MAURY USCG vessel records Sign in
← All vessels

HERCULES 253

HERCULES 253 is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 101 inspections since 1982, most recently in October 2014, along with 106 deficiencies and 2 casualty investigations between 2004 and 2007.

Records from 1982 to 2014. Most recent: inspection, 27 October 2014.

Built
1982
Last inspected
27 October 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8755546 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-54245

Inspections, by type

…with no type recorded23
Years with a record 31 calendar years (1982–2014)
The 101 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3801 - Regulatory (Subpart C or D), Gross Ton
6071 - Convention (Subpart B), Gross Ton
3801 - Regulatory (Subpart C or D), Net Ton
1821 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DELTA POWER Towing Vessel · MISLE 145407 · 29 January 2007 · activity 2867685GIS-BLAKELY Passenger (Inspected) · MISLE 361382 · 10 February 2001 · activity 87689

Inspection history · 101

27 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5012808
16 October 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5006389
8 August 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4948439
23 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4897056
7 June 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4336787
15 May 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4312252
1 December 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4199294
12 September 2011 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4089439
23 February 2011 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3951152
14 September 2010 Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3849210
14 December 2009 COC-MODU Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3650705
11 March 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3431479
8 March 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3429574
13 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3362530
23 October 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3350351
11 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3295390
21 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3275638
13 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3235739
26 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3171818
25 January 2008 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3136377
18 May 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2933940
9 March 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2884858
29 January 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2867685
24 October 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2801812
5 January 2006 COC-MODU Annual
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2561566
28 October 2004 COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2229924
23 July 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2241821
19 December 2003 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1967008
21 April 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1777730
27 October 2002 Deficiency Check · Certificate of Compliance
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1696629
24 June 2002 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1635510
24 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1480972
19 November 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397779
24 August 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 687668
28 June 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 176989
10 February 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 87689
3 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049343
9 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815824
7 February 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1045900
10 January 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811949
4 January 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 811716
13 December 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811654
2 December 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1402999
23 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1114881
5 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127708
6 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136731
4 December 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472862
30 September 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801602
23 June 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127577
28 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791522
10 December 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427435
30 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781939
22 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111563
26 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784706
6 May 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097981
10 February 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104236
3 February 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1102212
3 January 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430335
16 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088878
1 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086135
29 February 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380422
3 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385611
8 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 879069
9 January 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429989
11 January 1994 Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373965
14 January 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 839854
14 January 1993 Deficiency Check · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1154871
28 October 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 829318
26 June 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 958005
29 April 1992 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1259958
21 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448393
30 December 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270230
25 November 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263812
15 October 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251668
10 December 1990 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1240577
19 October 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 912090
30 November 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 907045
17 October 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 930011
13 October 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1194817
30 September 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1348616
16 May 1989 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352906
7 December 1988 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 897586
21 October 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1207004
12 November 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022269
9 October 1987 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1322068
22 April 1987 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1005660
6 April 1987 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020896
6 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315223
8 December 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025757
7 November 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332277
10 October 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1011210
13 December 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 991713
8 November 1985 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 992188
3 October 1985 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 987578
6 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1291320
11 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978172
4 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288579
27 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272273
29 September 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968534
23 March 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966282
8 October 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271198

