MAURY USCG vessel records
← All vessels

B NO 285

B NO 285 is a 1987 tank barge. The Coast Guard has recorded 142 inspections since 1987, most recently in April 2021, along with 143 deficiencies — 8 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2007 and 2014.

Records from 1987 to 2021. Most recent: inspection, 21 April 2021.

Built
1987
Last inspected
21 April 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 21 April 2021
…with no type recorded56
…past their stated due date4
Operational controls 1 with no removal date recorded
Years with a record 33 calendar years (1987–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WZE5039
289398
Flag
UNITED STATES
Maury page id
psix-289398

Documentation record

Tonnage as PSIX records it9832 - Regulatory (Subpart C or D), Gross Ton
11852 - Convention (Subpart B), Gross Ton
9832 - Regulatory (Subpart C or D), Net Ton
5692 - Convention (Subpart B), Net Ton
19995 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

142 inspections, each with its date, unit and type; 143 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; 8 vessels inspected with it, by name and date; 2 casualty investigations, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 142

21 April 2021 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7188325
8 October 2020 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7073812
30 May 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6717851
20 March 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6645840
25 April 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6399416
18 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6310423
17 November 2017 Deficiency Check · Re-Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6308970
12 September 2017 Plan Review (Other than "T") · Permit to Proceed · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6265396
7 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6270417
6 September 2017 MTSA Verification · Permit to Proceed · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6261254
29 September 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6012410
30 June 2016 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5922237
23 May 2016 COI Inspection · Deficiency Check · Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5884051
3 March 2016 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5823937
19 November 2014 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5026284
15 September 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4985461
16 February 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4801691
10 January 2014 Deficiency Check · Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4780395
4 October 2013 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4729189
1 October 2013 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4726629
26 September 2013 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4723239
10 September 2013 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4711240
9 September 2013 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4711333
14 June 2013 Construction Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4622515
14 November 2011 Internal Structural Exam · Cargo Tank Internal · COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4191469
12 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3868501
25 January 2010 MARPOL Annex V Examination · MARPOL Annex I Examination · Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3665965
3 March 2009 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3427060
22 January 2009 MARPOL Annex I Examination · MTSA Verification · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3398388
25 February 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3153292
15 January 2008 MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3130581
28 September 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3068389
18 June 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2968831
1 May 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2920045
22 December 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2845002
27 October 2006 Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2820079
11 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743974
1 August 2006 MTSA Verification · Construction Oversight · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2732999
3 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578837
11 March 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2308331
13 February 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2291606
6 January 2005 Annual Inspection · MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2269133
27 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2079853
14 January 2004 Re-Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1983888
11 January 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1981415
9 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962288
20 November 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1951770
23 October 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1934601
22 October 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1933849
6 August 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1929043
27 March 2003 In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1764226
26 March 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1763762
5 February 2003 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1740191
17 December 2002 Hull Examination · MARPOL Annex V Examination · Internal Structural Exam · Annual Inspection · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1719896
1 December 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1713002
19 November 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1707574
31 October 2002 In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1698824
31 October 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1700551
12 October 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1693626
4 October 2002 In-Service Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1687232
18 July 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1648446
16 July 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1648409
21 April 2002 Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1607271
17 March 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494305
16 March 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495716
28 February 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1490214
4 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1477479
10 October 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1453949
8 March 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1458841
7 February 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 24255
9 January 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427951
7 December 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 134849
24 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275168
20 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811811
6 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 813316
16 October 1999 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378836
8 October 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 785790
20 May 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 104789
8 January 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811430
4 January 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807601
15 December 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465443
30 January 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1456560
29 January 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1107674
15 January 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 666842
3 November 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 409575
22 October 1997 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1114034
19 October 1997 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372015
30 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 473939
24 January 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106803
18 December 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1442493
1 February 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1181209
5 January 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871788
3 December 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 491665
25 October 1995 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 876521
10 January 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1170037
