MAURY USCG vessel records
← All vessels

CP-21

Built
1986
Last inspected
16 July 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 16 July 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 37 calendar years (1990–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

356884
Flag
UNITED STATES
Tonnage
402 - Regulatory (Subpart C or D), Gross Ton 402 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-356884
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

CAPT. TUFFY Towing Vessel · MISLE 209962 · 5 August 1999 · activity 46363

Inspection history · 150

16 July 2026 Vessel Attendance · Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8439914
21 April 2026 MTSA Verification · Re-Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8352621
20 January 2026 Re-Inspection · MTSA/ISPS Verification · Vessel Attendance
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8295683
4 September 2025 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8227010
24 July 2025 Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8193708
16 May 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8137417
10 April 2025 Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8109546
16 January 2025 Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8064559
25 September 2024 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8009157
23 July 2024 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7965198
30 April 2024 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7904021
29 January 2024 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7857439
2 October 2023 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7801649
22 August 2023 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7774418
14 April 2023 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7668705
17 January 2023 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7623247
4 October 2022 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7567065
6 July 2022 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7498612
5 April 2022 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7425060
6 January 2022 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7376138
1 October 2021 COI Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7324814
13 July 2021 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7255411
13 April 2021 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7174112
5 January 2021 Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7119930
5 October 2020 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7069892
14 May 2020 MTSA Verification · Internal Structural Exam · Re-Inspection · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6953350
27 March 2020 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6932460
6 January 2020 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6883596
7 October 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6824645
9 July 2019 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6743721
15 April 2019 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6665238
10 January 2019 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6608634
2 October 2018 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6549343
2 July 2018 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6467327
11 January 2018 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6338431
3 October 2017 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6279502
6 July 2017 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6201247
6 April 2017 Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6201178
5 January 2017 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6066471
5 October 2016 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6015644
7 July 2016 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5933040
11 April 2016 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5853576
11 January 2016 In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5795475
28 August 2015 Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5732397
18 August 2015 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5219062
16 April 2015 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5104396
14 January 2015 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5100962
8 October 2014 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5001239
16 July 2014 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4924284
17 April 2014 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4875086
15 January 2014 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4783614
8 October 2013 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4730644
11 July 2013 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4652656
11 October 2012 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4461433
18 July 2012 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4383712
11 April 2012 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4284680
18 January 2012 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4227474
18 October 2011 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4170051
17 August 2011 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4128824
2 November 2010 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3882347
27 August 2010 Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3845378
12 May 2010 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3736798
11 February 2010 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3678495
19 August 2009 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3570834
14 May 2009 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3499469
11 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3418075
14 November 2008 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3362843
29 August 2008 Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3321144
20 May 2008 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3293366
13 February 2008 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3188102
13 November 2007 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3126592
15 August 2007 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3037957
15 May 2007 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2931281
15 February 2007 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2903487
15 November 2006 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2820569
20 June 2006 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2690638
22 March 2006 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2607745
14 December 2005 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2583752
5 October 2005 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2508140
14 September 2005 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2491427
4 May 2005 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2348583
25 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2342572
10 February 2005 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2302947
10 November 2004 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2245255
11 August 2004 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2163367
11 May 2004 COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2064550
24 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2012369
19 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2008991
12 February 2004 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2015943
20 November 2003 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1951675
14 August 2003 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1876168
14 May 2003 COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1796909
12 February 2003 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1743706
15 November 2002 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1706881
15 August 2002 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1662588
15 May 2002 COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1616822