Deficiency record · 106

Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 September 2010 Resolved
Ensure there is sufficient emergency "E" lighting in upper stair tower to control room.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 20 September 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 September 2010 Resolved
Ensure escape route in lower living quarters is properly marked and readable during emergencies.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 4 October 2010
Accommodation/Occupational Safety › Potable Water System › General
Issued 14 September 2010 Resolved
Ensure that potable water pump suction and discharge flexible piping is certified for potable water by N.S.F.-P.W.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 4 October 2010
Engineering › Pressure Vessel › Marking and Stamping
Issued 14 September 2010 Resolved
Provide pressure vessel inspection documentation indicating internal inspection within 5 years.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 20 September 2010
Engineering › Fuel Oil Service System › Filter
Issued 14 September 2010 Resolved
Remove or provide a permanent install for Tacor filters for F/O day tank to F/O purifier.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 20 September 2010
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 14 September 2010 Resolved
Mark F/O transfer hoses IAW 33 CFR 154.500.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 21 September 2010
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 September 2010 Resolved
Port sack room storage hatch is incapable of being watertight. Repair or renew hatch to the satisfaction of vessel's class society.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 20 September 2010
Lifesaving › Buoyant Smoke Signals › General
Issued 23 October 2008 Resolved
Replace expired smoke buoy on port side lifeboat deck to the satisfaction of class.
Due 14 November 2008
Resolved 17 November 2008
Resolution: Replaced expired smoke buoy on port side lifeboat deck.
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 23 October 2008 Resolved
Replace (2) expired smoke canistors in port life boat to the satisfaction of class.
Due 14 November 2008
Resolved 17 November 2008
Resolution: Replaced the expired smoke canistors in the port life boat.
Fire Fighting › Miscellaneous Items › Helicopter Decks
Issued 23 October 2008 Resolved
Provide 4 foot applicator for STBD # 3 heliport fire fighting station. Complete to the satisfaction of class.
Due 14 November 2008
Resolved 17 November 2008
Resolution: Provided 4 foot applicator for STBD # 3 heliport fire fighting station.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 23 October 2008 Resolved
Provide a copy of approved fire control plan by Flag State to reflect new additions such as portable quarters and changes to lifesaving appliances.
Due 1 December 2008
Resolved 19 November 2008
Resolution: The portable quarters were removed and are no longer in violation of the fire control plan.
Construction/Loadline › Structures › Door
Issued 23 October 2008 Resolved
Wasted bottom flange on forward stbd mud pump room door. Repair to the satisfaction of class.
Due 1 December 2008
Resolved 19 November 2008
Resolution: Replaced the gasket in the forward stbd mud pump room door. Witnessed satisfactory chalk test to repair.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 23 October 2008 Resolved
Temporarily repair fire alarm system in portable quarters prior to use. Permanently repair system to the satisfaction of class by 01 DEC 08.
Due 1 December 2008
Resolved 19 November 2008
Resolution: They removed the portable quarters, no fire alarm system needed anymore.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 January 2008 Resolved
Door in Mud Pit room required to be Class A, Class B currently installed.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 21 July 2008
Resolution: Mud pit door replaced and cleared by ABS. MSU Port Arthur. //s// [name withheld]
Fire Fighting › Structural - A Class Divisions › Doors
Issued 28 January 2008 Resolved
Fire doors in Mud Pit room did not self close as required by approved Fire Control Plan.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 11 March 2008
