Records from 1985 to 1996. Most recent: operational control imposed, 14 February 1996.
Inspection history · 40
14 February 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 387718
14 February 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 885518
14 September 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1177567
31 August 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 522514
31 August 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 862000
20 July 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 860564
19 April 1994
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 365937
1 February 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 143912
28 October 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 361919
22 October 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 532441
22 July 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359666
5 June 1993
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 826988
25 January 1993
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 826439
6 January 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 491097
27 December 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2977
24 December 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 437505
24 December 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142352
11 December 1992
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1132283
14 October 1992
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 944198
3 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352901
3 September 1992
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1468701
23 April 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 669278
14 April 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 480855
25 February 1992
Deficiency Check · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 947216
16 January 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1449546
15 October 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 442543
17 September 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 939395
5 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 346015
5 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 941947
29 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 476963
29 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 938832
16 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 669276
14 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 669281
8 May 1991
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1238477
2 May 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 343543
6 April 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1220684
5 January 1990
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 923190
25 September 1987
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1027299
3 December 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 305992
14 March 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298491
Navigation
Issued 14 February 1996
Resolved
Vessel did not have onboard a currently correct Coast Pilot or foreign equilivent.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Accommodation/Occupational Safety
Issued 14 February 1996
Resolved
Vessel's master counselled in referance to discharging plastic ashes over the side.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Navigation
Issued 14 February 1996
Resolved
Vessel requested a letter of dev. to arrive CORMS. Gyro was replaced priorto departure
Condition: Unknown
Due 20 February 1996
Resolved 20 February 1996
Electrical
Issued 14 February 1996
Resolved
provide class report addressing conditions in the emergency battery compartment._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Lifesaving
Issued 20 July 1994
Resolved
PRIOR TO CONDUCTING CARGO OPS OR HANDLING CARGO VAPORS IN U.S. WATERS DEMONSTRATE AIR LOCK ALARM THAT LEADS INTO ELECTRIC MOTOR ROOM.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Fire Fighting
Issued 20 July 1994
Resolved
PRIOR TO CONDUCTING CARGO OPS OR HANDLING CARGO VAPORS IN U.S. WATERS DEMONSTRATE PROPER OPERATION OF EMERGENCY SHUT DOWN. ALL LIQUID AND GAS MANIFOLD VALVES MUST CLOSE WITH IN 30 SEC. .
