Records from 1992 to 2025. Most recent: inspection, 12 August 2025.
Documentation record
Registered dimensions (L × B × D)45.1 ft × 20.1 ft × 7.3 ft
Registered tonnagegross 62 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHRIFT SHPBLDG & REPAIR · SULPHUR, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Regulatory (Subpart C or D), Gross Ton
42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 38
12 August 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8208553
16 September 2024
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8003704
22 August 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7997760
6 November 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7823929
8 November 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7591204
16 November 2021
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7351981
15 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7078049
25 April 2020
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6943763
12 February 2019
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6624323
23 August 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6250433
24 March 2014
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4821783
16 January 2014
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4787163
19 December 2013
Deficiency Check · Marine Casualty Follow Up
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4772138
19 December 2013
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4772157
14 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4343665
6 June 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4341983
5 June 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3788893
11 August 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3033852
25 August 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2763298
19 August 2005
MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2533250
25 April 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2342062
19 January 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 722851
15 November 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213573
19 October 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 124527
12 April 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 128024
6 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 60781
23 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 8965
2 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 4746
11 June 1997
Uninspected Towing Vessel
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111046
23 January 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 720012
25 December 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 129840
12 January 1994
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 657174
17 December 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1731
25 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165280
6 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 78913
22 August 1992
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 166808
29 July 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 115064
2 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 133110
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 27 August 2025
Resolved
The master of each towing vessel shall maintain operative navigational equipment.
The computer system housing Rosepoint was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2025
Resolution: Witnessed operation of new computer and navigational equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2025
Resolved
Propulsion machinery, including shafting, must be maintained to ensure proper operation.
Starboard shaft seal was leaking excessively.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 28 August 2025
Resolution: Re-inspected starboard shaft. Observed no leaking around packing gland while shaft was stationary.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 August 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 28 August 2025
Resolution: All FCC documents were re-issued.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 August 2025
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised.
Excessive water was accumulated in the stern void and the cause could not be clearly identified or explained.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 28 August 2025
Resolution: Stern void was pumped out. Verified no water ingressed overnight.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 17 November 2021
Resolved
Means must be provided for closing each ventilator serving machinery spaces in case of fire. Current engine room closure configuration does not allow for timely closing of engine room ventilation openings.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2021
Resolved 17 November 2021
Resolution: Modified ventilation closures to allow for timely operation in the event of a fire.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 25 April 2020
Resolved
No person may operate any vessel equipped with installed toilet unless it is equipped with an operable type II device. Ensure Vessels installed type II sewage system is operating within the standards of 33CFR159.53(b). Provide 3rd party report to attending Marine Inspector NLT 08MAY20.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2020
Resolved 19 May 2020
Resolution: received report from Sea2River.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 25 April 2020
Resolved
Vessel was found dumping untreated sewage overboard By bypassing the type II sewage tank while operating inland. On the spot corrections were made.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 25 April 2020
Engineering › Steering Gear System › Rudder
Issued 24 March 2014
Resolved
Port rudder damaged by impact with log or stump. Rudder will need to be removed and repaired.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2014
Resolution: Repairs completed by Conrad Aluminum and oversight from the owner Triple S Marine. All items as per work list were completed and tested. Rudders and tiller were repaired, all sat test. Bushings and shoes were replaced, all sat