Records from 1990 to 2008. Most recent: inspection, 27 May 2008.
Inspection history · 152
27 May 2008
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3196692
15 May 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3200903
28 January 2008
MARPOL Annex V Examination · COC-CVE Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3065968
26 November 2007
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3106503
2 October 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3071297
7 July 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3021862
29 January 2007
COC-CVE Annual · ISPS II Exam · STCW 95 Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2857984
7 August 2006
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-CVE Quarterly
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2739273
21 July 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2740324
8 May 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2645747
6 May 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2643785
5 May 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2646754
22 February 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2587768
21 February 2006
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2576595
8 February 2006
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · COC-CVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2581613
2 November 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2527773
18 October 2005
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2517049
18 October 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2518601
11 October 2005
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2512790
10 October 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2541719
8 August 2005
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · COC-CVE Quarterly
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2452448
25 July 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2451134
23 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2440845
22 May 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2426440
25 April 2005
Deficiency Check · Administrative Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2342265
7 February 2005
Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2286838
12 January 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2273420
12 January 2005
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2273596
11 January 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2273445
25 October 2004
COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2386010
23 July 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2142362
29 June 2004
ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2115258
13 February 2004
Passenger/Freight Vessel Examination · MTSA/ISPS Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2006339
3 February 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1999622
15 October 2003
Examination of Repairs
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1929907
17 September 2003
Quarterly Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1912813
27 June 2003
Quarterly Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1822321
11 June 2003
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1815022
9 May 2003
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1789886
24 April 2003
Security Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1779933
15 April 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1774476
14 April 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1773748
26 March 2003
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1759683
20 February 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1749929
18 December 2002
Quarterly Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1720404
4 September 2002
Control Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1664055
11 June 2002
Control Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1629322
10 May 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1616325
9 May 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1628348
2 May 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1617285
20 February 2002
Quarterly Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1486657
29 November 2001
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1479270
26 October 2001
Port Security Assessment
Type not classified · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 554963
11 October 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 184410
12 September 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 9186
9 September 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 294055
9 September 2001
Control Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1075514
28 July 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 141244
9 July 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291773
6 June 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 139410
6 June 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 290874
9 May 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 30226
23 April 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 640347
2 April 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 288581
21 March 2001
Quarterly Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1064845
13 March 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 288111
10 January 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 281971
10 January 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 286408
26 October 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283495
16 October 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282997
15 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282293
14 September 2000
Control Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1469315
17 July 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 279818
21 December 1999
Quarterly Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1472033
30 September 1999
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 431860
30 September 1999
Control Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1459547
14 August 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 89685
16 September 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 75136
6 September 1998
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1386343
8 August 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 802487
9 April 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11199
9 April 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 202044
9 April 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765290
26 August 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 459316
14 August 1997
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1446525
23 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106156
20 May 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1368242
19 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 400736
19 February 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441170
12 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 511467
24 November 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404271
6 November 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1363851
13 September 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1360642
15 August 1996
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1431665
13 August 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 145127
13 August 1996
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084788
12 August 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108100
23 May 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1363640
29 February 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421077
1 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 15067
5 December 1995
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457310
20 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 883499
7 September 1995
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1385538
25 August 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108913
25 August 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871946
22 August 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 688411
18 August 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 876062
11 August 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 37747
11 August 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874754
13 June 1995
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1407503
21 April 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 90153
18 April 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 45646
14 March 1995
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174362
11 January 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 106425
6 December 1994
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138754
6 September 1994
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 869188
14 July 1994
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1178936
22 March 1994
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1167948
14 December 1993
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 852244
14 September 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 361852
14 September 1993
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 835788
14 September 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165312
31 August 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1136676
14 July 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841249
15 June 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146446
19 April 1993
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149672
16 March 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146887
29 January 1993
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828828
2 January 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 29000
2 January 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 356132
17 December 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 963065
17 November 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 167650
20 October 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931621
6 October 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 353610
19 September 1992
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1269005
16 September 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 688412
15 September 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 354006
14 September 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 38533
14 August 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 667827
21 July 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261519
20 July 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 86890
19 May 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 102277
23 April 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 947830
4 February 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 44393
30 January 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 951312
18 October 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250016
4 October 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 667828
21 September 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1245292
6 August 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246544
23 April 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 912609
29 January 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916786
26 October 1990
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1223319
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 27 May 2008
Resolved
27APR2008: Vessel reported jacket water leak in the #1 main diesel engine and placing the engine into standby status to prevent further usage. Issued COTP Order 055-08 requiring vessel to complete cruise scheduled on 27APR2008 and suspend all future movement and remain dockside afterwards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2008
Resolution: 28APR2008: Received Class report attesting to satisfactory repairs and test of #1 Main Diesel Engine. Rescinded COTP Order no. 055-08
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 May 2008
No resolution recorded
Vessel must complete quarterly passenger ship safety exam prior to embarking passengers. 46CFR70.05-3 / 46CFR71.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2008 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 January 2008
Resolved
Fire door leading to the emergency generator room is not an A-0 boundary as classified in the structural fire protection plan dated May 11, 1990. Solas 60 Ch II Reg 40.