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Fire Fighting
Issued 20 July 1994
Resolved
PRIOR TO CONDUCTING CONDUCTING CARGO OPS OR HANDLING CARGO VAPORS IN U.S. WATERS REMOVE PAINT COVERING ALL FUSIBLE ELEMENTS.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Navigation
Issued 20 July 1994
Resolved
PLACE EMERGENCY STEERING CROSS OVER DIAGRAM ON BRIDGE, PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Accommodation/Occupational Safety
Issued 20 July 1994
Resolved
REPLACE BROKEN PORT HOLE GLASS LOCATED WEATHER DECK, AMIDSHIPS FRONT OF_x001C_ SUPERSTRUCTURE PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Engineering
Issued 20 July 1994
Resolved
PLACE ON BOARD MARPOL STANDARD DISCHARGE CONNECTION PRIOR TO NEXT U.S. _x001C_ VOYAGE . REPAIR CURRENT SLUDGE DISCHARGE PIPING SUPOPORTS.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Deck/Cargo
Issued 20 July 1994
Resolved
PRIOR TO CONDUCTING CARGO OPS OR HANDLING
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Deck/Cargo
Issued 20 July 1994
Resolved
PRIOR TO CONDUCTING CARGO OPS IN U.S. WATERS INSTALL HIGH PRESSURE ALARMS IN CARGO CONTROL ROOM, THAT INDICATES HIGH PRESSURE IN EACH CARGO TANK, TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 25 July 1994
Resolved 15 August 1994
Lifesaving
Issued 20 July 1994
Resolved
REPAIR SEAL AROUND PAINT LOCKER LIGHT FIXTURE WIRING PRIOR TO NEXT U.S. _x001C_ VOYAGE.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Fire Fighting
Issued 20 July 1994
Resolved
PRIOR TO DEPARTURE PROVE OPERATION OF ALL WATER WASH DOWN SPRINKER HEADS TOTHE SATISFACTION OF THE CLASS SOCIETY.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Lifesaving
Issued 20 July 1994
Resolved
PRIOR TO DEPARTURE REPAIR OR REPLACE RUDDER ON PORT LIFEBOAT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Lifesaving
Issued 20 July 1994
Resolved
PRIOR TO DEPARTURE REPLACE BROKEN AND MISSING LIGHT COVERS IN GALLEY.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Navigation
Issued 20 July 1994
Resolved
PRIOR TO DEPARTURE PLACE ON BOARD COAST GUARD LIGHT LIST VOL. IV 1994 ED. WITH WRITTEN CORRECTIONS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Lifesaving
Issued 20 July 1994
Resolved
PRIOR TO CONDUCTING CARGO OPS OR HANDLING CARGO VAPORS IN U.S. WATERS DEMONSTRATE PROPER OPERATION OF FIXED GAS DETECTION SYSTEM.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Deck/Cargo
Issued 20 July 1994
Resolved
MAKE PERMANENT REPAIRS TO IGS AND DEMONSTRATE PROPER OPERATION TO COGNIZANTCOAST GUARD OCMI AT NEXT U.S. VOYAGE. VESSEL MAY USE NITROGEN WHILE CONDUCTING CARGO OPERATIONS TO KEEP VOID SPACES INERTED WHILE IN U.S. WATERS PRIOR TO EFFECTING PERMANENT REPAIRS TO IGS.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Deck/Cargo
Issued 3 September 1992
Resolved
FLAME SCREEN TO NUMBER 2 PORT BALLAST TANK VENT WAS HOLED AND BROKEN FROM FRAME.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Lifesaving
Issued 3 September 1992
Resolved
NON-CONDUCTIVE MATTING NEEDS TO BE PLACED IN FRONT AND REAR OF SWITCHBOARD IN ENGINE CONTROL ROOM.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Lifesaving
Issued 3 September 1992
Resolved
TWO FIRE EXTINGUISHERS NEED TO BE RE-CHARGED IN THE ENGINE ROOM.
Condition: Unknown
Due 5 September 1992
Resolved 13 October 1992
Deck/Cargo
Issued 3 September 1992
Resolved
VESSEL HAD PAINT STOWED IN THE STEERING SPACE. TOLD MASTER TO HAVE PAINT MOVED FORWARD TO PAINT LOCKER.
Condition: Unknown
Due 5 September 1992
Resolved 13 October 1992
Lifesaving
Issued 3 September 1992
Resolved
VESSEL HAD DRAEGER TUBES FOR VCM ONLY. NEED TO HAVE OTHER DRAEGER TEST TUBES WHEN CARRYING OTHER CARGO.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Deck/Cargo
Issued 3 September 1992
Resolved
DOGS WERE BROKEN ON HATCH OVERHEAD IN STEERING SPACE._x001C_
Condition: Unknown
Due 3 September 1992
Resolved 18 September 1992
Electrical
Issued 3 September 1992
Resolved
TWO LIGHTS IN THE STEERING SPACE WERE HANGING BY WIRE
Condition: Unknown
Due 5 September 1992
Resolved 13 October 1992
Fire Fighting
Issued 16 January 1992
Resolved
RECHARGE MIDSHIP STBD B-V DRY CHEMICAL EXTINGUISHER AT NEXT U.S. PORT.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Fire Fighting
