MAURY USCG vessel records
← All vessels

CARNIVAL ECSTASY

Built
1991
Last inspected
18 October 2022
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 October 2022
…with no type recorded17
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8711344
362733
Flag
LIBERIA
Maury page id
psix-362733

Documentation record

Tonnage as PSIX records it70526 - Convention (Subpart B), Gross Ton
44557 - Convention (Subpart B), Net Ton
35670 - Displacement, Ton
6600 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 55 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 55

18 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579424
27 September 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7568016
15 August 2022 PSC B · COC-CVE Quarterly
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7530871
24 July 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7515081
22 June 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7448391
5 May 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7484337
22 April 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7436084
21 April 2022 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429689
14 March 2022 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7411431
28 February 2022 COC-CVE Annual · PSC A · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7400852
9 November 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7348049
5 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935672
9 March 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6922991
6 February 2020 Deficiency Check · COC-CVE Annual · PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6892583
1 February 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6900879
27 January 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6897019
13 January 2020 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6888230
9 January 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6886763
8 January 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6885339
30 December 2019 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6880746
16 December 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6875227
23 November 2019 In-Service Inspection · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6860941
2 October 2019 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6826187
5 September 2019 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6819933
19 August 2019 COC-CVE Quarterly
Type not classified · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6788648
25 July 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6762673
30 May 2019 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6699395
20 February 2019 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6621090
6 August 2018 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6502786
21 June 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6455518
16 June 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6450321
7 June 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6843568
14 April 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6394832
21 February 2018 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6357790
15 September 2017 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6263425
9 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6235062
22 July 2017 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6217039
18 May 2017 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6149526
5 May 2017 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6139663
23 February 2017 Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6090973
18 February 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6096339
27 January 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6078358
25 January 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6077711
5 January 2017 NPV Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6066334
16 November 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6042455
17 September 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6005752
29 August 2016 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5981840
7 May 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5872332
26 March 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5845443
9 March 2016 Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5828321
17 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5817375
16 February 2016 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5815588
18 January 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5799110
15 January 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5797965
1 January 2016 NPV Safety Exam · ISM Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5789632

