Inspection history · 44
27 May 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8382085
19 August 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8213423
8 May 2025
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8134839
8 May 2025
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8135723
6 May 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8121278
10 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8317399
20 May 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7898280
17 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7896355
31 August 2023
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7782272
31 August 2023
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7895690
22 August 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7675311
8 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7668741
24 August 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7504367
9 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7443132
27 May 2022
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7460552
15 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7431784
21 October 2021
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7337014
17 August 2021
Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7290045
17 August 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7425719
10 December 2020
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7109428
20 November 2020
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7100616
15 November 2020
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7095920
15 November 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7097031
5 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7072163
27 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961589
29 November 2019
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6865245
17 October 2019
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6820009
21 June 2019
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6721364
17 June 2019
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6704635
25 May 2019
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6693035
24 May 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6816588
11 February 2019
Deficiency Check · Damage Survey · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6623851
11 February 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6623923
27 November 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6586479
28 September 2018
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6550887
10 September 2018
Commercial Dive Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6543845
18 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6339499
28 July 2017
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6221207
13 July 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6207704
24 May 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154528
28 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048237
13 October 2016
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6021220
27 May 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888233
11 May 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881806
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2026
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Flame screens have holes in them on the fuel vents. Replace flame screens.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 22 June 2026
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 19 August 2025
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type: a space containing propulsion machinery. The fire alarm system in the engine room was found to be inoperable during the inspection with no audible or visual alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2025
Resolved 28 August 2025
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 August 2025
Resolved
Each vessel must be equipped with a public address system that is audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. The speakers at the port and starboard wing stations were found to be non-operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2025
Resolved 28 August 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 August 2025
Resolved
Each door used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The handle on the port side aft passenger door on the second deck was found to be broken, preventing proper egress.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2025
Resolved 28 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's port engine experienced alarm and automatic shutdown due to cracked valve cover. Conduct damage survey and repairs prior to teh satisfaction of the attending USCG marine inspector. 46CFR 199.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Engine repaired with OEM equipment. Successful sea trials. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2024
Resolved
Repair to Prop Damage.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 November 2024
Resolution: Vessel Rep submitted report of damage repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 May 2024
Resolved
A hatch on a watertight trunk that extends at least 12" above the weather deck must be weathertight. Approximately 2" of gasket material was missing from the weathertight hatch to the port side engine room. Apply serviceable gasket to the affected area.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: Gasket applied prior to departure from the vessel.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 May 2024
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where vapors are present, such as machinery spaces. Cable run penetrations between port and starboard side engine rooms and electrical closets missing barrier sealant. Make both penetrations vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: Fire barrier sealant applied and vapor tightness maintained.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 May 2024
Resolved
Each survival craft must be stowed so that when the vessel sinks it floats free and if inflatable, inflates automatically. Both starboard side IBAs were incorrectly attached to their float free links. Corretly attach both starboard side IBAs to their respective float-free links.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: Crew correctly attached IBA painters to their float-free links.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) provide services necessary for safety under normal and emergency conditions. An unused extension cord was connected to its power source and extended to the bilge in the port fuel void. Remove the hanging electrical extension cord from the fuel void.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 June 2022
Resolved 9 June 2022
Resolution: The crew removed the hanging extension cord from the port fuel void.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) minimize accidental personnel contact with energized parts. The electrical junction box for the steering gear in the starboard lazarette was missing a fastening screw and was unsecured. Install appropriate hardware and make the component secured and safe for crew.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2022
