Records from 1991 to 2025. Most recent: inspection, 6 August 2025.
Inspection history · 62
6 August 2025
Annual Inspection · Internal Structural Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8199660
4 November 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7969979
18 May 2023
Hull Examination · MARPOL Annex I Examination · MTSA Verification · Deficiency Check · MARPOL Annex VI Survey · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7691321
27 July 2022
Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7513193
30 June 2021
Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7254462
14 July 2020
MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7006272
23 October 2019
MARPOL Annex IV Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6841644
12 May 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6691141
24 April 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6669608
22 January 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6614094
21 January 2019
Explosive Handling Operation-Commercial
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6613404
24 October 2018
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6567731
29 June 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6184476
20 March 2016
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5837659
3 February 2016
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5809305
10 September 2015
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5737658
22 September 2014
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4986787
26 April 2014
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4844978
20 August 2013
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4691317
31 January 2012
Examination of Repairs · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4234610
30 January 2012
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4234722
20 July 2011
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4088620
2 March 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3690038
25 September 2009
Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3603256
17 April 2009
Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3454698
12 March 2009
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3432604
9 February 2009
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3415768
23 September 2008
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3331701
19 March 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3172497
13 March 2007
COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2887438
6 October 2006
MARPOL Annex II Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2775839
18 March 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2054010
10 March 2004
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2022193
25 February 2004
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2013015
25 January 2004
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2022385
10 September 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1901639
9 May 2002
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1616300
15 April 2002
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1604964
4 September 2001
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1072824
11 June 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387094
10 May 2001
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 461953
12 March 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1060317
31 March 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1461261
23 April 1999
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402857
21 April 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386284
15 April 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 792409
2 May 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435920
7 May 1996
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404155
19 September 1995
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 198460
19 September 1995
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 752262
12 August 1995
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 113803
3 August 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 876910
19 May 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371074
8 June 1994
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1447355
3 December 1993
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 123116
8 October 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 361465
17 August 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 843026
19 July 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 671623
16 July 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 499938
1 September 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1269739
19 March 1992
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389552
22 August 1991
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 936581
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 August 2025
No resolution recorded
Each vessel must undergo dry dock, internal structure (ISE), and cargo tank internal exams in accordance with the 91.40.3(a) table. The port forward rake had a sharp inset between two frames that requires cropping and renewing the current hull plating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 September 2025 — due date passed with no resolution recorded
Resolution: Extending deficiency to be rectified by next drydock.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 August 2025
Resolved
Each vessel must undergo dry dock, internal structure (ISE), and cargo tank internal exams in accordance with the 91.40.3(a) table. the port aft rake had two frames that show significant wastage both of which require crop and renewal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 22 December 2025
Resolution: ABS attendance attested to final weld repair of longitudinals in port aft rake. CG Inspectors witnessed fit up of these repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 August 2025
Resolved
Manholes and flush scuttles in position 1 or 2 within superstructures other than enlcosed superstructures shall be closed be substantial covers capable of being made watertight. The hatch for the STBD void forward of the valve operation station had significant corrosion and wastage of scantling and should be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 22 December 2025
Resolution: ABS attested to replacement of new manhole hatch.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2025
Resolved
Each vessel must undergo dry dock, internal structure (ISE), and cargo tank internal exams in accordance with the 91.40.3(a) table. The following voids failed marine chemist certification and should be prepared for entry: #2 Port Void, #5 STBD Void, and #6 Port Void.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 4 December 2025
Resolution: Conducted ISE #2 Port, #5 STBD, and #6 Port voids. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 July 2023
Resolved
Any vessel of at least five net tons which engages in coastwise trade, must have a Certificate of Documentation (COD). Vessel COD expired 30JUN2023. 46CFR67.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: Operator applied for COD.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 26 July 2023
Resolved
An oceangoing ship of 400 gross tons and above must have a Coast Guard approved Shipboard Oil Pollution Emergency Plan (SOPEP). Vessel does not have a current Coast Guard approval letter for the vessel SOPEP. 33CFR151.27
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 28 July 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 26 July 2023
Resolved
Hose used to transfer oil or hazardous material must meet the requirements of 33CFR154.500. Vessel transfer hoses are not marked or maintained. Vessel is prohibited from carrying combustible liquids in bulk in #4 P/S voids for towing vessel. 33CFR155.800
Action required: 705 - Other - as specified
Resolved 8 December 2025
Resolution: Vessel no longer carries combustible liquids in #4 P/S voids. All valves are closed and tanks are no longer used. Tank is removed from COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 October 2022
Resolved
THE OWNER OR MANAGING OPERATOR SHALL MAKE A VESSEL AVAILABLE FOR DRY-DOCK EXAMINATIONS AND INTERNAL STRUCTURAL EXAMINATIONS AS REQUIRED BY THE REGULATIONS. THE VESSEL HAS NOT COMPLETED A CREDIT FOR DRYDOCK OR INTERNAL STRUCTURAL EXAMINATION TO THE SATISFACTION OF AN USCG MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2023
Resolution: The vessel must receive Credit for Dry-dock and Internal Structural Examinations PRIOR to the carriage of cargo.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 September 2017
Resolved
Vessel operator failed to make vessel availiable for annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 September 2017
Resolved
Vessel operated with CDC for approx 30 days without valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2017
Construction/Loadline › Hull › Transverse Frame
Issued 10 September 2015
Resolved
Void No. 1P:
FR 3.5 at sidelong 4, 8-inch crack; drill stop, V-out, and weld.