9 December 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467886
13 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 440117
25 January 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 852233
29 October 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 833065
13 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 533235
10 January 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 486726
28 December 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 831063
27 December 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2977
16 December 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826091
13 July 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 520248
9 April 1992 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 949346
8 April 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 349967
15 March 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 488299
11 March 1992 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1391753
2 March 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 666790
1 March 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 133231
27 February 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 517684
24 February 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 537138
24 February 1992 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1260704
10 January 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 477090
11 December 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1258186
17 October 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250621
31 January 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903704
10 January 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932015
8 January 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1240639
12 December 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906397
2 October 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 524500
30 May 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 499555
30 March 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911209
30 March 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1247816
15 March 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911085
12 February 1990 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 436794
24 January 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907248
20 December 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226927
14 December 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233666
27 June 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 472182
21 April 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1194103
21 November 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 326948
15 November 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 444636
29 September 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194375
22 August 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1345896
15 August 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 515325
26 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891323
26 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023822
22 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023496
17 February 1988 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 524226
18 December 1987 Construction Oversight · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011686

Deficiency record · 143

Construction/Loadline › Structures › Deck Plating
Issued 25 April 2018 No resolution recorded
The Administration shall satisfy itself that the general strength of the hull is sufficient for the draught corresponding to the freeboard assigned. Vessel has severe wastage on deck throughout the entire length of vessel as evidenced by a hole on bow, severe pitting, and visual wastage calling into question the longitudinal girder strength and structural integrity. Starboard bow void has evidence of water intrusion causing severe scaling and wastage. Have load line assigning authority certify vessel is in compliance with load line conventions. ICLL Reg 1 / 46 CFR 42.07-45
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Transverse Frame
Issued 25 April 2018 No resolution recorded
Starboard bow void has severe scaling and wastage throughout, specifically on cargo tank bulkhead. Remove corrosion and scaling in order to conduct UT shots in a 1' by 1' grid on entire cargo tank bulkhead in starboard void. Demonstrate compliance with classification society rules or 46 CFR 32.59-1 (b). ICLL Reg. 1 & 46 CFR 32.59-1 (b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 25 April 2018 No resolution recorded
Cargo tank venting is to be carried out in accordance with 46 CFR 32.55-25. Several cargo tank reach rod stand pipes, cargo trunk tops, hatch combings, etc were wasted beyond ability to ensure vapor tightness as evidenced by the failed vapor tightness test and Marine Inspector visual observations. Remove corrosion and de-scale rust in order to conduct vapor tightness test in presence of a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Vessel Activity › Construction/Repair
Issued 25 April 2018 No resolution recorded
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. Conduct an additional external verification to evaluate the adequacy of the company's maintenance procedures specifically related to cargo systems, materiel conditions of the main deck and associated fittings.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 17 November 2017 Resolved
All paint lockers must be protected by a CO2, water spray, or clean agent fire extinguishing system. Aft peak port space contained several cans of paint and other flammable items that need to be removed.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 February 2018
Resolved 27 April 2018
Resolution: All combustible and flammable materials were removed.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 17 November 2017 Resolved
Tank barges shall be provided with a combustible gas indicator suitable for determining the prescence of explosive concentrations of the cargo carried. Provide proof onboard gas meter capable of detecting explosive concentrations within void spaces.
Condition: Invalid
Due 16 February 2018
Resolved 11 April 2018
Resolution: Tankerman had 40ft hose with instructions on how to hook up to portable gas meter and take samples from void spaces.
Electrical › Lighting (service) › Switch
Issued 17 November 2017 Resolved
110v electrical cables and light switches in bow center and stbd voids show evidence of chaffing and are not mounted properly. Prior to usage, lockout/tag out until repairs are made to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 16 February 2018
Resolved 27 April 2018
Resolution: Cable was re-routed above cargo deck.
Electrical › Electric Generation Source (service) › Conductor
Issued 17 November 2017 Resolved
Numerous instances of chaffing electrical cables along cargo tank top areas as previously identified in ABS survey dated 18sep17. Make appropriate repairs.
Condition: Invalid
Due 16 February 2018
Resolved 11 April 2018
Resolution: All conduit on cargo tank top had chaffing gear replaced.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 17 November 2017 No resolution recorded
Section 4.5 Part B of the Bouchard Safety Management Manual (2017 edition) prescribes the safe working practices for entry into restricted access spaces. The aft peak port space has been identified as a restricted access space and is regularly accessed for storage. There is no objective evidence to indicate that these safe work practices have been implemented prior to entry. Prior to entry, company is to provide documentation and implementation of safe working practice.
Due 16 February 2018 — due date passed with no resolution recorded
Deck/Cargo › Cargo Condition › Bulk Liquid
Issued 17 November 2017 Resolved
Provide marine chemist report for all voids and ballast tanks to include aft peak port space to [email withheld] prior to discharging cargo.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2017
Resolution: Recieved Marine chemist certificate (Lucas Kuebler #728) form Vessel rep [name withheld] with satisfactory readings on all tanks tested.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 17 November 2017 Resolved
The #2 generator and #3 & 4 cargo pump engines have notable lube oil leaks at the cylinder head in way of the exhaust manifolds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 11 April 2018
Resolution: Gaskets replaced, no remaining leaks
Engineering › Diesel Engine (auxiliary) › Governor
Issued 17 November 2017 Resolved
The #3 & 4 cargo pump engine tachometers are inoperable.
