Documentation record
Registered dimensions (L × B × D)130.6 ft × 34.3 ft × 11.1 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)130.6 ft × 34.3 ft × 11.1 ft
ITC tonnagegross 417 / net 156
BuilderGLADDING-HEARN SHIPBLDG · SOMERSET, MA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portATLANTIC HIGHLANDS, NJ
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it417 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
156 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
24 June 2026
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8412801
18 May 2026
Internal Structural Exam · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8374883
10 March 2026
TPO Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8323598
21 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8139931
2 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8012975
13 June 2024
Internal Structural Exam · Annual Inspection · MTSA/ISPS Verification · Drydock Extension
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7933854
11 May 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7910366
6 December 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7834661
6 June 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704370
12 April 2023
Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7667452
27 June 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7488838
21 October 2021
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7337021
28 September 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7319603
24 September 2021
In-Service Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7318802
5 August 2020
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7025576
8 July 2020
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999265
16 June 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974041
16 April 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6940057
20 December 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6878079
26 October 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6673221
30 January 2018
COI Inspection · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346864
24 May 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154496
23 September 2016
COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6004889
27 May 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888230
26 May 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5887556
20 May 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881804
12 May 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5874983
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2025
Resolved
unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle , waste receptions must be non combustible materials with no openings several plastic waste receptacles onboard, replace.
46 CFR 116.405(i)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2025
Resolved
Fire hoses must be/conform to UL19 or recognized by the commandant fire station hose had a pen hole, replace.
46 cfr 118.320(b)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of repairs made.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 May 2025
Resolved
Vesse must carrya a first aid kit that meets the requirements...first aid kit had expired aspirin replace.
46 CFR 121.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of new meds.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 May 2025
Resolved
Each inflatable liferaft must have one of the following equipment packs as shown by the markings on the container, SOLAS A or SOLAS B liferaft markings are not legible.
46 cfr 117.175(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 5 August 2025
Resolution: Received and accepted emailed photo of repairs made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew and the vessel from electrical hazards. Void 3 starboard side bilge junction box was missing cover. starboard laz. MSD pump junction pump junction box not secured.
46 CFR 121.200(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of repairs made.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2025
Resolved
Vessel control system,s and other misc. systems and equipment required by this part must be suitable for purposes intended. Starboard MSD pump not properly mounted.
46 cfr 121.100(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: Received and accepted emailed photo of repairs made.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 June 2024
Resolved
A devise must be provided to automatically shut down power ventilation serving the protected space. Port fire dampener louvers not actuating or closing properly. *to continue to operate the vessel shall keep the port side firedampener closed. 46 CFR 118.410(b)(10) - 705 (c) Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 24 June 2024
Resolution: Prior to Credit Drydock. *to continue to operate the vessel shall keep the port side fire dampener closed. - recieved video of sat repair
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2024
Resolved
Portable fire extinguishers installation and location to satisfaction of [name withheld] 10 Portable extinguisher installation height in no case shall the clearance between thtebottom of the hand portable fire extinguisher and the floor be less than 4 inches. All extinguishers installed onboard are touching the deck or are installed less than 4 inches from the deck. - 46 CFR 118.520 NFPA 10 CH.6.1.3.9.3 - 705 (c) Prior to Credit Dry Dock.
Action required: 705 - Other - as specified
Resolved 22 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2024
Resolved
Reported MDE shut-down due Loss L/O Press Alarm & high L/O level w/ fuel dilution. Submit failure / repair report and verify repairs test sat to MI satisfaction prior to pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Accepted evidence of causal analysis, repair report, & sat op trial.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2021
Resolved
Public spaces that may be assumed to be occupied by a large number of persons when passengers are on board need be served by a manual alarm system that meets part 76 in sub-chapter H of this chapter. The fire detection and alarm system must notify crew and passengers of a fire when appropriate. Visual alarm in accommodation spaces occupied by passengers inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 September 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. High level bilge alarm panel indicates fault.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 September 2021
Resolved
The discharge ends of of fuel tank vent pipes must be fitted with flame screens of at least 30 x 30 mesh. Flame screens of greater size than required by regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2021
Resolved
Each connection to a conductor must be made within an enclosure. Sewage pump wiring exposed in port jet room. Exposed wiring outside of enclosure in same space, as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 3 November 2021
Resolution: Received Satisfactory photos of covers.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 September 2021
Resolved
A vessel must comply with applicable requirements for radios, including certificates issued by the FCC, as set forth in 47 CFR 80. Vessel's MMSI number does not match MMSI number displayed on radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 September 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041, or a kit with equivalent contents and instructions. First-aid kit did not include tourniquet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 28 September 2021
Resolved
Whenever damage to hull plating or structural members that may affect the seaworthiness of the vessel is discovered, OCMI may require repair. Starboard side bitt, forward of amidship found fractured at the base.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 22 October 2021
Resolution: Attended vessel, verified sat repairs.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 8 July 2020
Resolved
MI identified fire control plan is not posted. Fire control plan must be posted.
Cite: 46CFR116.530
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 8 July 2020
Resolution: Observed posting of fire control plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2020
Resolved
MI observed a ground. Vessel must isolate and identify ground.
Cite: 46CFR120.370
Action: 705; rectify within one week
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 23 July 2020
Resolution: Attending marine inspector verified proper repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 July 2020
Resolved
MI identified trouble light on vessel's fire control panel. Vessel must service fire control panel IAW manufacturer's reccommendations.
Cite: 46CFR115.840
Action: 705; Rectify within one week
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 23 July 2020
Resolution: Attending marine inspector verified proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020
Resolved
MI observed fuel leak on port engine. Correct fuel leak on port engine.
Cite: 46CFR119.200
Code: 705; Rectify within one week
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 23 July 2020
Resolution: Attending marine inspector verified proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020
Resolved
Causal analysis report must be submittted to CG for review for STBD engine failure shen able and completed.
Cite: 46CFR119.200(a)
Action: 705; Rectify when completed.
Action required: 705 - Other - as specified
Due 3 September 2020
Resolved 22 October 2021
Resolution: Attended vessel, verified 835 for outstanding casual analysis signed by MI.