MAURY USCG vessel records Sign in
← All vessels

S-2006

S-2006 is a 1981 freight barge. The Coast Guard has recorded 28 inspections since 1993, most recently in December 2019, along with 24 deficiencies, 1 operational control and 1 casualty investigation in 2018.

Records from 1993 to 2019. Most recent: inspection, 3 December 2019.

Built
1981
Last inspected
3 December 2019
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

355684
Flag
UNITED STATES
—
Maury page id
psix-355684

Inspections, by type

…with no type recorded1
Years with a record 18 calendar years (1993–2019)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)191.8 ft × 55.0 ft × 12.0 ft
Registered tonnagegross 957 / net 287
ITC dimensions (L × B × D)191.8 ft × 55.0 ft × 12.0 ft
ITC tonnagegross 957 / net 287
BuilderKEPPEL PHIL. SHIPYARD INC · BAUAN, BATANGAS, PHILIPPINES · built 1981
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPITI, GU
Trade endorsementsRegistry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it957 - Convention (Subpart B), Gross Ton
287 - Convention (Subpart B), Net Ton
2000 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHAMORRO Towing Vessel · MISLE 132419 · 22 March 2018 · activity 6385380

Inspection history · 28

3 December 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6865996
10 May 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6420207
23 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6380024
22 March 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6385380
5 March 2018 MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6364413
23 January 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6341866
22 December 2017 Uninspected Other · Administrative Inspection · Load Line/Change of Employment
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6328811
23 August 2016 Examination of Repairs · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5980466
30 September 2015 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5731153
13 August 2015 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5231765
18 June 2015 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5156412
21 March 2014 COI Inspection · MARPOL Annex VI Survey · Drydock Exam · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4820137
27 September 2012 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Annual Inspection · MARPOL Annex I Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4076686
15 March 2010 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3695545
24 February 2010 Annual Inspection · MARPOL Annex I Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3684273
6 December 2008 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3393080
15 October 2007 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3080068
14 July 2006 Internal Structural Exam · MARPOL Annex I Examination · Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2644327
28 October 2004 MTSA Verification
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2240944
24 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2030505
24 January 1998 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115508
18 June 1997 Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115976
5 August 1996 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1090120
10 July 1995 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1186077
1 September 1994 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1170989
15 September 1993 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 843184
14 July 1993 Hull Examination · Reflagging & Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 846478
14 July 1993 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 855206