Condition: Improper/Lack of Maintenance
Due 16 February 2018
Resolved 11 April 2018
Resolution: Tachometers were replaced and witnessed operational
Deck/Cargo › Cargo Stowage › General
Issued 17 November 2017 Resolved
Provide marine chemist report for aft port peak tank, port, center, and stbd bow void spaces for Coast Guard attendance in order to clear associated 835's.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 27 April 2018
Resolution: Marine chemist cert was provided.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 17 November 2017 No resolution recorded
Hydraulic engine tachometer inoperable. Replace with operable tachometer
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 November 2017 No resolution recorded
Each vessel that carries flammable cargo must meet the requirements of 46 CFR 111.105, i.e. intrinsically safe electrical installations. (i) An enclosed space that is immediately above, below, or next to a cargo tank must not contain any electric equipment except equipment allowed for cargo handling rooms in paragraphs (f) and (g), and: (1) Through runs of marine shipboard cable; and (2) Watertight enclosures bolted and gasketed covers containing only: (i) Depth Sounding devices; (ii) Log devices; and (iii) Impressed-current cathodic protection system electrodes. Marine Inspectors found a capstan controller that is not intrinsically safe nor explosion proof and is not in compliance with 111.105. Also found, was a cathodic protection installation that appears to have moisture / water intrusion and does not meet 111.105-31 (i)(2). Provide an acceptable repair proposal to the Coast Guard prior to loading cargo in the forward most cargo tanks.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2018 — due date passed with no resolution recorded
Resolution: Vessel rep produced drawings that showed a cofferdam between #1 P & S cargo tank and fwd center void. MI's attended vsl and verfied onboard. Reopened on 03MAY18.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 17 November 2017 No resolution recorded
The following locations in the weather are Class 1, Division 1 locations and may have only approved intrinsically safe, explosion proof, or purged and pressurized electrical equipment... The motor assembly on the port side crane is outfitted with an explosion proof box and intrinsically safe fittings that have been compromised. Repair or replace as required.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2018 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 September 2017 Resolved
Cargo tank of a vessel connected to a vapor collection system must be of a closed type. Vaporrelief Piping cargo Pump #2 has leak pinhole size, #3 p Valve stem pipe has 1/4" Hole at base. Multiple areas leaking vapor to include: (1) 1P Valve Stem (2) Ullage Port FR 36-6-78 p (3) 2P Valve Stem (4) Deep Well reach rod aft of #1 Cargo Pump Room (5) 6 Stbd Ullage Access Gasket (6) 5 Stbd Ullage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2017
Resolution: All items on the 835 are completed in accordance with approved PTP Repair plan provided by vessel rep. Repairs were accepted and approved I.A.W. inspections conducted I.A.W. Repair Plan.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 17 June 2016 Resolved
Repair fuel leak on STBD Ballast Pump engine between valve and standpipe IAW 46 CFR 38.10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2016
Resolution: Ensured fuel leak was repaired.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 17 June 2016 Resolved
Ensure vapor control system permanent stud is in place IAW 46 CFR 39.20-1.
Due 24 June 2016
Resolved 30 June 2016
Resolution: Attended vessel and verified new stud has been installed on all vapor line piping
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 June 2016 Resolved
Replace tank hatch gasket on #5 and 6 port cargo tanks. Provide ABS cert IAW 46 CFR 38.10.
Due 17 July 2016
Resolved 30 June 2016
Resolution: Attended vessel and verified gaskets have been replaced and vapor tightness test has been conducted to prove proper seal.
Electrical › Electric Generation Source (service) › Generator
Issued 17 June 2016 Resolved
Replace generator day tank handles IAW 46 CFR 38.10.
Due 17 July 2016
Resolved 17 June 2016
Resolution: Replace door gasket in stbd ballast pump engine room IAW 46 CFR 38.10.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 14 June 2016 Resolved
#1 Cargo pump emergency shutdown handle was broken during operation. Handle must be replaced and prove proper operation prior to conducting IAW 46 CFR 32.50-35.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Retested cargo pump shutfown handle. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 3 March 2016 Resolved
The #1 Cargo Pump remote shutdown found inoperative. Prove proper operation prior to conducting cargo operations with the #1 Cargo Pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2016
Resolution: Received email correspondence from the USCG ([name withheld]) and the company confirming the def has been rectified.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 19 November 2014 Resolved
Cargo piping valve position (open/closed) indicators are in various states of disrepair throughout the cargo deck. Repair and return to original design specifications, allowing for valve position indication.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 30 June 2016
Resolution: Received email corrspondence from USCG and company confirming the def has been cleared.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 13 January 2014 Resolved
Vessel IAPP currently does not have the vessel in compliance with MARPOL Annex VI Reg 15. Vessel is required to have ABS update their IAPP to indicate compliance with Reg 15.
Due 13 February 2014
Resolved 14 February 2014
Resolution: Vessel provided copy of amended IAPP certificate issued by ABS on 30JAN2014 showing compliance with MARPOL Annex VI, Reg. 15.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 January 2014 Resolved
Where the cargo pump shaft pierce gas tight bulkheads, stuffing boxes with readily accessible gas tight glands shall be provided. 46cfr 32.50-1
Due 13 February 2014
Resolved 18 February 2014
Resolution: Received photo documentation showing new bellows installed on cargo pump shaft penetrations.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 26 September 2013 Resolved
Cargo leak suspected in the bow void. Vsl directed to offload cargo and provide written plan detailing repairs.
Action required: 705 - Other - as specified
Resolved 26 September 2013
Resolution: Cargo offloaded, PTP issued to transit to Tampa, FL for tank cleaning and repairs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 September 2013 Resolved
Vessel to make repairs to the fwd bulkhead of the #1 stbd cargo tank to the satisfaction of the attending class surveyor or Coat Guard Inspector within thirty days and prior to carrying cargo in the affected cargo tank.
