Records from 1991 to 2025. Most recent: inspection, 1 July 2025.
Inspection history · 29
1 July 2025
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8157559
28 May 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8146448
13 August 2024
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7980106
8 February 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7862631
13 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790997
11 September 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7791304
21 November 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601097
15 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7619489
25 October 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7583726
31 August 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7301404
2 June 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7213680
5 October 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7114724
9 July 2020
Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7002096
7 November 2013
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4751253
2 November 2010
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3883891
1 October 2010
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3861157
12 February 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3416514
8 January 2009
Administration
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3391181
18 June 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2968831
8 June 2006
Uninspected Other
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2673708
26 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2634222
6 February 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1484363
9 January 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 176638
8 June 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1716494
12 January 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 101191
24 October 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 173372
20 September 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 114080
31 January 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 148499
21 August 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 224437
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2025
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217. Vessel missing smoke detectors in the galley and 01 berthing space.
46 CFR 143.330 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 7 July 2025
Resolution: Received objective evidence of new smoke detectors installed.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 July 2025
Resolved
Each towing vessel 79 feet or more in length operating on oceans and coastwise routes that does not have an installed fixed fire-extinguishing system must have the following: (a) At least two firefighter's outfits that meet NFPA 1971; and (b) Two self-contained breathing apparatus of the pressure demand, open circuit type, approved by the National Institute for Occupational Safety and Health (NIOSH), under 42 CFR part 84. The breathing apparatus must have a minimum 30-minute air supply and full facepiece. Fire-fighting ensembles have not been serviced or inspected. The equipment listed above must be provided in a serviceable condition on the vessel prior to operating on a coastwise route.
46 CFR 142.226
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 July 2025
Resolution: Received email with objective evidence of servicing of [name withheld] fire suits.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2025
Resolved
The fire main must have a sufficient number of fire hydrants with attached hose to allow a stream of water to reach any part of the machinery space using a single length of fire hose. 01 fire hose has damaged threads, preventing a nozzle from being attached.
46 CFR 142.325 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 7 July 2025
Resolution: Received objective evidence of additional fire hose installed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 July 2025
Resolved
Carriage requirement. A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 for specified areas where the vessel operates. Vessel has insufficient number of flares (6 day and 6 night) as required for a Coastwise and Limited Coastwise route > 3 miles from shore. Vessel's route is restricted to Coastwise = 3 miles from shore until required amount of flares is provided.
46 CFR 141.375 (a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 July 2025
Resolution: Received objective evidence of appropriate amount and type of flares onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2025
Resolved
Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104. Vessel's STBD running navigation light is inoperable.
46 CFR 143.415 (a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 1 July 2025
Resolution: Bulb was renewed during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 1 July 2025
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. 02 Steering pumps in the E/R on the vessel's STBD side missing covers or guards around exposed rotating components.
46 CFR 144.820
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 7 July 2025
Resolution: Received objective evidence of guards installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2025
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Vessel is missing required Four Day shapes (3 balls, 1 diamond).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 7 July 2025
Resolution: Received objective evidence of appropiate day shape onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2025
Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. Vessel is missing means to take blood pressure readings. Vessel is restricted to Limited Coastwise route until providing the required equipment.
46 CFR 140.425
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 July 2025
Resolution: Received objective evidence of new blood pressue cuff onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 1 July 2025
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Vessel has 1 line throwing appliance on board, but is missing a total of: 4 rocket projectiles, 4 primer-ejector cartridges, and 4 service lines in accordance with 46 CFR 160.040-4. Vessel is restricted to a limited coastwise route until providing required equipment listed above.
46 CFR 141.385
46 CFR 160.040
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 July 2025
Resolution: Received objective evidence of 03 new line throwing appliances onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 September 2024
Resolved
A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a dryock and internal structural examination at least twice every five years, with not more than 36 months between examinations. Vessel is overdue as of 01SEP2024 for a drydock and internal examination. Drydock and internal examination must be completed to the satisfaction of USCG prior to conducting operations.
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Vessel completed DD/ISE.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 September 2023
Resolved
"The owner or managing operator must implement
procedures to identify and mitigate health and safety
hazards, including but not limited to:(8) Noise;(14)
Potable water supply." Health and Safety plan did not
contain procedures to identify and mitigate hazards
associated with noise and potable water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 5 October 2023
Resolution: health and safety plan updated to include missing sections
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 13 September 2023
Resolved
Each towing vessel must have a reliable means to
provide notification when an emergency condition exists
or an essential system develops problems that require
attention. The following alarms must be provided: (1)
Main engine low lubricating oil pressure; (2) Main
engine high cooling water temperature; (3) Auxiliary
generator engine low lubricating oil pressure; (4)
Auxiliary generator engine high cooling water
temperature." No engines were able to alarm for high
jacket water or low lube oil.
