Records from 2005 to 2026. Most recent: inspection, 11 May 2026.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 March 2025
Resolved
If, during an internal structural, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Make repairs called out in ABS/USCG worklist.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 15 May 2025
Resolution: All repairs made, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2025
Resolved
Electric installations on vessels must ensure Protection of passengers, crew, other persons, and the vessel from electrical hazards. MI's identified holes in the back of the High Voltage transfer cabinet cover plates that need repair/replacement within 30 days or during upcoming dry dock whichever is sooner.
Action required: 705 - Other - as specified
Resolved 15 May 2025
Resolution: Cabined renewed all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 May 2024
Resolved
Components are listed by a nationally recognized testing laboratory (NRTL) as that term is defined in 46 CFR 161.002-2, and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance. Smoke detector in the galley was missing the required battery. New battery installed.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 30 May 2024
Resolved 30 May 2024
Resolution: New batteries installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2023
Resolved
Fire pumps may be used for other purposes provided at least one of the required pumps is kept available for use on the fire system at all times. The fire pump designated as “available for use on the fire system at all times” was inoperable. Prior to departure, repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2023
Resolved 23 May 2023
Resolution: Fire pump operational test satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 May 2023
Resolved
Each liferaft or group of liferafts must be arranged for float-free launching. The arrangement must ensure that the liferaft or liferafts, when released and inflated, are not dragged under by the sinking vessel. PORT and STBD (starboard) liferafts were permanently secured to the vessel. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 May 2023
Resolved 22 May 2023
Resolution: Port and STBD liferafts installed & attached correctly on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 May 2023
Resolved
The installation of all systems of an electrical engineering…nature…shall be in accordance with the details of design, construction, and installation of subchapter J (Electrical Engineering). Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Both generators dropped offline and shutdown during testing of reverse power. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 23 May 2023
Resolution: Vessel demonstrated proper operation of reverse-power; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023
Resolved
The installation of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. Each lighting fixture must be on a lighting branch circuit. External light on the Emergency Generator Room has a spliced lighting cable spliced into a 120V Receptacle. Repair or replace to the satisfaction of USCG Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 23 May 2023
Resolution: 120V receptile has been removed and covered to operate as junction box.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2023
Resolved
The installation of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. Emergency Generator Room has electrical penetration through bulkhead with improper RoxTec installation. Repair or replace to the satisfaction of USCG Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 12 June 2023
Resolution: New RoxTec electrical penetration installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 May 2023
Resolved
The inspection shall be such as to ensure that the workmanship of all parts of the vessel and its equipment is in all respects satisfactory… Emergency escape hatch leading to the Lower Pump Room cannot be secured properly. Repair or replace to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 23 May 2023
Resolution: Vessel crew demonstrated proper operation of emergency escape hatch.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 22 May 2023
Resolved
At each inspection for certification and periodic inspection, the inspector shall examine the vessel to determine that it meets the vessel design and equipment requirements for pollution prevention in 33 CFR part 155, subpart B. Standard Discharge Connection is installed on wrong fitting and is corroded / wasted. Repair or replace to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 5 June 2023
Resolution: Vessel provided documenttion for proper standard discharge connection.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 24 January 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regards to the hull, machinery or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspections.
Vessel is dry dock and has work list items to complete.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 28 February 2023
Resolution: Vessel completed Dry dock and repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 January 2023
Resolved
(a) Except as provided in paragraphs (b) through (g) of this section, each vessel must undergo drydock, internal structural, and cargo tank internal examinations as follows: (1) Except under paragraph (a)(2) of this section, vessels that operate in salt water must be examined in accordance with the intervals set forth in Table 91.40-3(a) of this section. Where Table 91.40-3(a) indicates a 2.5 year examination interval, it means a vessel must undergo two examinations within any five year period. No more than three years may elapse between any two examinations. Subject vessel is past due drydock extension date of 29DEC22.
Vessel is authorized for one time transit from Gulf Copper in Galveston, TX to Bollinger Ship Yard in Morgan City, LA. VSL is prohibited from commercial activity until dry dock inspection is completed.