Condition: Damaged By Earlier Event
Due 19 September 2013
Resolved 10 September 2013
Resolution: One (1) insert of 18 in X 18 was made on outboard side in lower area of transverse bulkhead in way of after transverse bulkhead in No. 1 Void tank. Repairs made to satisfaction of attending ABS surveyor
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 14 November 2011 Resolved
Provide proper operation of #1 Cargo Engine overspeed shutdown. Cite: 46 CFR 111.12(b)
Due 8 January 2012
Resolved 4 January 2012
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Location
Issued 6 January 2005 Resolved
BV extinguisher located foward, on the port side not secured properly.
Condition: Improper Installation
Due 6 February 2005
Resolved 28 January 2005
Resolution: Verified that extinguisher has been permanently attached to deck via phone conversation with Ed Christie, POC for Bouchard Transportation. [name withheld] followed up by sending e-mail with digital photos as proof of repair completed dated 17JAN05.
Deck/Cargo › Cargo Heating › General
Issued 6 January 2005 Resolved
Documentation of visual inspection of thermal fluid heater was not available. Must be provided.
Due 6 February 2005
Resolved 11 January 2005
Resolution: Received e-mail verification from [name withheld] of ACTNY that TFH was opened for visual inspection in January 2003.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 14 January 2004 Resolved
LIFELINE STANTION AMIDSHIP FORWARD IS MISSING LEGACY COMPONENT DESC: Lifeline
Condition: Unknown
Due 31 March 2006
Resolved 31 October 2006
Deck/Cargo › Cargo Heating › General
Issued 14 January 2004 Resolved
Gauges on Thermal Fluid Heater cracked LEGACY COMPONENT DESC: Gauges
Condition: Unknown
Due 1 February 2004
Resolved 6 January 2005
Resolution: Guage has been replaced and is operational.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 14 January 2004 Resolved
Air filter breather filter cover on port fwd pump engine loose
Condition: Placed in Improper Service
Due 21 January 2004
Resolved 14 January 2004
Resolution: Filter cover replaced
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 14 January 2004 Resolved
Emergency shutdown on the number 1 cargo pump inoperable LEGACY COMPONENT DESC: Emergency shutdown
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2004
Resolution: Cable repaired
Accommodation/Occupational Safety › Occupational Safety
Issued 14 January 2004 Resolved
Fumes in aft rake from paint cans LEGACY COMPONENT DESC: Aft rake
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2016
Resolution: Paint cans stowed, fumes eliminated
Accommodation/Occupational Safety › Occupational Safety
Issued 14 January 2004 Resolved
Properly stow all rags LEGACY COMPONENT DESC: Receptacle Outlet
Condition: Unknown
Due 21 January 2004
Resolved 21 January 2004
Resolution: Rags placed in proper storage bins.
Deck/Cargo › Holds/Tanks
Issued 14 January 2004 Resolved
Repair hole in forward paint locker LEGACY COMPONENT DESC: Bulkhead
Condition: Unknown
Due 21 January 2004
Resolved 21 January 2004
Resolution: Hole patched using epoxy.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 January 2004 Resolved
Properly stow all loose items as discussed LEGACY COMPONENT DESC: loose gear
Condition: Improper/Lack of Maintenance
Due 21 January 2004
Resolved 21 January 2004
Resolution: All loose items properly stowed for sea.
Electrical › Lighting (service)
Issued 27 March 2003 Resolved
Install light fixture cover above generator switchboard and replace broken light fixture cover outboard of generator prior to 3 April 2003.
Condition: Unknown
Due 3 April 2003
Resolved 1 April 2003
Resolution: Installed new light fixture covers in space.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 1 February 2003 Resolved
Starboard port hole cover in berthing space broken. LEGACY COMPONENT DESC: Port hole cover
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 6 January 2005
Resolution: Port hole cover found to be replaced and in proper working order.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2003 Resolved
Starboard forward paint locker holed in bottom corner. LEGACY COMPONENT DESC: Paint locker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2004
Resolved 6 January 2005
Resolution: Hole in paint locker plugged/patched to allow fore air tightness.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2003 Resolved
Lighting inoperable in #1 Port Cargo pump house, Starboard aft cargo pump house, Thermal fluid heater space. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 6 January 2005
Resolution: Lighting in pump house inspected and found to be in good working order.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 February 2003 Resolved
Battery tie downs missing fastening bolts for all prime movers. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2003
Resolved 6 January 2005
Resolution: Battery tied downs and place, batteries are securely mounted.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 1 February 2003 Resolved
Space under cargo pump and generator prime movers contain antifreeze and oil. Clean as necessary to remove all resuidues. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2003
Resolved 6 January 2005
Resolution: Areas below pump and generator prime movers all found to be clean and oderly.
