MAURY USCG vessel records
← All vessels

LAS CUEVAS

Built
2000
Last inspected
23 June 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 June 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9209283
Flag
ISLE OF MAN
Maury page id
psix-18939

Documentation record

Tonnage as PSIX records it55262 - Displacement, Metric Ton
45299 - Dead Weight, Metric Ton
27955 - Convention (Subpart B), Gross Ton
11956 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

23 June 2020 PSC C · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6981801
19 June 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6709354
29 April 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6401822
1 February 2018 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6343986
20 November 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6310023
21 July 2017 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6216411
17 July 2017 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6213797
28 June 2017 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6190588
22 January 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6071460
6 January 2016 COC-CHEM Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5789483

Deficiency record · 6

Engineering › Compressed Air System (control) › Compressor
Issued 21 July 2017 Resolved
1499-(Other Aux Machinery)-The condition of the ship and equipment shall be maintained to ensure the ship will remain fit to proceed to sea. The vessel experienced loss of pwr due to air introduced into cooling system. - 74 SOLAS ('14 cons)I/11 - See narrative for explanation.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 July 2017
Resolved 21 July 2017
Resolution: Received, reviewed, and accepted class report from NKK. See narrative. Class Report is in Documents.
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2017 Resolved
Vessel sustained inset to aft port side hull below ships waterline between frames 48 and 50 following collision with tug. rectify defieciency prior to next U.S port after sailing foreign to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 July 2017
Resolved 5 July 2017
Resolution: Vessel was inspeced and cleared by class.
Engineering › Steering Gear System › Solenoid Valve
Issued 22 January 2017 Resolved
0936 - Steering gear - Steering gear control shall be provided for the main steering gear, both on the navigation bridge and in the steering gear compartment. When testing in NFU mode and emerg/local mode for steering gear pumps 1 and 2, PSCO observed a 5 degree per 41 sec drift to stbd. 74 SOLAS (01) II-1/27.7.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 22 January 2017 Resolved
0611 - Lifeboat inventory - These rations shall be kept in airtight packaging. PSCO observed that 5 of 30 food rations in the port side lifeboat were no longer kept in airtight packaging. 74 SOLAS (14) III/34 LSA Code Chapt IV/4.4.8.12 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2017
Resolution: Received a class report from NKK stating 6 food rations were placed in the port lifeboat.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 22 January 2017 Resolved
1499 - Other (Prop & Aux Machinery) - In a ship which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed evidence of a fuel leak from the burner on the auxiliary boiler, this was evidenced by a puddle of oil underneath the burner. 74 SOLAS (01) II-2/15.2 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 25 January 2017
Resolution: Received class report from NKK stating the deficiency was rectified.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 January 2017 Resolved
9900 - Other (not clearly hazardous) - Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed several doors for A-60 boundaries that utilized hold back hooks. There was one door held back in the machinery space. The fire plan did not give indication of which doors are supposed to be self-closing. 74 SOLAS (01) II-2/47.2 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 25 January 2017
Resolution: Received class report from NKK stating the deficiency was rectified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.