Resolution: Completed, A. Willett
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 January 2008 Resolved
Number and location of Smoke detectors do not match Fire Control plan.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 11 March 2008
Resolution: Completed, A. Willett
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 28 January 2008 Resolved
Number and location of Stokes litter did not match Fire Control Plan.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 11 March 2008
Resolution: Completed, A. Willett
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 January 2008 Resolved
Junction box in Mud Pit room did not meet Class I Div 1 standards as required by Hazardous Location Plan.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 11 March 2008
Resolution: Completed, A. Willett
Lifesaving › Lifeboat Equipment › Radar Reflector
Issued 28 January 2008 Resolved
Liferafts number 1 and 2 did not have required radar reflector.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 11 March 2008
Resolution: Completed, A. Willett
Fire Fighting › Fire Pumps › Pressure
Issued 5 January 2006 Resolved
Prove proper operation of the #2 Fire pump
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2006
Resolution: [name withheld] verified proper pump operation
Lifesaving › Lifeboat › Capacity
Issued 27 December 2005 Resolved
Install starboard lifeboat or maintain a standby vessel prior to operation
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2006
Lifesaving › Inflatable Liferafts › Painter
Issued 27 December 2005 Resolved
Provide proper float free liferaft for of installed height
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2005
Operations/Management › Drills/Instruction › Fire
Issued 1 November 2002 Resolved
ONCE PROPERLY MANNED, CONDUCT FIRE AND ABANDON DRILLS.
Action required: 705 - Other - as specified
Resolved 26 October 2004
Resolution: Rig presented documentation showing that the required drills had been conducted, also, USCG witnessed drills during annual exam.
Electrical
Issued 1 November 2002 Resolved
PROVE PROPER OPERATION OF THE STAND BY GENERATOR.
Due 2 January 2003
Resolved 10 November 2002
Resolution: RECEIVED CONFIRMATION FROM OIM THAT DEFICIENCY WAS RECTIFIED.
Lifesaving
Issued 19 November 2001 Resolved
Prior to unit returning to operation conduct both fire and boat drills withfull crew in the presence of a CG Marine Inspector.
Condition: Unknown
Due 19 November 2002
Resolved 21 May 2002
Lifesaving
Issued 2 December 1999 Resolved
Replace limit switch on port lifeboat and ensure operation.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Accommodation/Occupational Safety
Issued 2 December 1999 Resolved
Replace Vent clousure at Number 1 engine room supply vent for number 2 & 3 engine room.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Accommodation/Occupational Safety
Issued 2 December 1999 Resolved
Mare repairs to red fox marine sanitation system, hole located aft port side to be inserted back to good metal.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Electrical
Issued 2 December 1999 Resolved
Repair hole in battery box for obstruction lights and install lead liner.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 4 December 1998 Resolved
RENEW FUEL OIL SUPPLY AND RETURN LINES ON ALL THREE MAIN GENERATOR PRIME MOVERS. ROUTE LINES IN SUCH A MANNER SO THAT THEY WON'T CHAFE.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Electrical
Issued 4 December 1998 Resolved
REPAIR, CONDUCT SATISFACTORY TEST, AND LOG, THE STARTING AND RUNNING OF THEEMERGENCY GENERATOR IN THE AUTOMATIC MODE.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Electrical
Issued 4 December 1998 Resolved
CONDUCT SATISFACTORY TEST AND LOG THE TOTAL RIG EMERGENCY SHUT-DOWN. CONDUCT TEST FROM BOTH LOCATIONS (OIM'S OFFICE AND DRILL FLOOR).
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Lifesaving
Issued 10 December 1997 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASING GEAR UNDER LOAD OF 1.1 TIMESTOTAL MASS OF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONNEL AND EQUIPMENT IN ACCORDANCE WITH 46 CFR 109.301 (h)(5).
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Unknown