Action required: 705 - Other - as specified
Due 27 February 2008
Resolved 15 May 2008
Resolution: Recieved class report from Lloyd''s register attesting to the alteration of the A-0 fire door, it now meets structural requirements.
Fire Fighting › Means of Escape › Doorways
Issued 28 January 2008
Resolved
Counterweight on fire doors need to be adjusted for easier opening, and handles repositioned for easier use. Solas 60 Ch II Reg 38(e).
Action required: 705 - Other - as specified
Due 27 February 2008
Resolved 15 May 2008
Resolution: Received class report from [name withheld] attesting to the satisfactory operation of the door, after maintinance was performed by the crew.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 29 January 2007
Resolved
Several lifejackets had inoperable lights.
SOLAS 74 (2004 consolidated edition) III/22.3
LSA Code 2.2.3
Action required: 705 - Other - as specified
Due 26 February 2007
Resolved 26 February 2007
Resolution: Lights were replaced onsite with replacement lights they had onboard.
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 August 2006
Resolved
International Oil Pollution Prevention certificate does not have a maximum throughput quantity for the oily water separator. MARPOL 73/78 Annex I, Reg. 5 To the satisfaction of the Coast Guard
Due 7 September 2006
Resolved 21 August 2006
Resolution: Received updated IOPP certificate with correct information.
Engineering › Non-conventional Propulsion/Steering › Propeller Shaft (z-drive)
Issued 21 July 2006
Resolved
Vessel was issued COTP order 062-06 on 21Jul2006 due to the failure of the starboard shaft seal. As a result, this vessel shall have tug assistance during all transits in and out of the Port of Corpus Christi. Repairs must be completed to the satisfaction of the class society surveyor authorized to represent the flag state. The vessel will make permanent repairs at dry-dock in October 2006.
Action required: 705 - Other - as specified
Resolved 29 January 2007
Resolution: Vessel attended dry-dock in October of 2006, in which provided documentation verifying that the permanent repairs have been made and the requirement has been met.
Engineering › Diesel Engine (propulsion-reduction gear) › Camshaft
Issued 21 February 2006
Resolved
Issued COTP Order 014-06 dated 31Jan06 for an inoperable starboard engine. Vessel shall have escort tugs (1 or 2) to the pilot's satisfaction while transiting through the Port of Corpus Christi until a class survey report attesting to satisfactory repairs has been submitted to this office by 07Feb06.
07Feb06: Vessel requested an extension to the COTP order due to inability to complete repairs.
Action required: 705 - Other - as specified
Due 21 February 2006
Resolved 21 February 2006
Resolution: 22Feb06: Received a report from Lloyds attaining to the satisfactory repairs to starboard engine.;
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 8 February 2006
Resolved
Ruber support flange on flemming gear in #3 and #5 starbord lifeboats are wasted.
Action required: 705 - Other - as specified
Resolved 22 February 2006
Resolution: Received class report attesting to the satisfactory repairs. Rubber flanges now renewed with new material. Fleming gear now examined and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2006
Resolved
Light post for #5 lifeboat(starboard side) has exposed wiring.
Action required: 705 - Other - as specified
Resolved 22 February 2006
Resolution: Received report from class attesting to satisfactory repairs. "The steel pipe supporting the emergency lamp has now been cropped and renewed. Lamp now examined and found satisfactory."
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 18 October 2005
Resolved
Issued COTP order 169-05 on 18Oct05 which directed the TEXAS TREASURE to have a two tug escort when entering the Port of Corpus Christi and to provide a class society report attesting to the repairs of the port engine prior to leaving the port.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Resolution: Received class report dated 18OCT05 attesting proper operation of port engine.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 11 October 2005
Resolved
Issued COTP Order 166-05 dated 11Oct05 for an inoperable port engine. Vsl shall have 1 or 2 assist tugs with a total sufficient horsepower to safely transit 2 assist tugs during departure and entry into the Port of Corpus Christi and the pilots must be satisfied with the safety of the evolution. This order remains in effect until a class report attesting to the repair
Action required: 705 - Other - as specified
Resolved 14 October 2005
Resolution: Received class report attesting to satisfactory repair/operation of port main engine. COTP Order 166-05 rescinded on 14Oct04.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 August 2005
Resolved
Fire Station #C10 closure pin broken.
