Records from 2005 to 2026. Most recent: inspection, 20 February 2026.
Documentation record
Registered dimensions (L × B × D)143.3 ft × 29.8 ft × 12.5 ft
Registered tonnagegross 89 / net 61
ITC dimensions (L × B × D)143.3 ft × 29.8 ft × 12.5 ft
ITC tonnagegross 347 / net 104
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 2005
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it347 - Convention (Subpart B), Gross Ton
89 - Regulatory (Subpart C or D), Gross Ton
104 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
20 February 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8295153
20 March 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8097008
18 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8095819
11 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7931972
3 March 2023
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7645280
8 June 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7472294
27 May 2021
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7218365
2 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7155194
12 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7139807
23 June 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6987853
16 March 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6926105
19 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6627834
11 February 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6623839
21 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6358513
23 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6110439
10 March 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6102724
18 March 2016
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5835809
24 July 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4395446
8 February 2012
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4236215
25 February 2011
Construction Oversight · Hull Examination · Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3952406
3 March 2010
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3688452
5 February 2009
Hull Examination · Administrative Inspection · Drydock Exam · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3412812
19 February 2008
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3149567
17 October 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3084853
15 March 2007
Re-Inspection · Ballast Water Examination · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2991353
14 March 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598073
8 March 2005
Initial Construction-Excluding Oversight · Hull Examination · COI Inspection · Ballast Water Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2305867
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 March 2023
Resolved
Vessels that operate on a Coastwise or Oceans route must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces. Crew accommodation spaces are not equipped with fire detectors. Install interconnected fire detection system in all required spaces.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2023
Resolved 27 April 2023
Resolution: Installed smoke detectors at each state room and modified bridge fire panel.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 March 2023
Resolved
Vessels that operate on a Coastwise or Oceans route must conduct emergency egress training for each member of the crew at least monthly and each time a new crew member joins such vessel. This training must be completed and logged in accordance with CG regulations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 31 March 2023
Resolution: Conducted emergency egress training with crew and documented it.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 June 2022
Resolved
In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function.
Gages for air receivers were more than 2 times the pressure.
46CFR54.15-5(f)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2022
Resolved 6 July 2022
Resolution: Installed new guages.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 June 2022
Resolved
Exhaust gas must not leak from the piping or connections.
Found cracked weld near the end of the exhaust pipe.
46CFR182.430(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 June 2022
Resolved 9 June 2022
Resolution: Welder was on scene and rectified prior to completion of inspection.
Documentation › Logs/Records › Oil Record Book
Issued 3 March 2010
Resolved
Provide Oil Record book and log all entries when the OWS is in operation. To be checked and verified at next inspection.
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 11 March 2011
Documentation › Logs/Records › Logbook (official)
Issued 3 March 2010
Resolved
Log all predeparture and arrival checklists. To be verified at next inspection.
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 11 March 2011
Engineering › Steering Gear System › Valve, Control
Issued 8 March 2005
Resolved
Provide self centering aft steering control joystick.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 14 March 2006