MAURY USCG vessel records Sign in
← All vessels

BRENDA S

BRENDA S is a 1990 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1990, most recently in January 2026, along with 44 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2021.

Records from 1990 to 2026. Most recent: inspection, 6 January 2026.

Built
1990
Last inspected
6 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3555
356141
Flag
UNITED STATES
367764450, 368438320
Maury page id
psix-356141

Inspections, by type

…with no type recorded7
Years with a record 32 calendar years (1990–2026)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)116.6 ft × 25.0 ft × 11.5 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)116.6 ft × 25.0 ft × 11.5 ft
ITC tonnagegross 199 / net 59
BuilderBREAUX BROTHERS ENTERP · LOREAUVILLE, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFREEPORT, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it199 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ5841MMSI 368438320 · active · compulsorily equipped · granted 3 September 2025, expires 3 September 2035
WDM3555MMSI 368198310 · cancelled · compulsorily equipped · granted 12 May 2021, cancelled 11 September 2025
WDJ3070MMSI 367764450 · active · compulsorily equipped · granted 7 December 2016, expires 7 December 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD5310MMSI 367156470 · expired · compulsorily equipped · granted 21 December 2006, cancelled 25 February 2017 · licensed under a name not among this hull’s recorded names (not shown)
WAP6693MMSI not assigned · expired · compulsorily equipped · granted 5 September 1995, cancelled 21 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARAN GAS ANDROS Tank Ship · MISLE 1599436 · 23 December 2021 · activity 7372465MISS DEBBIE Passenger (Inspected) · MISLE 53467 · 21 July 2007 · activity 3077169BLAKE 404 - CONRETE BARGE Industrial Vessel · MISLE 736254 · 24 November 2004 · activity 2261497MISS MARLA Passenger (Uninspected) · MISLE 739292 · 24 November 2004 · activity 2261497

Inspection history · 55

6 January 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8291005
13 November 2025 Examination of Repairs · Vessel Attendance · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8268064
2 September 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8225154
16 December 2024 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8047987
9 January 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8045286
1 November 2023 Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7818665
22 February 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7640416
14 February 2023 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7636721
26 October 2022 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7584294
14 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7411729
24 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7372167
23 December 2021 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7372465
10 September 2021 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7309425
27 January 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6896937
27 September 2018 Examination of Repairs · Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6548692
23 October 2017 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293232
25 January 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6077613
21 April 2016 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5857444
1 December 2015 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5774466
5 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4201955
30 November 2010 Internal Structural Exam · Drydock Extension
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896705
18 December 2009 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3652452
30 December 2008 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3386612
19 December 2008 Internal Structural Exam · Hull Examination · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3382628
29 October 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3088846
21 July 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3077169
19 January 2006 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2568004
5 March 2005 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2303973
7 January 2005 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260472
29 November 2004 Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2249482
24 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2261497
27 January 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1984032
30 January 2003 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1736572
11 October 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387189
12 October 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464323
14 October 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408390
15 October 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423088
14 October 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467030
31 January 1997 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103632
16 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65768
16 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 224708
18 October 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388146
22 February 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1193701
17 October 1995 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390133
1 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215050
1 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215199
20 October 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449729
28 October 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444761
5 November 1992 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263362
27 April 1992 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264894
3 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 941805
5 November 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249581
17 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912412
16 April 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220102
9 November 1990 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915248