Action required: 705 - Other - as specified
Resolved 4 November 2015
Resolution: Received email from [name withheld] with digital photos of corrected deficiency.
Construction/Loadline › Hull › Transverse Frame
Issued 10 September 2015
Resolved
Void No.1S:
Vertical frame 5 – crop and renew full height at dry-dock.
Action required: 705 - Other - as specified
Resolved 4 November 2015
Resolution: Received email from [name withheld] with digital photos of corrected deficiency.
Construction/Loadline › Hull › Stringer
Issued 10 September 2015
Resolved
Void No.2P:
Sidelong 6 between 7 & 8, crop and renew.
Action required: 705 - Other - as specified
Resolved 4 November 2015
Resolution: Received email from [name withheld] with digital photos of corrected deficiency.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 January 2012
Resolved
The master, owner, operator, or agent of the vessel did not notify the Officer in Charge, Marine Inspection, that the vessel was dry-docked iaw CFR 46§ 91.40-5(a).
Action required: 705 - Other - as specified
Resolved 30 January 2012
Resolution: Inspections forwarded information to Investigation for enforcement.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 January 2012
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel did not notify OCMI of repairs being conducted to barge.
Action required: 705 - Other - as specified
Resolved 30 January 2012
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 March 2009
Resolved
#1 Port:
1. Side longitudinal #6 buckled crop and renew approx. 4' between frames #5 and transverse bulkhead #6.
Due 12 April 2009
Resolved 12 April 2009
Resolution: Side Long was replaces as original.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 March 2009
Resolved
2. Tripping brackets buckled at side longitudinals crop and renew three (3) Brackets #4, 5 & 6 in way of Transverse bulkhead #6.
Due 12 April 2009
Resolved 20 April 2009
Resolution: Tripping brackets were renewed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 March 2009
Resolved
#2 Port:
Tripping bracket at side longitudinal #6 clean area at tripping bracket and inspect of transverse bulkhead #6 inspect at dry-dock crop and renew as necessary.
Due 12 April 2009
Resolved 20 April 2009
Resolution: Tripping bracket was renewed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 March 2009
Resolved
#4 Port:
1. Ladder wasted crop and renew.
Due 2 April 2009
Resolved 20 April 2009
Resolution: A new ladder was installed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 March 2009
Resolved
#5 Port:
1. Ladder wasted crop and renew..
Due 12 April 2009
Resolved 20 April 2009
Resolution: A new ladder was installed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 March 2009
Resolved
#6 Port:
1. ladder wasted crop and renew.
Due 12 April 2009
Resolved 20 April 2009
Resolution: a new ladder was installed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 March 2009
Resolved
#7 Port:
1. Bulkhead #34 between side longitudinals #1 & #3 inspect at dry-dock repairs as necessary.
Due 12 April 2009
Resolved 20 April 2009
Resolution: Bulkhead was inspected and found satisfactory. It appears that the metal was cut to fit the sideshell. The sideshell is straight.
Deck/Cargo › Towing › Towline
Issued 13 March 2007
Resolved
Stern Emeregency Towline was improperly secured with hose clamps.
