BOW PROSPER

BOW PROSPER is a 1987 tank ship. The Coast Guard has recorded 81 inspections since 1987, most recently in July 2008, along with 24 deficiencies and 11 operational controls.

Records from 1987 to 2008. Most recent: inspection, 17 July 2008.

Built
1987
Last inspected
17 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8420476 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
282031
Flag
GREECE
—
Maury page id
psix-282031

Inspections, by type

…with no type recorded50
Years with a record 21 calendar years (1987–2008)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14842 - Convention (Subpart B), Net Ton
14842 - Regulatory (Subpart C or D), Net Ton
28001 - Convention (Subpart B), Gross Ton
28001 - Regulatory (Subpart C or D), Gross Ton
45661 - Dead Weight, Metric Ton
57854 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE HENRY Towing Vessel · MISLE 92883 · 23 April 2006 · activity 2631282JAMES R MORAN Towing Vessel · MISLE 690475 · 23 April 2006 · activity 2631282IB 961 Tank Barge · MISLE 54770 · 5 November 2004 · activity 2242935PAIGE GERTRUDE Towing Vessel · MISLE 174603 · 5 November 2004 · activity 2242935AUTRY G. Offshore Supply Vessel · MISLE 358825 · 27 May 2002 · activity 1626844

Inspection history · 81

17 July 2008 ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3269764
11 April 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2905478
6 April 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2902790
30 March 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898577
30 March 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898714
25 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2809735
20 October 2006 MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2804399
31 July 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2732237
5 July 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2701738
26 May 2006 MARPOL Annex I Examination · ISPS II Exam · COC-TVE Annual · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2659927
25 April 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2633339
23 April 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2631282
21 April 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2630298
21 April 2006 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2630315
17 April 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2626512
8 November 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2527910
9 October 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2510915
8 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2510356
24 April 2005 ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew · MARPOL Annex II Examination · Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2340438
5 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242935
2 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2233841
1 July 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2117243
24 June 2004 MTSA/ISPS Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2109354
14 March 2004 Certificate of Compliance · Letter of Compliance (Initial/Renewal) · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2024227
21 May 2003 Type not recorded
No type recorded · Station Bellingham · USCG Northwest District (CGD-NW) · Activity 1798262
16 May 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1794956
29 January 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1737095
29 January 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1737124
24 January 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1735133
21 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734649
17 January 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1732059
30 September 2002 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1682169
26 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1680636
9 June 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1630587
7 June 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1632283
5 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1627496
5 June 2002 Security Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1629451
27 May 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626844
30 January 2002 Annual Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1482827
30 May 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 290512
12 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280803
5 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274300
5 February 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1453712
16 September 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 458868
14 April 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 427503
10 November 1998 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 64277
2 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423192
2 November 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809032
19 May 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 520469
15 November 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 409929
9 October 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 408654
9 October 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1109980
6 June 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1109670
17 August 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 394625
16 August 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1085702
9 March 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 388786
17 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379630
9 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 647292
7 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379102
7 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 876496
20 October 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 371474
10 June 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 367555
6 June 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394132
5 June 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 518263
28 December 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 828556
23 December 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 832693
18 December 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139823
30 January 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348361
17 January 1992 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1313999
19 November 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940347
18 March 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1240928
18 December 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 907046
13 December 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 487462
24 July 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331622
24 July 1989 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1031822
16 July 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 520878
10 February 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 516386
4 September 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 325338
4 September 1988 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1209780
24 February 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 470265
12 July 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 317280