13 February 2002 Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1492074
5 November 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1075731
17 August 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1069196
16 May 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463674
16 February 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384678
15 November 2000 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469012
31 August 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823518
1 June 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451559
9 March 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 817965
19 January 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1045877
7 December 1999 Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438950
6 October 1999 Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401084
5 August 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 46363
18 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1085325
9 June 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464188
20 April 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1123881
18 March 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456672
17 December 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397043
17 September 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444052
9 July 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1128483
17 June 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472518
20 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457547
19 December 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433288
19 September 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1437295
20 June 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404401
18 March 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374901
17 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396629
4 October 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442465
28 June 1996 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380585
13 April 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 666377
11 April 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 666376
9 April 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360455
13 February 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407611
9 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442312
7 July 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392258
4 April 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466931
18 January 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 864861
11 January 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471482
11 October 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464545
10 August 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354870
12 April 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428325
31 January 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446058
23 November 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467849
12 August 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382620
14 April 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431210
19 January 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382516
14 October 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254267
16 July 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956070
17 April 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943676
28 August 1991 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249518
26 April 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306383
25 January 1991 Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927134
15 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921771
23 October 1990 Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920341

Deficiency record · 71

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2026 Resolved
Each section of firehose must be a lined commercial firehose that conforms to UL 19. MI observed the firehoses fitted throughout the barge weren't UL 19 rated. Vessel shall properly outfit vessel within 14 days to the satisfaction of the MI.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 27 July 2026
Resolution: Installed the new hoses and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2026 Resolved
Each fire hydrant must have at least one length of firehose, a spanner wrench, and a hose rack or other device for stowing the hose. MI observed that the barge was missing spanner wrenches in the hose racks. Vessel shall properly outfit vessel to the satisfaction of the MI.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 27 July 2026
Resolution: Spanner wrenches were installed sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 July 2026 Resolved
Every crewmember must participate in at least one abandon-ship drill and one fire drill every month...The vessel shall ensure that drills performed by the crew of the support tow vessel incorporate the ferry carrying passengers, in accordance with regulatory timelines. Provide evidence of drill completion to the MI within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 27 July 2026
Resolution: Drills are now seperated and completed on the barge.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 January 2024 Resolved
Vessels must carry survival craft to accommodate 67% of persons onboard, in accordance with 46 CFR 199.630 (a) and (g). Only one serviceable IBA with proper float-free arrangements was onboard and its capacity was 25 persons. Passenger count reduced to 34 (accommodates 34 passengers and 3 crew at the allowable level of 67% of total persons). Install proper required amount of survival craft (with float-free attachment) to regain allowable passenger count noted on COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2024
Resolution: IBAs for 80 persons back onboard and properly serviced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2024 Resolved
Vessel operated with passengers prior to Code 60 deficiency being cleared by USCG inspectors, as directed by the CG835V issued 05 OCT 2023.
Action required: 10 - Deficiency Rectified
Resolved 29 January 2024
Resolution: Voids emptied. CG Inspectors only learned of voids being emptied 5 days after vessel began operating with passengers.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 October 2023 Resolved
The vessel's Coast Guard-issued stability letter states that the vessel's bilges and voids shall be kept pumped to minimum content at all times consistent with pollution prevention requirements. The port center void has been filled with water to lower vessel freeboard as vessel is temporarily being used as a platform for accessing a T-boat due to low-water conditions. Remove water and make ready for inspection prior to operating vessel when returning to normal vessel operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 January 2024
Resolution: Water removed from voids.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 October 2023 Resolved
Each opening in an exposed weather deck must be weathertight (capable of preventing penetration of water into the vessel in any sea condition). Manhole covers and gaskets for several voids on the starboard-barge side of the vessel are leaking, allowing excessive water intrusion. Repair covers and gaskets to prevent water ingress into voids and remove excess water from voids prior to operating vessel to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 January 2024
Resolution: Hatch covers repaired
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 22 August 2023 Resolved
The vessel's Coast Guard-issued stability letter states that the vessel's bilges and voids shall be kept pumped to minimum content at all times consistent with pollution prevention requirements. The port center void contains 8 inches of water throughout the bilge, as well as grit matter. Remove all water and grit from void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 22 September 2023
