Records from 1991 to 2023. Most recent: inspection, 31 March 2023.
Inspection history · 31
31 March 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7660284
4 April 2022
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7424459
22 March 2021
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7161369
29 May 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6962757
11 April 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6660240
12 April 2018
Internal Structural Exam · MTSA Verification · COI Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6390448
18 October 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6289988
23 November 2016
Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6046484
31 March 2016
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5844226
14 January 2016
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5797164
19 December 2014
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5045332
4 November 2013
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4746633
11 September 2013
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4716104
8 November 2012
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4480759
19 July 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4397154
2 July 2012
Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4364931
11 July 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4077752
11 July 2011
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4082119
20 December 2010
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3913796
24 November 2010
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3897688
26 April 2010
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3724809
26 March 2010
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3702555
28 April 2009
MTSA Verification · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3469450
20 February 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3152919
2 July 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2980454
22 December 2006
MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2845010
20 April 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2629549
21 March 2006
COI Inspection · Hull Examination · Plan Review (Other than "T") · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2606331
16 January 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1267521
9 October 1991
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250782
13 September 1991
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1353320
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 4 April 2022
Resolved
Each garbage management plan under paragraph (a) of this section must be in writing. Vessel did not have garbage management plan onboard and could not produce garbage management plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 11 April 2022
Resolution: Vessel provided proof of garbage management plan, record book, and receipts.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2022
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel could not provide records for monthly inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 11 April 2022
Resolution: Vessel provided proof of logbook used for monthly and annual inspections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022
Resolved
All pressure vessels must be provided with protective devices. The protective devices must be in accordance with the requirements of UG-125 through UG-136 of section VIII of the ASME Boiler and Pressure Vessel Code. The pressure relief valve’s set pressure relieved 50 PSI below indicated pressure.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 11 April 2022
Resolution: Vessel provided proof of new pressure relief valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. The self-igniting light may not be attached to the lifebuoys required by this section to be fitted with lifeline. The self-igniting light’s battery was expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 11 April 2022
Resolution: Vessel provided proof of new lights.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 April 2022
Resolved
Except as provided in paragraph (b) of this section, a tank vessel underway or at anchor must have all closure mechanisms on the following openings properly closed: (1) Expansion trunk hatches; (2) Ullage openings; (3) Sounding ports; (4) Tank cleaning openings; and (5) Any other tank vessel openings that maintain the seaworthy condition of the tank vessel and prevent the inadvertent release of oil or hazardous material in the event of a tank vessel accident. Vessel is required to produce a satisfactory vapor tightness test certification proving all tanks and openings are vapor tight prior to cargo operations.
33 CFR 155.815(a)
Action required: 705 - Other - as specified
Resolved 3 May 2022
Resolution: Vessel inspectors completed deck walk to check for vapor tightness.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 April 2022
Resolved
All cargo tanks to be vented at gage pressures of 4 pounds per square inch or less shall be constructed and tested as required by the requirements of the American Bureau of Shipping or other recognized classification society. Gas detection meters alerted Combustible/Explosive at 30-50% LEL on:
#2 Stbd on the butter worth opening and #3 Port cargo tank cover found leaking. Vessel required to replace gaskets on all cargo tanks, ullages, and openings.
46 CFR 32.65-40(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 31 May 2022
Resolution: Vessel replaced all gaskets.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2019
Resolved
Safety hand railing leading to the machinery space was found in broken at the attachment point.
Complete permanent repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 29 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 April 2019
Resolved
All safety and relief valves shall be set to relieve at a pressure which does not exceed the max allowable working pressure.
Please provide proof that the air pressure gauge or safety relief valve has been calibrated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 29 April 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 April 2019
Resolved
De-scale tank top in way of starboard side machinery space housing to facilitate further inspection to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 29 May 2020
Resolution: MI's inspected and cleared the descaling on top of tank top during annual inspection
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 14 January 2016
Resolved
Rising stick for cargo tank 3-P was found unserviceable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 January 2016
Resolution: Replaced during inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 January 2016
Resolved
The location of the equipment shall be such as in the opinion of the OCMI will be most convenient in case of emergency. Bracket for fire extinguisher (port side, midship) was improperly sized. Replace bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 16 January 2016
Resolution: Received photos of properly installed bracket.
Lifesaving › Lifebuoys › Serviceable
Issued 14 January 2016
Resolved
Each lifesaving appliance must be in working order and ready for immediate use. Grab line on aft lifebuoy was found unserviceable. Replace grab line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 16 January 2016
Resolution: Received photos of replaced grab line.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 January 2016
Resolved
Name was missing from lifejacket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 14 January 2016
Resolution: Received photo of name properly placed on lifejacket.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 14 January 2016
Resolved
Exhaust leak found on aft cargo pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 8 February 2016
Resolution: Verified exhaust leak has been fixed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 November 2013
Resolved
Vessel must replace cracked lifebuoy light.
