Records from 1990 to 2026. Most recent: inspection, 4 June 2026.
Inspection history · 51
4 June 2026
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8320117
21 May 2025
DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8117898
24 October 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8024037
5 June 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7889638
22 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7694136
23 May 2022
DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7442610
19 July 2021
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7261594
2 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7220539
2 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6966417
26 December 2019
Internal Structural Exam · Damage Survey · Hull Examination · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6881897
21 May 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6691547
12 June 2018
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6504059
22 May 2017
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6149242
12 April 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6115475
16 May 2016
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5886630
3 June 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4892517
20 June 2012
Internal Structural Exam · COI Inspection · Simplified Stability Test · Deficiency Check · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4350333
17 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3682333
18 March 2009
Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428851
16 April 2008
DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185481
3 April 2008
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179132
27 March 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3022427
8 July 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2723301
14 March 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599562
1 April 2005
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290891
23 September 2004
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2192413
28 June 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2022642
27 March 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756829
28 March 2002
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494977
22 March 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445776
17 July 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 819959
21 June 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 819280
1 May 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1473444
23 March 2000
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1049021
15 April 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 791224
24 March 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 781537
17 March 1998
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786913
18 March 1997
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1098743
20 March 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374539
18 April 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 852322
21 March 1995
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407449
10 August 1994
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1174462
15 March 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1461565
15 March 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1362747
29 July 1992
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 960599
22 July 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 28998
25 June 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 954510
9 June 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 101341
31 March 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 962746
1 May 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1215211
18 June 1990
Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 905619
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 June 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Missing placard for type of life jackets on board vsl.
Action required: 10 - Deficiency Rectified
Resolved 5 June 2024
Resolution: New placards were printed and place on vsl
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2024
Resolved
All vessels
must have navigation lights in accordance with the International and Inland Navigation Rules. Stern light missing cover so it was not to manufactures specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 11 June 2024
Resolution: Light was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2022
Resolved
move bilge pump float switch so it can float free
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2022
Resolved 24 May 2022
Resolution: float has been moved, all sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 May 2022
Resolved
replace all combustible trash cans with non combustible trash cans with no openings in the sides or open
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 22 June 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2021
Resolved
Prove proper operation of the fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2021
Resolved 19 July 2021
Resolution: tested all sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 December 2019
Resolved
Crop and renew 1st transverse frame in bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2020
Resolved 19 March 2020
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 3 June 2014
Resolved
Install positive shut off valve on bilge O/B discharge line.
Due 17 June 2014
Resolved 23 June 2014
Resolution: Bilge O/B valve installed.
Lifesaving › Hand Flares › Storage
Issued 3 June 2014
Resolved
Properly stencil distress signals.
Due 17 June 2014
Resolved 23 June 2014
Resolution: Distress signal container properly stenciled.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 June 2012
Resolved
Affix vessel name on port and starboard bow.
Due 11 July 2012
Resolved 9 July 2012
Resolution: affixed name of vessel on port and bow
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 June 2012
Resolved
Provide 4" course spacing on deck rails.
Due 11 July 2012
Resolved 9 July 2012
Resolution: inserted a bar making courses 4" on deck rails.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 June 2012
Resolved
Double clamp cooling lines for engine from sea suction through entire system.
Due 11 July 2012
Resolved 9 July 2012
Resolution: Cooling lines for engine from sea suction have been double clamped.
Engineering › Bilge Water Management System › Piping
Issued 27 June 2012
Resolved
Double clamp bilge hoses.
Due 11 July 2012
Resolved 9 July 2012
Resolution: Bilge hoses double clamped
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 27 June 2012
Resolved
Seal all bulkhead penetrations in engine room.
Due 11 July 2012
Resolved 9 July 2012
Resolution: All bulkhead penetrations sealed
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2012
Resolved
Repair fractured welds in midbody as marked.
Due 11 July 2012
Resolved 9 July 2012
Resolution: Vee and welded crack in midbody.
Engineering › Bilge Water Management System › Pump
Issued 27 June 2012
Resolved
Provide portable hand bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2012
Resolution: Provided portable hand bilge pump
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 March 2009
Resolved
COD expired; current COD not on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2009
Resolution: Received faxed copy of current COD.
Engineering
Issued 21 June 2000
Resolved
PROVIDE PLANS FOR THE INSTALLATION OF NEW MAIN DIESEL ENGINE AND JET PUMP. IAW 46CFR177.202(B)(3)(i) and (c).
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 24 March 1999
Resolved
Vee and weld cracks in gunwale rub bar in way of bow access ladder._x001C_
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 24 March 1999
Resolved
Provide cover for elect. terminal block in way of stbd aft pass seat and fuel shut-offs.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 24 March 1999
Resolved
Reseal openings to engine compt. at the following locations: aft side of port fwd eng. vent scoup; gaps in engine cover joints (mainly in way of center fwd joint); under port/stbd gunwales at eng. compt. bulkhead; and atfuel tank fill penetration of the deck.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 24 March 1999
Resolved
Reweld broken stanchion support under aft bench seat, port side.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 24 March 1999
Resolved
Vee and weld cracks in bow ladder steps._x001C_
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 24 March 1999
Resolved
Remark life jacket stowage to accurately indicate location (under center aisle floor boards) and count.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 18 March 1997
Resolved
PROVIDE FIRST AID KIT MEETING OR EQUIVALENT TO 46 CFR 160.041.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Fire Fighting
Issued 18 March 1997
Resolved
PROVE PROPER OPERATION OF "CHARGED" LIGHT INDICATOR FOR FIREBOY EXTINGUISHER.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Engineering
Issued 18 March 1997
Resolved
PROVIDE DRIP PANS FITTED WITH 30 X 30 MESH FLAME SCREEN FOR EACH FUEL FILTER.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 18 March 1997
Resolved
PROVIDE NEW RING BUOY (CG APPROVED).
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Documentation
Issued 21 March 1995
Resolved
PROVIDE PROOF CURRENT ENROLLMENT IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Engineering
Issued 31 March 1992
Resolved
PROVIDE BLOWER INTERLOCK SO THAT THE ENGINES DON'T START UNLESS BLOWERS ARERUNNING.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 31 March 1992
Resolved
PROVIDE INTAKE AND EXHAUST DUCTING FOR ENGINE COMPARTMENT THAT IS FIRE PROOF.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 31 March 1992
Resolved
PROVIDE FUEL SHUTOFF VALVES AT THE FUEL TANK AND MAKE THEM OPERABLE FROM OUTSIDE THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992