Records from 2002 to 2026. Most recent: inspection, 1 July 2026.
Documentation record
Registered dimensions (L × B × D)195.0 ft × 35.0 ft × 12.0 ft
Registered tonnagegross 687 / net 687
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE-PORT ALLEN · PORT ALLEN, LA, UNITED STATES
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it687 - Simplified, Gross Ton
687 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
1 July 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8421494
11 June 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8158506
10 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7931752
13 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7713862
17 June 2022
Cargo Tank Internal · MTSA Verification · COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7480202
12 November 2021
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7348701
24 June 2020
Annual Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6985789
31 March 2020
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6933626
15 October 2019
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6835067
15 October 2019
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6835070
25 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6632130
13 February 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6625130
2 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6279606
1 September 2017
Annual Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6256960
24 August 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5981891
4 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5849436
25 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5821967
27 August 2015
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5227889
22 August 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4962611
24 July 2013
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4663204
26 June 2012
Administrative Inspection · COI Inspection · Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4357126
28 February 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4252531
16 August 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4117197
5 June 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3788893
1 July 2009
Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3520504
9 July 2008
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3262762
2 May 2008
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3197485
9 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3180784
6 August 2007
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3019484
9 July 2007
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2989700
3 August 2006
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2735309
30 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2504758
31 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480318
19 August 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2467239
11 August 2004
Re-Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2162858
16 July 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1848306
7 August 2002
Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1657904
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 August 2022
Resolved
Cargo pump pressure gauge shall be tested at least once a year for accuracy. Documentation for Pressure gauges on cargo/VCS piping was unavailable for inspection.
46CFR35.35-70(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2022
Resolution: Recieved reviewed and accepted documentation and photo verification of cargo pressure gauge.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 5 August 2022
Resolved
The boundaries of regulated areas must be indicated by barricades, other devices, or by painted areas on the vessel. A sign bearing the following legend, must be posted at each access to the regulated area. No signage for the vessels benzene program was posted. Post signage prior to cargo operations.
46CFR197.501
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2022
Resolution: Recieved reviewed and accepted photo verification of cargo pressure gauge.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 November 2021
Resolved
If damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Weld on stern of the vessel was corroded to the point that it had a hole.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2022
Resolution: Conducted air tests and inspected satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 February 2019
Resolved
Vsl missed annual inspection window.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 20 February 2019
Resolved 25 February 2019
Resolution: Completed satisfactory annual inspection
Engineering › Gasoline Engine (auxiliary) › Alternator (4 cycle)
Issued 9 April 2008
Resolved
07 Apr 2008: Sister barge (CBR 2301) was inspected and found to have a new alternator with out the proper UL listing it as intrinsically safe. It appears to be an automotive type. Barge POC states that all 3 of his barges had just had the same alternator installed. Limited to grade E cargoes untill inspected by MI.
Condition: Improper Installation
Due 7 May 2008
Resolved 2 May 2008
Resolution: Correct alternator installed.
Construction/Loadline › Structures › Rake
Issued 9 July 2007
Resolved
A small inset was found in the bow rake requiring an insert. The attached angle iron was also damaged and needed to be cut out and replaced.
Due 9 August 2007
Resolved 3 August 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 July 2007
Resolved
The prime mover was missing a guard over a section of rotating machinery.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 July 2007
Resolved
The navigation light screens were not painted flat black.
Due 9 August 2007
Resolved 9 August 2007