Issued 10 December 1997 Resolved
IMPLEMENT POLICY TO TRAIN CREW AND INDUSTRIAL PERSONEL IN FIRE FIGHTING, LIFESAVING, AND WATER SURVIVAL IN ACCORDANCE WITH 46 CFR 109.213.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Documentation
Issued 10 December 1997 Resolved
IMPLEMENT POLICY TO MAINTAIN RECORDS OF TRAINING AND DRILLS IN ACCORDANCE WITH 46 CFR 109.213.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Deck/Cargo
Issued 10 December 1997 Resolved
CONDUCT ANNUAL CRANE SURVEY.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Fire Fighting
Issued 10 December 1997 Resolved
RENEW WASTED FIREMAIN PIPING AT FIRE STA NO. 4.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Documentation
Issued 10 December 1997 Resolved
PROVIDE TRAINING MATERIALS ON BOARD IN ACCORDANCE WITH 46 CFR 109.213.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Lifesaving
Issued 10 December 1997 Resolved
RENEW HAND RAILS AROUND WINCH BRAKE PLATFORM, LIFEBOAT #2.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Unknown
Issued 10 December 1997 Resolved
IMPLEMENT POLICY TO TRAIN NEW PERSONNEL WITHIN TWO WEEKS OF REPORTING ON BOARD IN ACCORDANCE WITH 46 CFR 109.213(g).
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Unknown
Issued 3 January 1997 Resolved
BENCH TEST RELIEF VAVLE ON AIR RECIEVER UNDER DRILL FLOOR.
Condition: Unknown
Due 3 January 1997
Resolved 3 January 1997
Lifesaving
Issued 3 January 1997 Resolved
PUT REFLECTIVE TAPE ON ALL LIFE RINGS.
Condition: Unknown
Due 3 January 1997
Resolved 3 January 1997
Unknown
Issued 3 January 1997 Resolved
PROVIDE DOCUMENTATION ABS HAS CONDUCTED INTERNAL INSPECTION OF ALL PRESSUREVESSEL OR MAKE SAME AVAILABLE FOR MARINE INSPECTOR.
Condition: Unknown
Due 3 January 1997
Resolved 3 January 1997
Accommodation/Occupational Safety
Issued 3 January 1997 Resolved
SERVICE GALLEY FIRE HOOD PER SAFETY CONCEPT INSPECTION REPORT, 19SEP96.
Condition: Unknown
Due 3 January 1997
Resolved 3 January 1997
Accommodation/Occupational Safety
Issued 3 January 1996 Resolved
MAKE REPAIRS TO DOORS TO MUDPIT ROOM AND ENSURE THEY ARE GASTIGHT AND SELF-CLOSING AS REQUIRED BY 46 CFR 108.175.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Fire Fighting
Issued 3 January 1996 Resolved
CONDUCT FUNCTIONAL TEST OF CO2 FIRE EXTINGUISHING SYSTEM WHICH WAS NOT CONDUCTED DURING ANNUAL SERVICING ON 13OCT95.
Condition: Unknown
Due 8 January 1996
Resolved 8 January 1996
Engineering
Issued 9 January 1995 Resolved
REPAIR AND PROVE PROPER OPERATION OF LOW LUBE OIL PRESSURE ALARM ON GEN #3
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 9 January 1995 Resolved
REPAIR AS NECESSARY AND PROVE PROPER OPERATION OF BOTH BILGE PUMPS.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 9 January 1995 Resolved
REPOSITION OBSTRUCTION LIGHTS TO BE ON THE SAME HORIZONTAL PLANE.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 9 January 1995 Resolved
ADJUST MAIN DECK WATER TIGHT DOORS AS NEEDED.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Electrical
Issued 9 January 1995 Resolved
PROVE PROPER OPERATION OF MUD LOGGER VIDEO MONITOR ON DRILL FLOOR.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Electrical
Issued 9 January 1995 Resolved
PROVE PROPER OPERATION OF PURGE FAILURE LIGHT AND PROVIDE AUDIBLE ALARM FOR480V BREAKER BOXES ON DRILL FLOOR.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Accommodation/Occupational Safety
Issued 9 January 1995 Resolved
PROVIDE FLAG STATE ACCEPTENCE OF PITTING ON #2 CEMENT TANK (16500).
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Lifesaving
Issued 11 January 1994 Resolved
MAKE ALL GENERAL ALARM BELLS AVAILABLE FOR TESTING.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Construction/Loadline
Issued 11 January 1994 Resolved
ADJUST ALL WATERTIGHT DOORS AS NEEDED.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Electrical
Issued 11 January 1994 Resolved
MAKE VENTILATION AND TOTAL RIG SHUTDOWN AVAILABLE FOR TESTING AND INSPECT E-LIGHTS.
Condition: Unknown
Due 26 February 1994
Resolved 18 February 1994
Electrical
Issued 28 October 1992 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR REMOTE SHUTDOWN TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Construction/Loadline
Issued 29 April 1992 Resolved
