Records from 2016 to 2021. Most recent: inspection, 3 February 2021.
Inspection history · 9
3 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7135435
14 February 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6908393
22 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6647009
15 March 2019
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6643215
27 June 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6457000
14 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6266340
8 May 2017
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6141584
22 September 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6005747
20 July 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5947194
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 February 2020
Resolved
Fire monitor must produce a minimum of 500 gallons per minute for standby service. Vessel’s fire monitor pump is inoperable. Must prove operation of fire monitor to the satisfaction of the attending marine inspector in order for the vessel to conduct standby vessel operations.
Reference: 33 CFR 143.405
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 February 2020
Resolution: Witness the fire monitor operate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 February 2020
Resolved
Watertight closures need to be operable. Two watertight closures would not close properly. Vessel owner must show proof that the doors properly close.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2020
Resolution: Witness operation of the watertight doors satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 February 2020
Resolved
Vessel must show operation and closure of all weathertight closures. Bow hatch and bridge door did not seal properly. Vessel representative must show that both closes properly seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 February 2020
Resolution: Vessel representative installed new gaskets for both bridge door and bow hatch.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 22 March 2019
Resolved
AIS transmits incorrect vessel information. Owner shall correct AIS profile transmission to match correct flag state and vessel particulars.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 4 April 2019
Resolution: Owner provided service report for AIS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 March 2019
Resolved
Two (02) defective gauges on pressure vessels. Replace pressure vessel gauges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 22 March 2019
Resolution: Owner replaced gauges
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 March 2019
Resolved
Worn and split nonmetallic flexible piping on #4 MDE raw water suction. Replace with satisfactory piping installation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 22 March 2019
Resolution: Owner replaced defective piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 March 2019
Resolved
Leak on #2 MDE crankcase cover. Replace gasket for cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 29 March 2019
Resolution: Owner provided technician servicing report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2019
Resolved
Exhaust leak on #1 generator. Owner shall provide evidence of satisfactory repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 29 March 2019
Resolution: Owner provided technician servicing report
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 March 2019
Resolved
Inoperable eductor on starboard fire hose. Owner shall replace eductor and provide evidence of satisfactory operation on fire hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 22 March 2019
Resolution: Owner replaced eductor and provided evidence of operation
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2019
Resolved
Vessel missing hailing port and vessel name on stern. Owner shall provide permanent markings on the stern for the above items.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 4 April 2019
Resolution: Owner provided evidence of hailing port and vessel name on stern
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 22 September 2016
Resolved
Vessel's emergency lighting was insufficient to properly light all below deck spaces at darken ship. OCMI authorized temporary battle latern use until a permanent arrangment is completed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 22 September 2016
Resolution: Vessel corrected voltage output to emgergency lighting. All emergency lighting is sufficient to light the spaces in the event of as loss of power.
Engineering › Bilge Water Management System › Strainer
Issued 22 September 2016
Resolved
Bilge suction line in steering pace does not have a strainer. The line must be fitted with a of the appropriate size.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 22 September 2016
Resolution: An appropriate strainer was welded to the bilge suction line in accordance with 46 CFR 170.120.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 22 September 2016
Resolved
Vessel had 1 1/2 foot of water in the bow void. Dewater the space and follow instructions on the stability letter for maintaining dry compartment spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Space was dewatered and crew was informed about stability letter requirements for keeping spaces free of water.