Records from 1991 to 2014. Most recent: operational control imposed, 20 August 2014.
Inspection history · 63
20 August 2014
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4960355
16 September 2011
Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4145709
15 September 2010
Random ISPS/MTSA/PSC
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3850310
22 February 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3683808
16 February 2010
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3680406
26 January 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3670130
25 January 2010
Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3669706
14 December 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3649709
21 July 2009
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3541267
10 July 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3531715
29 October 2008
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3353908
27 August 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3310071
13 August 2008
MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3297799
8 July 2008
Deficiency Check · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3261262
26 June 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3248796
17 September 2007
Type not recorded
No type recorded · Maritime Safety & Security Team Cape Cod (91110) · Activity 3060049
6 July 2007
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2986228
15 June 2007
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2962894
8 June 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2955174
23 April 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2913745
12 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2710600
14 June 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2679462
20 September 2005
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2496769
22 June 2005
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2399504
14 June 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2389979
24 May 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2368226
13 March 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2309398
8 November 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2237403
20 September 2004
PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2199941
15 June 2004
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2107978
11 February 2004
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2004917
29 August 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1890971
26 August 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1888155
29 July 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1860553
30 October 2002
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1698404
18 September 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1677016
19 June 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1633339
20 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1487676
16 September 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 293685
5 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 85272
7 September 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 281768
21 October 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 433800
20 October 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 434554
19 September 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 432822
12 October 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 421333
6 April 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 414471
7 October 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 496837
29 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396902
2 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 386153
6 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 378988
10 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 373996
4 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 447844
4 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 858443
9 March 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 495276
21 January 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 675685
7 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 480361
10 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 465250
6 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 492315
22 April 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 504379
7 February 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 507322
11 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 508272
13 July 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 470838
28 January 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341540
Fire Fighting › Fire Main › Condition
Issued 20 August 2014
Resolved
0799-Other(Fire Fighting Equipment)- When the pump is delivering the quantity of water required by paragraph 3.3.2.1, the pressure at any hydrant shall not the less than the minimum pressures given in paragraph 4.2. The PSCO observed multiple holes from excessive deterioration on the fire main producing a water flow with inadequate pressure to fight a fire onboard. -74SOLAS(97) II-2/4.3.3.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2014
Resolved 21 August 2014
Resolution: Cleared def. based on visual inspection by PSCO and Classification Society. Class report attached.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 15 September 2011
Resolved
Vessel was fitted with Reefer Alarms. Vessel's Meat Stores #1 was found with an inoperative alarm. SOLAS 74 Con 09 Ch. 1 Reg. 11
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 6 October 2011
Resolution: Class attended vessel and found deficiency was rectified and confirmed working. See attached class report.
Construction/Loadline › Structures › Door
Issued 15 September 2011
Resolved
The means of securing weathertight doors shall consist of gaskets and clamping devices or other equivalent means and shall be permanently attached to the bulkhead or to the doors themselves. Vessel has been found to have several weathertight doors that do not properly seal and wasted framing. Ann. I Ch. 2 Reg. 12 (1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 October 2011
Resolution: Class attended vessel and found all the weather tight doors have been examined, found recent maintenance done, with framing repaired, new gaskets and properly sealing and painted. They are considered satisfactory. See attached class report.
Operations/Management › Ballast Water Managment › Sediments
Issued 25 January 2010
Resolved
2199 - Other - All vsl equipped with bwt's that operate in the U.S. must remove fouling organisms from the hull, piping, and tanks. Large portions of the bow and stern were discovered to be extensively covered in dark green marine organisms. Vsl is to have the hull cleaned in accordance with local state and federal regulations prior to next U.S. port after sailing foreign. 33CFR151.2035(a)(6)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2010
Resolution: Conducted a Deficiency check for marine growth on the vessels hull. Hull has been cleaned of all algea in Gulf port and then re-painted in Moin Costa Rica. Deficiency cleared.
