MAURY USCG vessel records Sign in
← All vessels

STOLT VISION

STOLT VISION is a 2004 tank ship. The Coast Guard has recorded 39 inspections since 2005, most recently in November 2024, along with 14 deficiencies and 8 operational controls, 2 with no removal date recorded.

Records from 2005 to 2024. Most recent: inspection, 19 November 2024.

Built
2004
Last inspected
19 November 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

9274329 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
792071
Flag
LIBERIA
—
Maury page id
psix-792071

Inspections, by type

…with no type recorded13
Years with a record 18 calendar years (2005–2024)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25147 - Dead Weight, Metric Ton
32899 - Displacement, Metric Ton
15976 - Convention (Subpart B), Gross Ton
7838 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SC HONGKONG Tank Ship · MISLE 35487 · 16 July 2009 · activity 3537567

Inspection history · 39

19 November 2024 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8036898
3 September 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7988009
29 August 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7992166
14 October 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7808389
6 July 2023 Administrative Inspection · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7735210
21 November 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7597737
3 January 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7375092
2 January 2022 Ballast Water Examination · COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7372695
17 September 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7059831
6 September 2019 Administrative Inspection · ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6802559
12 March 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6641245
15 September 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6540971
9 September 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6536040
3 August 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6226590
13 January 2017 COE-Administrative
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6073528
20 October 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6026300
15 July 2016 Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5936936
18 August 2015 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5214712
11 August 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4951879
20 January 2012 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4236049
21 February 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3946898
24 November 2010 Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3898138
20 November 2010 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3890436
19 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3890437
16 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3537567
12 July 2009 Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3532011
11 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3531511
15 April 2009 MARPOL Annex V Examination · NPV Safety Exam · MARPOL Annex VI Survey · Ballast Water Examination · MARPOL Annex I Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3449200
14 April 2009 Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3456007
9 April 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3449198
11 November 2008 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3359961
5 October 2007 Loadline Exam · Administrative Inspection · COC-CHEM Renew · MARPOL Annex I Examination · ILO-147 Exam · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3073480
26 July 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3008979
24 July 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3006164
26 January 2007 MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2862115
14 September 2006 ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2778493
30 May 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2664611
30 September 2005 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2505181
30 September 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2506470