Resolved 9 June 2022
Resolution: The crew installed the appropriate hardware and made the component safe for working around.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) provide services necessary for safety under normal and emergency conditions. The capstan control box in the port forward void was locked in the open position, unable to close without a key, and unsecured, causing the door to swing freely in a corrosive environment. Secure the capstan control box and allow it to close properly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2022
Resolved 9 June 2022
Resolution: The crew secured the capstan control box and allowed it to close.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 June 2022
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in 4.03-2 in subchapter A of this chapter shall comply with the requirements of 4.06 in Subchapter A of this chapter. The vessel was not outfitted with alcohol testing strips per the operator's testing protocol. Procure or outfit the vessel with the means required to conduct post-casualty testing per the operator's testing procedures.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2022
Resolved 9 June 2022
Resolution: The operator provided a procurement receipt from Pharmatech, indicating the purchase of the alcohol testing swabs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2022
Resolved
A vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. The diameter of the mouth of the bell shall not be less than 300 mm for vessels of 20 meters or more in length. SEASTREAK NANTUCKET EXPRESS had no appropriately sized bell available for inspection. Provide and install a bell of appropriate construction and size, and make available for inspection by a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 20 June 2022
Resolution: Operator submitted photographs of new, serviceable 12" bell, and installed the component on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 June 2022
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests: (2) For semi-portable and fixed gas fire extinguishing systems, the inspections and tests required by Table 115.810(b), in addition to the tests required by 147.60 and 147.65. The vessel's April 21, 2022 fixed CO2 fire extinguishing report from Firex, Inc. noted that "the cylinders are in poor condition and must be replaced within the next year." The vessel's fixed CO2 fire extinguishing cylinders must be hydrostatic tested or replaced to the satisfaction of the Coast Guard prior to its next (2023) annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2023
Resolved 8 May 2023
Resolution: Sea Safety Services, Inc. conducted hydrostatic testing in February and April 2023 of the four fixed CO2 bottles.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Vessel experienced a small 110v outlet failure, followed by smoke. The circuit is to be tagged out and not used. Determine cause, and affect repairs to the satisfaction of the Coast Guard Marine Inspector. 46CFR120.200 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: The outlet's receptacle(s) wore and gave way to electrical prongs not fitting snugly, which allowed current to jump the gap. The 110-VAC receptacle was replaced with a serviceable component and tested with a voltmeter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2021
Resolved
Vessel must make satisfactory repairs to the stbd engine prior to carriage of passengers. Additionally, the vessel must conduct a sea trail with CGMI in attendance.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2021
Resolved 22 October 2021
Resolution: Attended vessel and conducted sea trial; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 November 2020
Resolved
Conduct temporary repair on port quarter damage prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 December 2020
Resolution: Attending marine inspector verified satisfactory permanent repair.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 November 2020
Resolved
Vessel sustained damage to port quarter while backing out of a slip. The damage shall be inspected by a CG marine inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2020
Resolution: Inspected damaged area.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 October 2020
Resolved
Improper structural fire protection around cable penetrations in port & stbd electrical closet. Repair at next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2020
Resolved 10 December 2020
Resolution: Installed proper fire protection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020
Resolved
Electrical penetration at top of the #3 stbd void is not watertight. Repair at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2020
Resolved 10 December 2020
Resolution: Repaired penetration
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020
Resolved
Repair position indicator plugs in port & stbd lazarettes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 15 October 2020
Resolution: Plugs reinserted and epoxied into place
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020
Resolved
Non-conductive mat missing in stbd electrical closet by the switchboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Non-conductive mat placed at switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020
Resolved
Dead end wiring not properly enclosed in port lazarette.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Dead end wires placed in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 5 October 2020
Resolved
Air conditioning fan guards have holes/corrosion. Repair at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2020
Resolved 10 December 2020
Resolution: Replaced fan guards
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020
Resolved
Stbd engine room compressor drains directly into outlet. Redirect drain away from outlet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Hose clamped onto compressor and drains to bilge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2019
Resolved
Replace F/O vent screen for stbd F/O tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 29 November 2019
Resolution: Observed new F/O vent screen on both port and stbd F/O vents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Remove dead end cable in stbd E/R fwd by panel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 29 November 2019
Resolution: Observed dead end cable in junction box.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 October 2019
Resolved
Repair cracked welds to base of upper hand rail post on aft stbd stair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 29 November 2019
Resolution: Observed repair of welds to base of upper hand rail post on aft stbd stair.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 October 2019
Resolved
Repair crack on port side rudder stop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 29 November 2019
Resolution: Observed repair of cracked weld on port side rudder stop.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 October 2019
Resolved
Conduct U/W drills.
