Records from 2006 to 2026. Most recent: inspection, 17 February 2026.
Inspection history · 25
17 February 2026
Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8311800
7 July 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8172608
3 February 2025
Deficiency Check · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8076492
5 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7997283
13 June 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7923124
20 March 2024
Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7882707
23 January 2024
Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7852914
6 July 2023
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7733598
14 February 2023
Deficiency Check · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7636151
5 July 2022
Re-Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7485446
7 March 2022
Deficiency Check · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7405516
6 January 2022
Periodic Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7376528
1 July 2021
Re-Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7241266
25 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6932523
15 October 2019
Administrative Inspection · Equivalency · Re-Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6832486
3 May 2019
Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6675614
7 March 2019
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6637631
20 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6544570
4 September 2018
Administrative Inspection · Annual Inspection · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6532354
12 March 2018
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6363392
27 October 2017
Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6296483
3 May 2017
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138710
27 March 2017
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112189
19 September 2016
Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6004958
29 March 2016
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828808
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 February 2026
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. Fuel filter on Emergency Diesel Generator found leaking.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 17 February 2026
Resolution: O-ring on fuel filter replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2025
Resolved
Each self propelled vessel must be provided with a power driven pump or pumps connected to the bilge main as required by table 56.50-55(a). Power bilge pumps required for vessels below 180’ and exceeding 65’: 2. Number 1 bilge pump was inoperable.
46 CFR 56.50-55
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2025
Resolution: MI witnessed sat operation of #1 bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 July 2025
Resolved
The respective piping systems installed on ships and barges must have the necessary pumps, valves, regulation valves, safety valves, relief valves, flanges, fittings, pressure gages, liquid level indicators, thermometers, etc., for safe and efficient operation of the vessel. #2 bilge pump discharge gauge broken.
46 CFR 56.01-1(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Verified install and operation of new gauge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 7 July 2025
Resolved
Each port light installed below the bulkhead deck must conform to the following requirements: (1) Each non-opening port light must be watertight. (2) Each opening port light must be constructed so that it can be secured watertight. MI observed port light with broken glass.
46 CFR 171.116(f)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 12 August 2025
Resolution: *Extended to allow operator to source replacement glass. Dead cover secured in the interim. Received satisfactory evidence of replacement of glass port light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules. MI observed fuel leak on port Main Engine.
46 CFR 58.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Verified leak secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules. Head gasket on port Main Engine leaking oil.
46 CFR 58.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 17 February 2026
Resolution: Repairs to gasket found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 July 2025
Resolved
There shall be at least two means of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. Emergency escape in forward engine room was unable to be opened from inside the engine room.
46 CFR 72.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Verified operation of escape.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2025
Resolved
Each fixture globe, lens, or diffuser must have a high strength guard or be made of high strength material. Light above workbench in engine room did not have proper guard.
46 CFR 111.75-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Verified replacement of light with proper guard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2025
Resolved
Each fire hydrant must have at least one length of firehose, a spanner wrench. Fire stations 4 and 5 missing spanner wrenches.
46 CFR 76.10-10
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Verified installation of spanner wrenches.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2025
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and name of the port required to be marked on the stern of the vessel. Upper deck lifebuoys had faded markings that require renewal, weathered line and retroreflective tape.
46 CFR 199.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Verified corrections to life rings.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 February 2025
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. MI observed a small leak on the fuel filter bowl on the prime mover of the fire pump." 46 CFR 61.20-3(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2025
Resolved 24 February 2025
Resolution: Weeping o ring replaced with new.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 February 2025
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. Vessel found with deterioration on the second deck forward port damper. 46 CFR 61.20-3(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2025
Resolution: Repairs completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2025
Resolved
Waste paper baskets shall be constructed of approved incombustible materials with solid sides and bottoms. Onboard waste receptacles found to be general plastic household type. 46 CFR 72.05-55(b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 February 2025
Resolution: New metalic waste bins provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2025
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. Port side bridge buoy found with faded name markings. 46CFR 199.70(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 March 2025
Resolution: Ring buoy re-marked.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 3 February 2025
Resolved
The owner of a vessel subject to inspection under section 3301 shall-(1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key of which access shall only be available to the individuals described in paragraph (2);(2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system;(3) record in a log book information on all access and use of the vessel's master key, including-(A) dates and times of access;(B) the room or location accessed; and (C) the name and rank of the crew member that used the master key. Vessel missing master key control policy and logs. 46 U.S.Code 3106
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 March 2025
Resolution: Operator provided key control policy.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 3 February 2025
Resolved
(d) In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. 46 U.S.Code 11101
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2025
Resolution: Signage provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2024
Resolved
At each annual inspection, the inspector must ensure that the following tests and inspections have been conducted: the fire main system must be operated, and the pressure checked at the most remote and highest outlets. The diesel prime mover for the fire pump was leaking lube oil out of a fitting at a rate of two drips per second. Operator rectified the deficiency on the spot.
46 CFR 71.25-20(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
Resolution: Crew repaired leak.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2024
Resolved
Each conductor must be protected in accordance with its current carrying capacity. Vessel has 01 electric sump pump and 01 dehumidifier permanently installed in the shaft compartment which are receiving power from an electrical outlet. Provide plan for permanent wiring installation with proper overcurrent protection to the OCMI for approval.
46 CFR 111.50-3(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 2 October 2024
Resolution: Crew installed permanent wiring connection.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 13 June 2024
Resolved
The respective piping systems installed on ships shall have the necessary pumps, valves, etc. for the safe and efficient operation of the vessel. Salt water flush piping in the engine room found holed and/or leaking in multiple areas. Repair to the satisfaction of the Marine Inspector.