Deficiency record · 28

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 February 2022 Resolved
The following tests and inspections shall be carried out weekly: all survival craft, rescue boats, and launching appliances shall be visually inspected to ensure that they are ready for use. PSCOs observed hole and failed repair in the port side rescue boat hull, rendering it unavailable for use. SOLAS 97 III/19.6.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
Resolution: RO approved plan to use Lifeboat as alternate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 February 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea. PSCOs observed air leak through WTD 211. SOLAS 14 I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
Resolution: Resolved on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 February 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs identified small leak on vessel's EDG jacket water cooling system. SOLAS 04 I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Witnessed operational test of emergency generator with no leaks detected. O-Rings renewed to jacket water cooling piping connections
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 28 February 2022 Resolved
Survival craft muster and embarkation arrangements. Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation I/42. PSCOs observed multiple extinguished embarkation lights on the stbd side. SOLAS 97 III/11.4
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Received RO report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 February 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel's #4 SSDG experienced turbo failure. SOLAS 04 I/11
Action required: 705 - Other - as specified
Due 28 May 2022
Resolved 21 April 2022
Resolution: MI witnessed No. 4 Generator running with no issues. Uploaded service report from ABB into Activity no. 7429689.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 February 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Stbd side lifeboats #7 and #17 do not operate as designed due to shaft and propeller issues. SOLAS 97 III/19
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Witnessed propulsion testing of No.7 and No.17 life boats in all modes. Maitenance was conducted on shaft couplings by ships crew. No unusual noises were observed during the testing that would preclude the operation of both life boats.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 November 2021 Resolved
...must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's BWMS is out of commission, vessel is not authorized to discharge ballast into the waters of the United States. 33CFR151.2025(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 13 January 2022
Resolution: BWMS fixed, new International Ballast Water Management Certificate provided.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2020 Resolved
Fire doors in main vertical zone bulkheads shall be self-closing. observed the following FSDs did not fully close: 358, 633, 735, 923, 1240. 74SOLAS(97) II-2/30.4.1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: Class tested FSDs and observed the doors fully close. Noted that FSD 1240 does not exist, assumed it was 1204 and it was tested and observed fully closing.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2020 Resolved
Fire doors shall have an approximately uniform closure rate of no more than 40 seconds and not less than 10 seconds. Observed the following FSDs close too fast: 535, 639, 850. 74SOLAS(97)II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: Class tested FSDs and found closure rate acceptable.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 February 2020 Resolved
Means of control shall be provided for the closure of ventilator dampers. Observed the following dampers did not close: 70701, 71009, 71010, 71011, 71012, 71112, 71108, 71109, 1005, and 1002. 74SOLAS(81)II-2/11.4.1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: Class tested fire dampers and observed them fully closing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea. Observed an air leak through WTD B-212. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: Ship crew replaced the door frame seals and class operated the closure of the WTD. Class noted that the doors are not designed to be air tight, but will be water tight under a head of water pressure.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 6 February 2020 Resolved
Manually operated call pointes shall be capable of manual operation at all times. Manual call points 161-7 was found not operational. 74SOLAS(97)II-2/13.1.1.1 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 February 2020
Resolved 6 February 2020
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 February 2020 Resolved
Fire-fighting systems and appliances shall be kept in good working order. Sprinkler head in electrical workshop on deck 02 showed signs of a slow water leak as evidence by high amounts of salt accumulation in the sprinkler head. 74SOLAS(14)II-2/14.2.1.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: Sprinkler head was replaced with new and class did not observe any leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2020 Resolved
Terminations in all conductors shall be made as to retain the original electrical properties of the cable. PSCO identified dead end wire in ventilation space on deck 10 port side, posing an electrical hazard. 74SOLAS(04)II-1/45.5.6
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: Class noted that the correct deck was 11 port aft, Fan room space and found that loose wire was adequately secured and protected.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 February 2020 Resolved
The following basic principles must be followed: ship shall maintain the ready availability for fire-extinguishing appliances. Door knob to fire locker 205 not operational. 74SOLAS(97)II-2/2.2.7 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2020
Resolved 10 February 2020
Resolution: PSCO observed door know to fire locker 205 working properly.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 13 January 2020 Resolved
All passenger ships shall be fitted with an echo-sounding device, or other electronic means, to measure and display the available depth of water. The master reported that while using the vessel’s bow thruster during mooring or unmooring evolutions, the installed echo-depth sounder sometimes does not display or accurately measure depth of water. 74 SOLAS (14) V/2.3.1, 16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 27 January 2020