SOLAS 60 II/56
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received Class report attesting to replacement of the locking pin.
Construction/Loadline › Structures › Door
Issued 8 August 2005
Resolved
Exterior doors in the buffet room (boat deck) not closing properly and door handles broken. Aft starboard, Aft port & Starboard door.
ICLL (1966) Reg. 12
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received class report attesting to the repairs. Exterior doors now adjusted / overhauled as found necessary.
Construction/Loadline › Structures › Door
Issued 8 August 2005
Resolved
Exterior door in Officer's mess (bridge deck) nailed shut. Door shown on evacuation plan as emergency exit.
SOLAS 60 Ch. II-2 Reg. 68
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received class report attesting to replacement of exterior door and returning it to service as an emergency exit.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 8 August 2005
Resolved
Insulation is missing IWO penetrations in A-60 overhead of E/R Control Room (Three (3) penetrations)
SOLAS 60 II/36
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received Class report attesting to the installation of insulation where previously missing.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 August 2005
Resolved
Insulation is mising IWO former fire doors (now welded shut) at A-60 boundary around stairtowers on car deck IWO female accomodations.
SOLAS 60 II/36
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received class report attesting to the installation of insulation where previously missing.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2005
Resolved
Starboard main engine S/W discharge pipe is leaking.
ICLL 66 Reg. 22
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received class report attesting to the renewal of piping.
Engineering › Compressed Air System (control) › Piping
Issued 8 August 2005
Resolved
S/W discharge pipe for provision compressor is leaking in several locations.
ICLL 66 Reg. 22
Due 8 September 2005
Resolved 29 August 2005
Resolution: Received class report attesting to the renewal of piping.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 April 2005
Resolved
vessel was issued LOD to depart and enter the port of corpus Christi with an inoperable radar 33 CFR 164.35 (a)
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 26 April 2005
Resolution: Radio Holland USA boarded the Texas Treasure and repaired the primary radar on the 26 April 2005.
Primary radar up and running.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 7 February 2005
Resolved
Emergency lights BOA 18, BRD 24, L/B #4 embarkation and port aft sun deck not working. SOLAS 60 II/25
Action required: 705 - Other - as specified
Due 21 February 2005
Resolved 28 February 2005
Resolution: Emergency Lights are satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 February 2005
Resolved
Fire screen door #516 not closing properly. SOLAS 60 II/38
Action required: 705 - Other - as specified
Due 21 February 2005
Resolved 28 February 2005
Resolution: Fire screen door is closing properly.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 7 February 2005
Resolved
Hole in suction side pipe of emergency fire pump located in shaft alley #1 port side. SOLAS 60 II/56
Action required: 705 - Other - as specified
Due 10 February 2005
Resolved 28 February 2005
Resolution: Bilge pumping and piping arrangements for shaft alley1 2 and 3 now amended to as is and connected to main bilge /ballast line.
Engineering › Bilge Water Management System › Not Installed
Issued 7 February 2005
Resolved
Provide bilge pumping/piping arrangement for shaft alley #1, 2, and 3. SOLAS 60 II/18
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 28 February 2005
Resolution: provided bilge pumping/piping arrangment for shaft alley.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 7 February 2005
Resolved
Small fuel oil leak on #3 ship service generator transfer pump.
Action required: 705 - Other - as specified
Due 21 February 2005
Resolved 28 February 2005
Resolution: fuel leak repaired on #3 generator.
Electrical › Electric Generation Source (emergency) › Grounding Conductor
Issued 7 February 2005
Resolved
Emergency generator does not have grounding strap. SOLAS 60 II/27
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 28 February 2005
Resolution: new grounding strap provided.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 7 February 2005
Resolved
Electrical mat missing from rear of main switchboard in engineering control room. SOLAS 60 II/27
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 28 February 2005
Resolution: Electrical mat provided in engine control room.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 7 February 2005
Resolved
Provide fire extinguishers for main and auxiliary engine room per regulation 64. SOLAS 60 II/64 (h) (ii)
Action required: 705 - Other - as specified
Due 21 February 2005
Resolved 28 February 2005
Resolution: fire extinguishers provided for main auxiliary room.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 12 January 2005
Resolved
Issued COTP Order #005-05 dated 12Jan05 for inoperable starboard engine (Ports and Waterways Safety Act, 33 USC 1221 et seq, and the regs issued there under, 33 CFR 160.111) Vessel was restricted to pier until the CG has received a class report detailing successful repairs/testing prior to departure. COTP order #005-05 revised 13Jan directing vsl to have 2 assist tugs until sat repairs completed.
