Professional
The full record for this vessel
Behind this panel: 23 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
8 April 2026
PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8344773
6 November 2025
Type not recorded
No type recorded · USCGC KIMBALL (WMSL 756) · Activity 8265441
4 November 2025
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8250621
12 May 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8133586
26 February 2025
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8080452
25 February 2025
COE-Administrative
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8080453
6 August 2024
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7961531
18 July 2024
COE-Administrative
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7961579
2 October 2023
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7799578
5 April 2023
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7660586
21 February 2023
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7639885
7 February 2023
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7632933
12 June 2022
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7475221
21 January 2021
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7124781
24 April 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6943450
3 March 2020
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6914675
4 April 2019
Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6648980
10 September 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6534957
6 March 2018
Type not recorded
No type recorded · USCGC DOUGLAS MUNRO (WHEC 724) · Activity 6382356
20 January 2018
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6390584
26 December 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6327624
23 January 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6076162
19 April 2016
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5854545
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2025
Resolved
74SOLAS(97)II-2/20.2
In all ships a duplicate set of fire control plans or a booklet containing such plans shall be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for the assistance of shoreside fire fighting personnel. PSCO observed fire control plan to be in poor condition.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2025
Resolution: At the request of owner, occasional survey for verification and rectification of deficiency was carried out in accordance with the deficiencies which had been pointed out by USCG at Dutch Harbor, AK, USA on 26 Feb 2025. Defs were cleared by NKK.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 February 2025
Resolved
74SOLAS(97)II-2/12.1.1
Any required automatic sprinkler, fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. PSCO observed smoke detector not working above the fuel purifier when tested. Crew changed out detector and was tested satisfactorily.
Action required: 10 - Deficiency Rectified
Resolved 26 February 2025
Resolution: Crew changed out faulty smoke detector and tested it satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 August 2024
Resolved
The Machinery shall be of a a design and constroction adequate for the service for which they are intended and shall be so installed and protected as to reduce to minimum any damage to persoon on board.
Emergency fire pump did not have protection over the drive belt.Guarding must be added to limit risk to operator.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 August 2024
Resolution: Chief engeneer installed guard to machinery prior finishing the inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 6 August 2024
Resolved
05AUG24 - Cylinders when not in use must be stowed with the valve protection cap in place. Oxygen and acetylene gas cynlenders do not have the protection cap.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 September 2024
Resolution: Received Class Survey Report verifying caps were installed on Oxygen and Acetylene tanks.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2023
Resolved
When the emergency fire pump is delivering the quantity of water required by paragraph 3.3.2.1 (not less than 25m^3/h), the pressure at any hydrant shall not be less than the minimum pressure given in paragraph 4.2 (with the following minimum pressure of 0.25N/mm^2; cargo ships 1000 gross tonnage and upwards but under 6000 gross tonnage); emergency fire pump onboard provided approximately 0.138 N/mm^2 which does not meet the minimum standard. Current draft conditions of vessel at time of exam: 4.4m forward, 4.8m aft.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2023
Resolution: Vessel provided Class Report and examiners witnessed testing of the firepump and was found to be in compliance.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2020
Resolved
Electric lines must be double insulated. Multiple electric lines on main engine and ship service generator were exposed and not properly insulated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 24 April 2020
Resolution: CLASS REPORT RECEIVED