Electrical › Lighting (service)
Issued 1 February 2003 Resolved
Replace 3 light bulbs in generator space. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 1 February 2003 Resolved
Light above upper starboard rack missing light cover. Upper port rack light inoperable. LEGACY COMPONENT DESC: Berth lighting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 February 2003 Resolved
Common space (Office) light inop. LEGACY COMPONENT DESC: Accomodation (Office) light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 February 2003 Resolved
Forward railing (Bow) courses missing. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Electrical › Lighting (service)
Issued 1 February 2003 Resolved
Inoperable light on outside of aft cargo pump house. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 1 February 2003 Resolved
B-II Fire extinguisher in TFH space missing bracket and laying on deck. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Electrical › Electric Supply System (service) › Cable
Issued 1 February 2003 Resolved
Battery cables for all prime movers loose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 February 2003 Resolved
Vents in overhead for barge in house were frozen due to lack of maintenance. A torch had to be employed to return control of vents. LEGACY COMPONENT DESC: Recreation Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Navigation › Collision/Grounding Avoidance
Issued 1 February 2003 Resolved
Forward (Stern light) used when vessel is in a "stern fwd" tow was inop. Vessel rep. stated that it isn't used. Repair or remove light as required. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Accommodation/Occupational Safety › Ventilation › General
Issued 31 January 2003 Resolved
Fan blade missing from thermal fluid heater space vent motor. LEGACY COMPONENT DESC: Thermal Fluid heater space
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 6 January 2005
Resolution: Ventalation fan varified to have all three blades and to be running correctly.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 31 January 2003 Resolved
Replace the missing cable on the stbd cargo boom. Inboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2003
Resolution: Corrected to the satisfaction of attending MI.
Documentation › Manuals/Policy Documentation
Issued 31 January 2003 Resolved
Provide plan for newly installed mooring winch. Plans are to be approved by U.S.C.G. plan review before use of the winch. LEGACY COMPONENT DESC: Installation plans
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Received and reviewed plans for winch installation. Plans marked examined and plan review letter PR-030006 sent to owners.
Pollution Prevention/Response › Prevention Equipment
Issued 17 December 2002 Resolved
Starboard cargo containment filled with ice resulting in an inadeqaute capacity. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Electrical › Electric Generation Source (service)
Issued 17 December 2002 Resolved
Vessel's 100+kW genset could not be tripped during an overspeed test. Electrician was required to recalibrate device. LEGACY COMPONENT DESC: Overspeed trip
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 1 February 2003
Resolution: Corrected on scene.
Engineering › Compressed Air System (control)
Issued 19 November 2002 Resolved
Provide air receiver for internal inspection or hydrostatic test to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 31 January 2003
Resolution: Corrected.
Deck/Cargo › Cargo Stowage
Issued 19 November 2002 Resolved
Repair and or replace missing bolts on numerous P/V's flame vent screen covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 31 January 2003
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 19 November 2002 Resolved
Provide proper electrical wire support for exterior lighting cables on accommodation and generator deck houses. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 31 January 2003
Resolution: Corrected
Electrical › Electric Generation Source (service)
Issued 31 October 2002 Resolved
Show proper operation of 120vac ground detection lights. LEGACY COMPONENT DESC: Ground Detection
Due 20 November 2002
Resolved 19 November 2002
Electrical › Electric Generation Source (service)
Issued 31 October 2002 Resolved
Provide generator start cables, from battery to starter with adaquate support at 24" intervals to keep cabel out of oily catch basin. LEGACY COMPONENT DESC: Generator
Due 20 November 2002
Resolved 19 November 2002
Deck/Cargo › Cargo Stowage
Issued 31 October 2002 Resolved
Clean or replace the following 6" flame screens; P-2, S-1, S-7. LEGACY COMPONENT DESC: flame screens
Due 20 November 2002
Resolved 19 November 2002
Construction/Loadline › Penetrations
Issued 31 October 2002 Resolved
Provide adaquate packing for cargo transfer deck valve at P-2. LEGACY COMPONENT DESC: Gasket
Due 20 November 2002
Resolved 19 November 2002
Operations/Management › Pollution
Issued 31 October 2002 Resolved
Provide a means to accommandate oily waste mixtures (Open five gallon buckets of oily waste) such that it will not pose a hazard of pollution or a safety hazard to the vessel or crew members working on board. LEGACY COMPONENT DESC: Retention of Oily Mixture
Due 20 November 2002
Resolved 19 November 2002
Electrical
Issued 9 January 2001 Resolved
Prior to departure prove satisfactory operation of overspeed trip on outboard generator.
Condition: Unknown
Due 10 January 2001
Resolved 26 January 2001
Fire Fighting
Issued 9 January 2001 Resolved
Prior to vessel departure, provide proper test gas for explosive meter andcalibrate meter.
Condition: Unknown
Due 10 January 2001
Resolved 26 January 2001
Lifesaving
Issued 9 January 2001 Resolved
Prior to sailing, Prove proper operation of vessel's EPIRB.
Condition: Unknown
Due 10 January 2001
Resolved 26 January 2001
Lifesaving
Issued 9 January 2001 Resolved
Prior to vessel departure, provide appropriate lights for life jackets, and survival suites.