Action required: 705 - Other - as specified
Resolved 15 January 2005
Resolution: Received class report on 15Jan05 attesting to sat repair/operation of starboard engine.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 October 2004
Resolved
Other (Suspected of discharge Violation) due to OWS not functioning & discharge line full of oil, vessel suspected of discharging overboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2004
Resolved 27 October 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 October 2004
Resolved
Oily water separator not operating properly. Vessel's crew could not operate OWS. MARPOL 73/78 Annex I, Ch. 2, reg. 16.5
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 27 October 2004
Resolution: Oily Water Separator working properly
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 October 2004
Resolved
Automatic stopping device for OWS not operable. MARPOL 73/38 Annex I, Ch. II, Reg 16.5
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 27 October 2004
Resolution: Automatic stopping device working properly
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 25 October 2004
Resolved
Overboard discharge line from OWS full of oily water sludge. MARPOL 73/38 Annex I Ch. II reg. 9
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2004
Resolved 27 October 2004
Resolution: Overboard discharge line clean & free of oil
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 October 2004
Resolved
15 PPM alarm not operational. MARPOL 73/78 Annex I, Ch. II, reg. 16(5)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2004
Resolved 27 October 2004
Resolution: Alarm functioning properly
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 25 October 2004
Resolved
Bilge pumping system not functioning SOLAS 60, reg 18
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2004
Resolved 27 October 2004
Resolution: Bilge pumping system operational
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 October 2004
Resolved
Due to OWS onboard not capable of handling slops / sludge generated by vessel, blank or blind OWS or discharge pipe to ensure no overboard discharge. MARPOL 73/78 Annex I Ch. II, reg. 16.2
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2004
Resolved 27 October 2004
Resolution: Discharge line blanked
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 October 2004
Resolved
Due to OWS onboard not capable of handling slops / sludge generated by vessel, install OWS that is capable of handling generated slops/sludge
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 7 February 2005
Resolution: New OWS has been installed to satisfaction of class society.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 15 October 2003
Resolved
Portside main engine A-bank turbocharger rotor was damaged due to a broken valve guide passing into the turbocharger. Cylinder head was replaced while vessel was underway. Once engine was restarted noise in the turbocharger was noticed and the engine was secured waiting permenant repairs. LEGACY COMPONENT DESC: Turbocharger
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2003
Resolved 16 October 2003
Resolution: Rotor in turbocharger replaced and turbo overhauled. Engine test ran and recieved Class Surveyor report that permenant repairs had been made and found satisfactory.
Fire Fighting › Structural - A Class Divisions
Issued 27 June 2003
Resolved
Pipe for drain in vertical zone 3 fire zone through A-60 bulkhead not properly sealed. SOLAS 60 Reg 38. Class surveyor to verify proper repair.
Due 30 August 2003
Resolved 17 September 2003
Fire Fighting › Means of Escape
Issued 27 June 2003
Resolved
Emergency escape breathing devices in engine room unsat. SOLAS 74 Ch II-2 Reg 28/Reg 11. Temporary-replace with spare from repair lockers, permanent-replace prior to 04 JUL 03.
Due 4 July 2003
Resolved 1 July 2003
Resolution: EEBDs replaced.
Engineering › Steering Gear System
Issued 11 June 2003
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2003
Resolved 11 June 2003
Resolution: Received class report verifying the proper operation of the steering gear.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 May 2003
Resolved
Port main engine experience casualty to cylinder head and turbocharger on 04 May 2003. Vessel placed under COTP order to provide class verification of repairs and propery operation. LEGACY COMPONENT DESC: Turbocharger
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 May 2003
Resolved 13 May 2003
Resolution: Received class report attesting to the repairs and proper operation of the port main engine and turbo charger.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 20 February 2003
Resolved
Vsl was ordered to have 2 tugs assist while transiting thru the Port Aransas jetties and during all docking and undocking evolutions until the port engine turbocharger is repaired and the Coast Guard has rec'd class rpt attesting to it's proper operation.
Action required: 705 - Other - as specified
Resolved 26 February 2003
Resolution: Rec''d class rpt attesting to proper operation of turbocharger.
Engineering › Steering Gear System
Issued 4 September 2002
Resolved
Excessive oil leaks on steering gears with mechanic (portable) ventilation on stbd steering pump. SOLAS 60 Reg 30. Make repairs.
LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 18 September 2002
Resolved 18 December 2002
Resolution: Cleared to the satisfaction of Marine Inspector.
Pollution Prevention/Response › Prevention Equipment
Issued 4 September 2002
Resolved
MSDS discharge pump leaking. 33 CFR 159.57/MARPOL 73/78 Annex IV Reg 3. Make repairs. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 18 September 2002
Resolved 18 December 2002
Resolution: Cleared to the satisfaction of Marine Insector.
Navigation › Piloting/Steering
Issued 10 May 2002
Resolved
Inoperable steering gear.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2002
Resolution: Vessel attended by Lloyds, USCG and Rolls Royce tech. Steering system test satisfactory.
Navigation › Piloting/Steering
Issued 2 May 2002
Resolved
Inoperable steering gear.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2002
Resolution: Vessel attended by Lloyds, USCG and Rolls Royce tech. Steering test satisfactory.
Construction/Loadline › Hull
Issued 20 February 2002
Resolved
Hole with crack in Paint Locker on starboard side along frame.
ILLC 66 Annex I Reg 1/ SOLAS 74 Amend. Ch I Reg 11. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 22 February 2002
Resolution: Item Corrected.
Construction/Loadline › Structures
Issued 20 February 2002
Resolved
Paint locker door gasket wasted, with item 1. Fire Protection compromised.
SOLAS 74 Amend CH 1 Reg 11/ Ch II-2 Reg 37. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 22 February 2002
Resolved 22 February 2002
Resolution: Item Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 February 2002
Resolved
Numerous wires and piping still in place in fwd Engine room from Generator change-out.SOLAS 60 Reg 27/ SOLAS 74 AMEND Ch I Reg II. Remove all excess pipes and wiring.
Due 8 March 2002
Resolved 22 February 2002
Resolution: Item Corrected.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 20 February 2002
Resolved
Fix toilets in crew accomodation head in B deck 500 section. 33 USC 1221/ ILO 147.
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 22 February 2002
Resolution: Item Corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 20 February 2002
Resolved
Fix emergency light in starboard access to 600 section crew accomodation space. SOLAS 60 Reg 27.
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 22 February 2002
Resolution: Item Corrected.
Construction/Loadline
Issued 26 October 2001
Resolved
Bilges were to max level with holding tanks full.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Fire Fighting
Issued 26 October 2001
Resolved
Main fire pump and shaft excessive leaking. SOLAS 60 Reg 56.
Condition: Unknown
Due 26 December 2001
Resolved 27 October 2001
Resolution: Class surveyor attended vessel. Pump packing replaced and found satisfactory. Condition of Class imposed to provide a remanufactured pump shaft.
Electrical
Issued 26 October 2001
Resolved
Clean oil off #2 Ships service generator and deck plates. Repair or change valve cover gaskets on #2 Ships service generator prior to operation.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 26 October 2001
Resolved
Prove that Type II MSD system can be isolated and re-routed to main holdingtank or that Type II system functions properly IAW operating manual and proper chemicals on board and administered thru system properly. MARPOL 73/78 Annex IV Reg. 3.4 and 33CFR 159.
Condition: Unknown
Due 26 December 2001
Resolved 27 October 2001
Resolution: Class surveyor attended vessel. Noted temporary repairs made to piping system. System observed in operation and found satisfactory. Chemicals and manual found onboard. Condition of class imposed to complete permanent repairs.
Construction/Loadline
Issued 26 October 2001
Resolved
Prove bilge pump arrangement and capacity IAW SOLAS. SOLAS 60 Reg 18.
Condition: Unknown
Due 26 December 2001
Resolved 27 October 2001
Resolution: Class surveyor attended vessel and observed bilge pumps in operation. Found satisfactory.
Fire Fighting
Issued 26 October 2001
Resolved
Prove fire pumps capacity and arrangement IAW SOLAS. SOLAS 60 Reg 56.
Condition: Unknown
Due 26 December 2001
Resolved 27 October 2001
Resolution: Class surveyor attended vessel. Main and Auxiliary Fire Pumps tested using 2 firehoses on the Bridge Deck (Fore and Aft). Pumps provided required streams of water, examined locally and found satisfactory.
Fire Fighting
Issued 9 September 2001
Resolved
Fire detection panel indicates fault due to damaged manual pull box. Solas_x001C_74 CH-II Reg 2.
Condition: Unknown
Due 24 September 2001
Resolved 24 September 2001
Fire Fighting
Issued 9 September 2001
Resolved
Audible alarm for sprinkler on bridge inoperable. Solas 74 CH II-2 Reg 12.