REPAIR OR RENEW LEAKING MAIN SEA SUCTION SEA VALVE PRIOR TO PUTTING BARGE IN WATER.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Lifesaving
Issued 30 December 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Fire Fighting
Issued 30 December 1991 Resolved
OBTAIN INTERNATIONAL SHORE CONNECTION IN ACCORDANCE WITH FIRE CONTROL PLAN.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Fire Fighting
Issued 30 December 1991 Resolved
CORRENT FIRE STATIONS #3, #4 SO APPLICATORS WILL FIT PROPERLY IN NOZZLES.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Fire Fighting
Issued 30 December 1991 Resolved
FIX FIRE NOZZLES' TIP AND TIP SECURING MECHANISMS AT FIRE STATION #7, #8, #11.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Fire Fighting
Issued 30 December 1991 Resolved
REPLACE NON-CG APPROVED FIRE NOZZLES WITH CG APPROVED NOZZLES.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Engineering
Issued 30 December 1991 Resolved
TEST TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Lifesaving
Issued 30 December 1991 Resolved
TEST EMERGENCY GENERATOR SHUTDOWN, ESSENTIAL ELECTRICAL EQUIPMENT SHUTDOWN (RIG FLOOR).
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Lifesaving
Issued 30 December 1991 Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS - TOOL PUSHER'S OFFICE, LOWER LEVEL HEAD, BOTH BELLS IN MUD PIT.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Lifesaving
Issued 30 December 1991 Resolved
RECHARGE AIR BOTTLES IN LIFEBOAT #1.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Electrical
Issued 30 December 1991 Resolved
REPAIR EMERGENCY LIGHT IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Engineering
Issued 30 December 1991 Resolved
INSTALL FUEL FILTER FLAME SHIELD ON EMERGENCY GENERATOR.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Lifesaving
Issued 30 December 1991 Resolved
TEST DRAW WORKS BLOWER FAILURE ALARM.
Condition: Unknown
Due 30 December 1991
Resolved 30 December 1991
Unknown
Issued 19 October 1990 Resolved
REPAIR PURGE ALARM LIGHT ON DRILLER'S CONSOLE.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Fire Fighting
Issued 19 October 1990 Resolved
REPAIR OR REPLACE FIRE PUMP PACKING.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Engineering
Issued 19 October 1990 Resolved
INSTALL GUARDS OVER LUBE OIL TANK SIGHT GAUGES IN BULK TANK ROOM.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Construction/Loadline
Issued 19 October 1990 Resolved
PROPERLY ADJUST WATER TIGHT DOORS #10, 21 & 22.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Lifesaving
Issued 19 October 1990 Resolved
HAVE TWO (2) OF THE FOUR (4) SCBA CYLINDERS HYDROSTATICALLY TESTED.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Lifesaving
Issued 19 October 1990 Resolved
LOWER TO THE WATER, RELEASE AND OPERATE BOTH LIFE CAPSULES AND PROVE PROPEROPERATION OF SPRAY SYSTEM.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Construction/Loadline
Issued 16 May 1989 Resolved
PRESENT FOR COAST GUARD INSPECTION THE STARBOARD MAT TOP, MOON POOL AND KEYWAY AND THE MAT BOTTOM & SKIRT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 9 October 1987 Resolved
REPAIR OR REPLACE GLASS WINDOW IN LIFE CAPSULE #1 IN FRONT OF COXSWAINS SEAT.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Construction/Loadline
Issued 9 October 1987 Resolved
REPAIR OR REPLACE ADJUSTING NUT FOR WATERTIGHT DOOR #9. ALSO REPAIR OR REPLACE THE WASTED BOTTOM PORTION DOOR SEAL TO #9 WATERTIGHT DOOR.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Lifesaving
Issued 9 October 1987 Resolved
REPLACE 7 RING BUOYS DUE TO DAMAGED OUTER COATING THAT PROTECTS AGAINST PENETRATION OF WATER. REPLACE NON-BOUYANT LINE ON THE RING BOUY ON THE PORT SIDE WITH A BOUYANT LINE.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Lifesaving
Issued 9 October 1987 Resolved
REPLACE LIGHT COVER ON THE WATER LIGHT ATTACHED TO THE STARBOARD SIDE RING BUOY.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Lifesaving
Issued 9 October 1987 Resolved
REPLACE ONE BOATHOOK MISSING IN THE STARBOARD SIDE WHITTAKER CAPSULE.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Fire Fighting
Issued 9 October 1987 Resolved