46 CFR 56.01-1(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 5 September 2024
Resolution: Accepted photos of repairs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 June 2024
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Captain's national medical endorsement expired. Provide proof of current medical endorsement prior to serving onboard an inspected vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 August 2024
Resolution: Mariner provided copy of med cert.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2024
Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors must be fitted with a single screen of corrosion-resistant wire of a least 30 by 30 mesh. Emergency generator fuel tank vent screen covered in paint and restricting flow. Repair or replace screen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 27 June 2024
Resolution: Operator cleaned fuel tank vent and reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 13 June 2024
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide - "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING". The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units. Engine room missing required signage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 16 July 2024
Resolution: Accepted photo for signage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 March 2024
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deems necessary to be assured of the safety and seaworthiness of the vessel. Bilge line in void 4 near aft bulkhead had salt buildup and signs of leakage around first welded portion above the strainer. Probing of the pipe did not reveal any significant wastage, fractures, or holes. Require pumping this void during COI renewal with a Marine Inspector present inside the void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2024
Resolved 13 June 2024
Resolution: Verified operation of bilge piping with no leaks detected.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 February 2023
Resolved
Bulkheads or decks of the ‘A’ class shall be composed of steel or equivalent metal construction. In addition, they shall be so insulated with approved structural insulation. Portion of insulation in main machinery room overhead deck found missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2023
Resolved 17 April 2023
Resolution: Operator replaced insulation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 February 2023
Resolved
Radio lifesaving appliance installation and arrangements must meet the requirements of 47 CFR 80. Bridge to bridge and radio telephony certificates expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2023
Resolved 16 May 2023
Resolution: Verified presence of updated certificates
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 February 2023
Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 70.35 of this subchapter, will be considered satisfactory evidence of the structural efficiency of the vessel. Lower channels on port and starboard weatherdeck doors associated with Presidential Suite have wastage and require repair at next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2024
Resolved 7 July 2023
Resolution: Verified proper repairs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018
Resolved
SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 March 2019
Resolution: Notified master of issue and advised him to correct.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 September 2018
Resolved
Identified several stanchions on the forecastle that are wasted; replace all wasted stanchions during the next drydock (12Jun2019).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 7 March 2019
Resolution: New stanchions welded in existing spot replacing deteriorated stanchions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 September 2018
Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer. Bilge strainer is not properly attached to the bilge piping. Tightly fit bilge strainer onto bilge piping in Lazarette and Engineroom.46 CFR 56.50 (g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 7 March 2019
Resolution: Strainer was installed tightly onto bilge piping in Laz and Engineroom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2018
Resolved
Alteration of machinery and piping systems must be done under the cognizance of the OCMI and IAW the regulations in effect at the time of installation. PVC piping is installed on #1 and #1 MDE crankcase vents. Remove PVC piping and return installation to original.46 CFR 50.05-10
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 September 2018
Resolved 11 March 2019
Resolution: PVC piping removed, plastic elbows on crankcase vents replaced with stainless steel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2018
Resolved
Flexible and Gasketed Mechanical Couplings must not be used where undetected flooding or impingement of liquid on vital equipment could disable the vessel. #1 and #2 MDE Jacket Water piping contain flexible couplings. Starboard Engine Jacket water piping also contains an mechanical coupling. Fire pump suction and discharge lines contain Mechanical couplings. Remove all couplings and repair pipes to original or repair IAW 46 CFR 56. 46 CFR 56.30-35, 46 CFR 56.30-40
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 June 2019
Resolved 24 March 2019
Resolution: Pipe Mechanical Coupling repaired IAW Subchapter F. Metal stops welded onto both sides of the coupling to prevent creep.Couplings are designed for temp and pressure of systems installed.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 12 March 2018
Resolved
Obtain a Certificate of Financial Responsibility (COFR) and provide sufficient documentation to the satisfaction of the attending U.S. Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 22 March 2018
Resolution: Vessel provided satisfactory proof of current Federal COFR for the vessel to the U.S. Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 October 2017
Resolved
Provide required non-expired Aspirin in first aid kit to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 12 March 2018
Resolution: Non-expired aspirin present in medical kit at COI inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 October 2017
Resolved
Properly mark port bridge wing ring buoy with the vessel's hailing port to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 12 March 2018
Resolution: Port bridge wing ring buoy marked with vessel's hailing port when examined at COI inspection.
Lifesaving › Inflatable Liferafts › Painter
Issued 30 October 2017
Resolved
Properly secure painter to weak link on both liferafts to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 12 March 2018
Resolution: Both IBA painters were properly secured to their weak links when examined at COI inspection.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 30 October 2017
Resolved
Ensure that all fire doors properly latch after being released from the control station to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 12 March 2018
Resolution: All fire doors tested at COI inspection and all latched properly.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 October 2017
Resolved
Ensure that all vent dampers are of sufficient size to block off the air duct to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 12 March 2018
Resolution: Vent dampers examined at COI inspection and all were adjusted to sufficiently block off their respective air ducts.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Trunking
Issued 27 March 2017
Resolved
Replace gooseneck vent screen for women's head.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 3 May 2017
Resolution: Screen replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 March 2017
Resolved
Prove proper operation of navigation light panel audible alarm.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 15 May 2017
Resolution: Audible alarm now operational.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 March 2017
Resolved
Provide properly sized tool to operate remote collision bulkhead bilge suction valve.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 3 May 2017
Resolution: Corrected.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 29 March 2016
Resolved
Properly calibrate rudder angle indicator in pilothouse.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: Deficiency properly rectified.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 29 March 2016
Resolved
Properly calibrate overspeed device so that the speed cannot exceed the maximum rated speed by more than 15%.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: Deficiency properly rectified.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 March 2016
Resolved
Prove proper operation of engine room bilge alarm.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: Deficiency properly rectified.