***Action 15.c is articulated to mean to rectify deficiency upon arrival to Morgan City, LA.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 12 January 2023
Resolved 28 February 2023
Resolution: Credit DD/ISE complete.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 November 2022
Resolved
Each fuel oil tank with at least one side integral to the vessel's hull and located within the hull (“integral fuel oil tank”) is subject to inspection as provided in this section. Fuel tank had a small pinhole, allowing fuel to discharge into bilge. Reinforce temporary repairs and make permanent repairs to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2022
Resolution: Vessel has made all necessary repairs to integral fuel oil tank to the satisfaction of the Coast Guard Marine Inspector and to ABS.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 October 2022
Resolved
In General, compliance with the standards established by the American Bureau of Shipping will be considered as satisfactory efficiency of the vessel. Vessel made a temporary repair of a 5" x 1" with a cement box 24”
length x 12” width x 4” high made out of ½” thickness steel plate and welded to the bottom shell. During the temporary repair inspector noted significant wastage up to 40% via UT scan around the damage. Repair to the satisfaction of the Coast Guard Marine Inspection at next available dry dock.
46 CFR 92.01-10
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 28 February 2023
Resolution: Credit DD/ISE complete.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 October 2022
Resolved
In General, compliance with the standards established by the American Bureau of Shipping will be considered as satisfactory evidence of the structural efficiency of the vessel. Vessel reported a 5" x 1" hole in the bottom of the stbd storage area, a temporary repair of epoxy and wood has been applied. Repair to the satisfaction of the USCG Marine Inspector. Vessel is restricted from movement until deficiency is rectified.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 7 October 2022
Resolved 19 October 2022
Resolution: Vessel installed of a cement box 24” length x 12” width x 4” high made out of ½” thickness steel plate and welded to the bottom shell.
14 - Pollution Prevention › 141 - MARPOL Annex I › Accidental oil outflow performance
Issued 3 October 2022
Resolved
In the event of an accident to a boiler, unfired pressure vessel, or machinery tending to render the further use of the item unsafe until repairs are made, or if by ordinary wear such items become unsafe, a report shall be made, by the by the Chief Engineer immediately to the Officer in Charge, Marine Inspection. Received report that the vessel's ladder winch system failed resulting in a gear box oil leak and pollution incident. Repair or replace system to the satisfaction of an attending Marine Inspector prior to conducting dredge operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 October 2022
Resolved 20 October 2022
Resolution: Rebuilt gear box. performed operational test.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 February 2022
Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery spaces, galleys, main pantries and storerooms, other than small service lockers, shall be of “A” Class construction. The fire door between the E/R and ECR does not properly close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 15 March 2022
Resolution: Boudary door's latching mechanism was replace. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 February 2022
Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery spaces, galleys, main pantries and storerooms, other than small service lockers, shall be of “A” Class construction. The E/R cable penetrations behind the paneling in the main stairwell does not stop the spread of fire / smoke.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 15 March 2022
Resolution: Cable penetraions were sealed off using appropriate fire stop foam. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 22 February 2022
Resolved
Each launching station, or each two adjacent launching stations, must have an embarkation ladder as follows. The fender / liferaft embarkation ladder on the port side is being replaced due to damage and is not on board.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 15 March 2022
Resolution: New embarkation ladder was installed on the port side. Deficiency rectified.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 22 February 2022
Resolved
Box receptacle should be provided with covers. Receptacle outlet box facing the diesel transfer station is missing a cover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 1 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 February 2022
Resolved
Each fire pump must be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approximately 50 p.s.i. The emergency fire pump was inop due to loose battery terminal connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2022
Resolved 22 February 2022
Resolution: Crew identified and corrected loose terminal connections on starting battery.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 22 February 2022
Resolved
General emergency alarm signal must be located in passenger and crew quarters areas where they can alert persons in spaces where those persons may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting. The general alarm was inop in main stairwell and ECR
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 February 2022
Resolved 22 February 2022
Resolution: Crew immediately fixed inop general alarm bells.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 December 2020
Resolved
The emergency power source must meet table 112.05-5(a) and have the capacity to supply all loads that are simultaneously connected to it, except a load on a bus-tie to the main switchboard or non-required loads that are connected in accordance with §112.05-1(c). Ship’s EDG is currently inoperable.
