STOLT VISION is a 2004 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in November 2024, along with 13 deficiencies and 1 operational control.
Records from 2016 to 2024. Most recent: inspection, 19 November 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25147 - Dead Weight, Metric Ton 32899 - Displacement, Metric Ton 15976 - Convention (Subpart B), Gross Ton 7838 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
19 November 2024COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8036898
Cargo tanks shall be fitted with one of the following types of gauging types: closed device. Types of gauging for individual products are shown in column j in the table of chapter 17.
Cargo tank 12P closed gauging radar is inoperable. Vessel is not permitted to carry any cargo that requires closed gauging in cargo tank 12P as required by column j of chapter 17 of IBC Code.
74 SOLAS (14) VII/10.01 ref IBC Code 13.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 September 2019
Resolved 9 September 2019
Resolution: Received technician report attesting to satisfactory operation of closed gauging system. Tank 3P gauging system is now inoperable. Created special note for follow up. See activity 6802559 for details.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2018Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. Eight fire doors in the accomodation space are not working as intended. Doors were not operating in a self closing manner; wheelhouse entrance (A-0), wheelhouse locker (A-60), B deck crew mess room into galley (A-0), B deck crew mess room to stairway (A-0), U/D emergency escape trunk (A-0), U/D jumper locker (A-0), B deck port side exit (S), U/D port side exit (S).
(04) SOLAS II-2 14.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2018
Resolution: Recieved Class Report from LR. Class report stated fire doors were replaced and are now in good working order. Class Report has been uploaded into activity.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 August 2017Resolved
On July 30, 2017 the STOLT VISION provided the US Coast Guard with a cargo waiver form with an attestation that all cargo systems were working properly. On August 02, 2017, the STOLT VISION attested on their Declaration of Inspection for cargo operations with the Intercontinental Terminal that all cargo systems were working properly. This information was deemed to be false/fraudulent.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2017
Resolved 15 August 2017
Resolution: Stolt representatives and legal counsel admitted to the violation and paid a ticket in the amount of $1000, (Ticket number 00314924).
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 3 August 2017Resolved
Pressure sensor for #3P cargo tank found to be inoperative. (74 SOLAS 14 VII/10.1 REF IBC 8.3.3) (15ac) See M # 6226590 for full text of deficiency.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that new pressure sensor had been installed and tested in presence of attending class surveyor.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 3 August 2017Resolved
High level alarm for #3S cargo tank is continuously alarming even though the tank is empty. (74 SOLAS 14 VII/10.1 REF IBC 15.19.6) (15ac) See M # 6226590 for full text of deficiency.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that new high level alarm had been installed and tested in presence of attending class surveyor.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 3 August 2017Resolved
Radar gauge system for #1S cargo tank currently malfunctioning and intermitted reading -0.500m. (74 SOLAS 14 VII/10.1 REF IBC 13.1.1) (15ac) See M # 6226590 for full text of deficiency.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that new gauge display had been installed and verified in presence of attending class surveyor.
Pressure indicator on #11S framo pump reads 60 bar even though pump is off and there is no pressure in the line. (74 SOLAS 14 VII/10.1 REF IBC 1.5.3) (15ac) See M # 6226590 for full text of deficiency.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that pressure gauge setting was readjusted by vessel crew and tested in presence of attending class surveyor.
Documentation › Certificates/Documents › International Certificate of Fitness (IBC Code)
Issued 3 August 2017Resolved
Vessel is a type 1 chemical tanker and Attachment 1 to Certificate of Fitness states that type 1 products can be loaded in all tanks, but only cargo tanks 3PC, 3SC, 11PS, and 11SC are located at a distance of at least B/5 inboard from sideshell. Therefore, tank group authorization on Certificate of Fitness is incorrect. (74 SOLAS 14 VII/10.1 REF IBC 2.6.1) (50ac) See M # 6226590 for full text
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 10 August 2017
Resolution: Received copy of updated attachment to CoF restricting carriage of products required to be carried in Type 1 tanks to #3 and #11 center tanks.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 3 August 2017Resolved
Pressure alarms were silenced and cargo operations continued, which is in direct contradiction to company SMS. Additionally, 4 cargo tanks found with incorrect pressure alarm set-points. This provides objective evidence of non-compliance with SMS cargo handling procedures. (74 SOLAS 14 IX/3.1 REF ISM 6.4) (15ac) See M # 6226590 for full text of deficiency.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received copy of internal audit report.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 15 July 2016Resolved
IBC 1.5.3.1
Cargo tank radar monitoring system panel located in the cargo control room does not operate properly without a heating fan blowing into its exhaust vent. Radar monitoring system should work without heating fan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Cargo tank level monitoring system was serviced by OEM authorized service technician and service report reviewed by Coast Guard and the Classification Society (ABS).
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 July 2016Resolved
Lifeboats require 25000kj total of food rations. Starboard lifeboat only has 19000kj total.
74 SOLAS (2014 Cons Ed.) III/13.1.4
LSA Ch IV/4.8.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Food rations ordered and placed inside both port and starboard lifeboats.
Engineering › Fuel Oil Service System › Piping
Issued 15 July 2016Resolved
Fuel oil return line from main engine found actively leaking. Oil found pooled on main engine. 74 Solas (2014 Cons Ed) II-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 July 2016
Resolution: Previously leaking main engine fuel oil recirculation line pressure regulating valve was verified to have been overheauled by the crew. New bonnet, diaphragm, and seals were installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 July 2016Resolved
Soft patch found on #2 generator salt water piping. Salt Water cooling pump for the intert gas generator found actively leaking from SW piping.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 October 2016