Condition: Unknown
Due 14 September 2001
Resolved 24 September 2001
Electrical
Issued 9 September 2001
Resolved
Fuel leak on #4 Generator. Solas 74 CH-I Reg 11.
Condition: Unknown
Due 24 September 2001
Resolved 24 September 2001
Electrical
Issued 9 September 2001
Resolved
Salt water leak on L/O Cooler for #1 Generator. Solas 74 CH-1 Reg 11.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Electrical
Issued 6 June 2001
Resolved
NUMBER ONE GENERATOR TURBOCHARGER LEAKING OIL._x001C_ SOLAS 60, II/343
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 6 June 2001
Resolved
FWD MAIN DECK HATCH FOR BOW TRUSTER ACCESS LEAKING._x001C_ ILLC 66 REG.12
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Electrical
Issued 6 June 2001
Resolved
#4 GENERATOR FAILED DUE TO OVERLOAD.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 6 June 2001
Resolved
ACCESS DOORS TO ACCOMADATION ZONE 120 NOT WEATHER TIGHT. _x001C_ ILLC 66 REG. 12_x001C_
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Lifesaving
Issued 13 March 2001
Resolved
4 Liferafts failured during testing. Safe Manning/amount of passengers carried reduced until replacement rafts are on board._x001C_ SOLAS 60 Ch III_x001C_
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Engineering
Issued 16 October 2000
Resolved
Stbd main engine piston damaged due to casualty. Engine is ooc for repairs._x001C_ SOLAS 60 CHI/reg 11
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Lifesaving
Issued 15 September 2000
Resolved
Excessive lose gear-slot machines,gas cylinders, on car deck._x001C_ SOLAS 60CHI reg11
Condition: Unknown
Due 15 September 2000
Resolved 19 September 2000
Fire Fighting
Issued 15 September 2000
Resolved
Failed fire drill in main engine room conducted 13 September 2000._x001C_ SOLAS 60 ChIII reg 26
Condition: Unknown
Due 15 September 2000
Resolved 19 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Embarkation ladders for all life rafts/boats._x001C_ SOLAS 60 CHIII reg29
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Fire Fighting
Issued 15 September 2000
Resolved
Trash containers made of flamible materials (plastic)_x001C_ SOLAS 60 CHII reg34
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Electrical
Issued 15 September 2000
Resolved
Inadequate emergency lighting in galley area._x001C_ SOLAS 60 CHIII reg 38
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Engineering
Issued 15 September 2000
Resolved
Fuel oil purifier excessive leakage/greater than 3 gallons per hour._x001C_ SOLAS 60 CHI reg11
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Lifesaving
Issued 15 September 2000
Resolved
Provide statement from class society attesting to satisfaction of present lifesaving arrangements_x001C_ SOLAS 74 ChIII reg 20
Condition: Unknown
Due 14 October 2000
Resolved 3 October 2000
Fire Fighting
Issued 6 September 1998
Resolved
Prior to 08 October 1998, provide on board for review a copy of the vessel's fire fighting applicance & installation maintenance & operations manual.
Condition: Unknown
Due 6 September 1998
Resolved 6 September 1998
Fire Fighting
Issued 6 September 1998
Resolved
Prior to 08 October 1998, provide on board a "class" approved fire control plan.
Condition: Unknown
Due 6 September 1998
Resolved 6 September 1998
Lifesaving
Issued 6 September 1998
Resolved
Prior to departure, provide on board an additional 33 adult sized PFD's.
Condition: Unknown
Due 6 September 1998
Resolved 9 October 1998
Lifesaving
Issued 6 September 1998
Resolved
Prior to 08 Octobe 1998, provide on board for review a copy of the on boardlife-saving appliance maintenance manual.
Condition: Unknown
Due 6 September 1998
Resolved 6 September 1998
Lifesaving
Issued 6 September 1998
Resolved
Prior to departure, assign personnel on the Muster List to ensure the following FSDs are closed: 403, 413, 414, & 515.
Condition: Unknown
Due 6 September 1998
Resolved 9 October 1998
Lifesaving
Issued 6 September 1998
Resolved
Prior to departue, provide for review servicing certificates for the 2 liferafts that were used during the drill.
Condition: Unknown
Due 6 September 1998
Resolved 9 October 1998
Fire Fighting
Issued 14 August 1997
Resolved
REMOVE LITTER/STRECHER AND WEIGHT SCALE FROM A DECK FORWARD STAIRWAY @ PORT_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997
Resolved
PROVIDE CLASS SURVEY REPORT TO COAST GUARD ATTESTING TO FIRE SMOKE DETECTORS IN ZONE 12 BEING OPERATIONAL/REPAIRED.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Engineering
Issued 23 May 1997
Resolved
PROVIDE CLASS STATEMENT REGARDING STARBOARD TACHOMETER, VERIFY PILOT HOUSE CONTROL (PITCH/SPEED) AND ENGINE ROOM MATCH WITHIN ACCEPTABLE STANDARDS.
