SC HONGKONG is a 2001 tank ship. The Coast Guard has recorded 30 inspections since 2001, most recently in December 2011, along with 5 deficiencies and 7 operational controls.

Records from 2001 to 2011. Most recent: inspection, 24 December 2011.

Built
2001
Last inspected
24 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9187904 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
HONG KONG
—
Maury page id
psix-35487

Inspections, by type

…with no type recorded11
Years with a record 10 calendar years (2001–2011)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7006 - Convention (Subpart B), Net Ton
22377 - Dead Weight, Ton
29400 - Displacement, Ton
13753 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STOLT VISION Tank Ship · MISLE 792071 · 16 July 2009 · activity 3537567

Inspection history · 30

24 December 2011 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4209010
16 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3537567
1 January 2009 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · COC-CHEM Renew · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3387317
17 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3346588
31 January 2008 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3139854
28 January 2008 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3137542
26 January 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3136972
22 January 2008 ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3134352
7 September 2007 MARPOL Annex II Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3052157
30 July 2007 MARPOL Annex II Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3011895
9 July 2007 MARPOL Annex II Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2989528
30 April 2007 MARPOL Annex II Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2919010
29 April 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2918173
25 January 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2861940
13 July 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2711633
28 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2593381
17 October 2005 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2516639
26 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2343219
20 April 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2338841
30 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2250419
29 November 2004 COC-CHEM Renew
Type not classified · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2249450
9 August 2004 ISPS II Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2160493
16 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2026602
19 October 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1931485
13 June 2003 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1816454
13 April 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1773671
14 February 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1486823
10 December 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1487058
22 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294008
22 September 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1073587

Deficiency record · 5

Navigation › Collision/Grounding Avoidance › Radar
Issued 31 January 2008 Resolved
vessel was issued a letter of deviation for a inoperable radar vessel is to repair radar prior to departure and submit a tech report to the coast guard
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2008
Resolved 31 January 2008
Resolution: received tech report stating the radar is repaired and is now working properly
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 25 January 2007 Resolved
Vessel never submitted a notice of Arrival with the National Vessel Movement Center. Vessel is to remain outside territorial waters until NOA is submitted and proper time requirements met (24hr).
Due 25 January 2007
Resolved 26 January 2007
Resolution: Vessel submitted NOA to NVMC.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 17 October 2005 Resolved
Vessel loss propulsion while inbound on the Savannah River. Vessel is to provide have a class surveyor diagnose the malfunction of the main propulsion system and submit a class report to MSU Savannah for review prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2005
Resolution: received class report
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 November 2004 Resolved
OWS for engine room does not work in that the automatic overboard valve does not cycle open via ODM automatic controls as designed. This shall be corrected to satisfaction of Lloyd's surveyor with written class report faxed to USCG attesting to proper operation of this unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 30 November 2004
Resolution: Visited vessel and noted proper operation of this unit this date after repairs were completed by the vessel''s crew.
Operations/Management › Pollution › Control of Garbage
Issued 29 November 2004 Resolved
Shiup's incinerator does not work properly in that the burner failed to fire after numerous attempts and the firebox door safety switch did not function as designed. This shall be corrected to satisfaction of Lloyd's surveyor with written class report faxed to USCG attesting to proper operation of this unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 30 November 2004
Resolution: Visited vessel and noted proper operation of this unit this date after repairs were completed by the vessel''s crew.

Ownership record