Condition: Unknown
Due 10 January 2001
Resolved 26 January 2001
Navigation
Issued 9 January 2001 Resolved
Repair aft flashing amber light.
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Engineering
Issued 6 December 1999 Resolved
REPAIR OR REPLACE, ON DECK FUEL LINES, FOR GENERATORS.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Accommodation/Occupational Safety
Issued 16 October 1999 Resolved
Replace or repair door to galley from center passageway NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Electrical
Issued 16 October 1999 Resolved
Repair port generator and conduct USCG tests on both generators in presenceof USCG Marine Inspector NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Fire Fighting
Issued 16 October 1999 Resolved
Number all fire ext. stations NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Documentation
Issued 16 October 1999 Resolved
Conduct IOPP Annual Survey with USCG Marine Inspector NLT 06FEB00.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Unknown
Issued 16 October 1999 Resolved
Provide ABS Surveyor report addressing watertight/weathertight doors, hatches, their coamings and gaskets to USCG MSO Miami NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Engineering
Issued 16 October 1999 Resolved
Replace main fuel tank vent ball NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Engineering
Issued 16 October 1999 Resolved
Replace flame screen and ball for Thermal Fluid tank vent NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Lifesaving
Issued 16 October 1999 Resolved
Provide instructions for donning lifejackets NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Lifesaving
Issued 16 October 1999 Resolved
Provide labels for lifejacket stowage NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Construction/Loadline
Issued 16 October 1999 Resolved
Repair vent hatch on FWD port pump house roof, NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Lifesaving
Issued 16 October 1999 Resolved
Replace the "Warning No Smoking" sign on the port side NLT 16NOV99.
Condition: Unknown
Due 16 October 1999
Resolved 16 October 1999
Deck/Cargo
Issued 8 October 1999 Resolved
CONNECTION BETWEEN CABLE AND ANCHOR CHAIN FAILED CAUSING ANCHOR TO BE PULLED FREE.
Condition: Unknown
Due 22 October 1999
Resolved 14 October 1999
Engineering
Issued 15 December 1998 Resolved
REPLACE/REPAIR STUDS IN THERMAL FLUID HEATER END HOUSING.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Deck/Cargo
Issued 15 December 1998 Resolved
REPAIR/REPLACE RISING STICK INDICATORS ON #2 STARBOARD & #3 PORT CARGO TANKS.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Deck/Cargo
Issued 22 October 1997 Resolved
MAKE PERMANENT REPAIRS TO APPROX 3" FRACTURE ON TRANSVERSE BLKHD SEPARATING#1 PORT CARGO TANK & FOREPEAK. FRACTURE WAS DRILL STOPPED & WELDED UP AS ATEMPORARY REPAIR. AT NEXT DRYDOCK OR CARGO TANK INTERNAL (WHICHEVER FIRST) THIS SECTION IS TO BE INSERTED. CREW TO PERIODICALLY EXAMINE TEMP REPAIR.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Deck/Cargo
Issued 19 October 1997 Resolved
MAKE THERMAL FLUID HEATER READY FOR INSPECTION AND CONDUCT ALL OPERATIONAL TESTS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Deck/Cargo
Issued 19 October 1997 Resolved
PRIOR TO DEPARTURE, REPLACE WASTED CONTAINMENT PLUGS.
Condition: Unknown
Due 19 October 1997
Resolved 27 October 1997
Lifesaving
Issued 19 October 1997 Resolved
PRIOR TO DEPARTURE, PROVIDE RETRO-REFLECTIVE TAPE FOR BOTH RING BUOYS.
Condition: Unknown
Due 19 October 1997
Resolved 27 October 1997
Electrical
Issued 19 October 1997 Resolved
REPLACE WASTED EXHAUST PIPING ON BOILER, GENERATORS (ALL), AND CARGO PUMP PRIME MOVERS (ALL).
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Deck/Cargo
Issued 19 October 1997 Resolved
CROP AND RENEW SIDE SHELL/BULKHEAD BETWEEN #1 PORT CARGO TANK AND FORWARD PORT VOID APPROX SIX FEET BELOW MAIN DECK (BTW LONGITUDINAL FRAMES 4 AND 5)WHERE HULL SET IN AND WELDS CRACKED. PROVE REPAIR (AIR TEST) TO USCG PRIORTO USE OF #1 CARGO TANK BUT NO LATER THAN COMPLETION OF DRY DOCK.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Construction/Loadline
Issued 19 October 1997 Resolved
REPAINT PORT LOAD LINE MARK AND VESSEL NAME (PORT AND STARBOARD).