46 CFR 122.520 and 46 CFR 122.524
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 29 November 2019
Resolution: Observed satisfactory completion of U/W drill.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2019
Resolved
Hydraulic ram mount sheared off base. Repair and prove proper operation of port side steering.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2019
Resolution: Vessel rep. repaired steering gear. Conducted uderway sea-trial to prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2019
Resolved
Missing 05 life jackets. Passenger count reduced to 494 until 05 life jackets are replaced and marked with vessels name.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 29 May 2019
Resolution: Vessel rep. replaced 5 life jackets marked with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2019
Resolved
Fwd life jacket box is missing a latch. Provide latch for box.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 29 May 2019
Resolution: Vessel rep. replaced latch on life jacket box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2019
Resolved
GT01: Prepare and submit a repair plan for the starboard propeller for review and approval prior to starting any work.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2019
Resolution: Vessel provided repair plan
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2019
Resolved
GT02: Due to the loss of the starboard engine, vessel must provide a service report for casualty analysis and conduct sea trials to the satisfaction of an attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
Resolution: Sea trial conducted.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 February 2019
Resolved
GT03: Fire stop located in the cable runs that penetrate the deck in the port and starboard electrical closets must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
Resolution: New fire stop added
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2019
Resolved
GT05: Electrical heater located in the port side potable water space needs to have a grounding pole.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 20 February 2019
Resolution: Heater removed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2018
Resolved
RL01: Vessel is stowing unauthorized misc items throughout the main deck that were not included in the fire load calculations. Vessel is to relocate items to authorized locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 26 October 2018
Resolution: Recieved photographic evidence of removed items throughout the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2018
Resolved
RL02: A hydrualic line located on the starboard MDE is severly chafed and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 26 October 2018
Resolution: Recieved photographic evidence of newly installed hydrualic line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2018
Resolved
Vessel must have MI witness safe operation of machinery (sea trials) prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2018
Resolved 10 September 2018
Resolution: Conducted succesful sea trials.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 13 July 2017
Resolved
Port engine suffered a intake valve failure on the right bank cylinder B6. Cylinder head requires replacement.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Conducted sea trials after repairs, all parameters within manufacturer's recommendations.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 13 October 2016
Resolved
Vessel's switchboard is showing a significant amout of unwanted current (8 amps). Vessel must locate the cause of this unwanted current and make proper repairs.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 21 October 2016
Resolution: Vessel proved no unwanted ground to hull and that the amp meter for ground detection is bad. Vessel to replace with a digital model that was previously approved in 2015 by this office.
Stability › Watertight Integrity › General
Issued 13 October 2016
Resolved
Make cable penetration in fwd laz blkhd watertight.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 21 October 2016
Resolution: Vessel filled cable penetration with fire block.
Construction/Loadline › Hull › Hull Plating
Issued 13 October 2016
Resolved
Submit proposal and make repairs to the following areas: welds at 2nd Frame centerline fm transom IWO longitudinal girder, portside eng rm, aft blkhd above gen exhaust and portside laz fwd blkhd weld.
Action required: 705 - Other - as specified
Resolved 16 November 2016
Resolution: Vessel made proper repairs to structural defects.
Fire Fighting › Fire Pumps › Arrangement
Issued 13 October 2016
Resolved
Repair or replace inop fire pump gauge.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 21 October 2016
Resolution: Vessel replaced gauge and proved proper operation.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 October 2016
Resolved
Replace all retro reflective material on exterior life rings.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 21 October 2016
Resolution: Vessel replaced all worn reflective material.