Deficiency record · 24

Construction/Loadline › Hull › Hull Plating
Issued 24 March 2018 Resolved
Submit repair proposal for damage sustained as a result of grounding on March 24, 2018. Repairs shall be conducted to satisfaction of attending USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2018
Resolved 5 September 2018
Resolution: Vessel scuttled.
Construction/Loadline › Hull › Hull Plating
Issued 15 September 2016 Resolved
Provide U/T gauging report for all bow rakes, visible wasted hull plating at the bottom of each void, and hull plating in the #1 starboard double bottom; and provide updated repair plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 3 December 2019
Construction/Loadline › Markings › Load Line Mark
Issued 30 September 2015 Resolved
Vessel's port and starboard side hull is not marked in accordance with Load Line Certificate issued by Class and 46 CFR 42.13-40.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2015
Resolution: Load line markings applied to the satisfaction of attending marine inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 September 2015 Resolved
Repair inoperable stern light.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2015
Resolution: Stern light battery replaced with new and operating as designed.
Deck/Cargo › Towing › Chocks
Issued 30 September 2015 Resolved
Renew/replace all identified wasted and missing horns for double horn bollards as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2015
Resolution: All horns cropped out and renewed.
Construction/Loadline › Structures › Manhole
Issued 30 September 2015 Resolved
Renew wasted stud for starboard side aft rake manhole cover stud as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2015
Resolution: Waisted stud removed and renewed.
Construction/Loadline › Hull › Side Shell
Issued 30 September 2015 Resolved
Wasted rub rail on starboard side shell. Repair as original.
Due 30 October 2015
Resolved 8 October 2015
Resolution: All water drained from rub rail and crack was ground down and welded to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Rake
Issued 30 September 2015 Resolved
Remove water from forward rake for USCG for inspection from on-deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2015
Resolution: All water removed from rake space. Space found to be in satisfactory condition.
Documentation › Certificates/Documents › IOPP Certificate
Issued 1 September 2015 Resolved
IOPP certificate was not on board.
Action required: 705 - Other - as specified
Resolved 3 December 2019
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2015 Resolved
COI was not onboard the vessel.
Action required: 705 - Other - as specified
Resolved 3 December 2019
Deck/Cargo › Cargo Stowage › General
Issued 13 August 2015 Resolved
Containers were not stowed on vessel in accordannce with the approved Stability Letter.
Action required: 705 - Other - as specified
Resolved 3 December 2019
Deck/Cargo › Cargo Stowage › General
Issued 13 August 2015 Resolved
Failure to properly stow hazmat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2019
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 13 August 2015 Resolved
Failure to comply with DCM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2019
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 November 2012 Resolved
(#1 starboard double bottom) Crop and renew 3rd gusset from inboard side at the forward, inboard corner of space.
Due 18 January 2014
Resolved 7 August 2014
Resolution: Area has been cropped and renewed. BV surveyor witnessed fit up, welding, and testing. USCG inspector witnessed final repair.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2010 Resolved
Replace and repair as needed stbd side wiring to Navigational light. Battery storage box is not approved and one will need to be provided.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 15 March 2010
Resolution: Wiring was removed and new LED high intensity nav lights installed. Light are an integrated solar panel, light, and battery combo housed in/on a pelican case for easy removal if needed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2010 Resolved
Properly secure wiring for port and fwd center white navigation light to barge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 15 March 2010
Resolution: Wiring removed and an integrated LED light installed with battery, light, and solar panel combo housed in/on a Pelican case.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2010 Resolved
Show proper operation of FWD Navigational lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2010
Resolution: Verified proper operation of FWD navigational lights.
Construction/Loadline › Structures › Manhole
Issued 24 February 2010 Resolved
Replace missing hatch cover lag securing bolts as needed for hatch covers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 15 March 2010
Resolution: Repaired/replaced nine lag securing bolts on hatches port/stbd side of vessel to the satisfaction of the attending Coast Guard Marine Inspector.
Deck/Cargo › Towing › Tackle
Issued 24 February 2010 Resolved
Aft Port side stopper cable has one complete strand broken and should be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 15 March 2010
Resolution: Aft port side stopper cable was removed from vessel as it is not needed for the current operation of the vessel to the satisfaction of the attending Coast Guard Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 October 2007 Resolved
Repair or replace all around white light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2007
Resolved 24 October 2007
Resolution: Observed the all around white light working, all sat.
Construction/Loadline › Markings › Load Line Mark
Issued 15 October 2007 Resolved
Paint load line marks as per 46 CFR 31.25-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2007
Resolved 24 October 2007
Resolution: Vessels reps painted all the loadlines, draft marks with sat results.
Deck/Cargo › Ballast › Tank
Issued 15 October 2007 Resolved
Repair (2) fractures in stbd ballast tank's # 1, # 3.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 November 2007
Resolved 24 October 2007
Resolution: Vessels rep welder repaired the two fractures on the tops of both effected tanks.
Construction/Loadline
Issued 14 July 1993 Resolved
PREPARE FOR INSPECTION THE BOW CENTER VOID TANK TO VERIFY THE COMPLETED WORK ITEMS IAW THE PROPOSED REINFORCEMENT PLAN S-2006, APPROVAL DATE 3JUN93BY HONMS, TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Electrical
Issued 14 July 1993 Resolved
PROVE THE PROPER OPERATION OF THE CONTAINERIZED DIESEL GENERATOR'S SAFETY SHUTDOWNS & ALARMS AND THE FIXED FIRE FIGHTING FLOODING SYSTEM TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR PRIOR TO VESSEL'S 1ST CARGO LOADING OR UPON VESSEL'S ARRIVAL TO NEXT U.S. PORT.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993

Casualty record · 1

22 March 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6385380
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.