Records from 1991 to 2008. Most recent: inspection, 2 December 2008.
Inspection history · 31
2 December 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3372870
16 November 2004
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2242097
13 August 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2165444
8 March 2004
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2021307
29 January 2003
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1742301
27 May 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626844
20 February 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1488876
24 January 2002
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1480992
15 January 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1478899
11 January 2001
Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1444449
7 January 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466094
14 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771597
12 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 198559
23 February 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799815
27 January 1999
Type not recorded
No type recorded · CGC POINT BAKER · USCG Heartland District (CGD-H) · Activity 1509227
29 January 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378309
18 March 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091734
21 January 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1443804
25 January 1996
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463932
3 August 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760661
28 July 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196874
20 July 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753114
25 June 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 196872
20 January 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382897
14 December 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1147312
22 March 1994
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1382723
1 February 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362709
18 February 1992
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1258515
11 June 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1309833
14 March 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 913029
25 January 1991
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924949
Stability › Watertight Integrity
Issued 8 March 2004
Resolved
Watertight door to the engine room was latched open while the vessel was underway for drills.
Due 8 March 2004
Resolved 8 March 2004
Resolution: Recalled the recent OSV casualty in SW Pass Louisiana, reminded the crew that casualties happen suddenly and the importance of keeping the watertight door closed.
Engineering › Steering Gear System
Issued 8 March 2004
Resolved
2 cotter pins missing from hydraulic steering ram linkage. LEGACY COMPONENT DESC: Pin
Condition: Unknown
Due 8 March 2004
Resolved 8 March 2004
Resolution: Pins were inserted while I was on board during the inspection.
Lifesaving › Buoyant Apparatus
Issued 5 February 2003
Resolved
Attach oars to life floats with lanyards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 5 February 2003
Resolved
Repair/reinstall cover on exhaust stack.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 February 2003
Resolved
Reinstall hoses on fixed CO2 bottles. Provide service report from fire safety contractor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 5 February 2003
Resolved
Provide service report from mechanic on engine testing results.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Navigation
Issued 5 February 2003
Resolved
Provide current (2003) copies of required nautical publications.
Due 6 February 2003
Resolved 6 February 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 February 2003
Resolved
Replace expired medications and expired eye wash fluid.
Due 6 February 2003
Resolved 6 February 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 5 February 2003
Resolved
Secure laundry equipment for sea.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2003
Resolved 6 February 2003
Fire Fighting › Structural - A Class Divisions
Issued 5 February 2003
Resolved
Seal cable penetrations on forward engineroom bulkhead. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Engineering › Bilge Water Management System › Strainer
Issued 5 February 2003
Resolved
Install strainer on emergency bilge suction in engineroom.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Construction/Loadline › Structures
Issued 5 February 2003
Resolved
Install bars on freeing ports at 9" intervals.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 29 January 2003
Resolved
Demonstrate operation of emergency fuel stops.
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 6 February 2003
Deck/Cargo › Cargo Transfer (solid)
Issued 24 January 2002
Resolved
Pump deck mount fractured not to be used until repaired or replaced. LEGACY COMPONENT DESC: deck mounts
Condition: Unknown
Due 21 February 2002
Resolved 20 February 2002
Resolution: New pump installed.
Deck/Cargo › Cargo Transfer (solid)
Issued 24 January 2002
Resolved
Reapir or replace cargo pump machinery guard. LEGACY COMPONENT DESC: machinery guard
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New machnery guard installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 January 2002
Resolved
Repair/replace RPM gauge on port engine. LEGACY COMPONENT DESC: rpm gauge
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New guage installed.
Engineering › Fuel Oil Service System
Issued 24 January 2002
Resolved
Renew flame screens on fuel vents as needed. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New vents installed
Electrical › Electrical Distribution System (service)
Issued 24 January 2002
Resolved
install blank cover on port switchboard panel board. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: Spacer installed.
Engineering › Compressed Air System (start air)
Issued 24 January 2002
Resolved
Install valve handle on engine room air reciever. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 31 January 2002
Resolved 20 February 2002
Resolution: New valve handled installed.
Engineering
Issued 11 January 2001
Resolved
PLACE FLAME SCREEN ON BOW THRUSTER OIL RESERVOIR IN FWD HEAD.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Accommodation/Occupational Safety
Issued 11 January 2001
Resolved
PLACE FLAME SCREEN ON 'CHEMICAL' MSD VENT.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 11 January 2001
Resolved
CLEAN BILGE SUCTION STRAINER IN STBD RUDDER POST VOID.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Lifesaving
Issued 11 January 2001
Resolved
CLEAN AND REMOVE OLD PAINT FROM PAINT LOCKER.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Lifesaving
Issued 11 January 2001
Resolved
TAG OUT METHANOL PUMP IF NOT IN USE OR REMOVE FLAMMABLE MATERIAL FROM PUMP ROOM AND REPLACE GUARD ON PUMP SHAFT.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 11 January 2001
Resolved
WELD/RENEW CRACK IN STBD AFT VOID ON UNDER SIDE OF MAIN DECK NEAR MAINDECK RADIUS. CRACK IS A RESULT OF DEF. #0001.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Fire Fighting
Issued 11 January 2001
Resolved
PROVIDE CERTIFICATION FOR ALL REQUIRED FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 11 January 2001
Resolved
WELD/RENEW 2FT x 2FT SECTION OF 3/8IN PLATE AT STBD STERN TOPSIDE RADIUS OFAFT VOID WHERE MAINDECK AND SIDE PLATING MEET.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Engineering
Issued 11 January 2001
Resolved
PROVE PROPER OPERATION OF PORT MDE TACHOMETER.
Condition: Unknown
Due 26 January 2001
Resolved 25 January 2001
Fire Fighting
Issued 11 January 2001
Resolved
PROVIDE METHOD TO SEAL VENTS TO PAINT LOCKER AND METHANOL PUMP ROOM TO MEETFIXED FIREFIGHTING.
Condition: Unknown
Due 20 February 2002
Resolved 20 February 2002
Resolution: New vents installed.
Electrical
Issued 11 January 2001
Resolved
PROVE PROPER OPERATION OF PORT MAIN GENERATOR OVERSPEED.
Condition: Unknown
Due 26 January 2001
Resolved 25 January 2001
Navigation
Issued 11 January 2001
Resolved
REPLACE STERN TUBE BEARING KEEPER BOLTS.
Condition: Unknown
Due 23 January 2001
Resolved 25 January 2001
Fire Fighting
Issued 23 February 1999
Resolved
Tighten packing to fire pump prime mover.
Condition: Unknown
Due 23 February 1999
Resolved 2 March 1999
Lifesaving
Issued 23 February 1999
Resolved
Replace galley outlets (2) near sink with GFI outlets.
Condition: Unknown
Due 23 February 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 23 February 1999
Resolved
Replace light bulb in crew's berthing "E" light.
Condition: Unknown
Due 23 February 1999
Resolved 2 March 1999
Navigation
Issued 21 January 1997
Resolved
REPAIR INOPERABLE RUDDER ANGLE INDICATOR. REQUIREMENT TO BE COMPLETED TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO 28 JAN 97._x001C_
Condition: Unknown
Due 28 January 1997
Resolved 3 February 1997
Navigation
Issued 21 January 1997
Resolved
MAKE NECESSARY REPAIRS TO RUDDER ASSEMBLY, TO ENSURE ASSEMBLY DOES NOT STRIKE INSTALLED RUDDER STOPS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO 21 FEB 97.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997