Records from 1981 to 2018. Most recent: inspection, 21 February 2018.
Inspection history · 55
21 February 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358776
8 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5738310
2 May 2014
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4850911
2 May 2012
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4306557
9 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4205216
8 February 2011
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3941787
20 April 2009
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3456463
22 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3190038
17 April 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3186442
12 April 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3381890
21 July 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3077169
12 April 2007
Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906539
4 April 2006
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2616545
13 March 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2601314
3 February 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2578277
26 October 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2522583
20 June 2005
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2396885
5 April 2005
Annual Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2326482
30 June 2004
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2116683
19 March 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1759104
5 March 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1746372
20 February 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1483905
14 April 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112036
5 March 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467737
6 January 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1384342
9 February 1999
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446728
13 January 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378256
29 April 1997
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437242
14 April 1997
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385972
11 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 186884
5 February 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1103715
27 January 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1102050
10 January 1997
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377914
2 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764745
15 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193474
5 January 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1398377
6 April 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150689
11 January 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355130
4 January 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1389959
29 December 1993
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1377108
4 January 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1139910
29 December 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1135900
30 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946004
31 December 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947631
15 January 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 927688
2 January 1991
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 921929
19 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241021
17 August 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 892503
11 April 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 890632
18 January 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891160
1 February 1988
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1326680
9 December 1986
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1330227
5 June 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285104
26 October 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271714
22 December 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273078
Lifesaving › Lifefloat › Float-free Link
Issued 2 May 2012
Resolved
Weak link does not have manufacture's label with CG approval series & rated capacity.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2012
Resolved 3 May 2012
Resolution: Installed new weak link.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 May 2012
Resolved
Alcohol test strips onboard are expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2012
Resolved 3 May 2012
Resolution: Provided evidence of new alcohol test strips onboard.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 2 May 2012
Resolved
Propulsion control shutdowns are not located at vessel's operating station.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 16 May 2012
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2011
Resolved
Vessel's stability letter has not been updated to reflect the new assumed average weight per person of 185 lbs as per 46 CFR 178.310 (a)(1). therefore, passengers have been limited to 34.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 December 2012
Resolution: Stability Addendum provided.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 12 April 2007
Resolved
Ensure overspeed device works.
Due 25 May 2007
Resolved 25 April 2007
Communications › Public Address System › Announcing Station
Issued 12 April 2007
Resolved
Provide public address system.
Due 25 May 2007
Resolved 25 April 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2007
Resolved
Provide working bilge alarm system.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2007
Resolved 25 April 2007
Construction/Loadline › Structures › Superstructure
Issued 12 April 2007
Resolved
Renew superstructure windows with safety glass.
Due 25 May 2007
Resolved 11 July 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 March 2006
Resolved
Master to ensure compliance with vessel's stability letter prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 13 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 March 2006
Resolved
Provide two BII dry chemical fire ext's for MPT, per endorsement on COI.
Action required: 705 - Other - as specified
Due 20 March 2006
Resolved 4 April 2006
Navigation › Piloting/Steering › Marine Charts
Issued 13 March 2006
Resolved
Provide current Navigtion charts of vessel's AOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2006
Resolved 4 April 2006
Resolution: Provided.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 June 2005
Resolved
Vessel found in overloaded condition, exceed max draft and max deck cargo VCG per stability letter dated 13MAR89. Master to ensure compliance with stability ltr prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2005
Resolved 20 June 2005
Electrical › Electric Supply System (service) › Cable
Issued 5 April 2005
Resolved
Install metal retaining straps on the walk in cooler refrigerant compressor power cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 5 April 2005
Resolution: completed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 5 April 2005
Resolved
Install closure device on the front cover for the main switch board and the port power panel in the generator space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 5 April 2005
Resolution: Closure devices installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2005
Resolved
Install guard on the galley stove light bulb.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 5 April 2005
Resolution: Installed guard.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 April 2005
Resolved
Remove extension cord serving as permanent wiring under the pilothouse console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 5 April 2005
Resolution: Proper marine cable installed.
