Records from 1991 to 2020. Most recent: inspection, 8 December 2020.
Inspection history · 50
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108407
3 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6332006
9 November 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6038068
3 November 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5756580
21 October 2015
Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5751259
27 July 2012
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4395771
24 July 2012
Permit to Proceed · Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4390193
24 July 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4395446
4 January 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4218189
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200376
2 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3688424
16 October 2008
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3354003
20 June 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3245795
10 August 2006
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2742945
2 August 2006
COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2733834
16 August 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2464630
21 July 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2434730
22 September 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2202827
3 March 2004
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2017036
2 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2039436
20 August 2003
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1881673
20 November 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1708568
5 November 2002
Administrative Inspection · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1701644
6 August 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465053
23 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069286
10 February 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 87689
10 February 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 229923
2 October 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1393531
5 August 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433519
5 August 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468975
8 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381355
10 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777424
21 August 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447742
23 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765143
9 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764530
16 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 202952
16 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 202954
14 August 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1402300
8 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085008
8 August 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448679
2 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867213
26 July 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444870
9 November 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1132911
1 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 27447
1 October 1993
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439441
5 August 1993
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425347
9 March 1993
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 836532
11 August 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266592
8 October 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936417
15 August 1991
Initial Certification · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936418
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 3 November 2015
Resolved
Forward port ventilation closure missing retaining pin.
Action required: 705 - Other - as specified
Due 10 November 2015
Resolved 4 November 2015
Resolution: Received picture from vessel rep clearing def.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 November 2015
Resolved
Relabel remote fuel shutoff on aft deck.
Action required: 705 - Other - as specified
Due 10 November 2015
Resolved 4 November 2015
Resolution: Received picture from vessel rep clearing def.
Construction/Loadline › Hull › Side Shell
Issued 3 November 2015
Resolved
Repair pinhole in stardboard side shell in machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2015
Resolution: Received picture from vessel rep clearing def.
Engineering › Bilge Water Management System › Not Operational
Issued 24 July 2012
Resolved
Currently, the vessel's installed bilge system is not capable of taking suction from the spaces forward of the engine room. Vessel is required to prove the proper operation of the installed bilge system prior to departure from port.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2012
Resolved 26 July 2012
Resolution: Tested installed bilge system in all spaces, with the exception of the forepeak; tests were satisfactory. (Didn''t test the installed system in the forepeak due to the damage caused by the grounding.)
Engineering › Steering Gear System › Power Unit
Issued 24 July 2012
Resolved
Vessel reportedly grounded due to a failure in the steering gear system; the vessel's steering gear motor tripped the 208 volt breaker in the engine room, resulting in the rudder remaining hard-over to port. Vessel is required to prove the proper operation of the steering system prior to its departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2012
Resolved 26 July 2012
Resolution: Marine electrician performed a load analysis on the steering system after finding a loose wire underneath the console in the pilothouse. The steering system tested satisfactorily.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 July 2012
Resolved
Prove proper operation of bilge high-level alarms in each compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2012
Resolved 26 July 2012
Resolution: Tested all bilge high-level alarms throughout the vessel; both audible and visual indicators tested satisfactorily.
Stability › Watertight Integrity › General
Issued 16 October 2008
Resolved
Penetration through E/R watertight bulkhead is not properly fitted with a collar and is not watertight.
Action required: 705 - Other - as specified
Due 2 November 2009
Resolved 14 November 2011
Resolution: Penetrations plugged and is watertight.
Construction/Loadline › Hull
Issued 5 November 2002
Resolved
Repair cracks to port and starboard corner brackets at the knees. LEGACY COMPONENT DESC: Longitudinal Frame
Due 8 November 2002
Resolved 5 November 2002
Resolution: Welded by third party.
Documentation
Issued 6 August 2001
Resolved
Submit the Cert. of Documentation to reflect the correct owners address.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Navigation
Issued 26 July 1994
Resolved
REPAIR/REPLACE/RENEW SINGLE SIDEBAND RADIO AND PROVE PROPER OPERATION TO A MARINE INSPECTOR.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Construction/Loadline
Issued 1 October 1993
Resolved
MAKE PERMANENT REPAIRS TO PORT SIDE BULWARK STRUCTURAL MEMBERS AND RAIL IN WAY OF FORWARD BULKHEAD OF HOUSE.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Documentation
Issued 15 August 1991
Resolved
PROVIDE ON BOARD VALID FCC RADIO TELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 23 October 1991
Resolved 23 October 1991