Resolution: Water and grit removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 August 2023 Resolved
Each opening in an exposed weather deck must be weathertight (capable of preventing penetration of water into the vessel in any sea condition). Manhole cover and gasket for port center void are leaking, allowing excessive water intrusion. Repair cover and gasket to prevent water ingress into void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 6 September 2023
Resolution: Gasket renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2023 Resolved
At least two life buoys with a self-igniting light attached to the life buoy must be carried. One self-igniting light was not working. Repair light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 6 September 2023
Resolution: New lights installed on life buoys.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 October 2022 Resolved
Clear instructions must be provided on the vessel that detail the actions each person on board should follow in the event of an emergency. Copies of the muster list must be posted in conspicuous places and should specify emergency signals, duties assigned to the different members of the crew in relation to passengers in case of emergency, as detailed in 46 CFR 199.80. Emergency instructions were missing elements as pertains to mustering passengers and launching life saving equipment. Make necessary corrections to instructions and muster list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 2 November 2022
Resolution: Assignment of duties updated to include duties of crew regarding passengers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2022 Resolved
Uncovered barges shall carry at least two fire axes. One of the axes was broken. Repair or replace axe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 28 October 2022
Resolution: Fire axes replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2022 Resolved
Each life jacket aboard vessel must be approved under approval series 160.155, 160.176, or 160.177. Additionally, each life jacket container must be marked with the proper quantity of life jackets within. 1 adult size life jacket were found unserviceable. Unserviceable life jackets were in excess of required carriage amount. Replace unserviceable life jackets or change label on container to match actual number within (if unserviceable life jackets will not be replaced).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 28 October 2022
Resolution: Life jacket replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2022 Resolved
Each life jacket aboard vessel must be approved under approval series 160.155, 160.176, or 160.177. Additionally, each life jacket container must be marked with the proper quantity of life jackets within. 2 child size life jackets and 1 adult size life jacket were found unserviceable. Unserviceable life jackets were in excess of required carriage amount. Replace unserviceable life jackets or change label on container to match actual number within (if unserviceable life jackets will not be replaced).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2022
Resolved 13 July 2022
Resolution: Life jackets replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 October 2021 Resolved
A vessel being pushed ahead that is not part of a composite unit shall exhibit at the forward end: sidelights and a special flashing light. Port sidelight was inoperable, with a temporary sidelight installed until replacement parts arrive. Repair port sidelight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2021
Resolved 15 October 2021
Resolution: Port sidelight repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2021 Resolved
Electrical installations on vessels must ensure protection of passengers, crew, and other persons, and the vessel, from electrical hazards. Repair damaged electrical outlet near port bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 15 October 2021
Resolution: Outlet repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2021 Resolved
Where extinguishing equipment are not required, but are installed, the equipment must meet the requirements of 46 CFR. Replace failed supply hose connecting the firemain of the towing vessel and CP-21's fire hose reel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 15 October 2021
Resolution: Hose renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2021 Resolved
Each life jacket container must be marked with the quantity of life jackets stowed inside. 02 excess life jackets were found to be unserviceable and were removed. Re-mark container with appropriate number of life jackets or replace life jackets to ensure stowage number corresponds with equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 15 October 2021
Resolution: Life jackets replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 13 July 2021 Resolved
Tests and inspections shall be carried out during each inspection to demonstrate the proper condition and operation of rescue boats. Fast rescue boat was only able to propel on outboard engine for approximately 2 minutes before engine failed. Company provided a new engine and submitted evidence of proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 July 2021
Resolved 13 July 2021
Resolution: Vessel operator swapped out outboard engine and proved proper operation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 June 2020 Resolved
If, during an internal structural examination, damage to the structural members is discovered, the OCMI may require the vessel to affect permanent repairs. Three cracked welds were discovered in the port-forward-centerline void. Cracked welds were along one of the the top transverse structural members under the vehicle deck. Affect permanent repairs to cracked welds. Repairs must be made to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 29 July 2020
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2013 Resolved
Repaint matte surfaces for the P/S running lights aboard subj barge.
Action required: 705 - Other - as specified
Resolved 20 August 2013
Lifesaving › Lifebuoys › Serviceable
Issued 11 July 2013 Resolved
Renew SOLAS tape on life rings.
Action required: 705 - Other - as specified
Resolved 20 August 2013
Electrical › Electrical Distribution System (service) › Cable
Issued 11 July 2013 Resolved
Repair electric cabling from [name withheld] (UTV) to subj barge.
Action required: 705 - Other - as specified
Resolved 20 August 2013
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 11 April 2012 Resolved
Renew hydrostatic release on both IBA's.
Action required: 705 - Other - as specified
Resolved 13 April 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2012 Resolved
Remove dead end cable in galley cupboard aboard the [name withheld].
Action required: 705 - Other - as specified
Resolved 13 April 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2012 Resolved
Repair emergency light on the lower level of the engine room, forward bulkhead aboard the [name withheld].
Action required: 705 - Other - as specified
Resolved 13 April 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 April 2012 Resolved
Replace mounting screws for front cover of the electrical panel on the forward bulkhead of the engine room aboard [name withheld].
Action required: 705 - Other - as specified
Resolved 13 April 2012
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 April 2012 Resolved
Provide copy of NAV Rules.
Action required: 705 - Other - as specified
Resolved 13 April 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 August 2011 Resolved
Repair life ring light. Low intensity.
Action required: 705 - Other - as specified
Resolved 24 August 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 17 August 2011 Resolved
Replace faded operating instructions on marked portable fire extinguishers.