Engineering › Fuel Oil Service System › Hose
Issued 5 April 2005
Resolved
Install chafing gear on the fuel oil lines for the port and starboard fuel oil hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 5 April 2005
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 1 July 2004
Resolved
Remove all oil from the engine room bilge.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 July 2004
Resolution: Crew removed all oil from engine room bilge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2004
Resolved
Properly secure cables for the port ship service generator.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 July 2004
Resolution: Inspected the securing of the port generator cables.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 July 2004
Resolved
Properly label emergency escape hatch for the engine room.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 July 2004
Resolution: Labeled engine room emergency escape hatch.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 June 2004
Resolved
Add exhaust lagging for both main diesel engines' exhaust piping.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 July 2004
Resolution: Inspected the installation of exhaust lagging on both main diesel engines'' exhaust.
Engineering › Fuel Oil Service System › Valve, Control
Issued 30 June 2004
Resolved
Properly label emergency remote fuel oil shut-off valves located on the main deck.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 July 2004
Resolution: Inspected the labeling of the emergeny fuel oil shut-off valves.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 June 2004
Resolved
Outside reinspection window.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 July 2004
Resolution: Conducted reinspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 March 2003
Resolved
Paint navigation light screens flat black as required by 72 COLREGS and 33 CFR Part 84. LEGACY COMPONENT DESC: Navigation Lights
Due 19 April 2003
Resolved 5 April 2005
Resolution: vessel repainted during drydock.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 March 2003
Resolved
Renew emergency escape hatch gasket and prove watertight to the satisfaction o fthe attending marine inspector. See
46 CFR 179.360. LEGACY COMPONENT DESC: Scuttle
Due 19 April 2003
Resolved 5 April 2005
Resolution: hatch replaced during drydock.
Fire Fighting › Fire Main
Issued 19 March 2003
Resolved
Renew starboard firemain hydrant shutoff valve and prove operational to the satisfaction of the attending marine inspector.
See 46 CFR 181.310. LEGACY COMPONENT DESC: Valves
Condition: Improper/Lack of Maintenance
Due 19 March 2003
Resolved 19 March 2003
Resolution: Renewed during inspection, new valve installed and proven operational.
Engineering › Bilge Water Management System
Issued 5 March 2003
Resolved
Repair Frozen Reach Rod in Forepeake. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 19 March 2003
Resolved 19 March 2003
Resolution: Reach Rod repaired and found operational.
Deck/Cargo › Holds/Tanks
Issued 5 March 2003
Resolved
Repair all hatch chains throughout vessel. LEGACY COMPONENT DESC: Hatch Chains
Due 12 March 2003
Resolved 12 March 2003
Resolution: All hatch chains were repaired satisfactorely.
Deck/Cargo › Ballast
Issued 5 March 2003
Resolved
Remove old sounding tubes in port & starboard void tank (old ballast tank). LEGACY COMPONENT DESC: void tanks
Due 12 March 2003
Resolved 12 March 2003
Resolution: Sounding tubes removed from tank.
Lifesaving › Lifebuoys
Issued 5 March 2003
Resolved
Replace Life Ring on port side of foscle.
Due 12 March 2003
Resolved 12 March 2003
Resolution: Life ring replaced on foscle.
Engineering › Fuel Oil Service System › Piping
Issued 5 March 2003
Resolved
Repair/replace caps on Fuel Oil Sounding Tubes, port & starboard (aft end of foscle).
Due 12 March 2003
Resolved 12 March 2003
Resolution: Caps replaced on port & starboard Fuel Oil Sounding Tubes.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 5 March 2003
Resolved
Repair sewage tank pipe in generator room.
Due 19 March 2003
Resolved 12 March 2003
Resolution: Sewage pipe was repaired.
Accommodation/Occupational Safety › Ventilation
Issued 5 March 2003
Resolved
Repair Air Intake in Generator room. LEGACY COMPONENT DESC: Generator room
Due 12 March 2003
Resolved 12 March 2003
Resolution: Air Intake was repaired.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 5 March 2003
Resolved
Replace guards on sight glass on generators. LEGACY COMPONENT DESC: Sight Glass
Due 12 March 2003
Resolved 12 March 2003
Resolution: Sight glass guards were replaced.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 5 March 2003
Resolved
Cap Lub Oil lines (port & starboard) in Engine Room.
