SIREN

SIREN is a 1983 tank ship. The Coast Guard has recorded 43 inspections since 1991, most recently in March 2003, along with 42 deficiencies and 4 operational controls.

Records from 1991 to 2003. Most recent: inspection, 13 March 2003.

Built
1983
Last inspected
13 March 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7925792 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
365147
Flag
CYPRUS
—
Maury page id
psix-365147

Inspections, by type

…with no type recorded37
Years with a record 11 calendar years (1991–2003)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it18022 - Regulatory (Subpart C or D), Gross Ton
13142 - Regulatory (Subpart C or D), Net Ton
29990 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CO Towing Vessel · MISLE 68289 · 31 January 1995 · activity 148499PELHAM Towing Vessel · MISLE 77234 · 31 January 1995 · activity 148499THOMAS D. WITTE Towing Vessel · MISLE 79803 · 31 January 1995 · activity 148499

Inspection history · 43

13 March 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1756749
5 March 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1755853
14 February 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 287002
8 January 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 460255
25 September 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 283704
21 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 274874
11 December 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 423507
9 October 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 493391
19 June 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 45482
20 May 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 416226
1 May 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 450644
9 January 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 477308
10 September 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 407680
25 August 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 538975
22 April 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 402746
14 March 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 401424
26 December 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 441520
24 November 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 397762
4 April 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 389640
27 February 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 388211
21 January 1996 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 399642
5 September 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 688840
29 August 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 459701
3 August 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 688837
28 July 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 380957
1 February 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 445481
31 January 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 148499
14 November 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 688731
13 November 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1147560
9 November 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 372161
9 November 1994 MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1463859
26 October 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 688730
24 October 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 533485
24 October 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1175670
2 August 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 537537
3 February 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 364124
3 February 1994 Tank Vessel Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1162557
16 June 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 470930
25 August 1992 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1259804
21 August 1992 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 352841
21 August 1992 Certificate of Compliance · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1258473
23 July 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 344935
20 July 1991 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353174

