Records from 2007 to 2026. Most recent: inspection, 6 January 2026.
Inspection history · 18
6 January 2026
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8291005
13 November 2025
Examination of Repairs · Vessel Attendance · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8268064
2 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8225154
16 December 2024
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8047987
9 January 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8045286
1 November 2023
Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7818665
22 February 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7640416
14 February 2023
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7636721
26 October 2022
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7584294
14 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7411729
24 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7372167
23 December 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7372465
10 September 2021
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7309425
27 January 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6896937
27 September 2018
Examination of Repairs · Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6548692
23 October 2017
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293232
25 January 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6077613
21 April 2016
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5857444
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2026
Resolved
All vessels shall be provided with the bilge pumps in accordance with Table 182.25-10(a). Vessel is required 2 fixed power pumps. Vessel could not demonstrate proper operation of the emergency bilge pump. Vessel is required to make permanent repairs and demonstrate proper operation of both bilge pumps to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2026
Resolved 7 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2026
Resolved
On a vessel of atleast 26 feet, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space. MI observed the visual indicator for the engine room bilge alarm inoperable. Repair indicator to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2026
Resolved 7 January 2026
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 January 2026
Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. MI observed several areas on the main engine exhaust piping that had exposed exhaust pipe. Install grates or lagging on all exposed exhaust piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 13 January 2026
Resolution: Received photos showing properly installed lagging on all exposed exhaust areas
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2026
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed an electrical outlet in the port side aft berthing area missing a faceplate, full of lint and the enclosure broken and not properly attached to the bulkhead. Replace or remove electrical outlet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 7 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2021
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel only has 36 Adult life jackets and 04 children life jackets on board. Total persons allowed is 36.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Corrected passenger count on COI. Vessel had sufficient amount of life jackets onboard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 February 2020
Resolved
Engine room bilge has approximately 12-14" of oily water in FWD section. Properly pump and clean to mitigate fire risk and meet stability letter requirements to satisfaction of CG inspector, prior to carraige of passengers or cargo.
46CFR185.12
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved photo of pumped/cleaned bilge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2020
Resolved
Generator windings have excessive oil and lint creating a risk of fire. Clean to satisfaction of CG Marine inspector, prior to carraige of passengers or cargo.
46CFR183.10-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved photo of cleaned windings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 February 2020
Resolved
Gaskets for deck scuttles not serviceable. Repair/replace to the satisfaction of CG Marine inspector, prior to carraige of passengers or cargo.
46CFR185.30-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved photo of replaced gaskets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2020
Resolved
STBD main engine has multiple oil and exhaust leaks posing a risk to damage and fire. Repair to satisfaction of CG marine inspector, prior to carriage of passengers or cargo.
46CFR182.10-05
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved report of exhaust leaks corrected. Oil leaks corrected on spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2020
Resolved
Generator starting battery terminals corroded. Repair to satisfaction of CG marine inspector within 14 days.
46CFR182.10-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2020
Resolution: Recieved photo of cleaned terminals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2020
Resolved
Exhaust supporting brackets for main engines missing bolts on the overhead repair to satisfaction of CG marine inspector within 14 days.
46CFR182.10-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2020
Resolution: Recieved photo of bolts in brackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2020
Resolved
Steering helm pump under pilot house console, has signs of hydraulic leak. Repair to the satisfaction of CG marine inspector within 14 days.
46CFR182.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2020
Resolution: Recieved photo of corrected/cleaned leaks.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 September 2018
Resolved
Battery was expired on the Epirb. O/O to provide servicing report from third party authorized facility showing the proper maintenance of the epirb was conducted.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2018
Resolved 24 October 2018
Resolution: Received thrid party servicing report from an authorized dealer ARTEX attesting to the proper batter repalacement and comprehensive servicing of the EPIRB, Test results were all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 September 2018
Resolved
The Navigational charts onboard were not corrected. O/O to correct charts I.A.W the latest BNM or purchase new updated navigational charts for the vessels operating area.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2018
Resolved 24 October 2018
Resolution: Received e-mail receipts and pictures of new updated charts that were purchased. Verified that the charts were for the area's that the vessel operates in.
Engineering › Bilge Water Management System › Not Installed
Issued 23 October 2017
Resolved
No visual alarm is present for the rudder room bilge alarm. Supply visual and audible alarm to the satisfaction of the USCG marine inspector
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation showing proper operation of visual and audible alarm.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 23 October 2017
Resolved
Renew port side MDE exhaust cooling lines, support all other cooling exhaust lines properly to satisfaction of USCG marine inspector.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation showing renewed MDE cooling lines, and installed support of all other cooling exhaust lines.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Distributor (air start)
Issued 23 October 2017
Resolved
Properly secure all MDE air start and lines to satisfaction of USCG MI.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation that all MDE air start and lines have been properly secured.
Engineering › Electric Propulsion System › Wiring
Issued 23 October 2017
Resolved
Remove all dead end wiring from old engine sensors.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation attesting to the removal of all dead end wiring.
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2017
Resolved
Marine charts are not up to date and must be corrected prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 26 January 2017
Resolution: Corrected.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 January 2017
Resolved
Monthly testing was not logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Painter
Issued 25 January 2017
Resolved
Painter lines were not secured to 4 of the 6 lifefloats and must be corrected prior to operating.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 January 2017
Resolved
Lifefloat lights were not attached to of their respective lifefloats; must be corrected prior to operating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 January 2017
Resolved
Starboard engine room hatch covers was missing two bolts, which showed signs of leakage; must be corrected prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.
Engineering › Freshwater Generation System › Pump
Issued 21 April 2016
Resolved
Reinstall pressure switch for fresh water pump.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 April 2016
Resolution: Vessel rep re-installed wire on pressure switch.
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2016
Resolved
Secure shore tie wires in lazarette.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 April 2016
Resolution: Vessel rep secured shore tie to bulkhead in lasarette using brackets.