Records from 2005 to 2026. Most recent: inspection, 11 August 2026.
Inspection history · 27
11 August 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8461468
20 July 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8442669
5 March 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8320381
16 February 2026
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8311126
9 February 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8308280
9 December 2025
Administrative Inspection · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8281429
23 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8257792
5 September 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8229197
10 June 2025
Examination of Repairs · Drydock Exam · Administrative Inspection · Construction Oversight · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8156707
20 July 2024
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7962869
11 July 2024
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7964297
2 July 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7943715
7 December 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7836763
28 September 2023
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7800406
5 July 2023
Annual Inspection · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7733796
15 June 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7715840
17 June 2022
Internal Structural Exam · Drydock Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7483088
28 September 2021
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7318832
18 August 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7036459
6 August 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7025768
27 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6789695
28 November 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6587856
1 May 2017
COI Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6136403
1 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5989618
29 July 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5956867
7 July 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5933132
6 July 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5933361
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 June 2025
Resolved
A vessel must have a valid stability letter issued by the the Commanding Officer, Marine Safety Center. Vessel Stability letter is pending following modifications and an incline exam on conducted on 27AUG25. Vessel is limited to 20 Total Persons allowed in while operating as a small passenger vessel or existing offshore supply vessel while stability is under MSC review.
Action required: 705 - Other - as specified
Resolved 14 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2024
Resolved
Each fixed power bilge pump must be self priming. Bilge pump unable to remove water from bilges.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 September 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Inspection found inability to de-water spaces. Affect necessary repairs and prove to the attending marine inspector that all spaces fitted with installed bilge suction can be de-watered.
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Witnessed proper operation of installed bilge system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 September 2023
Resolved
All mattresses must comply with the U.S. Department of Commerce "Standard for Mattress Flammability" (FF 4-72.16, 16 CFR PART 1632 and not contain polyurethane foam. Inspection found all mattresses were 100% polyurethane foam and rated to 16 CFR PART 1633.
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Witnessed removal of mattresses from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2022
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and float-free link.
Replace missing Float-free link on the 2-12 man life floats(port side).
*Vessel restricted to carrying 36 passengers until float free link is installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 13 July 2022
Resolution: Picture Rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 June 2022
Resolved
Each hatch cover must have securing device. Add/replace broken securing devices on flush mounted hatches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 13 July 2022
Resolution: Picture Rectification.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 August 2020
Resolved
Provide proof of enrollment in Drug and Alcohol Program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2020
Resolution: Verified crew enrolled in DAPI Program
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 August 2020
Resolved
Provide pins for vent covers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2020
Resolution: Witnessed ventilation closures for E/R.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 August 2020
Resolved
Witness operational test of bilge pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2020
Resolution: Witnessed satisfactory test of bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 August 2019
Resolved
Vessel failed to provided servicing documentation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 10 September 2020
Resolution: Vessel has life floats installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2019
Resolved
Vessel's bridge control engine stops failed to secure MDE's as installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 9 September 2020
Resolution: Witnessed satisfactory bridge control engine stops.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 November 2018
Resolved
VESSEL MISSED ANNUAL INSPECTION. VESSEL MUST CONDUCT INSPECTION IN A TIMELY MANNER.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 29 November 2018
Resolution: DEFICIENCY IS CORRECTED.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 November 2018
Resolved
VESSEL MUST HAVE A GREEN LIGHT ON THE STARBOARD SIDE. VESSEL'S STARBOARD SIDE GREEN LIGHT IS EXTINGUISHED.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 29 November 2018
Resolution: DEFICIENCY IS CORRECTED.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 November 2018
Resolved
A VESSEL NOT UNDER COMMAND SHALL EXHIBIT: TWO ALL-ROUND RED LIGHTS IN A VERTICAL LINE WHERE THEY CAN BEST BE SEEN. THE TOP RED LIGHT IS EXTINGUISHED.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 29 November 2018
Resolution: DEFICIENCY IS CORRECTED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
EACH SURVIVAL CRAFT EQUIPMENT MUST BE OF GOOD QUALITY, AND EFFICIENT FOR THE PURPOSE IT IS INTENDED TO SERVE. THE PORTSIDE, TOP LIFE FLOAT MUST BE REMOVED FROM THE VESSEL PRIOR TO DEPARTURE. MANNING IS NOW REDUCED FROM 62 TO 50. THE VESSEL IS NOT AUTHORIZED TO CARRY MORE THAN 50 PEOPLE ON BOARD.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 29 November 2018
Resolution: DEFICIENCY IS CORRECTED.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 29 June 2017
Resolved
Straps on Life Floats are degrading on a few that needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 December 2017
Resolved 26 October 2017
Resolution: Straps were corrected.
Operations/Management › Drills/Instruction › Fire
Issued 29 June 2017
Resolved
Drills Not Conducted
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 December 2017
Resolved 9 September 2020
Resolution: Witnessed satisfactory fire and man-overboard drills.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 29 July 2016
Resolved
FCC Bridge-to-Bridge Certificate expired 01MAY16.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 2 August 2016
Resolution: Received new certificate
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 29 July 2016
Resolved
Waste Management Plan does not designate PIC
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 2 August 2016
Resolution: Updated plan
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 29 July 2016
Resolved
Could not shutoff main diesel engines from operating station
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2016
Resolved 2 August 2016
Resolution: Repaired remote shutdowns
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 July 2016
Resolved
Lagging missing around exhaust piping on all 4 engines near engine block
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 31 August 2016
Resolution: Lagging placed around exhaust piping
Engineering › Pressure Vessel › Pressure Gauge
Issued 29 July 2016
Resolved
Pressure gauges on 2 PVs need replacing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 1 May 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 July 2016
Resolved
Emergency lighting in aft storage compartment inefficient for egress
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2016
Resolved 3 August 2016
Resolution: Emergency lighting sufficient for space
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 July 2016
Resolved
Broken T-handle for remote fuel shutoff
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2016
Resolved 2 August 2016
Resolution: Replaced T-handle
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 July 2016
Resolved
Backup chart not corrected or up-to-date
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 2 August 2016
Resolution: Electronic chart meets the requirement
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 29 July 2016
Resolved
Battery cases contained oil/liquid and needed to be cleaned out
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 2 August 2016
Resolution: Battery cases cleaned of oil/liquids
Lifesaving › Lifefloat › Lifeline
Issued 29 July 2016
Resolved
Lifelines on lifefloats needed to be replaced or re-spliced and secured
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2016
Resolved 2 August 2016
Resolution: Lifelines repaired and re-spliced
Construction/Loadline › Hull › Side Shell
Issued 7 July 2016
Resolved
Vessel damage on port side of bow with 2 horizontals on starboard side of forepeak and stem beam
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 28 July 2016
Resolution: Repairs satisfactory to Marine Inspector