Records from 1992 to 2026. Most recent: inspection, 6 May 2026.
Documentation record
Registered dimensions (L × B × D)53.9 ft × 22.0 ft × 8.1 ft
Registered tonnagegross 73 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS INC · BAYOU BLUE, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNYACK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 7 August 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
6 May 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8368078
3 April 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8117790
19 November 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7098544
22 May 2017
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6163278
6 September 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4976170
5 September 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4996513
7 July 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4915508
22 July 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4387902
16 June 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4349040
8 August 2011
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4120402
11 July 2011
Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4080308
10 March 2008
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3206116
16 April 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2049456
11 March 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2022812
23 February 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2011580
15 May 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1617164
14 September 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 122051
15 March 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 86422
8 October 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 51541
20 May 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 147210
29 August 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 99588
31 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 350123
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 May 2026
Resolved
To qualify for a medical certificate, a mariner must provide evidence of meeting the medical and physical standards in this section on a CG-719-K or CG-719-K/E, or as directed by the Coast Guard. The Coast Guard retains final authority for determining whether a mariner is medically and physically qualified. Columns 2 through 5 of Table 1 to paragraph (a) of this section provide the specific exam, test, or demonstrations required to obtain the corresponding credential listed in column 1. Master medical license expired. Provide proof of valid medical certificate for Master that was present during COI Inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2026
Resolution: Employee no longer captain of vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2026
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists . The following alarms must be provided: (5) High bilge levels.
Action required: 10 - Deficiency Rectified
Resolved 21 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2026
Resolved
All pressure vessels must have the MAWP indicated by a
stamp, nameplate, or other means visible to the crew.
Relief valves must be tested in accordance with 143.245
Pressure vessel not marked with no proof of testing.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 30 May 2026
Resolution: see word doc.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 May 2026
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. MI found semi-portable fire extinguishers with wasted metal clamps rendering the hose not fully accessible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
Resolution: Picture recived.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 May 2026
Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. MI found first aid cabinet missing required items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 May 2026
Resolved
No marine employer may engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Could not provide proof of new crew members enrolled in chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 26 May 2026
Resolution: rc'd proof of enrollemnt for all employees
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 May 2026
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
Resolution: Received plan.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 May 2025
Resolved
The owner or managing operator of an existing vessel not operating under a stability document must be able to show at least one of the following: Satisfactory stability assessment. Vessel conducted an assessment. Waiting on official report. Provide document prior to operating on a Coastwise route.
46 CFR 144.300(b)(3)
Action required: 705 - Other - as specified
Resolved 8 May 2025
Resolution: Received official report for Stability Assessment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Exposed plug wires in galley.
46 CFR 143.400(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 8 May 2025
Resolution: Received photo for electrical plug outlet ant wires properly installed.