Resolution: RO powered off and removed AC from the unit, allowed 30 sec before connecting AC and applying power. Systems came on without error and showed current chartered depth.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2019 Resolved
Vessels equipped with ballast tanks that operate in U.S. waters must employ ballast water management methods approved by the U.S. Coast Guard. Vessel has an approved USCG ballast water management system #162.060/2/3. Ballast water tank #8 port piping was not modified as designed which by passed the treatment system after the intake of ballast water. 33 U.S.C. 1221/ 33 CFR 151.2025/ 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2019
Resolved 10 February 2020
Resolution: Received new International BWM Certificate and technical report. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 19 August 2019 Resolved
Each device must be vented or provided with a means to prevent an explosion or over pressurization as a result of an accumulation of gases. PSCE's noticed high level H2S in sewage space/ engine room while conducing walk-through making the space a hazardous condition/ environment for crewmembers/ workers. Additionally, port sewage tank hatch cover found leaking and studs missing. Starboard sewage tank pipes showed signs of leaking at weldments and pinholes. *To be verified upon vessel return to Jacksonville by USCG on 26AUG2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2019
Resolved 26 August 2019
Resolution: USCG verified proper risk management from vessel to include: Safety Engineer will check the sewage room and surrounding hallways of the sewage room, before personnel start working, and on regular intervals, provide ppl working in the space w/ gas monitors
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 August 2018 Resolved
1499- Other - The Elecrical Power available shall sufficient to supply all those service that are essential for saftey event of emergency. The ship ecemerncy generator was found leaking coolant. the vessel has an additional service generator that meets all requirment of SOLAS II-1/42. Class on board attested addition generator as tempory replacement until the main emergency generator is repaired. SOLAS 2014 II-1/Reg 42
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: Received class report attesting to the repairs.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 22 July 2017 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. The vessel reported a failure of the scrubber system on 21JUL17 from 1940 to 2137. SOLAS 04 Ch.II-1 Reg. 26.1 16 a
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 31 July 2017
Resolution: Class attested to the sensor being cleaned and put back in operation.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 22 July 2017 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm in the ECR. The alarm notified the crew when the scrubber failed but the crew failed to act. Requested audit from the RO. SOLAS 04 II-1 Reg. 51.1.1 16 a c
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 31 July 2017
Resolution: Class attested to new procedures and training being conducted.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 22 July 2017 Resolved
When ships operate within the ECA, the sulphur content of the fuel oil used on board shall not exceed 0.10% m/m. With the scrubber not operating the vessel did not meet the Annex VI requirements. MARPOL [name withheld] Reg. 14.4.3 10c
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 22 July 2017
Resolution: Vessel has the scrubber back up and running.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 18 May 2017 Resolved
THE MACHINERY SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVISE FOR WHICH THEY ARE INTENDED. THE VESSEL REPORTED A FAILURE OF THE SCRUBBER SYSTEM ON 08 MAY 2017. THE SYSTEM WAS DOWN FOR 4.5 HOURS. 74 SOLAS (04) II-1/ REG. 26.1
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 7 June 2017
Resolution: Received Class report attesting to proper operation.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 18 May 2017 Resolved
AN ALARM SYSTEM SHALL BE PROVIDED INDICATING ANY FAULT REQUIRING ATTENTION AND SHALL BE BAPABLE OF SOUNDING AN AUDIBLE ALARM IN THE MAIN MACHINERY CONTROL ROOM. THE ALARM SYSTEM DID NOT NOTIFY THE CREW WHEN THE SCRUBBER SYSTEM FAILED ON 08 MAY 2017. REQUEST AUDIT FROM RO. 74 SOLAS (04)/ II-1/ REG. 51.1.1
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 7 June 2017
Resolution: Received Class report attesting to proper operation.
Operations/Management › Pollution › Changeover Not Completed Prior to ECA
Issued 18 May 2017 Resolved
WHILE SHIPS ARE OPERATING WITHIN AN EMISSION CONTROL AREA, THE SULPHUR CONTENT OF FUEL OIL USED ON BOARD SHALL NOT EXCEED 0.10% M/M. WITH THE EGC (SCRUBBERS) NOT OPERATING THE VESSEL DID NOT MEET ANNEX VI REQUIREMENTS. MARPOL ANN. VI/ REG. 14.4.3
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 May 2017
Resolution: Once the system was energized, the vessel was in compliance.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 5 January 2017 Resolved
The #3 Ship Service Diesel Generator lost power during the vessel's transit into port. The fuel filter to the generator was clogged during the fuel switch from Heavy Fuel Oil to Low Sulfur diesel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2017
Resolution: Teh fuel filters for SSDG 3 and SSDG4 were cleaned. Proper operation of the generators was verified by Class Surveyor.
Engineering › Electric Propulsion System › Circuit Breaker (overload/over current protection)
Issued 18 January 2016 Resolved
The condition of the ship and its equipment will remain fit to proceed to sea without danger to the ship or persons on board. The #1 MDE propulsion motor breaker is defective affecting normal safe operation of ship.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 18 January 2016
Resolution: Vessel replaced defective breaker with spare operational breaker onboard. All operational test of the propulsion system were tested from engine room control and the bridge.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 15 January 2016 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The halon cylinder on deck 3 port side near the economizer emptied for unknown reason.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 29 August 2016
Resolution: vessel replaced halon cylinder