Action required: 30 - Ship detained
Resolved 2 December 2020
Resolution: Technician's were onboard and were able to get the EDG back up and working. Conducted a blackout test. Test SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 1 December 2020
Resolved
Each pump must be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approximately 50 p.s.i.. There are two seals leaking excessively resulting in inadequate pressure.
Action required: 30 - Ship detained
Resolved 2 December 2020
Resolution: Emergency Fire Pump glands were repacked and the leaks were stopped. E-Fire Pump is working properly and supplying required output.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 December 2020
Resolved
Each fireman's outfit must consist of one self-contained breathing apparatus, one lifeline with a belt or a suitable harness, one flashlight, one flame safety lamp, one rigid helmet, boots and gloves, protective clothing, and one fire axe. Both Fireman’s Outfits are missing tending lines and fire axes.
Action required: 30 - Ship detained
Resolved 2 December 2020
Resolution: Vessel has ordered the FFE tending lines and Fire axes to replace the missing items from both sets. Ship is using vessel's extra Fire Axes and has temporary tending lines in place.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 December 2020
Resolved
There shall be at least two means of escape from all general areas where the crew may be quartered or normally employed. At least one of these two means of escape shall be independent of watertight doors. The emergency escape hatch in the pump room overhead is not able to be opened (seized), resulting in only one means of escape from the space.
Action required: 30 - Ship detained
Resolved 2 December 2020
Resolution: Emergency escape hatch has been maintenanced and is in good working condition.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 December 2020
Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this Subchapter is provided, maintained, and replaced as indicated. The fire hose nozzles bails are seized and prevent the use of the fire hose.
Action required: 30 - Ship detained
Resolved 2 December 2020
Resolution: Fire hose nozzles have been maintenanced and are all in good working condition.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 1 December 2020
Resolved
General emergency alarm signal must be located in passenger and crew quarters areas where they can alert persons in spaces where those persons may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting. General alarm light and bell are inoperable in the pump room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Electrician repaired GA light and audible alarm. Tested,sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2020
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. There is excessive oil accumulation under the port/starboard SSDGs, oil soaked rags in bilges, HPU winch is leaking oil, HPU Aux #3 is leaking oil, diesel fuel is in improper containers, and there is excess fuel in the Racor fuel filter bowls, resulting in an extreme fire hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: All oily rags and oil accumulation in bilges was wiped up/removed. Steps have been arranged for watchstanders to continue to wipe up throughout the day. Vendors have been arranged to come out and make repairs to leaking equipment.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 December 2020
Resolved
The master of the vessel for which a load line certificate has been issued shall be responsible for the maintenance of such certificate on board such vessel and for compliance with its terms and conditions. #1 Port/STBD Void, #2 Port/STBD void, #3 Port/STBD void, and void aft of generators are all missing hardware, making them not in compliance with the load line and allowing for potential downflooding.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 December 2020
Resolution: Missing hardware has been installed on all voids identified during the inspection. SAT
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 December 2020
Resolved
Ceilings, linings, and insulation, including pipe and duct laggings, shall be of approved incombustible materials. Wiring and cable runs do not meet fire protection standards for bulkhead penetrations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2020
Resolution: Fire stop has been put into place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2020
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. Three out of four self-igniting lights on lifebuoys are inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: The crew renewed the water light batteries, test sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 December 2020
Resolved
At each inspection for certification and periodic inspection, the inspector will check fire-extinguishing equipment with the following tests and inspections: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Spare portable fire extinguishers are not stowed in proper locations or in proper brackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: The extinguishers not in brackets were spares that the crew puts out for additional safety. The crew will label extinguishers "Spares" and ensure they are secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 December 2020
Resolved
Electric installations on vessels must ensure Protection of passengers, crew, other persons, and the vessel from electrical hazards. Light fixture cover is missing in pump room, distribution panel is missing face plate, dead end wire behind air receivers, and open wiring enclosures near Port MDE and #3 Auxiliary HPO.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 5 January 2021
Resolution: All items were repaired and or replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 1 December 2020
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deems necessary to be assured of the safety and seaworthiness of the vessel. Clutter in main engine room starboard side, makes eyewash and shower station inaccessible.
