Records from 1999 to 2026. Most recent: inspection, 10 March 2026.
Documentation record
Registered dimensions (L × B × D)44.0 ft × 14.0 ft × 5.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARL BLOODWORTH BLDR · CLARKSTON, WA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portCLARKSTON, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 36
10 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8320170
25 March 2025
DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8099697
21 March 2024
Hull Examination · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7875196
29 March 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7680250
14 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7485934
16 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7153553
18 February 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6917547
25 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6718028
19 March 2019
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6643433
5 March 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6361934
7 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097878
14 November 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6041115
8 March 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5825498
4 September 2015
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5234833
4 March 2014
Hull Examination · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4804905
23 January 2012
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4230043
1 September 2011
Deficiency Check · In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4132261
17 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3682312
18 February 2010
Deficiency Check · Administrative Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3681862
18 March 2009
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428778
16 April 2008
DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185800
12 March 2008
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3170442
27 March 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3022459
8 July 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2723301
14 March 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599553
1 April 2005
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290905
30 March 2004
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2022726
27 March 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756838
28 March 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494980
13 April 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1061757
22 March 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445775
25 September 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 822829
28 July 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1052884
7 July 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1408561
28 October 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 798019
17 August 1999
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402930
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 March 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel was missing 01 2-A fire extinguisher. Vessel must provide proof of receipt and installation on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 23 March 2026
Resolution: Received photo of proper extinguisher on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2026
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel had 02 missing vent closures. Vessel Owner must provide proof of additional vent closures and demonstrate their functionality.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 23 March 2026
Resolution: Received photos of vent covers onboard an in place on vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2025
Resolved
Vessel had alcohol test strips on board but did not have alcohol test strips that were currently listed on the Conforming Products List (CPL) titled “Modal Specifications for Devices To Measure Breath Alcohol” published by the NHTSA.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 13 May 2025
Resolution: Test strips placed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2019
Resolved
Renew 02 raw water intake pipes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2019
Resolved 25 April 2019
Resolution: Marine Inspector attended vessel and witnessed newly installed raw water intake pipes.
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 March 2017
Resolved
DC01 - Replace worn port side hose which runs from pump to steering valve, to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2017
Resolved 5 March 2018
Resolution: Witnesses proper installation of new hose.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2011
Resolved
Make water light operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2011
Resolved 14 September 2011
Resolution: Received e-mail from owner stating that the light had been replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 September 2011
Resolved
Have all portable fire extinguishers serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2011
Resolved 14 September 2011
Resolution: received service report from owner.
Electrical › Electric Supply System (service) › Cable
Issued 17 March 2010
Resolved
Install bonding wire from hull to the seat box with the 110v inverter. Wire should be at least 10ga.
Action required: 705 - Other - as specified
Due 17 April 2010
Resolved 10 May 2010
Resolution: Received fax from owner stating that the bonding wire had been installed from the inverter to the hull.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2010
Resolved
Renew expired iodine in the first aid kit and add eye wash solution.
Action required: 705 - Other - as specified
Due 17 April 2010
Resolved 10 May 2010
Resolution: Received fax from owner stating that the iodine in the first aid kit was renewed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 March 2009
Resolved
Current Certificate of Documentation has expired.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2009
Resolved 2 April 2009
Resolution: Faxed copy of current COD
Electrical › Electric Generation Source (service) › Generator
Issued 18 March 2009
Resolved
Conduct plan review for recently installed 110v inverter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2009
Resolved 18 May 2009
Resolution: Conducted plan review of installation, sat
Electrical
Issued 22 March 2001
Resolved
PROVIDE 2 PORTABLE LIGHTS.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Engineering
Issued 22 March 2001
Resolved
MOVE EMERGENCY FUEL CUT-OUT PLACARD SO THAT IT CAN EASILY BE SEEN.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Lifesaving
Issued 22 March 2001
Resolved
PROVIDE RETRO TAPE ON RING BUOY.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Construction/Loadline
Issued 7 July 2000
Resolved
Provide plans for approval to repair damaged area and fractured weld at thetransom, stbd-side of the keel in the engine room bilge. 46 CFR 176.700
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Lifesaving
Issued 7 July 2000
Resolved
Update emergency checkoff list for area of operation and procedures. 46 CFR185.510 & 185.512
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 17 August 1999
Resolved
PROVIDE GASKET FOR FUEL FILL.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
ENSURE HULL PROPERLY MARKED.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Fire Fighting
Issued 17 August 1999
Resolved
PROVIDE ONE FIRE BUCKET IN LIEU OF REQUIREMENT FOR FIXED FIRE PUMP.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE PROPER LIFEJACKET DONNING PLACARD WHICH CORRESPONDS TO STYLE JACKETON BOARD.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999