Due 19 March 2003
Resolved 19 March 2003
Resolution: Port & Starboard Lub Oil lines were capped.
Engineering › Fuel Oil Storage/Transfer System
Issued 5 March 2003
Resolved
Repair frozen fuel shut off valve on starboard side of Engine Room. LEGACY COMPONENT DESC: Shut off valve
Due 12 March 2003
Resolved 12 March 2003
Resolution: Frozen fuel shut off valve was repaired
Engineering › Fuel Oil Service System
Issued 5 March 2003
Resolved
Remove or recap drain line on starboard Racor filter. LEGACY COMPONENT DESC: Racor filter
Due 12 March 2003
Resolved 12 March 2003
Resolution: Caped drain line on starboard Racor filter.
Accommodation/Occupational Safety › Potable Water System
Issued 5 March 2003
Resolved
Repair potable water drain in in Engine Room. LEGACY COMPONENT DESC: Drain Line
Due 12 March 2003
Resolved 12 March 2003
Resolution: Potable water drain was repaired.
Engineering › Fuel Oil Service System
Issued 5 March 2003
Resolved
Provide chains for Fuel Oil containment plugs. LEGACY COMPONENT DESC: containment plugs
Due 12 March 2003
Resolved 19 March 2003
Resolution: Chains were obtained for Fuel Oil containment plugs.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 March 2003
Resolved
Repair broken ladder in #2 void portside. LEGACY COMPONENT DESC: Broken ladder
Due 19 March 2003
Resolved 19 March 2003
Resolution: Ladder in #2 Void portside was repaired.
Construction/Loadline › Structures
Issued 5 March 2003
Resolved
Repair cracked weld as marked in port wrap tank and swash bukhead. LEGACY COMPONENT DESC: Swash Bulkhead
Due 19 March 2003
Resolved 19 March 2003
Resolution: All cracks repaired.
Navigation › Piloting/Steering
Issued 20 February 2002
Resolved
Rudder posts missing cotter pins.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Cotter pins re-inserted.
Deck/Cargo › Mooring/Anchoring
Issued 20 February 2002
Resolved
Gearbox for anchoring system inoperable.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: New gearbox ordered and installed.
Lifesaving
Issued 20 February 2002
Resolved
EPIRB battery had expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: Technician called and new battery installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 February 2002
Resolved
Sewage discharge line needed locking system to prevent unauthorized discharge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: Sewage discharge valve fitted with lock.
Fire Fighting › Fire Hydrants
Issued 20 February 2002
Resolved
All fire stations needed spanner wrenches.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: Spanner wrenches provided.
Electrical
Issued 6 January 2000
Resolved
Prove proper operation of the starboard generator.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Engineering
Issued 27 January 1997
Resolved
THE VESSEL MUST HAVE A RELIABLE MEANS FOR SHUTTING DOWN A PROPULSION ENGINEAT THE MAIN PILOTHOUSE CONTROL STATION WHICH IS INDEPENDENT OF THE ENGINE'SSPEED CONTROL AS PER 46 CFR 184.620 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Engineering
Issued 10 January 1997
Resolved
TACHOMETER ATTACHED TO PORT GENERATOR INOPERATIVE. REPAIR OR REPLACE AND PERFORM OVERSPEED TRIP TEST PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Engineering
Issued 10 January 1997
Resolved
INSTALL TACHOMETER AND AMPERAGE METER ON STARBOARD GENERATOR AND PERFORM OVERSPEED TRIP TEST PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Navigation
Issued 4 January 1995
Resolved
PROVIDE ON BOARD A MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Construction/Loadline
Issued 4 January 1995
Resolved
CONDUCT A CREDIT DRYDOCK EXAM PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Documentation
Issued 2 January 1991
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION STICKER FOR ANNUAL ENDORSEMENT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 January 1991
Resolved 2 January 1991