Issued 16 January 1992
Resolved
MAKE PERMANENT REPAIRS TO PORTSIDE FWD B-V DRY CHEMICAL CYLINDER VENT VALVEHANDLE AND VALVE AT NEXT U.S. PORT.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Deck/Cargo
Issued 17 September 1991
Resolved
PROPERLY LABEL/MARK CARGO PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Deck/Cargo
Issued 17 September 1991
Resolved
PROVIDE TOXIC GAS INDICATORS FOR CARGOES AUTHORIZED TO BE CARRIED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Documentation
Issued 17 September 1991
Resolved
PROVIDE VALID CERTIFICATE OF FITNESS. CLASS SOCIETY HAS NOT CONDUCTED SATISFACTORY ANNUAL SURVEY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Deck/Cargo
Issued 17 September 1991
Resolved
PROVE PROPER OPERATION OF AIR LOCK, AUTOMATIC POWER CUTOFF AND ALARMS IN CARGO CONTROL/MOTOR ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Deck/Cargo
Issued 17 September 1991
Resolved
PROVE PROPER OPERATION OF AUTOMATIC PRESSURE SENSING DEVICE IN CARGO CONTROL/MOTOR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Deck/Cargo
Issued 17 September 1991
Resolved
PROVE PROPER OPERATION OF LOW LEVEL, HIGH LEVEL AND OVERFILL ALARMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Engineering
Issued 17 September 1991
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Accommodation/Occupational Safety
Issued 17 September 1991
Resolved
PROVE PROPER OPERATION OF MARINE SANITATION DEVICE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Deck/Cargo
Issued 17 September 1991
Resolved
PROVIDE CLASS SOCIETY DOCUMENTATION ATTESTING TO THE SAT. CHEMICAL COMPOSITION OF REPAIRS TO #1 CARGO TANK DOME PIPING. REPAIRS TO BE IAW IMOCODE FOR EXISTING SHIPS CARRYING LIQUEFIED GASES IN BULK, TABLE 6.2._x001C_ _x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Deck/Cargo
Issued 8 May 1991
Resolved
RPLACE ONE SPOOL PIECE MUD REMOVE ONE ABS TO WITNESS TESTING OF ALL ABOVE DECK CARGO PIPING LINES AT A PRESSURE OF 225 PSI. ABS TO FWD REPORT TO [name withheld] NO HANDLING OF CARGO UNTIL TESTING'S COMPLETED._x001C_ _x001C_
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO PROVE PROPER OPERATION OF ALL QUICK CLOSING VALVES._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO INSTALL GASKETS IN EACH CARGO TANK HATCH COVER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO PROVE PROPER OPERATION OF PRESSURED SENSING DEVICE AND MACHINERY SHUT DOWN IN MOTOR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Navigation
Issued 6 April 1991
Resolved
POST ON BRIDGE AND IN THE STEERING GEAR FLAT INSTRUCTIONS FOR SWITCHING OVER TO EMERGENCY STEERING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Fire Fighting
Issued 6 April 1991
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP PRIOR TO DEPARING THE PORT OFHOUSTON._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO MARK CARGO PIPE LINES WITH A LIQUID/VAPOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Fire Fighting
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO THROUGH THE PORT MANIFOLD MAKE PERMANENT REPAIRS TO THE DECK SPRAY SYSTEM AND PROVE PROPER OPERATION OF THE SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO PROVE PROPER OPERATIONS OF ALL QUICK CLOSING VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Documentation
Issued 6 April 1991
Resolved
PORT OIL DISCHARGE PLACARD ARE NECESSARY PRIOR TO NEXT U.S. PORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO UTILIZING INERT GAS GENERATOR OR LOADING CARGO REQUIRING INERT GAS. PROVIDE COAST GUARD WITH CLASSIFICATIONS SOCIETY SURVEY REPORT OF SYSTEM AND PROVE PROPER OPERATION OF SYSTEMS._x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PRIOR TO LOADING CARGO HAVE ON BOARD THE PROPER TOXICITS TUBES FOR CARGOES CARRIED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Deck/Cargo
Issued 6 April 1991
Resolved
PROVE PROPER OPERATION OF THE FIXED GAS DETECTION SYSTEM PRIOR TO LOADING CARGO._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991
Documentation
Issued 6 April 1991
Resolved
PRIOR TO NEXT U.S. PORT, POST COMPLETE MANEUVERING FACT SHEET._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1991
Resolved 6 April 1991