Records from 2008 to 2026. Most recent: inspection, 4 May 2026.
Inspection history · 11
4 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8361370
29 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8357929
26 December 2025
PSC B
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8287277
19 November 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8271175
21 October 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8256627
16 October 2025
PSC A · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8253566
1 February 2019
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6632446
22 July 2015
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5192803
22 July 2015
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5200621
22 September 2014
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4989385
16 May 2008
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3233994
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 December 2025
Resolved
The safety of the towing vessel is the responsibility of the master. He or she must ensure that adequate corrective action is taken and is not to proceed until it is safe. All of the vessels watertight doors show daylight when closed. Repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 January 2026
Resolved 29 April 2026
Resolution: Gaskets were changed out by ships crew
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 December 2025
Resolved
Extension cords must not be used as a permanent connection to a source of electrical power. A wifi module and a household refrigerator in the engine room are connected with electrical extension cords.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2026
Resolved 29 April 2026
Resolution: Extension cords removed.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 26 December 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and is ready at all times. The vessels immersion suits are all over 10 years old and need to be serviced yearly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2026
Resolved 29 April 2026
Resolution: Suits were serviced. rcvd invoice from POC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 October 2025
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed, made safe. On both generators guards are missing on rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 19 November 2025
Resolution: Generators were fitted with guards.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2025
Resolved
Fire detection systems except as provided in paragraph (a)(8) of this section each towing vessel must have a fire detection system installed to detect engine room fires. Fire detection systems in the engine were not installed properly to manufacturer specifications.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 21 October 2025
Resolution: fire system is now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 October 2025
Resolved
Survival craft must be stowed in accordance with the requirements of 199.130 of this chapter. Each liferaft must be arranged for float free launching. The arrangement must ensure that the liferaft when released and inflated are not dragged under by the sinking vessel. Both liferafts are arranged so they could be dragged under by the sinking vessel.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 21 October 2025
Resolution: survivial craft installed properly
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 October 2025
Resolved
Survival craft must be stowed in accordance with the requirements of 199.130 of this chapter. The deck railing is bent over the starboard life raft impeding its float free arrangement.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 21 October 2025
Resolution: hand rail was cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2025
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed, made safe. On both generators guards are missing on rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 21 October 2025
Resolution: all guards have been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2025
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested twice every five years. Relief valves setting and testing frequency is unknown.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2025
Resolved 19 November 2025
Resolution: Received reports for relief valve testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The starboard bridge wing lifebuoy retroreflective tape is faded and the lifeline is deteoriated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 19 November 2025
Resolution: The reflective tape and lifelines have been renewed on lifebuoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Exposed wires were found on the aft generator starter, the steering gear system, and an open electrical box in the aft engine room ceiling.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025
Resolved 19 November 2025
Resolution: The exposed wires on the aft generator starter, steering gear system, and the open electrical box in the aft engine room ceiling have been corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2025
Resolved
Each lifejacket must be marked in block capital letters with the name of the vessel. Lifejackets are marked with wrong vessel name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2025
Resolved 21 October 2025
Resolution: all jackets are properly marked.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 October 2025
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Open containers of oil were found forward starboard side of the engine room.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2025
Resolution: all extra waste oil has been removed.