Operations/Management › Ballast Water Managment › Sediments
Issued 14 December 2009
Resolved
9900 - Master of vessels equipped w/ballast water tanks that operate in U.S. waters must remove fouling organisms from hull. It was noted that significant portions of the bow and stern were covered in algae. Vessel is to have class attest to the antifouling system currently in place prior to next U.S. Port after sailing foreign. 33CFR151.2035(a)(6)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 January 2010
Resolved 15 December 2009
Resolution: Sector Delaware Bay received copy of valid International Anti-Fouling System Certificate, endorsed by Lloyd''''s, from vessel.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 10 July 2009
Resolved
Ship service generator hand rails are missing or damaged
Due 9 August 2009
Resolved 21 July 2009
Resolution: Sector Delaware Bay conducted a follow up exam on M/V EUROS LIMA. Hand rails around the ship service generator were found in place and in good condition.
Documentation › Logs/Records › Oil Record Book
Issued 13 August 2008
Resolved
1710 - Oil Record Book - Upon inspection of oil record book, PSCO noted three seperate entries documenting oily water discharge through OWS exceeded max throughput of OWS as stated in IOPP, which is a max of 5 m3/HR. The entries read: 8/9/08 2200-0300 28.3 m3 was discharged; 8/11/08 0000-0400 21.8m3; 8/11/08 2300-0015 8.3m3 was discharged. MARPOL Cons. 2006 Annex I, Reg 17
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: ABS rectified throughput data and issued new IOPP.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 13 August 2008
Resolved
2545- Reports/ Analysis of non-compliance- When asked, the master was unable to explain or show PSCO non-conformity reporting requirements as per safety man. system. In addition, master was unable to explain or show reporting procedures for critical equipment. ISM Code Reg 5
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: New captain onboard with understanding of procedures for SMS.
Engineering › Fuel Oil Service System › Pump
Issued 13 August 2008
Resolved
1420 - Cleanliness of engine room - Upon inspection, lagging is missing or not properly affixed to flange coverings in oil purifier room. In addition, there was excessive oil soaked lagging around strainers. SOLAS Cons. 2004 CH. II-1, Reg. 26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: Lagging was replaced.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 13 August 2008
Resolved
1420 - Cleanliness of Engine Room - PSCO noted (3) 2 1/2 gallon buckets of fuel oil in oil purifier rooms which is a fire hazard. No explanation was provided as to why they were just sitting there and were not disposed of. SOLAS Cos. 2004 Ch. 1, Reg 11a
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: Buckets of fuel oil removed.
Lifesaving › Lifebuoys › Stowage
Issued 13 August 2008
Resolved
0699 - Other (Life Saving Appliances) - Bracket for lifering on starboard side midship is wasted and failing. Lifering is not supported as intended. SOLAS Cons. 2004 Ch. III, Reg 20.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 27 August 2008
Resolution: Lifering bracket has been repaired and painted. It has been properly reinstalled.
Engineering › Sea-water System (primary cooling) › Pump
Issued 13 August 2008
Resolved
0740 - Pumps - PSCO observed excessive leaking (2 G/MIN) on raw water pump, also observed excessive leaking of #1 main fire pump (2 G/MIN) in static position. SOLAS Cons. 2004 Ch. II-1, Reg. 26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: Pumps no longer leaking.
