MAURY USCG vessel records Sign in
← All vessels

AUTRY G.

AUTRY G. is a 1991 offshore supply vessel. The Coast Guard has recorded 31 inspections since 1991, most recently in December 2008, along with 36 deficiencies.

Records from 1991 to 2008. Most recent: inspection, 2 December 2008.

Built
1991
Last inspected
2 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9040572 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCV3164
358825
Flag
UNITED STATES
366746070 (licence lapsed)
Maury page id
psix-358825

Inspections, by type

…with no type recorded9
Years with a record 15 calendar years (1991–2008)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it86 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
288 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCV3164MMSI 366746070 · cancelled · voluntarily equipped · granted 23 March 1998, cancelled 7 March 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BOW PROSPER Tank Ship · MISLE 282031 · 27 May 2002 · activity 1626844

Inspection history · 31

2 December 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3372870
16 November 2004 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2242097
13 August 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2165444
8 March 2004 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2021307
29 January 2003 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1742301
27 May 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626844
20 February 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1488876
24 January 2002 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1480992
15 January 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1478899
11 January 2001 Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1444449
7 January 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466094
14 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771597
12 August 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 198559
23 February 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799815
27 January 1999 Type not recorded
No type recorded · CGC POINT BAKER · USCG Heartland District (CGD-H) · Activity 1509227
29 January 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378309
18 March 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091734
21 January 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1443804
25 January 1996 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463932
3 August 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760661
28 July 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196874
20 July 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753114
25 June 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 196872
20 January 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382897
14 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1147312
22 March 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1382723
1 February 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362709
18 February 1992 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1258515
11 June 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1309833
14 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 913029
25 January 1991 Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924949