Action required: 705 - Other - as specified
Resolved 24 August 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 November 2008 Resolved
provide proper brackets
Due 14 December 2008
Resolved 21 November 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 November 2008 Resolved
service ext at stbd bow
Due 14 December 2008
Resolved 21 November 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 November 2008 Resolved
replace life ring light on stbd side.
Due 14 December 2008
Resolved 21 November 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 May 2007 Resolved
Provide proper brackets for all portable fire extinguishers.
Action required: 705 - Other - as specified
Resolved 4 June 2007
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2005 Resolved
Effect permanent repairs to the head log area prior to carriage of passengers and/or vehicles
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Resolution: Repair involved gauging and welding a fracture of approximately 6 inches to a final length of 10 inches. Visual inspection reveled no deficiencies. GS
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 August 2003 Resolved
Provide additional BI extinguisher for rescue boat and service BI extinguisher on port side of deck house.
Due 15 September 2003
Resolved 18 August 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 November 2002 Resolved
Replace expired items in all first aid kits.
Due 15 December 2002
Resolved 22 November 2002
Resolution: Corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 November 2002 Resolved
Replace line for ring buoy float light.
Due 15 December 2002
Resolved 22 November 2002
Resolution: Corrected.
Stability › Watertight Integrity
Issued 15 August 2002 Resolved
Replace gaskets on void access covers. LEGACY COMPONENT DESC: Void Access Covers
Due 29 August 2002
Resolved 19 August 2002
Resolution: Corrected.
Fire Fighting › Nozzles › Condition
Issued 15 August 2002 Resolved
Replace spud chain on fire hose nozzle.
Due 29 August 2002
Resolved 19 August 2002
Resolution: Corrected.
Lifesaving › Buoyant Apparatus
Issued 13 February 2002 Resolved
Replace weak link on both Life Float assemblies. LEGACY COMPONENT DESC: Weak Link
Due 20 February 2002
Resolved 15 February 2002
Resolution: Received copy of purchase order and captains statement of replacement.
Lifesaving
Issued 5 November 2001 Resolved
PROVIDE A GENERAL ALARM SYSTEM ABOARD THE TOWING VESSEL THAT MEETS THE REQUIREMENTS OF 46CFR27.205 AND THAT IS SEPERATE FROM THE SHIPS WHISTLE.
Condition: Unknown
Due 5 December 2001
Resolved 13 February 2002
Resolution: Received verbal indication from CAPT that requirement was satisfied and pends witness by this office. 13FEB02- witnessed SAT test of general alarm system.
Fire Fighting
Issued 5 November 2001 Resolved
PROVIDE AND CONDUCT AN OPERATIONAL TEST OF THE TOWING VESSEL'S FIRE DETECTION SYSTEM IAW MANUFACTURERS INSTRUCTIONS.
Condition: Unknown
Due 5 December 2001
Resolved 13 February 2002
Resolution: Received verbal indication from CAPT that the requirement was satisfied and pends witness by this office. 13FEB02- Witnessed SAT test of fire detection system.
Fire Fighting
Issued 7 December 1999 Resolved
REPLACE/RECHARGE PORTABLE FIRE EXTINGUISHER ON THE STBD SIDE OF THE DECK HOUSE.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Construction/Loadline
Issued 7 December 1999 Resolved
CROP AND RENEW STARBOARD CENTER VOID HATCH.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Construction/Loadline
Issued 7 December 1999 Resolved
OPEN FOR INSPECTION ALL HATCHES ON STARBOARD BARGE.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Electrical
Issued 7 December 1999 Resolved
PERMANENTLY MOUNT AND PERMANENTLY WIRE TIMER IN PASSENGER WAITING AREA.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Construction/Loadline
Issued 7 December 1999 Resolved
CROP AND RENEW STBD STERN GATE POST SUPPORT.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Construction/Loadline
Issued 7 December 1999 Resolved
REPAINT DRAFT MARKS WITH A CONTRASTING COLOR.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Electrical
Issued 6 October 1999 Resolved