Action required: 705 - Other - as specified
Resolved 2 December 2020
Resolution: The crew removed the clutter so eyewash/shower are accessible.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 December 2020
Resolved
Pipe, tubing, pipe joining fittings, and piping system components, shall meet material and standard requirements of subpart 56.60. Numerous valve handles on Raw Water piping are missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2020
Resolution: All valve handles have been replaced.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 1 December 2020
Resolved
The master or person in charge of a ship to which this section applies shall ensure that a written record is maintained on the ship of each of the following garbage discharge or disposal operations: (1) Discharge to a reception facility or to another ship; (2) Incineration on the ship; (3) Discharge into the sea; and/or (4) Accidental or other exceptional discharges. No entries have been made in the Garbage Record Book.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2020
Resolution: Garbage record book is now being logged in on a daily basis.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 11 February 2019
Resolved
Remove old piping meant for OWS system and permanently cap end of piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2019
Resolved 19 February 2019
Resolution: Suspect piping was removed and capped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2019
Resolved
Weld or permanently secure brackets holding verticle deck drainage piping in place.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2019
Resolved 19 February 2019
Resolution: Brackets were secured in place.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2019
Resolved
Install missing electrical panel door and blanks to electrical panel in the spud room and electrical boxes in the electrical room adjacent to the galley.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2019
Resolved 19 February 2019
Resolution: Panel and blanks were installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2019
Resolved
Replace broken window in the spud room.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2019
Resolved 19 February 2019
Resolution: Window was replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2019
Resolved
Fix hydraulic leaks to fittings and equipment in the spud room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2019
Resolved 19 February 2019
Resolution: Fittings were tightened and secured. Leaks were stopped or minimized.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 22 February 2018
Resolved
Provide properly working impulse line throwing apparatus.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel provided pictures of new line throwing apparatuses.
Construction/Loadline › Markings › Load Line Mark
Issued 22 February 2018
Resolved
Paint deck reference line of contrasting color.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel painted reference line
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 February 2018
Resolved
Provide blank in electrical box EP1 in electrical room in galley.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel installed new blank box.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 February 2018
Resolved
Properly adjust fire door leading into galley from the outside. Door does not latch by itself.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel adjusted fire door.
Fire Fighting › Ventilation Systems › Ducts
Issued 22 February 2018
Resolved
Stbd side #1&2, Port Aft, & fwd mid blower vents missing several bolts. Provide missing bolt/nuts.
Due 22 March 2018
Resolved 20 March 2018
Resolution: New fasteners installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 22 February 2018
Resolved
STBD #2 blower vent missing securing bolt for closure lid.
Due 22 March 2018
Resolved 20 March 2018
Resolution: New securing bolts installed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 22 February 2018
Resolved
Properly clean galley vent damper.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vent damper cleaned.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 22 February 2018
Resolved
Lube oil level gauge missing guard and shall be made of fire resistant material. Located in E-Gen room.
Due 22 March 2018
Resolved 20 March 2018
Resolution: guards installed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 February 2018
Resolved
Properly secure PFD locker located IVO STBD side muster area.
Due 22 March 2018
Resolved 20 March 2018
Resolution: PFD storage box secured.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 22 February 2018
Resolved
Repair leaking shaft seal, suction valve, discharge pipe bracket and minor exhaust leak IWO fire pump.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel completed all repairs to fire pump.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 22 February 2018
Resolved
Make scuttle in C6 watertight.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel tightened scuttle.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 February 2018
Resolved
Properly secure all loose gear throughout the vessel to include hydraulic tank.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel installed permanent brackets for hydraulic tank.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 22 February 2018
Resolved
Provide parameters and test all shutdown/alarms for engines and ensure they are within parameters.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel verified and completed all engine alarms and shutdowns.