Deficiency record · 44

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2026 Resolved
All vessels shall be provided with the bilge pumps in accordance with Table 182.25-10(a). Vessel is required 2 fixed power pumps. Vessel could not demonstrate proper operation of the emergency bilge pump. Vessel is required to make permanent repairs and demonstrate proper operation of both bilge pumps to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2026
Resolved 7 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2026 Resolved
On a vessel of atleast 26 feet, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space. MI observed the visual indicator for the engine room bilge alarm inoperable. Repair indicator to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2026
Resolved 7 January 2026
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 January 2026 Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. MI observed several areas on the main engine exhaust piping that had exposed exhaust pipe. Install grates or lagging on all exposed exhaust piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 13 January 2026
Resolution: Received photos showing properly installed lagging on all exposed exhaust areas
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed an electrical outlet in the port side aft berthing area missing a faceplate, full of lint and the enclosure broken and not properly attached to the bulkhead. Replace or remove electrical outlet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 7 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2021 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel only has 36 Adult life jackets and 04 children life jackets on board. Total persons allowed is 36.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Corrected passenger count on COI. Vessel had sufficient amount of life jackets onboard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 February 2020 Resolved
Engine room bilge has approximately 12-14" of oily water in FWD section. Properly pump and clean to mitigate fire risk and meet stability letter requirements to satisfaction of CG inspector, prior to carraige of passengers or cargo. 46CFR185.12
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved photo of pumped/cleaned bilge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2020 Resolved
Generator windings have excessive oil and lint creating a risk of fire. Clean to satisfaction of CG Marine inspector, prior to carraige of passengers or cargo. 46CFR183.10-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved photo of cleaned windings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 February 2020 Resolved
Gaskets for deck scuttles not serviceable. Repair/replace to the satisfaction of CG Marine inspector, prior to carraige of passengers or cargo. 46CFR185.30-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved photo of replaced gaskets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2020 Resolved
STBD main engine has multiple oil and exhaust leaks posing a risk to damage and fire. Repair to satisfaction of CG marine inspector, prior to carriage of passengers or cargo. 46CFR182.10-05
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2020
Resolution: Recieved report of exhaust leaks corrected. Oil leaks corrected on spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2020 Resolved
Generator starting battery terminals corroded. Repair to satisfaction of CG marine inspector within 14 days. 46CFR182.10-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2020
Resolution: Recieved photo of cleaned terminals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2020 Resolved
Exhaust supporting brackets for main engines missing bolts on the overhead repair to satisfaction of CG marine inspector within 14 days. 46CFR182.10-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2020
Resolution: Recieved photo of bolts in brackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2020 Resolved
Steering helm pump under pilot house console, has signs of hydraulic leak. Repair to the satisfaction of CG marine inspector within 14 days. 46CFR182.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2020
Resolution: Recieved photo of corrected/cleaned leaks.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 September 2018 Resolved
Battery was expired on the Epirb. O/O to provide servicing report from third party authorized facility showing the proper maintenance of the epirb was conducted.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2018
Resolved 24 October 2018
Resolution: Received thrid party servicing report from an authorized dealer ARTEX attesting to the proper batter repalacement and comprehensive servicing of the EPIRB, Test results were all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 September 2018 Resolved
The Navigational charts onboard were not corrected. O/O to correct charts I.A.W the latest BNM or purchase new updated navigational charts for the vessels operating area.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2018
Resolved 24 October 2018
Resolution: Received e-mail receipts and pictures of new updated charts that were purchased. Verified that the charts were for the area's that the vessel operates in.
Engineering › Bilge Water Management System › Not Installed
Issued 23 October 2017 Resolved
No visual alarm is present for the rudder room bilge alarm. Supply visual and audible alarm to the satisfaction of the USCG marine inspector
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation showing proper operation of visual and audible alarm.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 23 October 2017 Resolved
Renew port side MDE exhaust cooling lines, support all other cooling exhaust lines properly to satisfaction of USCG marine inspector.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation showing renewed MDE cooling lines, and installed support of all other cooling exhaust lines.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Distributor (air start)
Issued 23 October 2017 Resolved
Properly secure all MDE air start and lines to satisfaction of USCG MI.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation that all MDE air start and lines have been properly secured.
Engineering › Electric Propulsion System › Wiring
Issued 23 October 2017 Resolved
Remove all dead end wiring from old engine sensors.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Provided documentation attesting to the removal of all dead end wiring.