Deficiency record · 42

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom Ventilation
Issued 5 March 2003 Resolved
missing pump room vent fan from heavy weather
Condition: Damaged By Earlier Event
Due 8 March 2003
Resolved 9 March 2003
Resolution: repairs conducted and attested to by class
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 5 March 2003 Resolved
3 mast risers found wasted and leaking, 1 found broke and inpropoerly reapired
Condition: Damaged By Earlier Event
Due 7 March 2003
Resolved 9 March 2003
Resolution: repairs attested to by class
Lifesaving › Inflatable Liferafts
Issued 5 March 2003 Resolved
portside rafts were missing due to heavy weather, rafts were recovered at sea by vessel
Condition: Damaged By Earlier Event
Due 7 March 2003
Resolved 10 March 2003
Resolution: rafts replaced, and attested to by class
Accommodation/Occupational Safety › Potable Water System
Issued 5 March 2003 Resolved
no running water in few crew cabins and hospital space
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Engineering › Steering Gear System
Issued 5 March 2003 Resolved
steering gear loss of control alarms inop
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Piping
Issued 5 March 2003 Resolved
wasted piping found in E/R
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Deck/Cargo › Inert Gas System
Issued 5 March 2003 Resolved
igs system would could noyt create IG at 5% or less
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: corrected and attested to by class
Deck/Cargo › Inert Gas System
Issued 5 March 2003 Resolved
provide certified span gas for calibrating igs system
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: corrected and attested to by class
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 5 March 2003 Resolved
220 volt ground found on switchboard
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 March 2003 Resolved
all fire doors were blocked from closing, and would not close porperly
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 5 March 2003 Resolved
seal holed A class bulkheads in stairway form cable runs
Condition: Improper Installation
Due 7 March 2003
Resolved 1 February 2010
Resolution: Vsl no longer in service.......
Electrical › Electric Supply System (service) › Cable
Issued 5 March 2003 Resolved
make appropriate repairs to pump room exhaust fan to pump room exhaust fan wiring.
Condition: Placed in Improper Service
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 5 March 2003 Resolved
holed deck water seal
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 5 March 2003 Resolved
port and stbd had inproper patches on wasted areas in containment, and was leaking
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: temp repaired and attested to by class
Fire Fighting › Fire Main
Issued 5 March 2003 Resolved
fire main was found frozen, and non operable
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 9 March 2003
Resolution: repaired and attested to by class
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 5 March 2003 Resolved
vessel failed to issue required 96 hour advanced notice of arrival, as required by 33CFR 160.208
Condition: Unknown
Due 6 March 2003
Resolved 7 March 2003
Resolution: processed a civil penalty against the vessel for the failure to provide an appropriate ANOA.
Deck/Cargo › Holds/Tanks › Ullage
Issued 5 March 2003 Resolved
4 cargo tank ullage openings were found open, and unattended. vessel personnel were un aware the ullage openings were open, and do not know how long the ullage's were left open and unattended
Due 7 March 2003
Resolved 7 March 2003
Resolution: ullages were immediately closed, and a civil penalty was processed against the vessel for failure to man an open cargo tank ullage opening.
Lifesaving
Issued 14 February 2001 Resolved
PRIOR TO DEPARTING THE PORT OF BOSTON, CONDUCT SATISFACTORY LIFEBOAT DRILL TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 December 2001
Resolved 15 February 2001
Lifesaving
Issued 14 February 2001 Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD LIFEBOAT DAVITS, READY FOR IMMEDIATE USE.
Condition: Unknown
Due 14 February 2001
Resolved 15 February 2001
Deck/Cargo
Issued 21 February 2000 Resolved
PROVE PROPER OPERATION OF CARGO TANK OVERFILL ALARMS IAW 33CFR 155.480_x001C_ PRIOR TO LOADING ANY OIL CARGOES IN US WATERS.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Deck/Cargo
Issued 21 February 2000 Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY PATCHES FOR COOLING SYSTEM ON IGS SCRUBBER TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Deck/Cargo
Issued 21 February 2000 Resolved
STORE AND LABEL EMERGENCY LIGHTERING EQUIPMENT IAW 33CFR 157.410
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Deck/Cargo
Issued 21 February 2000 Resolved
PROVE PROPER OPERATION OF CARGO PUMPROOM GAS DETECTOR PANEL.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Deck/Cargo
Issued 21 February 2000 Resolved
PROVIDE IGS ACCEPTANCE LETTER FROM CLASS.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Navigation
Issued 21 February 2000 Resolved
PROVIDE LOCKING NUTS OR PINS TO STEERING REPEATER LINKAGES.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Navigation
Issued 21 February 2000 Resolved
PROVE PROPER OPERATION OF AUDIBLE STEERING ALARMS ON BRIDGE IAW SOLAS 74 (A) II-1/29.8.4
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Deck/Cargo
Issued 11 December 1998 Resolved
Oxygen Analyzer records oxygen level at the source but does not set off thealarm or or redirect the flue gas if the oxygen level exceeds 5%. Repair before returning to a U.S. port.
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Navigation
Issued 11 December 1998 Resolved
Depth sounder recorder inoperable.
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Lifesaving
Issued 14 March 1997 Resolved
rudder support bar corroded from connection to portside lifeboat. Temporary repairs accepted. Make permanent repairs prior to return to U.S. waters or NLT 14APR97.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Deck/Cargo
Issued 27 February 1996 Resolved
CARGO TANKS WERE NOT INERTED WHEN VSL ENTERED PORT, REQUIRED VSL TO INERT TANKS TO BELOW 8% O2 PRIOR TO TRANSFERING CARGO. (SOLAS 74, REG. II-2/62.1)
Condition: Unknown
Due 27 February 1996
Resolved 29 February 1996
Fire Fighting
Issued 27 February 1996 Resolved
REQUIRED VSL TO REPLACE FIREMAN'S SUIT LIFELINE WITH ONE MADE OF A NON- FLAMMABLE MATERIAL. (SOLAS II-2 REG. 17/2)
Condition: Unknown
Due 28 February 1996
Resolved 29 February 1996
Documentation
Issued 28 July 1995 Resolved
THE VESSEL RESPONSE PLAN WAS INVALID.
Condition: Unknown
Due 28 July 1995
Resolved 31 July 1995
Engineering
Issued 9 November 1994 Resolved
MAIN ENGINE LUBE OIL COOLER LEAKING LUBE OIL._x001C_ _x001C_ REPAIR LUBE OIL COOLER.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Accommodation/Occupational Safety
Issued 9 November 1994 Resolved
FLOOR GRATINGS IN FORWARD PUMP ROOM WASTED AWAY._x001C_ _x001C_ RENEW WASTED FLOOR GRATINGS
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Construction/Loadline
Issued 9 November 1994 Resolved
BILGE SUCTION REMOTES DISCONECTED FOR BILGE MANIFOLD IN FORWARD PUMP ROOM_x001C_ _x001C_ REPAIR AND REATTACH REMOTES_x001C_
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Construction/Loadline
Issued 9 November 1994 Resolved
HULL MARKINGS AND LOADLINES NOT PAINTED IN CONTRASTING COLORS_x001C_ _x001C_ PAINT MARKINGS AND LOADLINES IN CONTRASTING COLORS
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Deck/Cargo
Issued 9 November 1994 Resolved
PORT AND STARBOARD CARGO OIL CONTAINMENT DRAINS WERE FOUND LEAKING._x001C_ _x001C_ CROP OUT AND RENEW AFFECTED PIPING_x001C_ _x001C_
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Construction/Loadline
Issued 9 November 1994 Resolved
CONCRETE PATCH ON SEWAGE OVERBOARD PIPE INBOARD OF SKIN VALVE._x001C_ _x001C_ RENEW PIPING IN AFFECTED AREA.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Construction/Loadline
Issued 9 November 1994 Resolved
FORECASTLE DECK WASTED THRU AT STEAM PIPING TO BOTH ANCHOR WINDLASSES_x001C_ CEMENT PATCHED AFFECTED AREA TO MAKE WATERTIGHT._x001C_
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Engineering
Issued 9 November 1994 Resolved
FUEL OIL SERVICE TANK FLAME SCREEN HOLED_x001C_ _x001C_ RENEW FLAME SCREENS _x001C_ _x001C_
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Deck/Cargo
Issued 20 July 1991 Resolved
RENEW FLAME SCREENS IN PV VALVES FOR CARGO TANKS: #1P/C, #2C, #3C, #4P/C,_x001C_ #5P, #6P, AND #7P/C PRIOR TO CARGO DISCHARGE.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Fire Fighting
Issued 20 July 1991 Resolved
RENEW RUBBER GASKETS ON ALL OUTSIDE FIRE STATION VALVE TO HOSE CONNECTIONS BY 20AUG91.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.