Fire Fighting › Grease Extraction Hood › General
Issued 22 February 2018
Resolved
Provide proper fusible link IWO galley hood. Should be 212F and not 360F.
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel installed correct fusible link.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 February 2017
Resolved
Remove excess oil from the fwd hydraulic room
Action required: 66 - Prior to drilling or production operations
Due 18 February 2017
Resolved 23 February 2017
Resolution: Vessel cleaned up oil and provided pictures.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 February 2017
Resolved
Clean excess oil from bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2017
Resolved 23 February 2017
Resolution: Vessel cleaned bilge and provided pictures.
Engineering › Reduction Gearing/Clutches › Seal
Issued 18 February 2017
Resolved
Repair all leaking unions and leaks on gear oil piping for the main pump engines and thrust bearing.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel sealed unions and leaks, pictures were provided.
Fire Fighting › Grease Extraction Hood › General
Issued 18 February 2017
Resolved
Provide an inspection certificate for the range hood fire extinguishing system prior to using deep fat fryer.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 6 March 2017
Resolution: Vessel provided inspection report.
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 18 February 2017
Resolved
Install cover for junction box on stbd engine and port engine.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel installed covers, pictures were provided.
Engineering › Fuel Oil Service System › Hose
Issued 18 February 2017
Resolved
Install fire sleeves on all fuel hoses.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 6 March 2017
Resolution: Vessel provided pictures of installed fire sleeves on all fuel hoses.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 February 2017
Resolved
Remove exposed cable under STBD Gen.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Cable removed.
Engineering › Lubricating Oil Service System › Hose
Issued 18 February 2017
Resolved
Replace chaffed hose on the STBD pump engine.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel replaced hose.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 18 February 2017
Resolved
Repair leaks on on the following pumps, Emergency fire pump, #1 and #2 SW cooling pumps and ladder pumps.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel replaced seals.
Construction/Loadline › Penetrations › Gasket
Issued 18 February 2017
Resolved
Replace gaskets on all escape hatches and WTH in all pump rooms.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel replaced gaskets.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 February 2017
Resolved
Repair navigation light panel alarm and all navigation lights.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 6 March 2017
Resolution: Vessel installed a new circuit board for navigation light alarm panel and installed new lights.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 February 2017
Resolved
Install correct bracket for fire extinguisher on bridge.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel instealled correct bracket.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 February 2017
Resolved
Install insulation where missing in galley electrical room next to the GA box.
Due 18 March 2017
Resolved 6 March 2017
Resolution: Vessel installed a cover for all exposed wiring.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 18 February 2017
Resolved
Replace trash can in galley with a fire retardant one.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Trash can replaced.
Fire Fighting › Fire Hoses › Material
Issued 18 February 2017
Resolved
Replace the aft fire hoses with approved fire hoses.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel installed two approved fire hoses.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 February 2017
Resolved
Secure lifejacket storage box.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel secured the PFD storage box.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 February 2017
Resolved
Repair grease hose on main spud RAM stbd side.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 23 February 2017
Resolution: Vessel replaced hose.
Lifesaving › Lifebuoys › Serviceable
Issued 18 February 2017
Resolved
Replace stbd life ring and repair light on the prt fwd life ring.
Due 18 March 2017
Resolved 24 March 2017
Resolution: Vessel replaced ring and repaired light.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 18 February 2017
Resolved
Port side containment needs to be enlarged to ensure full containment.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 28 February 2017
Resolution: Vessel extending piping to ensure it would be contained if it ever leaked.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 25 October 2016
Resolved
Issued 835 extending liferaft servicing date for 5 months or until next scheduled vessel exam whichever comes first as per 46 CFR 199.190(g).
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 18 February 2017