Condition: Unknown
Due 31 March 2007
Resolved 22 March 2007
Construction/Loadline › Hull › Side Shell
Issued 13 March 2007
Resolved
Significant insets on the portside sideshell in #1 port void, require crop and renew at next drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 March 2007
Resolution: No insets were noted during this inspection.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2007
Resolved
Aft rake ladders have significant wastage on rungs and require replacement.
Condition: Improper/Lack of Maintenance
Due 31 March 2007
Resolved 16 March 2007
Resolution: Aft rake ladders have been replaced with new ones.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 March 2007
Resolved
COI had expired ISE by 9 months, could not produce proof of ISE, COI was removed until ISE is completed and all deficiencies are corrected.
Due 31 March 2007
Resolved 23 March 2007
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 13 March 2007
Resolved
Vessel did not carry and active inventory of pollution response gear.
Due 31 March 2007
Resolved 16 March 2007
Construction/Loadline › Hull › Side Shell
Issued 13 March 2007
Resolved
Bow Portside Rake- Frame # 1 top outboard corner, weld connection to deck and side shell fractured. Approx. 8 inches.
Condition: Damaged By Earlier Event
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Bracket
Issued 13 March 2007
Resolved
Bow Portside Rake- Bulkhead #4, tripping bracket between rake longitudinal at turn of bilge and adjacent bulkhead vertical stiffener fractured at weld connection to vertical stiffener and distorted inboard.
Condition: Damaged By Earlier Event
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 March 2007
Resolved
Bow Portside Rake- Side long #4 corner triangular gusset plate connections to bulkhead #4 distorted and weld connection to side longitudinal fractured.
Condition: Damaged By Earlier Event
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Penetrations › Weld
Issued 13 March 2007
Resolved
#1 Port compartment, forward bulkhead #4 shows signs of water leakage at weld connections to deck in way of deck longs # 7 and # 10
Condition: Unknown
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 March 2007
Resolved
#1 Port Compartment, Bottom floor at frame 6 1/2 fractured at connection to side longitudinal #6
Condition: Damaged By Earlier Event
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 March 2007
Resolved
Stern portside rake side longitudinal #1 heavily wasted by water leakage from manhole, from forward bulkhead to 3rd side frame aft of bulkhead.
Condition: Improper/Lack of Maintenance
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 March 2007
Resolved
Stern Rake Port Side- Side longitudinal #2 heavily wasted from forward bulkhead full lengthto approx. 2" aft of second seide frame.
Condition: Improper/Lack of Maintenance
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Hull Plating
Issued 13 March 2007
Resolved
Stern portside Rake- plating just forward of stern log, between the two outboard rake longitudinals holed and previously temporarily repaired with an external doubler.
Condition: Damaged By Earlier Event
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 March 2007
Resolved
#2 Starboard Compartment third frame from forward side frame has 8 inch crack.
Condition: Damaged By Earlier Event
Due 31 March 2007
Resolved 23 March 2007
Construction/Loadline
Issued 11 June 2001
Resolved
#2 PORT VOID: SIDE LONGS 2 & 3, AT FRAME #3 BUCKLED. CROP AND RENEW FRAME AND SIDE LONGS.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 11 June 2001
Resolved
#2 STBD VOID: FRAMES 1 & 2 IWO SIDELONGS 1-3 BUCKLED. CROP AND RENEW FRAMESAND SIDELONGS.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 11 June 2001
Resolved
#2 STBD VOID: FRAMES 2-3 IWO SIDE LONGS 3-6 BUCKLED. CROP AND RENEW SIDE LONGS AND INSERT FRAMES 2 AND 3.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Electrical
Issued 19 May 1995
Resolved
MAKE EXPOLSION PROOF SHORE TIE CONNECTION AND ELECTRICAL SWITCHBOX IN WAY OF FUEL TANK VENT. PUMPING SYSTEM IS NOT TO ENERGIZED NOR IN ANY WAY POWER SUPPLIED TO CIRCUIT UNTIL CORRECTIONS ARE MADE. IAW 46 CFR 91.25-30 AND 46 CFR 111.105-31 (K)(1).
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995
Resolved
MAKE PERMENENT REPAIRS AND PROVE PROPER OPERATION OF PORT AND STBD NAVIGATION LIGHTS.
Condition: Unknown
Due 18 June 1995
Resolved 23 May 1995