EMERALD SEE

Built
1990
Last inspected
20 January 2026
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBC7310
357058
Flag
UNITED STATES
Maury page id
psix-357058

Documentation record

Registered dimensions (L × B × D)40.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS · TARPON SPRINGS FL · built 1990
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portBIG PINE KEY, FL
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 61 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA EAGLE Passenger (Inspected) · MISLE 1257440 · 2 March 2021 · activity 7149107

Inspection history · 17

20 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8298451
15 January 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8296149
7 January 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8060870
18 January 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7851571
9 January 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7863240
12 December 2022 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7601952
11 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7575592
3 February 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7389437
11 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7146018
2 March 2021 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7149107
30 October 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7070139
10 March 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6920698
29 October 2018 Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection · Examination of Repairs · Construction Oversight · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570894
11 December 2017 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6322077
12 October 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6286453
26 May 2017 Deficiency Check · Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6181711
1 April 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5839750

Deficiency record · 61

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 January 2026 Resolved
Port aft electronic submersible bilge pump only works in manual mode. Mark pump switch at operating station as manual only or repair automatic mode.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2026
Resolved 4 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2026 Resolved
Apply new Type II retroreflective material to the ring life buoy and life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2026
Resolved 4 February 2026
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 January 2025 Resolved
The hydrostatic release for the Cat 1 EPIRB is expired. Provide a new hydrostatic release and mark to expire two years after install. Vessel restricted to operating within three miles from shore.
Action required: 705 - Other - as specified
Resolved 7 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024 Resolved
Both port and starboard fuel supply line shutoff valves located at the tank connection are corroded and unable to fully close. Replace the port and starboard tank connection fuel shutoff valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2024
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 January 2024 Resolved
Mark the vessel's name and hailing port in four inch minimum letters on the stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 December 2022 Resolved
Provide a valid FCC Safety Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2022 Resolved
Attach the floating waterlight to the ring life buoy with a lanyard (3' - 6') and corrosion resistant clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2022 Resolved
Clearly mark the vessel's name on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2022 Resolved
Make stern light operational prior to operating at night or during periods of reduced visibility.
Action required: 705 - Other - as specified
Resolved 9 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 February 2022 Resolved
Permanently mount the aft submersible bilge pump float switch in the starboard hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2021 Resolved
The battery for the Emergency Position Indicating Radiobeacon was expired. Vessel restricted to operating within 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 11 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 March 2021 Resolved
Vessel did not have an appropriate sounding producing device for its length.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 30 October 2020 Resolved
Identified cracking (approx. 6”) in the gelcoat/FRP on the transom at the port and starboard tunnel corners. Grind back to good FRP and renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 October 2020 Resolved
Holes were drilled in the head floor/wall to pass bilge hoses and electric cables through. Plug holes to prevent deck water from entering the port hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2020 Resolved
Provide 3 fire buckets with lanyards and label “Fire Bucket”, each bucket shall be 2 1/2 gallons.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2020
Resolution: 3 Buckets supplied
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 March 2020 Resolved
Provide deck course rails at intervals no less than 12” at embarkation locations. 3 of the 4 locations were missing rail courses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2020
Resolution: courses installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 March 2020 Resolved
Replace weak link that is properly sized for installed life float (15 pax), weak link does not have indication tag.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2020
Resolution: link installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 March 2019 Resolved
Life Floats must be linked together with line around body of float when using a single painter line. Line shall be the same size and type as painter line and be long enough so that each Life Float can be deployed at a time.
Action required: 705 - Other - as specified
Due 13 March 2019
Resolved 13 March 2019
Resolution: Life Floats properly linked together.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 March 2019 Resolved
Weak link on painter line for life floats shall be connected to the vessel. Weak link is currently connected to the Life Float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: Weak link reconfigured and installed properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 March 2019 Resolved
Provide access for crew member to be able to secure port-side positive shutoff valve for submersible bilge pump. Currently unable to access the area behind head.
Action required: 705 - Other - as specified
Resolved 13 March 2019
Resolution: Access panel added.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 March 2019 Resolved
Provide 02 additional red hand-held flares.
Action required: 705 - Other - as specified
Resolved 13 March 2019
Resolution: All required flares provided onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2019 Resolved
Provide a corrosion resistant clip for water-light lanyard for ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: Clip provided.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 March 2019 Resolved
Demonstrate operation of magnetic compass light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2019
Resolution: Compass light operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 March 2019 Resolved
Demonstrate operation of anchor light (all around white). Vessel is restricted to daylight operations.
Action required: 705 - Other - as specified
Due 13 March 2019
Resolved 16 March 2019
Resolution: Light operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 March 2019 Resolved
Demonstrate operation of forward bilge pump and automatic indicator light. Unable to operate pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: Pump operational.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 March 2019 Resolved
Post all pages of COI and Stability Letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: COI and Stability Letter posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 March 2019 Resolved
Provide currently publications for area of operation (light list, Coast Pilot, Tide tables, and currents).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: All publications on board and up to date.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 March 2019 Resolved