Engineering › Fuel Oil Service System › Hose
Issued 13 August 2008
Resolved
0750 - Fire Prevention - PSCO observed fuel oil dripping from second level main engine hoses onto main engine pit at fifth cylinder. SOLAS Cons. 2004 Ch. I, Reg. 11a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: Hoses no longer dripping oil.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 13 August 2008
Resolved
1420 - Cleanliness of Engine Room - Heavy fuel oil pump leaking oil so that containment has been coated with a thin coating of oil. SOLAS Cons. 2004 Ch.I, Reg. 11a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: Heavy fuel oil pump no longer leaking oil and containment cleaned up.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 13 August 2008
Resolved
1720 - Control of Discharge of Oil - During deck walk, observed fuel oil leaking from power pack/on deck generator set, which caused a thin layer of fuel in an area (12' x 1'). MARPOL 73/78 Annex I Reg. 1
Action required: 705 - Other - as specified
Resolved 14 August 2008
Resolution: Deck cleaned of thin oil area and generator set day tank connections are leak free.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 August 2008
Resolved
1730 - Oily Water Seperating Equipment - During MARPOL exam, PSCO asked for operations manual of OWS. No Ops manual was onboard. MARPOL 73/78 Annex I Reg. 14
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2008
Resolved 27 August 2008
Resolution: The oily water seperator manual has been located. The placard for the equipment has been ordered.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear, Timing
Issued 8 July 2008
Resolved
During the inspection of the engine room, PSC found 02 of 06 main generators to be inoperable. No. 5 diesel generator has a cracked crankshaft. No. 1 MDG has excessive vibrations and was tagged out. Both generators have been acknowledged by Class and are to be repaired. Vessel is to make repairs prior to next U.S. port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 July 2008
Resolution: Recieved Class report addressing the current status and condition of class for both generators.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 June 2006
Resolved
Fire Control Plan and Fire Control Plan Updates need to be approved by the Classification Society. SOLAS Ch. I Reg. 11
Due 14 July 2006
Resolved 11 July 2006
Resolution: Received verification of class survey.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 June 2006
Resolved
Class "A" bulkhead insulation is torn in the incinerator room next the incinerator control panel. Repair/Replace insulation to the satisfaction of the Classification Society. SOLAS CH. II-2 Reg 44
Condition: Improper/Lack of Maintenance
Due 14 July 2006
Resolved 11 July 2006
Resolution: Received verification of class survey
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 June 2006
Resolved
Overboard discharge pipe for the OWS is wasted with a hole. (currently taped). Repair/Replace to the satisfaction of the Classification Society. SOLAS Ch II-1 Reg. 3-1
Due 14 July 2006
Resolved 11 July 2006
Resolution: Received verification of class survey
Engineering › Freshwater Generation System › Pump
Issued 14 June 2006
Resolved
Fresh Water Pump is inoperable. Repair/Replace to the satisfaction of the Classification Society. SOLAS Ch. II-1 Reg. 3-1
Due 14 July 2006
Resolved 11 July 2006
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 14 June 2005
Resolved
#5 Main generator leaking excessive oil into containment. Cite: ILO 147
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 20 September 2005
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 14 June 2005
Resolved
#1 Heavy fuel oil transfer pump leaking excessive oil into containment. Cite: ILO 147
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 20 September 2005
Resolution: Corrected.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 20 September 2004
Resolved
THE DECLARATION OF INSPECTION WAS NOT PROPERLY FILLED OUT BY DESIGNATED PIC. DEFICIENCY WAS CORRECTED ON SPOT. CITE 33 CFR 156.150(a)
Condition: Improper/Lack of Maintenance
Due 20 September 2004
Resolved 20 September 2004
Resolution: DECLARATION OF INSPECTION WAS PROPERLY FILLED OUT BY PIC.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 20 September 2004
Resolved
(05) FOOD RATIONS HAD BROKEN AIR TIGHT SEALS. VESSEL MUST PROVIDE MSO PHILADELPHIA WITH A FAXED COPY OF A RECIEPT OF PURCHASE OF (05) FOOD RATIONS PRIOR TO DEPARTURE. CITE LSA CODE CH. IV 4.4.1.5.1.18
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2004
Resolution: Received faxed receipt from vessels agent for (06) new lifeboat rations.
Documentation › Logs/Records › Oil Record Book
Issued 20 September 2004
Resolved
Master's signature not on all pages of oil record book.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 September 2004
Resolved 20 September 2004
Resolution: Corrected on spot.
Communications › Radio Communications
Issued 26 August 2003
Resolved
Noted vessel's Navtex was inoperable. Must be replaced or repaired by a Certified Techician Prior to 29 AUG.03. LEGACY COMPONENT DESC: Satellite Communications Capability
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 29 August 2003
Resolution: RECIEVED FAX FROM G.A. INTERNATIONAL ELECTRONICS CORP. ATTESTING TO REPLACEMENT AND INSTALLATION OF NEW DEBEG 2900. TEST WAS CONDUCTED ON SYSTEM, ALL FUNCTIONS TESTED SATIFACTORY.