Deficiency record · 14

12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 6 September 2019 Resolved
Cargo tanks shall be fitted with one of the following types of gauging types: closed device. Types of gauging for individual products are shown in column j in the table of chapter 17. Cargo tank 12P closed gauging radar is inoperable. Vessel is not permitted to carry any cargo that requires closed gauging in cargo tank 12P as required by column j of chapter 17 of IBC Code. 74 SOLAS (14) VII/10.01 ref IBC Code 13.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 September 2019
Resolved 9 September 2019
Resolution: Received technician report attesting to satisfactory operation of closed gauging system. Tank 3P gauging system is now inoperable. Created special note for follow up. See activity 6802559 for details.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2018 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. Eight fire doors in the accomodation space are not working as intended. Doors were not operating in a self closing manner; wheelhouse entrance (A-0), wheelhouse locker (A-60), B deck crew mess room into galley (A-0), B deck crew mess room to stairway (A-0), U/D emergency escape trunk (A-0), U/D jumper locker (A-0), B deck port side exit (S), U/D port side exit (S). (04) SOLAS II-2 14.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2018
Resolution: Recieved Class Report from LR. Class report stated fire doors were replaced and are now in good working order. Class Report has been uploaded into activity.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 August 2017 Resolved
On July 30, 2017 the STOLT VISION provided the US Coast Guard with a cargo waiver form with an attestation that all cargo systems were working properly. On August 02, 2017, the STOLT VISION attested on their Declaration of Inspection for cargo operations with the Intercontinental Terminal that all cargo systems were working properly. This information was deemed to be false/fraudulent.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2017
Resolved 15 August 2017
Resolution: Stolt representatives and legal counsel admitted to the violation and paid a ticket in the amount of $1000, (Ticket number 00314924).
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 3 August 2017 Resolved
Pressure sensor for #3P cargo tank found to be inoperative. (74 SOLAS 14 VII/10.1 REF IBC 8.3.3) (15ac) See M # 6226590 for full text of deficiency.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that new pressure sensor had been installed and tested in presence of attending class surveyor.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 3 August 2017 Resolved
High level alarm for #3S cargo tank is continuously alarming even though the tank is empty. (74 SOLAS 14 VII/10.1 REF IBC 15.19.6) (15ac) See M # 6226590 for full text of deficiency.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that new high level alarm had been installed and tested in presence of attending class surveyor.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 3 August 2017 Resolved
Radar gauge system for #1S cargo tank currently malfunctioning and intermitted reading -0.500m. (74 SOLAS 14 VII/10.1 REF IBC 13.1.1) (15ac) See M # 6226590 for full text of deficiency.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that new gauge display had been installed and verified in presence of attending class surveyor.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 August 2017 Resolved
Pressure indicator on #11S framo pump reads 60 bar even though pump is off and there is no pressure in the line. (74 SOLAS 14 VII/10.1 REF IBC 1.5.3) (15ac) See M # 6226590 for full text of deficiency.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received class report stating that pressure gauge setting was readjusted by vessel crew and tested in presence of attending class surveyor.
Documentation › Certificates/Documents › International Certificate of Fitness (IBC Code)
Issued 3 August 2017 Resolved
Vessel is a type 1 chemical tanker and Attachment 1 to Certificate of Fitness states that type 1 products can be loaded in all tanks, but only cargo tanks 3PC, 3SC, 11PS, and 11SC are located at a distance of at least B/5 inboard from sideshell. Therefore, tank group authorization on Certificate of Fitness is incorrect. (74 SOLAS 14 VII/10.1 REF IBC 2.6.1) (50ac) See M # 6226590 for full text
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 10 August 2017
Resolution: Received copy of updated attachment to CoF restricting carriage of products required to be carried in Type 1 tanks to #3 and #11 center tanks.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 3 August 2017 Resolved
Pressure alarms were silenced and cargo operations continued, which is in direct contradiction to company SMS. Additionally, 4 cargo tanks found with incorrect pressure alarm set-points. This provides objective evidence of non-compliance with SMS cargo handling procedures. (74 SOLAS 14 IX/3.1 REF ISM 6.4) (15ac) See M # 6226590 for full text of deficiency.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2017
Resolved 10 August 2017
Resolution: Received copy of internal audit report.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 15 July 2016 Resolved
IBC 1.5.3.1 Cargo tank radar monitoring system panel located in the cargo control room does not operate properly without a heating fan blowing into its exhaust vent. Radar monitoring system should work without heating fan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Cargo tank level monitoring system was serviced by OEM authorized service technician and service report reviewed by Coast Guard and the Classification Society (ABS).
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 July 2016 Resolved
Lifeboats require 25000kj total of food rations. Starboard lifeboat only has 19000kj total. 74 SOLAS (2014 Cons Ed.) III/13.1.4 LSA Ch IV/4.8.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Food rations ordered and placed inside both port and starboard lifeboats.
Engineering › Fuel Oil Service System › Piping
Issued 15 July 2016 Resolved
Fuel oil return line from main engine found actively leaking. Oil found pooled on main engine. 74 Solas (2014 Cons Ed) II-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 July 2016
Resolution: Previously leaking main engine fuel oil recirculation line pressure regulating valve was verified to have been overheauled by the crew. New bonnet, diaphragm, and seals were installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 July 2016 Resolved
Soft patch found on #2 generator salt water piping. Salt Water cooling pump for the intert gas generator found actively leaking from SW piping.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 October 2016
Construction/Loadline › Structures › Deck Plating
Issued 12 July 2009 Resolved
Vessel was damaged while docking at Texas City Dock 14. Tug pulled chalk and 25' of railing from main weather deck, and caused some super structure damage.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2009
Resolved 13 July 2009
Resolution: Vessel made temporary repairs and is sail with in it''s condition of class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.