Condition: Unknown
Due 23 May 1997
Resolved 28 May 1997
Fire Fighting
Issued 15 August 1996
Resolved
Repair structural integrity of all draft stops. A few of them were checkedand found not in compliance with regulations.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Electrical
Issued 15 August 1996
Resolved
Provide proper floor mats for emergency generators.
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Electrical
Issued 15 August 1996
Resolved
Replace the following emergency lights: 1) Pool Deck, STB side Aft_x001C_ 2) Stairway Forward of SFD 71 3) Officer's Stairway to Bridge deck 4)Sun Deck, Port Side.
Condition: Unknown
Due 15 August 1996
Resolved 16 September 1996
Lifesaving
Issued 15 August 1996
Resolved
Provide proper fireman's gauntlets (gloves) for firefighting suits.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Documentation
Issued 15 August 1996
Resolved
Current training manual is being reviewed and updated. Manual needs to be available for crews review as soon as updates are completed.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Fire Fighting
Issued 15 August 1996
Resolved
Provide a x-conn and a non return valve from fire main to sprinkle system in accordance with regulation 59 (c) Solas 60.
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Lifesaving
Issued 15 August 1996
Resolved
Repair boarding rails on aft, port side, liferaft launching davit. Rail was sealed when painted.
Condition: Unknown
Due 15 November 1996
Resolved 21 August 1996
Electrical
Issued 15 August 1996
Resolved
Repair hydrolic oil leak on Emergency generator starter
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Lifesaving
Issued 15 August 1996
Resolved
Provide/install cleats for liferaft lines as recommended by the manufacture(step #7 of launching instructions).
Condition: Unknown
Due 15 August 1996
Resolved 16 September 1996
Construction/Loadline
Issued 15 August 1996
Resolved
Loadline markings needs to be repainted in contrasting colors.
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Documentation
Issued 15 August 1996
Resolved
Provide criterion number for the ship
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Electrical
Issued 15 August 1996
Resolved
Provide emergency fuel shut off for emergency generator.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Fire Fighting
Issued 15 August 1996
Resolved
Remove all laundry from sprinklers pipes to 18"
Condition: Unknown
Due 15 August 1996
Resolved 21 August 1996
Electrical
Issued 15 August 1996
Resolved
Repair electrical outlets in casino. Provide electrical cover for those missing it.
Condition: Unknown
Due 15 August 1996
Resolved 16 September 1996
Fire Fighting
Issued 15 August 1996
Resolved
replace sprinkles heads that have been painted over or burned (by way of testing alarm). Those are: 1) Port side Passenger embarkation 2) Main Deck aft Embarkation port 3) Main deck aft embark stbd 4) Crew gangway
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Fire Fighting
Issued 15 August 1996
Resolved
Repair or adjust Sliding Fire Door L5 and SFD 45
Condition: Unknown
Due 15 August 1996
Resolved 21 August 1996
Fire Fighting
Issued 15 August 1996
Resolved
Prove proper operation of aft emergency fire pump.
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Fire Fighting
Issued 15 August 1996
Resolved
Ensure all self contained breathing apparatus bottles are interchangeable
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Lifesaving
Issued 15 August 1996
Resolved
Repair and replace emergency exit interior door stb side inside the sunset lounge.
Condition: Unknown
Due 15 November 1996
Resolved 21 August 1996
Engineering
Issued 15 August 1996
Resolved
Repack the shaft for bilge and ballast pump main space.
Condition: Unknown
Due 15 November 1996
Resolved 16 September 1996
Documentation
Issued 15 August 1996
Resolved
REVISE FIRE CONTROL PLAN TO INCLUDE MOVEMENT OF DEEP FAT FRYERS AND THE NEWLY INSTALLED FIREMAIN CROSS-CONNECTION TO THE SPRINKLER MAIN.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Lifesaving
Issued 7 September 1995
Resolved
REPAIR AND CALIBRATE THE STEERING COMPASS FOR THE #8 LIFEBOAT. COMPASS WASFOUND TO HAVE LOST ALL DAMPENING FLUID.
Condition: Unknown
Due 12 September 1995
Resolved 14 September 1995
Documentation
Issued 25 August 1995
Resolved
HAVE KAMEWA TECHNICIAN RIDE VESSEL AND PROVIDE REPORT. IF TECHNICIAN IS NOT AVAILABLE, VESSEL SHALL NOT DEPART.