Deficiency record · 24

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 30 March 2007 Resolved
IGS IS CURRENTLY INOPERABLE. REQUEST CLASS REPORT UPON REPAIR. 70A SOLAS 74 II-2 REG. 55
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2007
Resolution: Received class report and verified IGS during cargo operation.
Communications › Radio Communications › Satellite Communications Capability
Issued 30 March 2007 Resolved
VESSELS NAVTEX IS OPERABLE, RECEIVEING ALL WEATHER AND NAVIGATIONAL REPORTS VIA INMARSAT-C. 70a SOLAS 74 II-1 REG. 7/1.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2007
Resolution: Recieved Class report. All sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 March 2007 Resolved
BALLAST PUMPROOM FAN IS INOPERABLE. REQUEST CLASS REPORT. 70a SOLAS 74 II-1 REG 35
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2007
Resolution: New fans installed. All sat.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 30 March 2007 Resolved
The cargo tank pressure meters that display in the cargo control room are unreliable. 17a SOLAS 74 II-2/16
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2009
Documentation › Logs/Records › Logbook (official)
Issued 30 March 2007 Resolved
The maintenance records for the N2 generator is missing the hour and differential pressures for the filters and membranes as required by the manufactures instructions. 70a ISM code 10.2.4 &10.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2007
Resolution: Logs currently updated. All Sat.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 30 March 2007 Resolved
The N2 generator is not able to supply sufficient quantity of oxygen deficient gas to keep up with the cargo pump. 17a SOLAS 74 II-2/60.1
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2007
Resolved 13 April 2007
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 October 2006 Resolved
Vessel's Secondary Marine Radar inoperable prior to entering port. Inbound Deviation was granted.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2006
Resolved 27 October 2006
Resolution: Received technicians report attesting to satisfactory repairs.
Navigation › Piloting/Steering › Swing Meter
Issued 25 October 2006 Resolved
Vessel's Rudder Angle Indicator inoperable prior to entering port. Inbound Deviation was granted.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2006
Resolved 27 October 2006
Resolution: Received technicians report attesting to satisfactory repairs.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 26 May 2006 Resolved
NITROGEN GAS GENERATOR HEATER IS DEFECTIVE. VSL MUST MAKE PERMANENT REPAIRS PRIOR TO LOADING CHEMICAL CARGOES
Action required: 705 - Other - as specified
Due 29 June 2006
Resolved 5 July 2006
Resolution: Received a class report of permanent repair to nitrogen generator.
Engineering › Fuel Oil Service System › Valve
Issued 21 April 2006 Resolved
Vessel to have class (DNV) conduct survey of main fuel oil (MFO) service tank valve F201V to prove proper operation of quick closing mechanism and valve seating. Accidental closure of valve could cause loss of MFO pressure and shut down of vital systems.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 April 2006
Resolution: Received class report via fax attesting to proper repairs of the main fuel oil (MFO) service tank valve.
Lifesaving
Issued 5 February 2000 Resolved
UNSATISFACTORY FIRE, LIFE BOAT/RESCUE BOAT DRILLS.
Condition: Unknown
Due 6 February 2000
Resolved 7 February 2000
Deck/Cargo
Issued 5 February 2000 Resolved
NOT ABLE TO PROVIDE CERTIFICATE OF ANALYSIS OF NITROGEN CALIBRATION BOTTLE AND PROPER USE.
Condition: Unknown
Due 6 February 2000
Resolved 7 February 2000
Navigation
Issued 2 November 1998 Resolved
AUTO PILOT ALARM OR OVERIDE NOT INSTALLED._x001C_ _x001C_ 33 CFR 157.440
Condition: Unknown
Due 1 February 1999
Resolved 10 December 1998
Lifesaving
Issued 9 October 1997 Resolved
RELEASE CABLES STBD SIDE LIFEBOAT IS KINKED. SOLAS 74 REG III/19.2
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Documentation
Issued 7 June 1995 Resolved
VESSEL DID NOT HAVE ONBOARD THE ORIGINAL CERTIFICATE OF FINANCIAL RESPONSIBILITY THAT WAS ISSUED TO THE VESSEL ON 27FEB95 AS REQUIRED BY 33 C.F.R. 130.9(b). CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 18 June 1995
Resolved 18 June 1995
Documentation
Issued 7 June 1995 Resolved
Class to ensure that proper loadling cert reflecting actual location of plimsel is onboard prior to hadnling cargo in next US port.
Condition: Unknown
Due 18 June 1995
Resolved 18 June 1995
Fire Fighting
Issued 7 June 1995 Resolved
Provide COTP San Juan with servicing certificates for liferafts and portable fire extinguishers prior to departure from Guayama, PR.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Navigation
Issued 7 June 1995 Resolved
VESSEL ENTERED THE PORT OF GUAYAMA WITH AND INOPERABLE RADAR WITHOUT NOTIFICATION TO THE US COAST GUARD. RADAR MUST BE REPAIRED PRIOR TO VESSEL'S DEPARTURE.
Condition: Unknown
Due 18 June 1995
Resolved 18 June 1995
Construction/Loadline
Issued 7 June 1995 Resolved
Ensure loadline plimsels are painted in contrasting color to hull.
Condition: Unknown
Due 18 June 1995
Resolved 18 June 1995
Documentation
Issued 7 June 1995 Resolved
VESSEL ENTERED THE PORT OF GUAYAMA WITHOUT A LETTER OF DEVIATION FOR AN INOPERATIVE RADAR. VSL MUST REPORT ALL FUTURE FAILURES TO THE NEAREST COTPPRIOR TO ENTERING US WATERS.
Condition: Unknown
Due 18 June 1995
Resolved 18 June 1995
Deck/Cargo
Issued 23 December 1992 Resolved
PROVIDE A CLASS SOCIETY APPROVED LIST OF CARGOS AUTHORIZED FOR COLLECTION VIA THE VAPOR COLLECTION SYSTEM. THE CLASS SOCIETY APPROVAL HAS BEEN PROVIDED FOR THE CARGO ETHYLENE DICHLORIDE, EDC.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Deck/Cargo
Issued 23 December 1992 Resolved
PROVIDE A CLASS SOCIETY APPROVED CALCULATIONS AND REQUIREMENTS IAW 46CFR39.30-1.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Documentation
Issued 23 December 1992 Resolved
VESSEL SHALL NOT UTILIZE THE VAPOR RECOVERY SYSTEM FOR THE COLLECTION OF CARGO VAPORS, EXCEPT ETHYLENE DICHLORIDE, UNTIL OIL TRANSFER PROCEDURES WHICH HAVE BEEN AMENDED IAW 33CFR155.750(d) ARE PROVIDED. THE AMENDED OIL TRANSFER PROCEDURES MUST BE APPROVED BY THE CLASS SOCIETY.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Deck/Cargo
Issued 4 September 1988 Resolved
MAKE REPAIRS AND PROVE OPERATION OF THE INERT GAS SYSTEM TEMPERATURE GAUGE LOCATED ON THE IGS PANEL IN THE ENGINE CONTROL ROOM UPON ENTERING NEXT U.S.PORT.
Condition: Unknown
Due 4 September 1988
Resolved 4 September 1988

Ownership record