RE-LABEL BREAKERS AND REPLACE MISSING KNOB ON HEATER IN DECK HOUSE.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 6 October 1999 Resolved
DEWATER, AS NECESSARY, AND MAKE OTHER VOID SPACES AVAILABLE FOR INSPECTION AT NEXT QUARTERLY INSPECTION.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Construction/Loadline
Issued 6 October 1999 Resolved
REPAINT DRFAT MARKS AND DETERMINE MAXIMUM LOAD DRAFT READING AND PLACE COPYOF STABILITY LETTER ON BARGE.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Lifesaving
Issued 6 October 1999 Resolved
RESTENCIL LIFE RINGS AND LIFE SAVING GEAR WITH VESSEL NAME AND REWORK LIFE RING THROWING LINES FOR EASY DEPLOYMENT.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Electrical
Issued 6 October 1999 Resolved
MAKE ALL PERMANENT PLUG IN APPLIANCES PERMANENTLY WIRED IN AND RELOCATE ANDPERMANENTLY WIRE OUTBOARD WHITE LOAD TO OUTSIDE RAIL WHERE IT CAN BE BEST SEEN.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Fire Fighting
Issued 6 October 1999 Resolved
REPAIR AND DEOMONSTRATE SMOKE ALARM EXTERIOR ALARM BELL AFT OF BARGE DECK HOUSE.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 6 October 1999 Resolved
REPAINT BILGE SUCTION LOCATIONS ON DECK WITH CONTRASTING COLOR.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Fire Fighting
Issued 6 October 1999 Resolved
REPAIR / REPLACE FIREHOSE WHERE LEAKING AND RE-BAND AS ORIGINAL.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Lifesaving
Issued 9 June 1999 Resolved
REPAIR TO MANUFACTURERS SPECIFICATIONS, OR REPLACE, THE 12 MAN BUOYANT APPARATUS ON PORT SIDE OF DECKHOUSE.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Fire Fighting
Issued 18 March 1999 Resolved
RESTENCIL FIRE AXES.
Condition: Unknown
Due 18 April 1999
Resolved 18 March 1999
Fire Fighting
Issued 18 March 1999 Resolved
REPLACE/RESTENCIL FIRE HOSE STORAGE BOX ON STBD SIDE AFT.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Fire Fighting
Issued 18 March 1999 Resolved
INSTALL REMOTE START/STOP SWITCH IN PILOT HOUSE FOR FIRE PUMP.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 18 March 1999 Resolved
REPAIR, USING APPROVED MANUFACTURER SPECIFICATION GUIDELINES, THE STBD 12 MAN BOUYANT APPARATUS.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 18 March 1999 Resolved
INSTALL PFD DONNING INSTRUCTIONS ON PFD CONTAINERS MISSING SAME. (2EA)
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Unknown
Issued 17 June 1998 Resolved
INITIATE A SYSTEM OF REGUARLY SCHEDULED TRAINING FOR RESCUE OPERATION,_x001C_ FIRE FIGHTING, AND ABANDON SHIP DRILLS. DOCUMENTATION OF DRILLS TO BE KEPTAVAILABLE FOR INSPECTION BY A USCG INSPECTOR.
Condition: Unknown
Due 17 June 1998
Resolved 17 June 1998
Lifesaving
Issued 17 June 1998 Resolved
PROVIDE A SYSTEM THAT WILL RAPIDLY LAUNCH RESCUE BOAT. THE EXISTING SYSTEMWILL NOT ALL FOR ADEQUATE RESPONSE.
Condition: Unknown
Due 17 June 1998
Resolved 25 June 1998
Lifesaving
Issued 20 June 1997 Resolved
PERFORM A RESCUE BOAT PERFORMANCE TEST USING THREE PEOPLE AND AN OUTBOARD MOTOR AND FUEL TANK.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Documentation
Issued 9 April 1996 Resolved
Vessel owner/operator failed to renew the vessels certificate of inspectionbefore it expired and operated the vessel after the expiration date.
Condition: Unknown
Due 9 April 1996
Resolved 10 April 1996
Documentation
Issued 9 November 1995 Resolved
Provide a Chemical Testing Program to the US Coast Guard by submitting the proper forms.
Condition: Unknown
Due 9 November 1995
Resolved 9 November 1995
Electrical
Issued 11 January 1995 Resolved
Repair or replace with a marine type grade electrical extension cord, whichis used to operate the vessel's night mooring lights from the towboat to the barge.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Accommodation/Occupational Safety
Issued 23 October 1990 Resolved
RENEW ELECTRIC HEATER WITH ONE THAT IS UL APPROVED FOR MARINE USE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Documentation
Issued 23 October 1990 Resolved
PROVIDE DOCUMENTATION VERIFING THAT INTACT STABILITY AND DAMAGE STABILITY IS ADEQUATE FOR THE VESSEL'S INTENDED ROUTE AND SERVICE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.