Records from 2010 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 20
24 November 2025
Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8273494
1 July 2025
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8172334
19 December 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8049172
17 October 2024
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8022176
6 December 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7839957
15 September 2023
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7792088
17 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7397527
10 November 2021
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7348798
7 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170213
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108403
6 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6921993
26 February 2020
Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6915849
8 April 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6657860
8 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6449610
21 February 2018
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6358515
21 February 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6360343
18 February 2018
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6358532
7 July 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6201421
6 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5936658
23 February 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5820318
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 November 2021
Resolved
VESSEL MUST BE ATTENDED BY USCG TO WITNESS DRILLS WITH REQUIRED CREW ON COI PRIOR TO DEPARTURE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2023
Resolution: Vessel has undergone drills with crew as required.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 November 2021
Resolved
The Emergency Position Indicating Radio Beacon (ERPIB) was not working and was sent out for repairs or replacement. ERPIRB is require for operating on the HIGH SEAS, or that operates beyond 3 miles from the coastline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2022
Resolution: Replaced the ERPIB in kind, cleared deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 April 2021
Resolved
(a) Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. The stbd engine room had water dripping into the space through a containment drain line on deck. Seal all water penetrations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: Vessel placed a ball valve on line leading to the bilge which was closed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 7 April 2021
Resolved
Placard was old and outdated due to reg changes. Install updated placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2021
Resolution: Vessel printed and pinned up updated garbage regulations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 April 2021
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Two exhaust mounts were cracked. Weld repair all cracked mounts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2021
Resolution: Exhaust hangers were gouged and re-welded.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 7 April 2021
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The hailing port was missing the “N” in “NOLA”. Permanently install letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2021
Resolution: Vessel permanently affixed N for hailing port.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 April 2021
Resolved
Piping must comply with regulations of this part. The fire monitor piping was missing the securing clamp and not secure. Install clamp to hold in place.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2021
Resolution: Vessel installed bracket to secure fire monitor.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2021
Resolved
a) Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. The port generator prime mover had a major fuel leak coming from the head. Coorect fuel leak iaw manufacturer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: Vessel replaced connection point causing excessive fuel leak.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 7 April 2021
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures. The procedures or the line diagram was not posted at the station. Install all required items.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2021
Resolution: Vessel created and placed transfer procedures near transfer pump and operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
Vessel's machinery shall be installed and maintained in a manner to afford adequate protection against fire. Vessel's #1 engine was observed to leak fuel oil on the port side. Cited 46 CFR 182.10-5.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2020
Resolved 10 March 2020
Resolution: Vessel Rep provided photo of work order to replace fuel brackets and fuel leak.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 March 2020
Resolved
Vessel's EPIRB must be registered with NOAA prior to installation and that information be kept up-to-date. Vessel's FCC callsign was incorrect on the Registration document. Cited 47 CFR 80.1061 (f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2020
Resolved 10 March 2020
Resolution: Vessel rep provided picture of new EPIRB Registration via email.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2020
Resolved
The vessel shall insure that the vessel is reasonably safe from fire caused by and/or originating in electrical equipment and reasonable safe from electrical shock of personnel. An electrical outlet on the bridge was observed to corroded and missing its cover plate. Cited 46 CFR 183.10-20 and 46 CFR 183.01-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2020
Resolved 10 March 2020
Resolution: Vessel rep provided picture on outlet that was replaced via email.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 March 2020
Resolved
The emergency broadcast instruction and information specific to the individual vessel must be placed next to all radiotelephone installations. Vessel did not have a placard on the forward radio station and was missing vessel specific information on the aft radio station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2020
Resolved 17 March 2020
Resolution: Vessel rep sent pictures of the emergency broadcast placards (fwd and aft) filled out and installed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 March 2020
Resolved
The vessel shall insure that the vessel is reasonably safe from fire caused by and/or originating in electrical equipment and reasonable safe from electrical shock of personnel. A power strip was observed in one of the staterooms. Cited 46 CFR 183.01-5 and 46 CFR 183.10-20.