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Observed installed engine alarms and operationally tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2023
Resolved
"Pressure vessels over 5 cubic feet in volume and over
15 pounds per square inch maximum allowable working
pressure (MAWP) must be equipped with an indicating
pressure gauge (in a readily visible location) and withone or more spring-loaded relief valves. The total
relieving capacity of such relief valves must prevent
pressure from exceeding the MAWP, as established by the
manufacturer, by more than 10 percent." Pressure relief
valve on all air compressor tanks matched the tanks'
MAWP of 150 PSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 5 October 2023
Resolution: pressure relief valve has been changed out to have a set point of 130 PSI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 September 2023
Resolved
Each watertight door and watertight hatch must be marked
on both sides in clearly legible letters at least 25
millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED”
or “WATERTIGHT HATCH—KEEP CLOSED”. No watertight doors
on board were labeled accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 5 October 2023
Resolution: WATERTIGHT DOOR HAVE BEEN MARKED ACCORDINGLY
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 June 2021
Resolved
(b) Each towing vessel must carry on board and maintain the following:
(1) Charts or maps. Marine charts or maps of the areas to be transited, published by the National Ocean Service (NOS), the ACOE, or a river authority that satisfy the following requirements:
(ii) The charts or maps must be either—
(A) Current editions or currently corrected editions, if the vessel engages in towing exclusively on navigable waters of the U.S., including Western Rivers;
Found backup charts and AIS without a valid log of current updates. Master was unfamiliar with process of updating charts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2021
Resolved 14 June 2021
Resolution: Vessel resolved deficiencies. Company made updates to company policy and communicated to all vessels the requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 2 June 2021
Resolved
(a) The safety of the towing vessel is the responsibility of the master and includes:
(2) Compliance with the applicable provisions of this subchapter;
The master could not provide means of verifying ship's length in AIS. Master lacked familiarty with vessel health and safety plan.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2021
Resolved 14 June 2021
Resolution: Vessel resolved deficiencies. Company made updates to company policy and communicated to all vessels the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2021
Resolved
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
The 110V ground detection panel indicated ground. Flame shields were not installed on the stbd engine fuel filters. Air receivers were not labeled with MALP. 110V outlet in generator room had electrical extension cord ziptied to the receptacle. Vessel had unauthorized box fan installed above ship's range in the galley.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2021
Resolved 14 June 2021
Resolution: Vessel installed new bulbs in 110V ground detection panel which fixed the grounded light; purchased and installed flame shields for fuel filters; stenciled the max allowable working pressure on air receivers; removed zip ties and uninstalled box fan.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 2 June 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either:
(1) Automatic, battery-operated with a duration of no less than 2 hours; or
(2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
Crew accomodations did not have emergency lighting or emergency phosphorescent adhesive lighting strips installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2021
Resolved 14 June 2021
Resolution: Operator installed phosphorescent adhesive lighting strips to satisfy requirement.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 September 2020
Resolved
The fire main system must be charged, and sufficient pressure must be verified at the most remote and highest outlets.
Fire main piping was found to be leaking when either fire pump was operational. provide repair plan and complete repair prior to movement of vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 September 2020
Resolved 8 September 2020
Resolution: cropped and renewed degraded piping on firemain. verified by MIs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2020
Resolved
Portable and semi-portable fire extinguishers must be inspected.
Annual inspection of fire extinguishers lapsed in July 2020.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 September 2020
Resolved 8 September 2020
Resolution: Verified extinguishers were serviced, tech report provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 July 2020
Resolved
Each EPIRB and each SART, other than an EPIRB or SART in an inflatable liferaft, must be tested monthly. The EPIRB must be tested using the integrated test circuit and output indicator to determine that it is operative.
Vessel currently does not have a maintenance system for EPIRB monthly checks. Develop plan to record monthly maintenance within 14 days to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2020
Resolved 29 September 2020
Resolution: Vessel owner created maintenance log and is being utilized onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2020
Resolved
Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104 (incorporated by reference, see §136.112 of this subchapter) or other standards accepted by the Coast Guard.
Vessels aft amber towing lights did not meet UL 1104 requirement. Rectify deficiency within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Aft amber towing lights were replaced to meet UL requirements.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 July 2020
Resolved
Each towing vessel equipped with rudder(s) must have a means to monitor and control the position of the rudder(s) at each operating station.
Vessel rudder angle indicator on STBD side of console is not operating. Rectify deficiency within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 2 December 2020
Resolution: MI verified rudder angle indicator installed and working.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2020
Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station.
Vessel was missing extra lifejacket at pilot house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2020
Resolved 8 September 2020
Resolution: MIs verified additional life jacket on board.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 July 2020
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation:Illuminated magnetic compass. The compass must be readable from each operating station.
Compass light is inoperable. Rectify deficiency within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Magnetic compass light was replaced, verified operation. All sat.
Construction/Loadline › Structures › Scuttle
Issued 8 June 2006
Resolved
Repair or renew wasted knife edge (coaming) on aft peak hatch.
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 22 June 2006
Resolution: Examined repair and witnessed hose test of hatch coaming. All sat.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 8 June 2006
Resolved
Replace PVC piping on keel coolers with schedule 80 steel piping, or equivalent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 27 June 2006
Resolution: Examined new schedule 80 steel piping installed in port/stbd keel coolers.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 June 2006
Resolved
Install flame screens on all sewage and oil tank vents.
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 22 June 2006
Resolution: Examined new flame screens. All sat.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Number
Issued 8 June 2006
Resolved
Provide semi-portable or fixed carbon dioxide fire extinguishing system for engine room.
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 27 June 2006
Resolution: Vessel appeal of requirement approved. Cleared.