SEASTREAK NEW JERSEY

Built
2001
Last inspected
24 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8968272
WDE4029
Flag
UNITED STATES
Maury page id
psix-35953

Documentation record

Registered dimensions (L × B × D)130.6 ft × 34.3 ft × 11.1 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)130.6 ft × 34.3 ft × 11.1 ft
ITC tonnagegross 417 / net 156
BuilderGLADDING-HEARN SHIPBLDG · SOMERSET, MA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portATLANTIC HIGHLANDS, NJ
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it417 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
156 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

24 June 2026 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8412801
18 May 2026 Internal Structural Exam · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8374883
10 March 2026 TPO Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8323598
21 May 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8139931
2 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8012975
13 June 2024 Internal Structural Exam · Annual Inspection · MTSA/ISPS Verification · Drydock Extension
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7933854
11 May 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7910366
6 December 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7834661
6 June 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704370
12 April 2023 Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7667452
27 June 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7488838
21 October 2021 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7337021
28 September 2021 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7319603
24 September 2021 In-Service Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7318802
5 August 2020 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7025576
8 July 2020 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999265
16 June 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974041
16 April 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6940057
20 December 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6878079
26 October 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6673221
30 January 2018 COI Inspection · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346864
24 May 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154496
23 September 2016 COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6004889
27 May 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888230
26 May 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5887556
20 May 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881804
12 May 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5874983

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2025 Resolved
unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle , waste receptions must be non combustible materials with no openings several plastic waste receptacles onboard, replace. 46 CFR 116.405(i)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2025 Resolved
Fire hoses must be/conform to UL19 or recognized by the commandant fire station hose had a pen hole, replace. 46 cfr 118.320(b)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of repairs made.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 May 2025 Resolved
Vesse must carrya a first aid kit that meets the requirements...first aid kit had expired aspirin replace. 46 CFR 121.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of new meds.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 May 2025 Resolved
Each inflatable liferaft must have one of the following equipment packs as shown by the markings on the container, SOLAS A or SOLAS B liferaft markings are not legible. 46 cfr 117.175(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 5 August 2025
Resolution: Received and accepted emailed photo of repairs made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew and the vessel from electrical hazards. Void 3 starboard side bilge junction box was missing cover. starboard laz. MSD pump junction pump junction box not secured. 46 CFR 121.200(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of repairs made.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2025 Resolved
Vessel control system,s and other misc. systems and equipment required by this part must be suitable for purposes intended. Starboard MSD pump not properly mounted. 46 cfr 121.100(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of repairs made.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 June 2024 Resolved
A devise must be provided to automatically shut down power ventilation serving the protected space. Port fire dampener louvers not actuating or closing properly. *to continue to operate the vessel shall keep the port side firedampener closed. 46 CFR 118.410(b)(10) - 705 (c) Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 24 June 2024
Resolution: Prior to Credit Drydock. *to continue to operate the vessel shall keep the port side fire dampener closed. - recieved video of sat repair
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2024 Resolved
Portable fire extinguishers installation and location to satisfaction of [name withheld] 10 Portable extinguisher installation height in no case shall the clearance between thtebottom of the hand portable fire extinguisher and the floor be less than 4 inches. All extinguishers installed onboard are touching the deck or are installed less than 4 inches from the deck. - 46 CFR 118.520 NFPA 10 CH.6.1.3.9.3 - 705 (c) Prior to Credit Dry Dock.
Action required: 705 - Other - as specified
Resolved 22 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2024 Resolved
Reported MDE shut-down due Loss L/O Press Alarm & high L/O level w/ fuel dilution. Submit failure / repair report and verify repairs test sat to MI satisfaction prior to pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Accepted evidence of causal analysis, repair report, & sat op trial.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2021 Resolved
Public spaces that may be assumed to be occupied by a large number of persons when passengers are on board need be served by a manual alarm system that meets part 76 in sub-chapter H of this chapter. The fire detection and alarm system must notify crew and passengers of a fire when appropriate. Visual alarm in accommodation spaces occupied by passengers inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 September 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. High level bilge alarm panel indicates fault.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 September 2021 Resolved
The discharge ends of of fuel tank vent pipes must be fitted with flame screens of at least 30 x 30 mesh. Flame screens of greater size than required by regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2021 Resolved
Each connection to a conductor must be made within an enclosure. Sewage pump wiring exposed in port jet room. Exposed wiring outside of enclosure in same space, as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 3 November 2021
Resolution: Received Satisfactory photos of covers.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 September 2021 Resolved
A vessel must comply with applicable requirements for radios, including certificates issued by the FCC, as set forth in 47 CFR 80. Vessel's MMSI number does not match MMSI number displayed on radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 September 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041, or a kit with equivalent contents and instructions. First-aid kit did not include tourniquet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 28 September 2021 Resolved
Whenever damage to hull plating or structural members that may affect the seaworthiness of the vessel is discovered, OCMI may require repair. Starboard side bitt, forward of amidship found fractured at the base.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 8 July 2020 Resolved
MI identified fire control plan is not posted. Fire control plan must be posted. Cite: 46CFR116.530
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 8 July 2020
Resolution: Observed posting of fire control plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2020 Resolved
MI observed a ground. Vessel must isolate and identify ground. Cite: 46CFR120.370 Action: 705; rectify within one week
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 23 July 2020
Resolution: Attending marine inspector verified proper repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 July 2020 Resolved
MI identified trouble light on vessel's fire control panel. Vessel must service fire control panel IAW manufacturer's reccommendations. Cite: 46CFR115.840 Action: 705; Rectify within one week
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 23 July 2020
Resolution: Attending marine inspector verified proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020 Resolved
MI observed fuel leak on port engine. Correct fuel leak on port engine. Cite: 46CFR119.200 Code: 705; Rectify within one week
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 23 July 2020
Resolution: Attending marine inspector verified proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020 Resolved
Causal analysis report must be submittted to CG for review for STBD engine failure shen able and completed. Cite: 46CFR119.200(a) Action: 705; Rectify when completed.
Action required: 705 - Other - as specified
Due 3 September 2020
Resolved 22 October 2021
Resolution: Attended vessel, verified 835 for outstanding casual analysis signed by MI.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.