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2017 Resolved
Marine charts are not up to date and must be corrected prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 26 January 2017
Resolution: Corrected.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 January 2017 Resolved
Monthly testing was not logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Painter
Issued 25 January 2017 Resolved
Painter lines were not secured to 4 of the 6 lifefloats and must be corrected prior to operating.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 January 2017 Resolved
Lifefloat lights were not attached to of their respective lifefloats; must be corrected prior to operating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 January 2017 Resolved
Starboard engine room hatch covers was missing two bolts, which showed signs of leakage; must be corrected prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.
Engineering › Freshwater Generation System › Pump
Issued 21 April 2016 Resolved
Reinstall pressure switch for fresh water pump.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 April 2016
Resolution: Vessel rep re-installed wire on pressure switch.
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2016 Resolved
Secure shore tie wires in lazarette.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 April 2016
Resolution: Vessel rep secured shore tie to bulkhead in lasarette using brackets.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 December 2015 Resolved
Provide proper cover or guards for rotating machinery on NR 1,2,3 & 4 MDE.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2015
Resolved 2 December 2015
Resolution: Adequate guards were welded onto NR 1,2,3, & 4 MDE.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 1 December 2015 Resolved
Provide means to attach rescue platform to the vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2015
Resolved 2 December 2015
Resolution: Chain a shackle was provided to attach rescue platform to the vessel.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 December 2015 Resolved
Provide emergency lighting fixture for emergency escape hatch in passenger accomadtion space.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2015
Resolved 2 December 2015
Resolution: Emergency light- battle lanter was installed for emergency escape hatch in passenger accomodation area.
Electrical › Electric Supply System (service) › Cable
Issued 1 December 2015 Resolved
Provide mechanical connection for cables on port outboard engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 3 December 2015
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011 Resolved
Vessel's stability information has not been updated to comply with the new assumed average weight per person of 185 pounds as per 46 CFR 178.310(a)(1). Vessel's passenger count has been reduced to 64 until certified in compliance with stability regulations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 October 2012
Resolution: Vessel has new stability letter for MSC Serial #: H1-1021026 post under glass. Vessel is stabile for up to 79 persons but only has lifesaving for 75 Persons.
Stability › Unintentional Flooding › General
Issued 29 October 2007 Resolved
Footlong crack found in sideshell just above generator exhaust doubler. Insert cracked area and test to the satisfaction of Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2007
Resolved 29 October 2007
Resolution: Cracked area inserted and satisfactorily tested.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 29 October 2007 Resolved
The officers onboard do not possess the required Marine Radio Operator Permit. The vessel must have an officer with a valid radio permit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2007
Resolution: Both officers onboard have obtained a valid radio permit.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 January 2005 Resolved
Crop and Renew wasted section of exhaust IWO STBD outboard MDE (doubler).
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2005
Resolved 22 February 2005
Resolution: Repaired.
Construction/Loadline › Hull › Hull Plating
Issued 29 November 2004 Resolved
Make permanent repairs fractured bulwark, starboard side in way of forepeak void. To be completed at next drydock, but no later than 31 January, 2005.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 14 January 2005
Documentation › Certificates/Documents
Issued 30 January 2003 Resolved
VESSEL OPERATING WITH EXPIRED CERTIFICATE OF INSPECTION LEGACY COMPONENT DESC: Certificate of Inspection
Due 30 January 2003
Resolved 31 January 2003
Documentation › Certificates/Documents
Issued 30 January 2003 Resolved
VESSEL OPERATING PAST HULL EXAMINATION DATE LEGACY COMPONENT DESC: Certificate of Inspection
Due 30 January 2003
Resolved 3 February 2003
Navigation
Issued 14 October 1999 Resolved
Provide vessel with nautical puvlication to include 46 CFR Subchapter "T", light list, tide tables, current tables and coast pilot.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Accommodation/Occupational Safety
Issued 14 October 1999 Resolved
Provide ASME approved relief valve for the fwd air receiver.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Lifesaving
Issued 15 October 1998 Resolved
REMOVE 15 MAN LIFE FLOAT FROM VESSEL. RENEW FLOAT NETTING DUE TO DRY-ROT. REDUCE PASSENGER CAPACITY TO 60 PERSONS UNTIL LIFE FLOAT IS REPAIRED.
Condition: Unknown
Due 15 November 1998
Resolved 3 November 1998
Unknown
Issued 17 October 1995 Resolved
PROVIDE DOCUMENTATION THAT COMPANY HAS ESTABLISHED CHEMICAL TESTING PROGRAMAS ID'D IN 46CFR16.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Navigation
Issued 17 October 1995 Resolved
PROVIDE DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Documentation
Issued 17 October 1995 Resolved
PROVIDE TRASH LOG.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Navigation
Issued 5 November 1991 Resolved
REPAIR OR REPLACE MAGNETIC COMPASS.
Condition: Unknown
Due 5 November 1991
Resolved 5 November 1991
Documentation
Issued 9 November 1990 Resolved
PROVIDE ON BOARD A VALID FCC RADIO, TELEPHONEY SAFETY CERTIFICATE.
Condition: Unknown
Due 9 November 1990
Resolved 9 November 1990

Casualty record · 2

21 July 2007Routine · role: Involved in a Marine Casualty · activity 3077169
23 December 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7372465
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

THUNDERAMERICA (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.