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Electrical
Issued 19 October 1997 Resolved
PROVIDE BREAKER BLANKS FOR OPEN CIRCUITS IN #2 BREAKER PANEL.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Deck/Cargo
Issued 19 October 1997 Resolved
REPLACE VALVE STEM PACKING FOR: #8 PORT SUCTION, #4 PORT SUCTION, #2 STBD SUCTION, #7 STBD STRIPPING, #4 STBD SUCTION, #3 STBD SUCTION AND #2 STBD STRIPPING.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Electrical
Issued 19 October 1997 Resolved
PROVIDE BATTERY BOX COVER AND REMOVE NAILS USED AS WEDGES/CONDUCTORS ON BATTERY TERMINAL ON HOUSE GENERATOR.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Construction/Loadline
Issued 19 October 1997 Resolved
PROVIDE GASKET FOR PORT THERMAL FLUID EXPANSION TRUNK.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Deck/Cargo
Issued 19 October 1997 Resolved
PRIOR TO DEPARTURE, EMPTY FORWARD PORT RAKE END VOID OF OIL PRODUCT TO AUTHORIZED RECEPTION FACILITY AND GAS FREE VOID - MAKE READY FOR USCG INSPECTION.
Condition: Unknown
Due 19 October 1997
Resolved 27 October 1997
Engineering
Issued 18 December 1996 Resolved
BULBS & COVERS ON THERMAL FLUID HEATER CONTROL PANEL MISSING.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Navigation
Issued 18 December 1996 Resolved
AUDIBLE ALARM ON NAV LIGHT PANEL NOT OPERABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Deck/Cargo
Issued 18 December 1996 Resolved
BROKEN DOGS ON ACCESS TRUNK OPENINGS TO TANK NUMBERS 1P & 1S._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Deck/Cargo
Issued 18 December 1996 Resolved
AFT OUTBOARD AND FWD PORT AND STARBOARD PRIME MOVERS NOT OPERABLE AT TIME OF REINSPECTION.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Deck/Cargo
Issued 18 December 1996 Resolved
MACHINERY GUARDS ON PRIME MOVER/CARGO PUMP DRIVE SHAFT DETERIORATED.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Deck/Cargo
Issued 18 December 1996 Resolved
FLAME SCREENS ON RESTRICTED GAUGING PORTS CAKED WITH OIL.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Lifesaving
Issued 18 December 1996 Resolved
EPIRB NOT OPERABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 January 1997
Resolved 27 December 1996
Lifesaving
Issued 18 December 1996 Resolved
ONE (1) LIFE RING WITH LIGHT AND LINE NOT SERVICEABLE. ONE LIFERING WITH LIGHT MISSING.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Lifesaving
Issued 25 October 1995 Resolved
REPLACE GASKETS ON ALL CARGO TANK HATCHES.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Electrical
Issued 25 October 1995 Resolved
PROVE PROPER OPERATION OF THE #2 SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Lifesaving
Issued 25 October 1995 Resolved
CONDUCT HYDROSTATIC TEST OF AIR RECEIVER IN GENERATOR ROOM.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Engineering
Issued 9 December 1994 Resolved
INSTALL PROPER GOVERNOR OIL SUPPLY LINE IN STBD MDSHP CARGO PUMP ENGINE
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Electrical
Issued 9 December 1994 Resolved
INSTALL NEW POWER "ON" SWITCH ON FLUID HTR
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Electrical
Issued 9 December 1994 Resolved
PROPERLY DEAD END CABLES ON DECK HOUSE LIGHT PORT MIDSHIP PUMPHOUSE
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Construction/Loadline
Issued 9 December 1994 Resolved
FREE UP FROZEN DOGS ON HATCHCOVERS(VARIOUS LOCATIONS)
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Electrical
Issued 9 December 1994 Resolved
INSTALL PROPER ELECTRICAL CONNECTION BOX ON THERMAL FLUID HEATER CIRCULATION PUMP MOTOR.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Electrical
Issued 9 December 1994 Resolved
REPAIR RESET BUTTON TO EXHAUST FAN IN THERMAL HEATER ROOM
Condition: Unknown
Due 9 January 1995
Resolved 12 December 1994
Electrical
Issued 9 December 1994 Resolved
Install Blanks In breaker Box In Stbd Cargo Eng. House Fwd.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Lifesaving
Issued 29 October 1993 Resolved
REPLACE EPIRB BATTERY PRIOR TO EXPIRATION IN NOV 93.
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Deck/Cargo
Issued 29 October 1993 Resolved
RENEW OR REPAIR FOLLOWING GUAGES SERVICING THERMAL FLUID HEATER: COIL TEMP,FUEL OIL NOZZLE, FUEL OIL MANUAL, HEATER OUTLET MANUAL.
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Deck/Cargo
Issued 11 December 1991 Resolved
REPAIR REFRACTORY IN THERMAL FLUID HEATER COMBUSTION CHAMBER.
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Deck/Cargo
Issued 11 December 1991 Resolved
REPLACE THERMAL FLUID HEATER CONTROL PANEL INDICATOR LIGHTS THAT ARE BURNEDOUT.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Electrical
Issued 11 December 1991 Resolved
Label circuit breakers in gen rm aft fwd panels prior to 10 JAN 92.