Condition: Unknown
Due 25 August 1995
Resolved 1 September 1995
Construction/Loadline
Issued 25 August 1995
Resolved
PROVIDE DIVERS, FIRST LIGHT ON 26AUG95, TO EXAMINE HULL AND PROPELLAR ASSEMBLY FOR LEAKS.
Condition: Unknown
Due 26 August 1995
Resolved 1 September 1995
Fire Fighting
Issued 6 December 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP TO SATISFACTION OFCLASS SOCIETY SURVEYOR NLT 16 DEC 1994. FAX STATEMENT FROM CLASS TO [name withheld].
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Electrical
Issued 6 September 1994
Resolved
PROVIDE COVERS FOR BARE FLUORESCENT BULBS IN MULTIPLE AREAS THROUGHOUT MACHINERY SPACES AND CAR DECK.
Condition: Unknown
Due 6 September 1994
Resolved 6 September 1994
Documentation
Issued 6 September 1994
Resolved
NEW LOADLINE AND PSSC TO BE REISSUED BY CLASS.
Condition: Unknown
Due 13 September 1994
Resolved 18 September 1994
Documentation
Issued 14 September 1993
Resolved
A violation of 46 CFR 42.13-40(a) in that the loadline was not plainly visible due to marine growth. Vessel subject to regulations as per 46 CFR 2.01-13(b).
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Documentation
Issued 14 September 1993
Resolved
All officers on board are to hold valid Bahamian licenses/certificates unless exempted by the Bahamian government._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Documentation
Issued 14 September 1993
Resolved
Paint the vessel's assigned load line in a contrasting color to the hull.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Engineering
Issued 15 June 1993
Resolved
VESSEL TO REPAIR/MITIGATE OIL LEAK FROM THE STARBOARD STREN TUBE GLAND. OIL LEAKS INTO WATER WHEN SHAFT IS TURNING CAUSING A SLIGHT OIL SHEEN.
Condition: Unknown
Due 15 June 1993
Resolved 15 June 1993
Fire Fighting
Issued 15 June 1993
Resolved
TWELVE SMOKE DETECTORS MISSING IN SECTIONS OF CREW AREAS. VESSEL TO COMMENCE TWENTY FOUR HOUR FIRE PATROL THROUGHOUT VESSEL. COMPLETION OF ROUND TO BE LOGGED. FLAG ADMINISTRATION TO PROVIDE EVIDENCE OF SATISFACTORY REPAIRS PRIOR TO THE LIFTING OF THE FIRE PATROLS.
Condition: Unknown
Due 15 June 1993
Resolved 15 June 1993
Lifesaving
Issued 16 March 1993
Resolved
RENEW REFLECTIVE TAPE ON ALL STBD LIFEBOATS (#s 1,3,5,&7). OLD TAPE HAS BEEN PAINTED OVER W/INTERNATIONAL ORANGE PAINT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Construction/Loadline
Issued 16 March 1993
Resolved
PROVIDE CLASS APPROVAL ON REPAIRS TO HULL IN STEERING SPACES & OTHER AREAS.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993
Resolved
PROPERLY WIRE NEW AIR COMPRESSOR & LAUNDRY WASHERS IN CAR DECK, STARBOARD_x001C_ SIDE AFT.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993
Resolved
PROVIDE EXPLOSION PROOF LIGHT IN BOS'N STORES, PORTSIDE FORWARD.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Construction/Loadline
Issued 16 March 1993
Resolved
CLEAN OIL FROM BILGES IN SHAFT ALLEY AREAS.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993
Resolved
RENEW ELECTRICAL WIRING AND REPLACE LIGHT COVER FOR LIGHT IN CREW SPACE PASSAGEWAY PORTSIDE AFT, NEAR SFDS 46.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Engineering
Issued 2 January 1993
Resolved
Failure of blade-to-hub seal on vessel's controllable pitch propeller resulted in discharge of oil while underway on the high seas. Discharge observed outside of U. S. Exclusive Economic Zone. Discharge meets criteria for exemption under 33 C.F.R. 151.11(a)(2).
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Unknown
Issued 2 January 1993
Resolved
Vessel discharged oil due to damage to ship's equipment. Report required by 33 C.F.R. 151.15(e)(2)(ii) was not made to COTP Miami. No record of report to any other flag state. No evidence discharge occurred in U. S. waters or in waters under U. S. jurisdiction.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Documentation
Issued 23 April 1992
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992