Deficiency record · 36

Stability › Watertight Integrity
Issued 8 March 2004 Resolved
Watertight door to the engine room was latched open while the vessel was underway for drills.
Due 8 March 2004
Resolved 8 March 2004
Resolution: Recalled the recent OSV casualty in SW Pass Louisiana, reminded the crew that casualties happen suddenly and the importance of keeping the watertight door closed.
Engineering › Steering Gear System
Issued 8 March 2004 Resolved
2 cotter pins missing from hydraulic steering ram linkage. LEGACY COMPONENT DESC: Pin
Condition: Unknown
Due 8 March 2004
Resolved 8 March 2004
Resolution: Pins were inserted while I was on board during the inspection.
Lifesaving › Buoyant Apparatus
Issued 5 February 2003 Resolved
Attach oars to life floats with lanyards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 5 February 2003 Resolved
Repair/reinstall cover on exhaust stack.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 February 2003 Resolved
Reinstall hoses on fixed CO2 bottles. Provide service report from fire safety contractor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 5 February 2003 Resolved
Provide service report from mechanic on engine testing results.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Navigation
Issued 5 February 2003 Resolved
Provide current (2003) copies of required nautical publications.
Due 6 February 2003
Resolved 6 February 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 February 2003 Resolved
Replace expired medications and expired eye wash fluid.
Due 6 February 2003
Resolved 6 February 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 5 February 2003 Resolved
Secure laundry equipment for sea.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2003
Resolved 6 February 2003
Fire Fighting › Structural - A Class Divisions
Issued 5 February 2003 Resolved
Seal cable penetrations on forward engineroom bulkhead. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Engineering › Bilge Water Management System › Strainer
Issued 5 February 2003 Resolved
Install strainer on emergency bilge suction in engineroom.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Construction/Loadline › Structures
Issued 5 February 2003 Resolved
Install bars on freeing ports at 9" intervals.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 29 January 2003 Resolved
Demonstrate operation of emergency fuel stops.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Deck/Cargo › Cargo Transfer (solid)
Issued 24 January 2002 Resolved
Pump deck mount fractured not to be used until repaired or replaced. LEGACY COMPONENT DESC: deck mounts
Condition: Unknown
Due 21 February 2002
Resolved 20 February 2002
Resolution: New pump installed.
Deck/Cargo › Cargo Transfer (solid)
Issued 24 January 2002 Resolved
Reapir or replace cargo pump machinery guard. LEGACY COMPONENT DESC: machinery guard
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New machnery guard installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 January 2002 Resolved
Repair/replace RPM gauge on port engine. LEGACY COMPONENT DESC: rpm gauge
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New guage installed.
Engineering › Fuel Oil Service System
Issued 24 January 2002 Resolved
Renew flame screens on fuel vents as needed. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New vents installed
Electrical › Electrical Distribution System (service)
Issued 24 January 2002 Resolved
install blank cover on port switchboard panel board. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: Spacer installed.
Engineering › Compressed Air System (start air)
Issued 24 January 2002 Resolved
Install valve handle on engine room air reciever. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New valve handled installed.
Engineering
Issued 11 January 2001 Resolved
PLACE FLAME SCREEN ON BOW THRUSTER OIL RESERVOIR IN FWD HEAD.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Accommodation/Occupational Safety
Issued 11 January 2001 Resolved
PLACE FLAME SCREEN ON 'CHEMICAL' MSD VENT.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 11 January 2001 Resolved
CLEAN BILGE SUCTION STRAINER IN STBD RUDDER POST VOID.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Lifesaving
Issued 11 January 2001 Resolved
CLEAN AND REMOVE OLD PAINT FROM PAINT LOCKER.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Lifesaving
Issued 11 January 2001 Resolved
TAG OUT METHANOL PUMP IF NOT IN USE OR REMOVE FLAMMABLE MATERIAL FROM PUMP ROOM AND REPLACE GUARD ON PUMP SHAFT.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 11 January 2001 Resolved
WELD/RENEW CRACK IN STBD AFT VOID ON UNDER SIDE OF MAIN DECK NEAR MAINDECK RADIUS. CRACK IS A RESULT OF DEF. #0001.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Fire Fighting
Issued 11 January 2001 Resolved
PROVIDE CERTIFICATION FOR ALL REQUIRED FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 11 January 2001 Resolved
WELD/RENEW 2FT x 2FT SECTION OF 3/8IN PLATE AT STBD STERN TOPSIDE RADIUS OFAFT VOID WHERE MAINDECK AND SIDE PLATING MEET.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Engineering
Issued 11 January 2001 Resolved
PROVE PROPER OPERATION OF PORT MDE TACHOMETER.
Condition: Unknown
Due 26 January 2001
Resolved 25 January 2001
Fire Fighting
Issued 11 January 2001 Resolved
PROVIDE METHOD TO SEAL VENTS TO PAINT LOCKER AND METHANOL PUMP ROOM TO MEETFIXED FIREFIGHTING.
Condition: Unknown
Due 20 February 2002
Resolved 20 February 2002
Resolution: New vents installed.
Electrical
Issued 11 January 2001 Resolved
PROVE PROPER OPERATION OF PORT MAIN GENERATOR OVERSPEED.
Condition: Unknown
Due 26 January 2001
Resolved 25 January 2001
Navigation
Issued 11 January 2001 Resolved
REPLACE STERN TUBE BEARING KEEPER BOLTS.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Fire Fighting
Issued 23 February 1999 Resolved
Tighten packing to fire pump prime mover.
Condition: Unknown
Due 23 February 1999
Resolved 2 March 1999
Lifesaving
Issued 23 February 1999 Resolved
Replace galley outlets (2) near sink with GFI outlets.
Condition: Unknown
Due 23 February 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 23 February 1999 Resolved
Replace light bulb in crew's berthing "E" light.
Condition: Unknown
Due 23 February 1999
Resolved 2 March 1999
Navigation
Issued 21 January 1997 Resolved
REPAIR INOPERABLE RUDDER ANGLE INDICATOR. REQUIREMENT TO BE COMPLETED TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO 28 JAN 97._x001C_
Condition: Unknown
Due 28 January 1997
Resolved 3 February 1997
Navigation
Issued 21 January 1997 Resolved
MAKE NECESSARY REPAIRS TO RUDDER ASSEMBLY, TO ENSURE ASSEMBLY DOES NOT STRIKE INSTALLED RUDDER STOPS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO 21 FEB 97.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.