Due 4 December 2013
Resolved 3 December 2013
Resolution: Inspected satisfactory by CGMI.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 November 2013
Resolved
Vessel must have FCC liscense.
Due 4 December 2013
Resolved 3 December 2013
Resolution: Inspected satisfactory by CGMI.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 4 November 2013
Resolved
Vessel must make all discharge pressure gauges visible from engine operating station.
Due 4 December 2013
Resolved 3 December 2013
Resolution: Inspected satisfactory by CGMI.
Electrical › Electric Supply System (service) › Cable
Issued 4 November 2013
Resolved
Vessel must replace all welding cable with approved marine grade cable for battery installations.
Due 16 December 2013
Resolved 16 December 2013
Resolution: Verified all battery installations were outfitted with marine grade cable. Vessel used Bostrig 125 Type P marine cable that is approved under IEEE 1580 (2001)
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 4 November 2013
Resolved
Vessel must replace non-working emergency battery powered lighting in office and generator space.
Due 4 December 2013
Resolved 3 December 2013
Resolution: Inspected satisfactory by CGMI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 November 2013
Resolved
Vessel required to have proper medical supplies and eyewash station as discussed.
Due 4 December 2013
Resolved 3 December 2013
Resolution: Inspected satisfactory by CGMI.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 4 November 2013
Resolved
Vessel must replace broken and malfunctioning risign sticks.
Due 4 December 2013
Resolved 3 December 2013
Resolution: Inspected satisfactory by CGMI.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 9 July 2012
Resolved
Vessel has one liferaft located above the deck house (aft portside); liferaft needs to be accessible from either side. Vsl has option to either relocate single liferaft for launching on either side or install an additional liferaft. Make available to a marine inspector; to be completed by next gas freeing or NLT 30 Apr 2014 (ISE).
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 19 July 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 2 July 2012
Resolved
Portside midship BII fire ext shows recharge: service extinguisher and provide documentation to CG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 July 2012
Resolved 19 July 2012
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 2 July 2012
Resolved
B V extinguisher shows no proof of servicing; provide servicing document to CG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 July 2012
Resolved 19 July 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 March 2010
Resolved
Make repairs to stanchions and cables in cargo area as discussed with vsl rep.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 29 March 2010
Resolution: Vsl rep emailed photos of repairs and found satisfactory,.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 April 2009
Resolved
Provide proof of enrollment in a DAPI program. Place all required documentation as well as required Employee Assistance paraphernalia (free hotline, literature) on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Resolution: Proof of enrolment to the DAPI program was provided to MI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 28 April 2009
Resolved
Place a B-V, semi-portable fire extinguisher on deck. Extinguisher is to properly marked and secured.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Resolution: B-V was secured and marked.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 28 April 2009
Resolved
Relocate B-II F/E in vicinity of bow anchor hydraulic pump engine (not to be located inside space).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Resolution: B-II was relocated outside the space.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 28 April 2009
Resolved
Repair anchor windlass gear box leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Resolution: Leak was repaired.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 April 2009
Resolved
Mark all lifesaving and fire fighting gear with new vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Resolution: Lifesaving and Firefighting equipment was marked with the vessel''s name.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 April 2009
Resolved
Provide a COD with vessel's new name and owner/operator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2009
Resolved 8 May 2009
Resolution: COD with vessel''s new name and owner/operator was provided to MI.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 28 April 2009
Resolved
Stencil Safe Working Load on deck crane/boom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Resolution: Safe Working Load on deck crane/boom was stencil.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 20 February 2008
Resolved
Transfer hose to be labeled with Oil Service Only, MAWP and test date.
Condition: Unknown
Due 20 March 2008
Resolved 13 March 2008
Resolution: Hoses marked.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 20 February 2008
Resolved
Replace wooden plugs on coaming around oil service tank with mechanical closure devices.
Condition: Placed in Improper Service
Due 20 March 2008
Resolved 13 March 2008
Resolution: Scuppers closed & one drain installed.
Engineering › Compressed Air System (start air) › Control Gear
Issued 20 February 2008
Resolved
Install relief valve on pressure vessel not to exceed MAWP.
Condition: Placed in Improper Service
Due 20 March 2008
Resolved 13 March 2008
Resolution: Verified proper operation of new relief valve.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 20 February 2008
Resolved
Permanently afix pressure vessel to deck.
Condition: Unknown
Due 20 February 2008
Resolved 13 March 2008
Resolution: Mounts welded.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 February 2007
Resolved
Purchase and install battery protection boxes for all batteries located in generator / cargo pump engine space as discussed.
Action required: 705 - Other - as specified
Resolved 16 March 2007
Resolution: Verified installation of protective battery boxes.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 February 2007
Resolved
Install pull handles for emergency shutdown cables for cargo pumps as discussed.
Action required: 705 - Other - as specified
Resolved 27 February 2007
Resolution: Verified installation of pull handles for emergency cables.