Thermal Fluid Heater could not be completed due to the cargo that is onboard. Issued CG-835 to complete testing prior to taking a cargo onboard that requires heating.
Action required: 705 - Other - as specified
Due 17 March 2007
Resolved 20 December 2006
Resolution: Completed satisfactory test of alarms and trips on thermal fluid heater.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 3 June 2005 Resolved
Prior to any cargo operations repair or install an operating pressure gage IWO starboard header pipe to the satisfaction of local OCMI.
Condition: Damaged By Earlier Event
Due 3 June 2005
Resolved 3 June 2005
Resolution: Replaced pressure gage, send via e-mail pictures.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 1 February 2005 Resolved
Port aft timberhead has 12" fracture connecting timberhead to deck.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2005
Resolution: Welded a fracture at the forward inside corner of the foundation. Air tested and visual inspection of all repairs revealed no deficiencies
Construction/Loadline › Structures › Rake
Issued 29 January 2005 Resolved
Provide repair proposal to the [name withheld] and repair damage to port rake knuckle (2' x 3', 2' inset 10" x 1" hole) 3 1/2" above the water line prior to loading cargo or departing the port of New Orleans, LA.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 6 February 2005
Resolution: conduct examination of final repair involving renewing 4''X2'' section of the port corner wrapper and a 6''X3'' section of the rake knuckle just under corner. Air tested and visual inspection of all repairs revealed no deficiencies
Electrical › Mast
Issued 13 January 2003 Resolved
Electrical connection for mast light cracked. LEGACY COMPONENT DESC: Connection
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 January 2003
Resolved 13 January 2003
Resolution: Corrected on the spot.
Operations/Management › Pollution
Issued 13 January 2003 Resolved
5 Gallon bucket labeled "Flammable Liquid" stored in Thermal Fluid Heater space. LEGACY COMPONENT DESC: Hazardous Location Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2003
Resolved 13 January 2003
Resolution: Bucket removed to paint locker.
Construction/Loadline › Structures › Scuttle
Issued 8 August 2002 Resolved
Replace or repair hatch combing, hinge, and damage dogs on #4 starboard wing void hatch prior to loading.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2002
Resolved 9 August 2002
Construction/Loadline › Structures
Issued 25 January 2002 Resolved
After offloading cargo, make repairs in way of the starboard side bow timberhead (bitts) where damaged during breakaway. LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 February 2002
Resolved 4 February 2002
Resolution: Received Bollinger Shipyard report attesting to repairs.

Casualty record · 2

29 January 2005Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2283625
11 November 2011Routine · role: Involved in a Marine Casualty · activity 4212609
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MMI 3027 (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.