Lifesaving › Lifeboat Equipment
Issued 18 September 2002
Resolved
PORT LIFEBOAT FOUND WITH 5 RATIONS THAT WERE NOT VACUUM SEALED, A VIOLATION OF SOLAS 74/78 CH III REG 41/8.12. CORRECT PRIOR TO VESSEL DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2002
Resolved 19 September 2002
Resolution: VERIFIED CORRECT DURING FOLLOW UP EXAM. DEFICIENCY CLEARED.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 18 September 2002
Resolved
VESSEL'S EMERGENCY GENERATOR SWITCHBOARD WAS MISSING NON-CONDUCTIVE FLOORING, A VIOLATION OF SOLAS 74/78 CH II-1 REG 45/2. CORRECT PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2002
Resolved 19 September 2002
Resolution: VERIFIED CORRECT DURING DEFICIENCY FOLLOW UP EXAM. DEFICIENCY CLEARED.
Fire Fighting › Means of Escape › Doorways
Issued 18 September 2002
Resolved
VESSEL'S ENGINE ROOM EMERGENCY ESCAPE TRUNK DOORS WERE FOUND TO BE NOT SELF CLOSING, A VIOLATION OF SOLAS 74/78 CH II-2 REG 45/3.1. CORRECT PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2002
Resolved 19 September 2002
Resolution: VERIFIED CORRECT DURING DEFICIENCY FOLLOW UP EXAM. DEFICIENCY CLEARED.
Lifesaving › Lifeboat Equipment
Issued 18 September 2002
Resolved
PORT AND STARBOARD LIFEBOAT MISSING THE REQUIRED NUMBER OF SEASEACKNESS PILLS A VIOLATION OF SOLAS 74/78 CH. III REG 41/8.21 LEGACY COMPONENT DESC: Anti-seasickness Medicine
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2002
Resolved 19 September 2002
Resolution: ANTI-SEASICKNESS PILLS WERE RENEWED IN PORT AND STARBOARD LIFEBOATS DURING A DEFICIENCY FOLLOW UP EXAMINATION. DEFICIENCY CLEARED.
Fire Fighting › Fire Hoses › Connections
Issued 18 September 2002
Resolved
FIRE HOSE LOCATED ON B DECK OF VESSEL WAS FOUND HOLED AND CONNECTIONS IMPROPER IN VIOLATION OF SOLAS 74/78 CH II-2 REG 21.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2002
Resolved 19 September 2002
Resolution: FIRE HOSE AND CONNECTIONS RENEWED. REPAIR SATISFACTORY DURING A DEFICIENCY FOLLOW UP EXAMINATION. DEFICIENCY CLEARED
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 September 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2002
Resolved 19 September 2002
Resolution: VERIFIED PUBLICATION WAS CORRECTED DURING A DEFICIENCY FOLLOW UP EXAM, DEFICIENCY CLEARED.
Fire Fighting
Issued 7 September 2000
Resolved
Provide documentation from Administration stating when fixed CO2 bottles must be hydrostatically tested. SOLAS 74 (amended) II-2/5
Condition: Unknown
Due 20 November 2000
Resolved 20 November 2000
Engineering
Issued 7 September 2000
Resolved
Prove proper operation of oily water separator 15ppm sensor and alarm. Do not use separator in US waters until repaired. MARPOL 73/78 Annex I/16
Condition: Unknown
Due 20 November 2000
Resolved 20 November 2000
Fire Fighting
Issued 2 January 1996
Resolved
REPAIR DEFECTIVE FIRE HYDRANT VALVE IN WAY OF #2 CARGO HOLD PORT SIDE._x001C_ SOLAS 74 (AMENDED) II-2/21.
Condition: Unknown
Due 20 January 1996
Resolved 20 January 1996
Lifesaving
Issued 2 January 1996
Resolved
INSTALL LIGHTS AND WHISTLES TO LIFEJACKETS STOWED IN LOCKER UP IN FORECASTLE.SOLAS 74 (AMENDED) III/32.3
Condition: Unknown
Due 20 January 1996
Resolved 20 January 1996
Lifesaving
Issued 2 January 1996
Resolved
REPAIR/RENEW LIFEBUOYS THROUGHOUT SHIP.LIFEBUOYS NEED TO BE OF HIGHLY _x001C_ VISIBLE COLOR.SOLAS 74 (AMENDED) III/30.6
Condition: Unknown
Due 20 January 1996
Resolved 20 January 1996