SERVICE FIXED CO2 FIRE EXTINGUSHING SYSTEM FOR THE GENERATOR MUD PUMP COMPARTMENT.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Construction/Loadline
Issued 22 April 1987 Resolved
CONDUCT A SCAN OF THE BOTTOM OF THE SUPPORT MAT DURING THE NEXT RIG MOVE, BUT IN NO CASE LATER THAN 21 OCTOBER 1987.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Fire Fighting
Issued 7 November 1986 Resolved
THE PORTABLE CO2 FIRE EXTINGUISHERS THAT HAVE NOT BEEN HYDRO TESTED WITHIN THE LAST 5 YEARS MUST BE TESTED. THERE ARE THIRTEEN SUCH EXTINGUISHERS ON BOARD. 49 CFR 179.
Condition: Unknown
Due 7 November 1986
Resolved 7 November 1986
Unknown
Issued 10 October 1986 Resolved
CONDUCT THE ANNUAL FUEL CHANGE FOR THE #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Unknown
Issued 10 October 1986 Resolved
CONDUCT WEIGHT TESTS ON THE #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Unknown
Issued 10 October 1986 Resolved
PROVIDE EMERGENCY LIGHTING BATTLE LANTERNS WITH SERVICEABLE BATTERIES AS NEEDED.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Unknown
Issued 10 October 1986 Resolved
CONDUCT ANNUAL SERVICING OF ALL FIXED AND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Lifesaving
Issued 3 October 1985 Resolved
REPLACE RIG PARACHUTE FLARES.
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985
Lifesaving
Issued 3 October 1985 Resolved
REPLACE RING BUOY SMOKE FLOAT SPACER BARS.
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985
Electrical
Issued 3 October 1985 Resolved
REPAIR EMERGENCY GENERATOR OVERSPEED AND LOW LUBE OIL TRIPS TO PROVIDE PROPER OPERATIONS.
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985
Construction/Loadline
Issued 3 October 1985 Resolved
ADJUST WATERTIGHT DOORS TO PROVIDE PROPER OPERATION.
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985
Lifesaving
Issued 3 October 1985 Resolved
CONDUCT FIRE AND BOAT DRILLS WHEN MANNED.
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985
Electrical
Issued 3 October 1985 Resolved
REPAIR EMD LOW LUBE OIL TRIPS ON #2 AND #3 GENERATORS
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985
Deck/Cargo
Issued 11 April 1985 Resolved
INSPECT MUD PIT DUMP VALVES 2 AND 3.
Condition: Unknown
Due 11 April 1985
Resolved 11 April 1985
Construction/Loadline
Issued 11 April 1985 Resolved
PROVIDE VIDEO SCAN AND RECORD FOR BOTTOM OF MATS.
Condition: Unknown
Due 11 April 1985
Resolved 11 April 1985
Engineering
Issued 4 October 1984 Resolved
REMOVE ALL OF THE BRASS VALVES FROM THE FUEL OIL DAY TANK. 46CFR56.50
Condition: Unknown
Due 4 October 1984
Resolved 4 October 1984
Unknown
Issued 4 October 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL TELEDYNE 20 DN651875
Condition: Unknown
Due 4 October 1984
Resolved 4 October 1984
Electrical
Issued 4 October 1984 Resolved
SUBMIT FOR APPROVAL THREE COPIES OF THE HAZARDOUS LOCATION DRAWING TO [name withheld], LOUISIANA AS REQUIRED BY 46 CFR 107.305 AND 46CFR 110.25-1(K)
Condition: Unknown
Due 4 October 1984
Resolved 4 October 1984
Unknown
Issued 29 September 1983 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE TELEDYNE 20, DN651875.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983
Unknown
Issued 29 September 1983 Resolved
CONDUCT AN OPERATIONAL TEST OF BOTH LIFE CAPSULES.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983
Unknown
Issued 29 September 1983 Resolved
INSTALL PERMANENT RAILINGS IN WAY OF THE MANILA LINE ON THE STARBOARD SIDE IN THE VICINITY OF THE CRANE.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983
Unknown
Issued 29 September 1983 Resolved
PROVIDE APPROVED PLANS AND DEMONSTRATE THE PROPER OPERATION OF THE EMER- GENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983
Unknown
Issued 29 September 1983 Resolved
CONDUCT A FIRE AND ABANDON RIG DRILL PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983
Unknown
Issued 29 September 1983 Resolved
PROVIDE APPROVED PLANS FOR THE INDUSTRIAL SYSTEMS.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983

Casualty record · 2

23 July 2004Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 2241821
29 January 2007Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · activity 2867685
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

RBF 253 (2004), THE 253 (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.