Records from 1994 to 2025. Most recent: inspection, 29 August 2025.
Inspection history · 58
29 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8220511
23 July 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7964776
5 February 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7860549
7 July 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7736324
7 July 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7739655
30 June 2021
Initial Certification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7240747
18 August 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7036011
18 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7036623
12 August 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7030794
26 May 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6960609
3 February 2020
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6903486
30 January 2020
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6899854
30 January 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6901530
27 January 2020
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6896649
27 January 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6897588
8 June 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6713738
30 November 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6050044
6 February 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5811963
9 September 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4980094
7 July 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4915508
4 June 2014
Industry Initiated Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4846370
9 May 2014
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4854573
1 May 2014
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4849037
5 March 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4811685
7 December 2011
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 4205043
4 December 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4201828
7 September 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4139394
14 February 2011
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3944805
27 August 2009
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3581660
6 June 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3500279
1 October 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3340062
1 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3324424
10 November 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2835363
11 May 2005
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 3702737
8 April 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2040230
4 February 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1742531
8 December 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1474169
3 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074366
12 January 2000
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376019
17 March 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 765541
25 February 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 81015
25 February 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 198728
6 July 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 673460
26 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 673456
23 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 214088
11 June 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 24756
4 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 73100
24 January 1997
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1101401
30 July 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 61806
5 June 1996
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 872204
25 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 651932
18 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 63981
18 January 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190288
24 November 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 651933
25 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 651935
11 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 82454
31 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 194890
16 June 1994
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 683103
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel reported a loss and recovery of its on-line generator.
TPO to provide report with causal analysis and attestation to vessel's fitness to resume operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2025
Resolution: Root cause was faulty battery bank charger. Bank charger replaced, TPO attested to proper operation and functional generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operations. The cessel has temporarily replaced check valves with ball valves on the steering system. Repair to the satisfaction of RO
46CFR143.205(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 11 February 2020
Resolution: Steering system ball vlv removed and proper check vlvs installed as per CG-835V. Steering test SAT.
Accommodation/Occupational Safety
Issued 5 June 1996
Resolved
VSL'S APPROVED TYPE II MARINE SANITATION DEVICE NOT WORKING PROPERLY. INSTRUCTED MASTER TO KEEP OVERBOARD VALVE CLOSED UNTIL PERMANENT REPAIRS ARE MADE TO MSD.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 5 June 1996
Resolved
VSL HAS 8" BELL & SHOULD HAVE 12" BELL.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 5 June 1996
Resolved
VSL'S LIFERINGS HAVE NO RETROREFLECTIVE TAPE ON THEM.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 18 January 1996
Resolved
Provide operable marine sanitation device.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Unknown
Issued 18 January 1996
Resolved
Prove that vessel is fit for service intended by providing necessary stability calculations to [name withheld].
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996