Update Emergency Procedures to reflect vessel arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: Emergency procedures updated.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 March 2019 Resolved
Supply VHF radio with a GPS input.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 April 2019
Resolution: GPS operational on VHF.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2019 Resolved
Provide ammonia inhalants (10) for first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2019
Resolution: Ammonia inhalants supplied and stored in First Aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2019 Resolved
Ground fuel tanks to a common ground, wire shall be 14AWG and green.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2019
Resolution: Both tanks grounded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2019 Resolved
Provide deck courses for each embarkation/debarkation area at intervals not greater than 12 inches.
Action required: 705 - Other - as specified
Due 13 March 2019
Resolved 16 March 2019
Resolution: All deck courses installed at embarkation stations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 March 2019 Resolved
Seal all areas on the weather deck to prevent water ingress into the hull (Trunks and Head).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2019
Resolution: Trunks sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2019 Resolved
Wire connects on battery terminals shall be installed with the largest gauge wire on the bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2019
Resolution: Terminals connected properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 March 2019 Resolved
Submersible bilge pump discharge line must have a positive shutoff valve installed at the hull penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 March 2019
Resolution: Positive shutoff valve installed at the hull penetration.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 October 2018 Resolved
Repair/replace Port and STBD stringers in forward compartments, FRP is delaminated and wood is rotted. Prior to credit dryddock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: All stringers have been replaced with treated wood and covered with FRP.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 October 2018 Resolved
Repair/replace deck beams and shelf's on outboard hull, wood is rotted. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: All deck beams and shelf's were replaced with treated wood and covered/coated with FRP.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 October 2018 Resolved
Repair/replace hull frames on both Port and STBD sides, plywood is rotted. Prior to credit dryddock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: All hull frames in both Port and STBD hulls were replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 October 2018 Resolved
Grind out to good glass on identifies areas on external hull, blistering located on STBD hull. **Prior to credit dryddock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: All areas on hull have been properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 October 2018 Resolved
Grind out to good glass on internal STBD hull just forward of glass bottom, FRP is delaminated. **Prior to credit dryddock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: Area was repaired after the viewing hull glass was removed and glassed over with FRP and utilized a balsa core.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 October 2018 Resolved
Repair Port transom triangle stringer, delaminated area identified. **Prior to credit dryddock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: Both transoms were removed and replaced with same layup schedule, balsa core was replaced with 2 3/4in sheets of treated plywood.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 October 2018 Resolved
Repair/replace STBD transom, core is rotted due to ingress if water. Prior to credit dryddock.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: Both transoms were removed and replaced with same layup schedule, balsa core was replaced with 2 3/4in sheets of treated plywood.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2018 Resolved
Install fuel tanks built to 46CFR182.440 standards and fill to 95% capacity to demonstrate leak free installation. **Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 6 March 2019
Resolution: New tanks from Corinthian Catamarans and pressed with 95% fuel with no observed leaks.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 December 2017 Resolved
Provide visual indicators at operating station to indicate automatic bilge pump operation.
Action required: 705 - Other - as specified
Due 15 January 2018
Resolved 11 January 2018
Resolution: Float switches removed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 December 2017 Resolved
Deck rail courses at embarcation stations must be installed at no more than 12 inch intervals.
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 11 January 2018
Resolution: Additional rail courses added.
Engineering › Bilge Water Management System › Pump
Issued 12 December 2017 Resolved
Demonstrate operation of aft starboard bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: Pump re wired, operational.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 December 2017 Resolved
Install fire extinguishers in approved carrier or to satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 15 December 2017
Resolution: Adequate carriers installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 December 2017 Resolved
Install floating water light in approved/manufacture recommended stowage arrangement.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 15 December 2017
Resolution: Manufacture devices used.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 December 2017 Resolved
Remove securing devices for PFD stowage locations. Must not be capable of being locked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: Locking devices were modified.
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 December 2017 Resolved
Label fuel shutoffs for port/STBD tanks.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 15 December 2017
Resolution: Fuel shutoffs labeled.
Documentation › Certificates/Documents › FCC SSL
Issued 12 December 2017 Resolved
Provide FCC marine radio operator permit for crew member.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2017
Resolution: Permit obtained by owner.,
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 12 December 2017 Resolved
Provide proff of pre-emplyment testing prior to acting as crew member.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: Proof of testing provided.
Engineering › Gasoline Engine (propulsion) › Ignition Wire (4 cycle)
Issued 12 December 2017 Resolved
Demonstrate proper operation of main propulsion and conduct underway MOB drill to satisfaction of USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: Vessel got underway and completed drills.
Construction/Loadline › Hull › Hull Plating
Issued 12 October 2017 Resolved
Grind out delaminated/damaged glass in identified areas in hull (port and starboard quarters and area forward of port side glass bottom) Submit repair proposal to local OCMI prior to beginning repairs.
Action required: 705 - Other - as specified
Resolved 10 November 2017
Resolution: Conducted repairs to hull and deck.
Lifesaving › Lifefloat › Netting
Issued 26 May 2017 Resolved
Life float is missing the center platform and net. Repair/renew.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 May 2017 Resolved
Grabline is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 May 2017 Resolved
First aid kit is incomplete. provide all contents.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 May 2017 Resolved
FCC safety Radio cert is missing. Provide new cert.
Due 9 June 2017
Resolved 5 June 2017
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 26 May 2017 Resolved
Vessel does not have a waste management plan. Provide/post.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Navigation › Piloting/Steering › Marine Charts
Issued 26 May 2017 Resolved
All vessel charts and navigation publications are expired. Update or renew.
Due 9 June 2017
Resolved 5 June 2017
Lifesaving › Hand Flares › Storage
Issued 26 May 2017 Resolved
Flare storage must be in a brightly colored watertight container that is marked. Provide new container.
Due 9 June 2017
Resolved 5 June 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.