Action required: 10 - Deficiency Rectified
Due 22 March 2020
Resolved 9 March 2020
Resolution: Vessel crewmember removed power strip from stateroom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
Fuel lines shall be effectively secured against excessive movement and vibration. The fuel line brackets holding the port side of #2 engine were missing and/or not securely attached. Cited 46 CFR 182.20-40 (b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2020
Resolved 10 March 2020
Resolution: Vessel Rep provided picture of work order to replace the fuel brackets via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
Fuel lines shall be protected from mechanical injury. Chaffing was observed on several flexible hoses on the #3 engine. Cited 46 CFR 182.20-40 (b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 10 March 2020
Resolution: Vessel Rep provided photo of chaffing protection for fuel lines via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 March 2020
Resolved
The vessel shall insure that the vessel is reasonably safe from fire caused by and/or originating in electrical equipment and reasonable safe from electrical shock of personnel. Port and Starboard generator windings were covered in oil and dust. Cited 46 CFR 183.01-5 and 46 CFR 183.10-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 10 March 2020
Resolution: Vessel rep provided pictures of winding and grates for generators via email.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 March 2020
Resolved
Vessel shall ensure that there are no unsafe practices, fire hazards, and other hazardous situations on board. The vessel was observed to have the lube oil sight material cut for the engine room and missing in the port side generator room tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 17 March 2020
Resolution: Vessel rep sent email with pictures showing sight glass for tanks replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2020
Resolved
Vessel shall maintain the Type II retro-reflective material on the vessel's ring life buoy IAW 46CFR164.018. Vessel had three ring life buoys that had the retro-reflective material scraped off and/or was not effective reducing the reflective material below the minimum size requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2020
Resolved 17 March 2020
Resolution: Vessel rep sent email showing new retroreflective tape intalled on life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2019
Resolved
LANYARD ATTACHING WATERLIGHT TO RING BUOY OVER 9' LONG; LINE REQUIRED TO BE 3-6' IN LENGTH; SHORTEN LINE TO APPROPRIATE LENGTH.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2019
Resolved 8 April 2019
Resolution: CREW SHORTENED LINE APPROPRIATELY TO SATISFACTION OF ATTENDING MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2019
Resolved
LAGGING ON GENERATOR EXHAUST IN ILL-REPAIR; NEEDED REPLACING TO ADEQUATELY PROTECT AGAINST HOT SURFACES. CITE 46 CFR 177.970 FOR TEMPERATURE REQUIREMENT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 April 2019
Resolved 8 April 2019
Resolution: CREW REPLACED ON THE SPOT TO THE SATISFACTION OF ATTENDING MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2019
Resolved
CHAFING GEAR ON MDE FLEXIBLE HOSE SPLIT AND NEEDED REPLACING TO ADEQUATELY PROTECT AGAINST DAMAGE; REPLACE AS APPROPRIATE TO PROTECT FLEXIBLE HOSE AND PROVIDE EVIDENCE TO ATTENDING MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2019
Resolved 6 May 2019
Resolution: Received email with pictures of corrected deficiency.
Communications › Alarms/Indicators › Fire Alarm
Issued 11 June 2018
Resolved
Multiple heat detectors in engine room need to be remounted and one requires reqiring due to wire being too short.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 June 2018
Resolved
Multiple main engines in engine room were missing exhaust lagging on exhaust.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 13 June 2018
Engineering › Steering Gear System › Ram
Issued 11 June 2018
Resolved
Steering ram pin was missing the retaining cotter pin.
Action required: 10 - Deficiency Rectified
Due 25 June 2018
Resolved 11 June 2018
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 11 June 2018
Resolved
Vessel did not have transfer procedures available at the transfer station. Post transfer procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 13 June 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 June 2018
Resolved
Battery in engine room was corroded. Clean battery connections at terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 13 June 2018
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 8 June 2018
Resolved
Liferafts were not installed correctly. Painter was not attached to weak link on hydrostatic release.
Action required: 10 - Deficiency Rectified
Resolved 8 June 2018
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 8 June 2018
Resolved
Vessel name and homeport were not painted on stern of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 11 June 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 June 2018
Resolved
Navigation light bases wasted on both side lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2018
Resolved 11 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2018
Resolved
Found multiple electrical issues. Wires in cable trays were spliced together with wirenuts in E/R. Extension cords used for permanent wiring. Inverters in bridge console not mounted or secured in place. Unapproved surge protector in use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Lifesaving › Line-Throwing Appliances › Lines
Issued 8 June 2018
Resolved
Vessel did not have auxillary line onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Stability › Unintentional Flooding › General
Issued 8 June 2018
Resolved
Vessel had excessive water in machinery room and main engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 8 June 2018
Resolved
Port Outboard Main Engine was leaking profusely on outboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Engineering › Sea-water System (primary cooling) › Pump
Issued 8 June 2018
Resolved
Raw water pump for air conditioning unit was not mounted, the stuffing tube for the electrical was missing, and the piping was secured in place with a wire tie.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 11 June 2018
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 8 June 2018
Resolved
Stbd outboard main engine Jacket water piping was leaking due to corrosion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 13 June 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 June 2018
Resolved
Vessel was not ready for inspection in the Hull, Machinery and Electrical systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 February 2018
Resolved
Heat detectors found disabled along with the panel at the pilot house. Provide proper operation of heat detectors and panel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2018
Resolution: Witnessed repairs of heat detectors and witnessed tests of all heat detectors by technician and verified alarms in engine room, generator room and panel at the pilot house, all sat.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 21 February 2018
Resolved
Prove adequate protection against overheating in the engine room and general fire hazards.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2018
Resolution: Witnessed completion of adequate lagging in engine room along with exhaust piping repairs and repairs to oil and fuel leaks, all sat.
Engineering › Fuel Oil Service System › Piping
Issued 7 July 2017
Resolved
Provide repairs to vital piping systems (fuel)
Action required: 60 - Rectify deficiencies prior to movement
Due 7 July 2017
Resolved 10 July 2017
Fire Fighting › Fire Main › Condition
Issued 7 July 2017
Resolved
Provide repairs to vital system piping (firemain)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 July 2017
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 6 July 2016
Resolved
#6 MDE exahust leaking, rep replacing wasted sections of exhaust.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2016
Resolution: Rep provided detaled pictures in lieu of inspector visiting vessel due to CG scheduling unavailability and isolated location.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 July 2016
Resolved
Packing glands on four(04) MDE drive shafts missing double nuts.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 6 July 2016
Resolution: Rep provided pictures of double nuts replaced on packing glands.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 July 2016
Resolved
Exhause hangers for two(02) MDE's missing retaining bolts.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 6 July 2016
Resolution: Rep provided pictures of hanger bolts replaced as necessary.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 July 2016
Resolved
Heat detector in engine room providing faulty signal.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 6 July 2016
Resolution: Rep provided service tech report. Tech found water in detector junction box shorting the sensor. Repaired and tested sat.