Condition: Unknown
Due 11 December 1991
Resolved 12 December 1991
Lifesaving
Issued 11 December 1991 Resolved
Secure batteries with installed brackets ;and bolts prior to 10 JAN 92 in generator room and stbd fwd pump room.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Electrical
Issued 11 December 1991 Resolved
PROVIDE BLANK FOR MISSING CIRCUIT BREAKER (ONE) IN ELECTRICAL BOX LOCATED_x001C_ IN STARBOARD AFT PUMPROOM.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Electrical
Issued 11 December 1991 Resolved
Replace two deck lights (mercury vapor) at midships port and port aft houses with lenses prior to 18 DEC 91.
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Construction/Loadline
Issued 11 December 1991 Resolved
Remove fuel oil in port aft void bilge prior to 18 DEC 91.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Deck/Cargo
Issued 11 December 1991 Resolved
Install plug in stbd aft bunkering station containment prior to 18 DEC 91.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Lifesaving
Issued 11 December 1991 Resolved
Install a cleat at liferaft launch station prior to 10 JAN 92.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Deck/Cargo
Issued 30 March 1990 Resolved
PROVIDE REMOTE SHUTDOWN FOR THERMAL FLUID HEATER PER 46-111.103-9.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Deck/Cargo
Issued 30 March 1990 Resolved
PROVIDE LOW F.O. PRESS. TRIP SWITCH FOR THERMAL FLUID HEATER.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Lifesaving
Issued 14 December 1989 Resolved
INSTALL REMOVABLE STANCHIONS FOR INFLATABLE LIFERAFT FLOAT FREE ARRANGEMENT(ONE SIDE ONLY IS NECESSARY).
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Deck/Cargo
Issued 14 December 1989 Resolved
SUBMIT THERMAL FLUID HEATER TESTING PROCEDURE TO [name withheld] FOR USCG APPROVAL IN ACCORDANCE WITH 46 CFR 61.30-20.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Deck/Cargo
Issued 14 December 1989 Resolved
PREPARE THERMAL FLUID HEATER FOR TESTING BY APPROVED USCG PROCEDURE AND INTERNAL INSPECTION IN ACCRODANCE WITH 46 CFR 61.30.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Construction/Loadline
Issued 14 December 1989 Resolved
REPAIR SEPARATED OUTER RUB RAIL AND BUCKLED LONGITUDINALS/CRACKED WELDS, INSTARBORAD, FORWARD RAKE IN WWAY OF SIDE SHELL LONGITUDINALS #6, 7 AND 8 FROM THE COMPARTMENT TOP, BETWEEN DEEP WEB FRAMES 2 AND 3 FROM THE COMPARTMENT AFT BULKHEAD.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 21 April 1989 Resolved
PROVIDE A OPERATIONAL TEST OF THE SAFETY RELIEF VALVE ON THE AIR COMPRESSORWHICH IS PRESENTLY INOPERABLE. ORIGINAL COMPLIANCE DATE IS 19MAY89.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Engineering
Issued 18 December 1987 Resolved
PROVIDE EVIDENCE THAT ALL VALVES IN FUEL OIL SERVICE HAVE A MELTING POINT ABOVE 1700 DEGREES FAHRENHEIT AS REQUIRED BY 46CFR56.50-60(D)(2) AND NVIC 10-82(CH-1), OR INSTALL VALVES MADE OF STEEL OR EQUIVALENT.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Electrical
Issued 18 December 1987 Resolved
COMPLETE PLAN APPROVAL OF THE GENERATOR CIRCUIT BREAKERS, BUS BAR DETAILS &WIRING TO TRANSFORMERS AS REQUIRED BY 46CFR110.25 AND NVIC 10-82(CH-1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Electrical
Issued 18 December 1987 Resolved
COMPLETE PLAN APPROVAL OF THE GROUND DETECTION SYSTEMS AS REQUIRED BY 46CFR110.25-1(E) AND NVIC 10-82(CH-1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 18 December 1987 Resolved
SUBMIT TO AMERICAN BUREAU OF SHIPPING FOR REVIEW AND APPROVAL THE PLANS ANDSPECIFICATIONS REQUIRED BY 46CFR54.01-5(D)(1) & (E) FOR THE AIR RECEIVER. SEE NAVIGATION INSPECTION CIRCULAR 10-82(CH-1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 18 December 1987 Resolved
MAKE PERMANENT REPAIRS TO THE TEMPERATURE CONTROL REGULATOR ON THE THERMAL FLUID HEATER AND TEST AFTER COMPLETED. SEE 46CFR61.30-20.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Electrical
Issued 18 December 1987 Resolved
COMPLETE PLAN APPROVAL OF THE THREE TRANSFORMERS REQUIRED BY 46CFR111.20 & NVIC 10-82(CH-1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Electrical
Issued 18 December 1987 Resolved
COMPLETE PLAN APPROVAL OF THE 125KW GENERATOR AS REQUIRED BY 46CFR111.12 AND NVIC 10-82(CH-1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Electrical
Issued 18 December 1987 Resolved
COMPLETE SHORT CIRCUIT ANALYSIS PLAN APPROVAL REQUIRED BY 46CFR110.25-1(A)-(6) AND NVIC 10-82(CH-1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987

Casualty record · 2

18 June 2007Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 2968831
16 February 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4801691
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record